• 제목/요약/키워드: Cascaded multilevel

검색결과 135건 처리시간 0.024초

Quick Diagnosis of Short Circuit Faults in Cascaded H-Bridge Multilevel Inverters using FPGA

  • Ouni, Saeed;Zolghadri, Mohammad Reza;Rodriguez, Jose;Shahbazi, Mahmoud;Oraee, Hashem;Lezana, Pablo;Schmeisser, Andres Ulloa
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.56-66
    • /
    • 2017
  • Fast and accurate fault detection is the primary step and one of the most important tasks in fault tolerant converters. In this paper, a fast and simple method is proposed to detect and diagnosis the faulty cell in a cascaded H-bridge multilevel inverter under a short circuit fault. In this method, the reference voltage is calculated using switching control pulses and DC-Link voltages. The comparison result of the output voltage and the reference voltage is used in conjunction with active cell pulses to detect the faulty cell. To achieve this goal, the cell which is active when the Fault signal turns to "0" is detected as the faulty cell. Furthermore, consideration of generating the active cell pulses is completely described. Since the main advantage of this method is its simplicity, it can be easily implemented in a programmable digital device. Experimental results obtained with an 11-level inverter prototype confirm the effectiveness of the proposed fault detection technique. In addition, they show that the diagnosis method is unaffected by variations of the modulation index.

전압 레벨 증가를 위한 Cascaded H-bridge 멀티레벨 인버터 개발 (Cascaded H-bridge Multilevel Inverter Scheme for Increasing Voltage Level)

  • 심현우;이준석;이교범;이대봉
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.496-497
    • /
    • 2014
  • 본 논문은 Cascaded H-bridge 멀티레벨 인버터의 출력 전압 레벨 수의 증가를 위한 모델과 스위칭 기법을 제안한다. 제안하는 모델은 기존의 Cascaded H-bridge 멀티레벨 인버터 구조에서 각 H-bridge 모듈의 출력단에 변압기를 연결하고, 변압기 2차측을 직렬로 연결한 모델이다. 이 구조에서 다수의 변압기의 턴비는 동일하고, 1개의 변압기 턴비만이 다른 턴비를 갖게된다. 따라서 1개의 변압기 턴비를 조절하여 출력전압의 전압 레벨수를 증가시킬 수 있다. 스위칭 방법은 기존에 멀티레벨 인버터에서 주로 사용되는 Level-shifted PWM 방식을 이용하여 간단하게 구현할 수 있다. 제안하는 모델의 검증을 위하여 시뮬레이션을 수행하여 제안하는 모델의 타당성을 확인한다.

  • PDF

다중 반송파 정현 펄스폭 변조방식으로 제어되는 Cascaded H-bridge 멀티레벨 PWM 인버터의 스위칭 손실 저감을 위한 스위칭 패턴 (Switching pattern for decreasing switching loss in cascaded H-bridge multilevel PWM inverter controlled by sinusoidal pulse width modulation with multi-carrier waves)

  • 최진성;김기두;정보창;강필순
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.61-62
    • /
    • 2012
  • 본 논문에서는 다중 반송파 정현 펄스폭 변조방식으로 제어되는 Cascaded H-bridge 멀티레벨 PWM 인버터의 스위칭 손실 저감을 위한 스위칭 패턴을 제안한다. 부하 담당 전력이 상대적으로 큰 H-bridge 모듈의 스위치는 저주파의 기본 출력 전압 레벨을 형성하도록 동작시키며, 부하 담당 전력이 상대적으로 작은 H-bridge 모듈의 스위치는 고주파의 PWM 파형을 기본파에 가감하여 출력전압 파형이 사인파에 가까워지도록 스위칭 패턴을 형성한다. 본 논문에서는 제안된 스위칭 패턴을 PD, APOD 방식의 다중 반송파 정현 펄스폭 변조방식으로 구현하여 Cascaded H-bridge 멀티레벨 PWM 인버터에 적용시키고 실험을 통해 기존의 스위칭 패턴에 비해 스위칭 손실이 개선됨을 증명한다.

  • PDF

Identification of Open-Switch and Short-Switch Failure of Multilevel Inverters through DWT and ANN Approach using LabVIEW

  • Parimalasundar, E.;Vanitha, N. Suthanthira
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2277-2287
    • /
    • 2015
  • In recent times, multilevel inverters are given high priority in many large industrial drive applications. However, the reliability of multilevel inverters are mainly affected by the failure of power electronic switches. In this paper, open-switch and short-switch failure of multilevel inverters and its identification using a high performance diagnostic system is discussed. Experimental and simulation studies were carried out on five level cascaded H-Bridge multilevel inverter and its output voltage waveforms were analyzed at different switch fault cases and at different modulation index values. Salient frequency domain features of the output voltage signal were extracted using the discrete wavelet transform multi resolution signal decomposition technique. Real time application of the proposed fault diagnostic system was implemented through the LabVIEW software. Artificial neural network was trained offline using the Matlab software and the resultant network parameters were transferred to LabVIEW real time system. In the proposed system, it is possible to precisely identify the individual faulty switch (may be due to open-switch (or) short-switch failure) of multilevel inverters.

Cascaded H-bridge Multilevel Inverter for High Precision and Linear Control of the Rate of Ozone Yielding

  • Park, Sung-Jun;Kang, Feel-Soon
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.321-329
    • /
    • 2013
  • A multilevel inverter employing a cascade transformer is proposed for a silent-discharge-tube ozone generating system. The proposed inverter consists of four full-bridge inverters and fourteen transformers which have a series-connected secondary. It can accurately control the amplitude of the output voltage; hereby, it improves a linear characteristic of the rate of ozone yielding. The power regulation characteristics and operational principle of the proposed system are explained from a practical point of view. High precision ozone generating performance of the proposed multilevel inverter is verified by computer-aided simulations and experiment results.

A Novel DC Bus Voltage Balancing of Cascaded H-Bridge Converters in D-SSSC Application

  • Saradarzadeh, Mehdi;Farhangi, Shahrokh;Schanen, Jean-Luc;Frey, David;Jeannin, Pierre-Olivier
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.567-577
    • /
    • 2012
  • This paper introduces a new scheme to balance the DC bus voltages of a cascaded H-bridge converter which is used as a Distribution Static Synchronous Series Compensator (D-SSSC) in electrical distribution network. The aim of D-SSSC is to control the power flow between two feeders from different substations. As a result of different cell losses and capacitors tolerance the cells DC bus voltage can deviate from their reference values. In the proposed scheme, by individually modifying the reference PWM signal for each cell, an effective balancing procedure is derived. The new balancing procedure needs only the line current sign and is independent of the main control strategy, which controls the total DC bus voltages of cascaded H-bridge. The effect of modulation index variation on the capacitor voltage is analytically derived for the proposed strategy. The proposed method takes advantages of phase shift carrier based modulation and can be applied for a cascaded H-bridge with any number of cells. Also the system is immune to loss of one cell and the presented procedure can keep balancing between the remaining cells. Simulation studies and experimental results validate the effectiveness of the proposed method in the balancing of DC bus voltages.

Design and Research on High-Reliability HPEBB Used in Cascaded DSTATCOM

  • Yang, Kun;Wang, Yue;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.830-840
    • /
    • 2015
  • The H-bridge inverter is the fundamental power cell of the cascaded distribution static synchronous compensator (DSTATCOM). Thus, cell reliability is important to the compensation performance and stability of the overall system. The concept of the power electronics building block (PEBB) is an ideal solution for the power cell design. In this paper, an H-bridge inverter-based “plug and play” HPEBB is introduced into the main circuit and the controller to improve the compensation performance and reliability of the device. The section that discusses the main circuit primarily emphasizes the design of electrical parameters, physical structure, and thermal dissipation. The section that presents the controller part focuses on the principle of complex programmable logic device -based universal controller This section also analyzes typical reliability and anti-interference issues. The function and reliability of HPEBB are verified by experiments that are conducted on an HPEBB test-bed and on a 10 kV/± 10 Mvar DSTATCOM industrial prototype.

Cascaded H-bridge 멀티레벨인버터의 단일 입력전원 구동을 위한 Buck-boost와 Forward 기능을 갖는 컨버터 (Converter functioned Buck-boost and Forward operation for driving of Cascaded H-bridge multilevel inverter with a single input source)

  • 권철순;강필순
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.453-454
    • /
    • 2011
  • 본 논문에서는 벅-부스트와 포워드 컨버터의 기능을 갖는 컨버터를 제안한다. 제안하는 컨버터는 Cascaded H-bridge 멀티레벨인버터와 같이 다수의 독립된 전원을 요구하는 회로 구조를 단일 입력 전원단으로 구성할 수 있는 특징을 가진다. 벅-부스트 컨버터의 입력 인덕터는 변압기로 대체되며 컨버터 스위치의 ON 동작시 포워드 동작에 의해 변압기 2차측으로 전력전달이 이루어지며, 스위치 OFF시 변압기 1차측 자화인덕턴스에 저장된 에너지가 비절연된 벅-부스트 컨버터의 출력 커패시터로 전달된다. 제안된 컨버터의 동작 모드에 따른 이론적 분석을 시행하고 시뮬레이션을 통해 타당성을 검증한다.

  • PDF

Boost 컨버터와 Forward 컨버터의 조합을 이용한 Cascaded H-bridge 멀티레벨인버터 입력전원의 단일화 (Unification of Input Sources by combination of Boost and Forward converter in Cascaded H-bridge Multilevel Inverter)

  • 권철순;강필순
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.455-456
    • /
    • 2011
  • 본 논문에서는 Boost 컨버터와 Forward 컨버터를 조합한 컨버터를 제안한다. 제안하는 컨버터는 시스템 구성상 다수의 독립된 전원을 요구하는 Cascaded H-bridge 멀티레벨인버터와 같은 회로구조에 있어 다수의 독립전원의 확보가 곤란한 경우 단일 입력 전원단으로 시스템을 구성할 수 있는 특징을 가진다. Boost 컨버터의 입력 인덕터는 변압기로 대체되며 컨버터 스위치의 ON 동작시 변압기 일차측 자화인덕턴스에 저장된 에너지가 변압기 이차측과 비절연된 Boost 컨버터의 출력 커패시터로 전달된다. 제안된 컨버터의 동작 모드에 따른 이론적 분석을 시행하고 시뮬레이션을 통해 타당성을 검증한다.

  • PDF

Grid-Connected Photovoltaic System Based on a Cascaded H-Bridge Inverter

  • Rezaei, Mohammad-Ali;Iman-Eini, Hossein;Farhangi, Shahrokh
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.578-586
    • /
    • 2012
  • In this paper a single-phase Cascaded H-Bridge (CHB) inverter for photovoltaic (PV) applications is presented. Based on the presented mathematical analysis, a novel controller is introduced which adjusts the inverter power factor (PF) and manipulates the distribution of the reactive power between the cells to enhance the operating range of the CHB inverter. The adopted control strategy enables tracking of the maximum power point (MPP) of distinct PV strings and allows independent control of the dc-link voltages. The proposed controller also enables the inverter to operate under heavily unbalanced PV conditions. The performance of the CHB inverter and the proposed controllers are evaluated in the PSCAD/EMTDC environment. A seven-level CHB-based grid connected laboratory prototype is also utilized to verify the system performance.