• Title/Summary/Keyword: Case D/B

Search Result 1,627, Processing Time 0.031 seconds

Performance Analysis of Reed Solomon/Convolutional Concatenated Codes and Turbo code using Semi Random Interleaver over the Radio Communication Channel (무선통신 채널에서 RS/길쌈 연쇄부호와 세미 랜덤 인터리버를 이용한 터보코드의 성능 분석)

  • 홍성원
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.861-868
    • /
    • 2001
  • In this paper, the performance of Reed Solomon(RS)/convolution리 concatenated codes and turbo code using semi random interleaver over the radio communication channel was analyzed. In the result, we proved that the performance of decoder was excellent as increase the interleaver size, constraint length, and iteration number. When turbo code using semi random interleaver and Hsiconvolutional concatenated codes was constant constraint length L=5, BER=10-4 , each value of $E_b/N_o$ was 4.5〔dB〕 and 2.95〔dB〕. Therefore, when the constraint length was constant, we proved that the performance of turbo code is superior to RS/Convolutional concatenated codes about 1.55〔dB〕 in the case of BER=10-4.

  • PDF

Analysis of Acoustic Target Strength for the Submarine with Alberich Anechoic Coating Effects (알베리히 무반향 코팅재 효과를 고려한 잠수함의 음향 표적강도 해석)

  • Kwon, Hyun-Wung;Hong, Suk-Yoon;Kim, Hwa-Muk;Song, Jee-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.4
    • /
    • pp.410-415
    • /
    • 2013
  • Acoustic target strength (TS) is one of the most considerable design elements for survival capacities of the submarine. It needs to reduce acoustic TS that submarines are getting larger and larger, Alberich anechoic coatings are widely used as the representative method. In this paper, the finite element method (FEM) is used to analyze the reflection and transmission coefficients of Alberich anechoic coatings, which have periodic unit cells. The FEM results are compared with experimental results in the literature. Moreover, acoustic TS for the submarine is analyzed by using that result. Finally, it is shown that acoustic TS (Case 1: 10dB, Case 2: 6dB) are reduced due to the use of Alberich anechoic coatings.

Noise Characteristics of Air Cleaners and Humidifiers (공기청정기와 가습기의 소음특성)

  • Kim, Yong Hee;Park, Ji Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.20-26
    • /
    • 2016
  • This study investigated noise characteristics of air cleaners and humidifiers in terms of frequency domains and measurement directions. Noise levels of 31 air cleaners and 36 humidifiers were measured in an anechoic chamber according to the related group standards. As for air cleaners, 5 receiving points of 1 m off from front, rear, left, right and top surfaces of the product were considered. In case of humidifiers, 4 receiving points without the rear position were considered in the same manner as air cleaners. In each case, A-weighted equivalent continuous sound level was measured three times for 1 min. As a results, most of the measured air cleaners and humidifiers showed the highest noise levels at top directions due to the air ventilating location. In case of air cleaners, averaged noise levels of top and rear positions were 49.9 and 48.2 dB(A), respectively, whereas averaged noise level of other positions was all 45.2 dB(A). In case of humidifiers, averaged noise level of top position was 44.1 dB(A) whereas averaged noise levels of other positions were 38.7 to 39.1 dB(A). In addition, high frequency content of 1 kHz and 3.15 kHz to 4 kHz for air cleaners and middle frequency content of 500 Hz to 1.6 kHz for humidifiers showed significant contribution to determination of overall noise levels with correlation coefficient of 0.9 and above.

The Underwater Noise of Fishing Gears in Operation (망어구의 수중소음에 관한 연구)

  • 윤갑동
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.16 no.1
    • /
    • pp.1-15
    • /
    • 1980
  • An underwater recording system was designed to measure the sound spectra of the underwater noises produced by fishing gears in operation. Recorded were noi~es from three types of fishing gears: an anchovy set net, three anchovy boat seine net and a stern trawlnet. Acoustic analysis were made using a heterodyne analyzer, a digital frequency analyzer and a level recorder. The no;'e produced by the anchovy set net was found in the high frequency region of the onset of ambient noise spectrum with a slope of - 6 dB/octave. Here the ambient noise spectrum is higher, though similar in shape, than Knudsen spectrum, and is attributed to the breaking action of the coastal wave. Measured noise spectra during the fishing operations of the anchovy boat seine nets are attributed to the background noise of the sea in the presence of the fishing vessels. The frequency distribution of the noise was 20~5, 000 Hz in the case of two steel anchovy boat seiners, and 20-3,000 Hz in the case of the wooden anchovy boat seiner. The predominant frequency range was 250~350 Hz and maximum sound pressure level was 122 dB (re $1\muPa$) in the case of the steel boat and ] 17 dB in the case of the wooden boat. The noises produced by the trawl fishing gears are remarkably higher than the background noi~e in the presence of the fishing vessel. The frequency distribution of the noi~e was 20-6,300 Hz. The predominant frequency range was 100~200 Hz and maximum sound pressure level was 137 dB ( re $1\muPa$) . The noise spectra were not so much different from that caused by vibrations of the towing cable and the structure of the ground rope of the trawl net towed in an experimental tank.

  • PDF

Circular-Polarized Dipole Antenna with Reflector (반사판 부착 원편파 다이폴 안테나)

  • 한성민;이호선;우종명
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1139-1146
    • /
    • 2000
  • In this paper, circular-polarized dipole antenna with a novel structure is designed, simulated and fabricated for PCS or IMT-2000 base station at an arbitrary test frequency(1.575 GHz). Its radiation pattern is analyzed by means of physical optics(PO). The designed antenna is made up of a horizontal and a vertical dipole elements at a height of λ/4 above an reflector. One of λ/4 length vertical dipole element is located at a height of λ/8 above an reflector. In this case, circularly polarized radiation pattern is obtained by making impedance difference due to adjusting the length of each element. The characteristic of antenna measured from this study is that return loss is 18.4 dB, -10 dB bandwidth is 360 MHz(22.8%), 2 dB axial ratio bandwidth is 30 MHz, -3 dB beamwidth is 76$^{\circ}$, 2 dB axial ratio beamwidth is 58$^{\circ}$, axial ratio is 1.7 dB at 1.575 GHz. Radiation pattern is in well agreement with the result of PO.

  • PDF

Perfonnance Analysis of the Combined AMC-MIMO Systems with MCS Level Selection Method (MCS 레벨 선택 방식에 따른 AMC-MIMO 결합 시스템의 성능 비교)

  • Hwang In-Tae;Kang Min-Goo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7C
    • /
    • pp.665-671
    • /
    • 2006
  • In this paper, we propose and observe a system that adopts Independent-MCS (Modulation and Coding Scheme) level for each layer in the combined AMC-V-BLAST (Adaptive Modulation and Coding-Vertical-Bell-lab Layered Space-Time) system. Also, comparing with the combined system using Common-MCS level, we observe throughput performance improvement. As a result of simulation, Independent-MCS level case adapts modulation and coding scheme for maximum throughput to each channel condition in separate layer, resulting in improved throughput compared to Common-MCS level case. Especially, the results show that the combined AMC-V-BLAST system with Independent-MCS level achieves a gain of 700kbps in $7dB{\sim}9dB$ SNR (Signal-to-Noise Ratio) range.

Analysis of Parameters for a RF Receiver System in the CMS (CMS에서 RF수신기 시스템의 파라메타 분석)

  • Chun, Jong-Hun;Park, Jong-An
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 1997
  • In this paper, A method is proposed to analyze the noise figure for some parameters based on IS-98 recommendation when a RF receiver for the CDMA mobile station is designed. Simulation results show that the maximum noise figure of the receiver, which fits in the receiving sensitivity of the mobile station, is about 11dB, and this value is smaller about 3dB than the existing specification. In addition, we have tested the relationship between frame error rate and Eb/Nt of traffic channel for each coding rate. according to the speed changes of the traffic channel. In order to prove IMD to be most important variable in LNA we have tested IMD spurious in case that LNA always turns on and in case that LNA turns ON/OFF.

  • PDF

Therapeutic Effects of Korean Medical Treatment Combined with Threshold Sound Conditioning on Presbycusis: A Case Report (한방 복합 치료 및 소리 재활 치료로 호전된 노인성 난청 치험 1례)

  • Jea, Ha-Kyung;Min, Ye-Eun;Oh, Yeon-Ju;Kang, Jun-Hyeok
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.34 no.3
    • /
    • pp.102-111
    • /
    • 2021
  • Objectives : The purpose of this study is to report the case of a presbycusis patient whose hearing had improved. Methods : A 81-year-old male diagnosed with presbycusis were treated with Korean medical interventions (acupuncture combined with electromagnetic stimulation and pharmacoacupuncture) and Threshold sound conditioning(TSC) for 3 months. Pure tone audiometry(PTA) was performed for the evaluation. Results : The patient's hearing was improved from moderate to mild level according to the Classification of Hearing Loss(International Organization for Standardization, 1969). The average hearing were improved from 40.5 dB to 32.7dB on the left side, 46.9dB to 34.1dB on the right side. Conclusions : We observed an improvement in a presbycusis patient's hearing and hereby suggest the possibility of Korean medical treatment and TSC's ameliorating effect on sensorineural hearing loss as well as prebyscusis.

Study on the Linear Non-Complementary 2-Arm Slot Sinuous Antenna for Low Input Impedance (저 입력 임피던스를 위한 선형 비 상보 2-암 슬롯 시누어스 안테나에 관한 연구)

  • Yoon, Sung Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.12
    • /
    • pp.2461-2468
    • /
    • 2015
  • Sinuous antenna is utilized in a number of application like direction-finding system that require ultra wideband, but because of high input impedance of the antenna, it is difficult to design low-profile antenna and balun. In this study, we used Babinet's principle and proposed linear 2-arm slot sinuous antenna that is divided sinuous 6 cell with equal spacing between the most largest radius $R_1=31.83mm$ and the smallest radius $R_p=1.7mm$ instead of exponential 2-arm strip sinuous antenna for 2-18[GHz] frequency band to obtain low input impedance, and we have studied -10dB bandwidth of antenna when has been fed by $80{\Omega}$ instead of $188{\Omega}$ at feeder point. As a result, we have obtained return loss below than -10dB for about 4-18[GHz] frequency range in the case of slot antenna, but at all frequency band, return loss was above -10dB in the case of strip antenna.

A Case Study on Noise Reduction Effect of Two-layer Porous Asphalt Pavement in an Urban Area (도심지 내 복층 저소음포장 설치에 따른 소음저감 사례연구)

  • Jung, Jong-Seo;Sohn, Jeong-Rak;Lee, Soo-Hyoung;Yang, Hong-Seok
    • International Journal of Highway Engineering
    • /
    • v.18 no.5
    • /
    • pp.49-56
    • /
    • 2016
  • PURPOSES : In this study, noise reduction effect of a two-layer porous asphalt pavement was investigated through site measurement and computer simulation. METHODS : To examine noise reduction effect, a 3 km long quiet pavement was installed by removing previous normal pavement, which had a rather low porosity. The studied site was a high-rise apartment building surrounded by the quiet pavement and Seoul ring road with heavy traffic volume, indicating relatively high background noise. RESULTS : The measurement result before and after installing the quiet pavement showed a noise reduction effect of 4.3 dB(A) at a distance of 7.5 m from the road. After validating the accuracy of simulation using SoundPLAN, the reduction in SPL(sound pressure level) at the facades by the quiet pavement was predicted by considering five different road conditions generating traffic noise from each road or in the combination of the quiet pavement and Seoul ring road. In the case of no noise from Seoul ring road, noise reduction at the facades was 4.2 dB(A) on average for 702 housing units. With background noise from Seoul ring road, however, the average SPL decreased to 2.0 dB(A). Regarding subjective response of noise, the number of housing units with a noise reduction of over 3 dB(A) was 229 out of 706 units (approximately 32%). For 77 housing units, the noise reduction was between 1~3 dB(A), while it was less than 1 dB(A) for 400 housing units. CONCLUSIONS : The overall result indicates that the quiet pavement is useful to reduce noise evenly at low and high floors compared to noise barriers, especially in the urban situation where background noise is low.