• Title/Summary/Keyword: Case 2

Search Result 47,088, Processing Time 0.061 seconds

Numerical Analysis of Combustion Field for Different Injection Angle in End-burning Hybrid Combustor (End-burning 하이브리드 연소기 인젝터 분사각에 따른 연소 유동장의 수치적 연구)

  • Yoon, Chang-Jin;Kim, Jin-Kon;Moon, Hee-Jang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.12
    • /
    • pp.1108-1114
    • /
    • 2007
  • The effect of oxidizer injection angle on the combustion characteristics of end-burning hybrid combustor is numerically investigated. Besides the previously studied parameter(injector arrangement, port diameter and O/F ratio), three different injection angle are considered: parallel angle to fuel surface(Case 1), +30 degree inclined angle toward the fuel(Case 2) and 30 degree inclined angle toward the nozzle(Case 3). It is found that Case 2 has the best mixing pattern in the upstream area but has the worst combustion efficiency since non negligible amount of unburned fuel is expelled from the nozzle. In contrast, though Case 1 and Case 3 showed relatively low mixing effect than the Case 2, they had high combustion efficiency. The comparison of numerical results between Case 1 and Case 3 demonstrate that no major difference is encountered, however, Case 1 is expected to have the best combustion efficiency due to the low residence time of the Case 3 injector which heads toward the nozzle.

Experimental study on the effects of EVA(Ethylene Vinyl Acetate) for solar cell's long-term life (EVA(Ethylene Vinyl Acetate) 수지가 태양전지의 장기적인 수명에 미치는 영향에 관한 실험적 연구)

  • Kim, Seon Yong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.397-401
    • /
    • 2015
  • In this study, analysed the characteristics of power drop and surface damage in solar cell through high temperature and humidity test in the 3 case of EVA(ethylene vinyl acetate) and 2 case ribbon thickness. The solar cells were tested during the 500hr in $85^{\circ}C$ temperature and 85% relative humidity conditions, that excerpted standard of PV Module(KS C IEC-61215). Through the EL(Electroluminescence) shots, specimen's surface have partialy damaged. Before and after high humidity and high temperature test, ribbon thickness $200{\mu}m$ EVA1 case power drop rate was 8.463%, EVA2 case was 6.667%, EVA3 case was 6.373%. In the ribbon thickness $250{\mu}m$ EVA1 case power drop rate was 6.521%, EVA2 case was 8.517%, EVA3 case was 6.019%. EVA3 case was the lowest power and FF(fill factor) drop rate at the 2 case of ribbon thickness, because EVA3 is laerger than EVA1 and EVA2 in thickness, elongation and tensile strength.

A Study on Face Types and Glasses Wear of Young Peoples (청년들의 얼굴형태와 안경착용에 관한 연구)

  • Kim, Hye-Dong;Kim, Hyun-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.35-38
    • /
    • 2007
  • This study surveyed on eye size, face types and glasses wears of normal 100 young peoples from 20 to 30 years old. The analysis of data resulted in as follows: 1. The vertical eye size were in case of below 2.4 mm (2%), 2.5-2.9 mm (40%), 3.0-3.5 mm (57%), and in case of high 3.6 mm (1%). 2. The horzontal eye size were in case of below 1.1 mm (52%), 1.2-1.4 mm (28%), 1.5-1.7 mm (18%), and in case of high 1.8 mm (2%). 3. As a whole, the face types were oval type (29%), round type (24%), square type (18%), and triangle type (2%). 4. As the male, the face types were oval type (32%), round type (10%), square type (26%), and triangle type (32%). 5. As the female, the face types were oval type (18%), round type (40%), square type (12%), and triangle type (30%). 6. As a whole, the FPD size were in case of larger than PD (49%), in case of suitable (25%), in case of smaller than PD (49%). 7. As the male, the FPD size were in case of larger than PD (28%), in case of suitable (36%), and in case of smaller than PD (32%). 8. As the female, the FPD size were in case of larger than PD (44%), in case of suitable (26%), and in case of smaller than PD (30%).

  • PDF

A Comparative Evaluation on the Thermal Insulation Performance of Windows according to the Temporary Improvement Method (창호의 단열성능 간이 개선방법의 비교 분석)

  • Lee, Sung-Jin;Kim, Jeong-Gook;Kim, Jonghun;Jeong, Hakgeun;Lee, Jin-Sook;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.77-82
    • /
    • 2015
  • The purpose of this study is to compare the thermal insulation performance of windows according to the formation of air layer and to evaluate its energy efficiency on a selected standard house. A thermal insulation test, KS F 2278 was used to measure U-values (Heat transmission coefficients) for the following three cases: the first case (Case 1) is a Low-E pair glass (Argon injected), the second case (Case 2) is a Low-E pair glass with the air cap attached on the glass surface, and the third case (Case 3) is a Low-E pair glass, on the frame of which the air cap is attached. The evaluation of the energy efficiency was conducted according to a building energy calculation method from ISO 13790, calculation of energy use for space heating and cooling, using the U-values obtained from the thermal insulation tests. As results of the tests, the U-values of Case 1, Case 2, and Case 3 were $1.668W/m^2{\cdot}K$, $1.568W/m^2{\cdot}K$, and $1.319W/m^2{\cdot}K$ respectively. The Case 2 had about 5.9% lower value than the Case 1, and the Case 3 had about 20.9% lower value than the Case 1. It seems that the thermal performance of the windows is attributed to an increase of the heat resistance and the thickness of air layer. An evaluation of the energy efficiency of the three cases on the selected standard house showed that the amount of heating energy demand per unit area was $7.776kWh/m^2{\cdot}yr$ for the Case $1,6.856kWh/m^2{\cdot}yr$ for the Case 2, and $4.856kWh/m^2{\cdot}yr$ for the Case 3. This study suggests that the formation of air layer (by using air cap) and its thickness should reduce the heat energy demand and thus improve the energy saving efficiency

Energy Economic Analysis of Standard Rural House Model with PV System (PV 시스템이 적용된 농어촌 주택 표준모델의 에너지 경제성 분석)

  • Lee, Chan Kyu;Kim, Woo Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1540-1547
    • /
    • 2013
  • The energy economic analysis of the standard rural house model with PV system was performed based on annual energy demand calculation using the EnergyPlus to contribute in reducing building energy which occupies 25% of national energy consumption and in developing a low-energy & eco-friendly house model. Two types of PV system installation was considered to cover electricity demand for cooling, electric, and heating devices. For the selected house model, heating energy demand is 7 times higher than cooling energy demand. For the Case1, it is favorable to use electricity from PV system for cooling and electric devices and to sell surplus electricity. For the Case2, it is favorable to use electricity from PV system for cooling, electricity and heating devices and to sell surplus electricity. Considering the installation cost of PV system and heat pump air conditioning system, the break-even point of Case1 and Case2 are about 13 and 11 years respectively. Although the installation cost of Case2 is more expensive, Case2 provides three times more profit than Case1 after the break-even point. Because the expected average life time of the selected PV system is 25 years, Case2 is more favorable option for the given standard rural house model.

Characteristics of Ground Movement in High Filling Abutment on Soft Ground (연약지반상 고성토 교대구간의 지반거동 특성)

  • Heo, Yol;Song, Seokcheol;Ahn, Kwangkuk;Oh, Seungtak;Seo, Sanggu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.7
    • /
    • pp.13-23
    • /
    • 2008
  • In this study, the centrifuge tests and numerical analyses were performed to investigate the lateral flow behavior and stability of abutment when high filling was applied on the soft ground improved by SCP. The centrifuge model tests and numerical analyses were fulfilled in the case of the back of abutment filled by EPS (case 1) and soil (case 2), and the potentiometer was installed on the abutment and fill to measure the vertical and horizontal displacement at the top of abutment. As a result of the centrifugal tests, the horizontal displacement of abutment in the case 1 was 1.4cm that is almost coincide with the results of numerical and satisfy the allowable standard. On the other hand, the horizontal displacement of abutment in the case 2 was 12 cm that is 18% greater than that of numerical analysis and exceed the allowable standard. As a result of analysis, the maximum horizontal displacement of pile was 1.26 cm in case 1 that satisfies the criterion of allowable horizontal displacement (1.5 cm). In contrast, the maximum horizontal displacement of pile was 1.005 m in case 2 that greatly exceeds the allowable horizontal displacement.

  • PDF

Research on Thermal Comfort by Increasing Air Conditioner Temperature (에어컨 온도상승에 따른 온열쾌적성 변화에 관한 연구)

  • Kim, Hyung-Chul;Kum, Jong-Soo;KIM, Dong-Gyu;CHUNG, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.18 no.2
    • /
    • pp.77-84
    • /
    • 2006
  • This research evaluates thermal comfort by comparing the case of maintain cooing temperature of room with the case of raising it at the point of time that human body begins to adapt. An experiment uses constant temperature & humidity chamber 2 places. Pretesting room make up summer season environment, the testing room control by air-conditioner. In condition that maintain temperature of $33^{\circ}C$. The subjects stay in the pretesting room during the 30 minute for the heat storage amount of the normal summertime. The subjects stay in the testing room under each case (case 1: maintaining $24^{\circ}C$, case 2: maintaining $26^{\circ}C$, case 3: up $1^{\circ}C$ after maintaining $24^{\circ}C$ during 30 minute, case 4: up $1^{\circ}C$ after maintaining $26^{\circ}C$ during 40 minute). 1. Result of comparison of case 1 and case 2 appears that thermal sensitive vote examine from slight cool to cool and thermal comfort examine slight comfort by temperature rise at human body adaptation point of time.2. Test of case 3 and case 4 appear similar value at thermal sensitive vote and thermal comfort.3. Through the case 2 and case 4, continuous thermal comfort maintain at $24^{\circ}C$, if raise $26^{\circ}C$, same thermal comfort maintain after a human body adaptation temperature rising effect bring energy saving.

Treatment of Gastroesophageal Reflux Disease in 2 Young Dogs

  • Han, Jihee;Kim, Yeonsoo;Seo, Kyoungwon;Song, Kunho
    • Journal of Veterinary Clinics
    • /
    • v.38 no.5
    • /
    • pp.231-234
    • /
    • 2021
  • A 14-month-old, intact female Maltese (case 1) and a 26-month-old, spayed female Dachshund (case 2) had persistent regurgitation over 1 year and 2 years, respectively. In both cases, there were not specific findings in blood examination. Diagnostic imaging and fluoroscopy revealed that gastroesophageal reflux (GER) occurred when the patients ate a barium meal without abdominal contraction. They were treated with proton-pump inhibitor (esomeprazole), sucralfate and prokinetics (cisapride) while in a standing position for an hour after every meal, according to the gastroesophageal disease (GERD) suggested treatment. The case 1 dog was discharged with improved clinical signs, and the case 2 dog also had been improved clinical signs; however, aspiration pneumonia occurred in case 2, which was thought to be a complication from GERD. After receiving treatment for aspiration pneumonia, the case 2 dog was discharged from the hospital. Since there was no further improvement in symptoms after discharge, the case 1 dog was euthanized by owner's request, and the case 2 is alive, having only mild clinical signs upon the writing of this paper.

Development of Awning System using Light Shelf - Focusing on the light environment and lighting energy reduction performance improvement -

  • Jeong, Jinsoo;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: Various studies have been performed to address the issue of increased energy use by buildings. In particular, research on complex envelopes that combines diverse envelope element techniques is currently in progress in the building sector. The present study aimed to develop an awning system using a light shelf, and to verify its validity through performance evaluation. Method: In the present study, a testbed was established for the performance evaluation of the awning system using a light shelf, and the uniformity ratio and lighting energy consumption were compared and analyzed relative to those with no awning and light shelf installation (Case 1), awning installation (Case 2), and light shelf installation (Case 3). Result: 1) In the present study, an awning system using a light shelf (Case 4) where an opening is made on the awning screen and natural light can be introduced through the light shelf located at the bottom was developed. 2) The optimum standard for Case 4 obtained through the performance evaluation was a 0.6m lighting length and a 2m extension length at a light shelf angle of $30^{\circ}$. 3) Case 4 with the optimum standard had a 5.5% lower uniformity ratio than Case 2, but had a higher uniformity ratio than Case 1 and Case 3. 4) Case 4 with the optimum standard showed 13.3%, 44.6%, and 0%~8.7% lighting energy reductions compared to Case 1, Case 2, and Case 3, respectively. 5) Based on the above results, Case 4 suggested in the present study was found to be effective for indoor light environment improvement and lighting energy reduction.

Approaching obesity through constitutional therapy: a series of 4 obesity cases who were classified as the Taeeum constitutional type (태음인(太陰人) 병증(病證) 분류(分類)에 근거한 비만환자 치험 4례)

  • Pak, Yun-Seong;Shin, Hyun-Sang;Lee, Jun-Hee;Lee, Eui-Ju;Koh, Byung-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.23 no.2
    • /
    • pp.263-274
    • /
    • 2011
  • 1. Objectives: We report a series of 4 obesity cases who responded well to the weight-loss therapy based on the Taeeum Sasang constitutional therapy. 2. Methods: In treating 4 obese patients who were constitutionally typed as the Taeeum type, Case 1 and Case 2 fell into the category of the Lung Dry-Cold symptomatology, Case 3 into the Dry-Heat symptomatology, and Case 4 into the Exterior-Interior Combined symptomatology. Each patient was given Sasang medication according to protocol: Taeeumjowi-tang (Taiyintiaowei-tang) to Case 1 and Case 2, Cheongpyesagan-tang (Qingfeixiegan-tang) to Case 3, and Seunggijowi-tang (Chengqitiaowei-tang) to Case 4. On each visit to the clinic (7-21 times in total), the patients were checked on their general condition and change in body weight. 3. Results and Conclusions: All patients showed improvements in their general condition and a satisfactory decrease in weight (Case 1 showed a decrease of 12.7 kg in 84 days, Case 2 a decrease of 8.9 kg in 39 days, Case 3 a decrease of 33 kg in 250 days, and Case 4 a decrease of 29.3 kg in 155 days). Treating obesity based on Taeeum constitutional therapy was found to be effective for weight loss and general improvement of health. The sustained effects of the therapy should be checked during the following visits. The obesity treatment protocol suggested in this investigation should be explored and verified in future studies.