• 제목/요약/키워드: Cascaded inverters

검색결과 71건 처리시간 0.021초

스텝 펄스파를 사용하는 캐스케이드 인버터에서 스위치의 간단한 도통각 계산법 (A Simple Method for Conducting Angle Calculation of Switch Devices in Cascaded Inverters Using Step Pulse Waves)

  • 김형창;김태진;강대욱;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.588-592
    • /
    • 2003
  • In recent years, the multilevel inverter synthesizing the output voltage with step pulse has been widely used as a solution for high power and high voltage applications. This paper proposes a simple method to obtain the conducting . angle. It is calculated by using voltage-second areas of the divided reference voltage according to the output voltage levels and these areas have influence on output step pulse waves. It is possible to reduce an amount of calculation because it is not required to solve the simultaneous equations by an iterative method. Also, the proposed method can get the conducting angle by means of on line.

  • PDF

두 대의 5-레벨 인버터의 직렬 결합을 이용한 멀티레벨 인버터 (Multilevel inverter using two 5-level inverters connected in series)

  • 최원균;홍운택;권철순;현석환;강필순
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.504-505
    • /
    • 2010
  • 본 논문에서는 양방향 스위치를 가지는 기존의 5-레벨 인버터를 직렬 결합하여 보다 많은 출력 전압 레벨을 형성할 수 있는 멀티레벨 인버터 구조를 제안한다. 제안된 회로는 동일한 출력 전압 레벨 형성시 기존의 Cascaded H-bridge cell 방식보다 사용하는 스위칭 소자를 줄일 수 있어 시스템 크기, 비용, 전력 손실을 저감시킬 수 있는 장점을 가진다. 제안된 회로는 입력 전압원의 크기를 5의 배수로 구성함으로서 보다 많은 수의 레벨을 생성시킬 수 있는 특징을 가진다. 본 논문에서는 두 대의 5-레벨 인버터를 직렬 결합함으로써 25-레벨의 출력전압을 생성시킬 수 있는 인버터에 대한 특성을 분석하고 시뮬레이션과 실험을 통해 타당성을 검증한다.

  • PDF

하프ㆍ풀-브리지 셀을 이용한 독립형 태양광 멀티레벨 인버터 (Half and Full-Bridge Cell based Stand-Alone Photovoltaic Multi-Level Inverter)

  • 강필순;오석규;박성준;김장목;김철우
    • 전력전자학회논문지
    • /
    • 제9권5호
    • /
    • pp.438-447
    • /
    • 2004
  • 본 논문에서는 하프ㆍ풀-브리지 셀을 이용하는 새로운 멀티레벨 인버터를 제안하고 독립형 태양광 인버터로서의 가능성을 평가한다. 기본 회로 구조는 기존의 11-레벨형 PWM 인버터에 기초하며 세 개의 풀-브리지 모듈 중 하나의 모듈을 하프-브리지 구조로 대체한다. 이 간단한 회로 구조의 변경으로 제안된 멀티레벨 인버터는 세 가지의 장점을 가지게 된다. 첫째, 출력 전압 레벨 수의 증가를 통해 보다 정현적인 출력 전압 파형을 형성 시킬 수 있다. 둘째, 풀-브리지 모듈 대신 하프-브리지 셀을 이용하므로 두 개의 전력 스위치를 줄일 수 있다. 셋째, 쵸핑용으로 이용되는 인버터와 결합된 변압기에 의해 부하로 전달되는 전력량을 저감 시킬 수 있어 전체 효율 개선에 유리하다. 즉, 대부분의 전력은 저주파 스위칭 동작으로 기본 출력전압을 형성하는 인버터와 이와 결합된 변압기에 의해 부하단으로 전달되고, 고주파 스위칭을 하는 쵸핑용 인버터와 이와 결합된 변압기를 통한 출력은 최종 출력전압을 보다 정현화 하기 위한 목적으로 사용되도록 한다. 기존의 11-레벨형 PWM 인버터와 비교를 통해 제안하는 인버터를 평가하고, 컴퓨터 시뮬레이션 및 실험 결과를 통해 독립형 태양광 인버터로서의 가능성을 입증한다.

고조파 저감을 위한 단상 NPC 멀티레벨 PWM 인버터의 LC트랩 필터 설계 (LC Trap Filter Design of Single Phase NPC Multi-Level PWM Inverters for Harmonic Reduction)

  • 김윤호;이재학;김수홍
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.313-320
    • /
    • 2006
  • 본 논문에서는 단상 NPC 멀티레벨 인버터의 출력단 고조파 저감을 위한 LC 트랩 필터의 설계 방법을 제시하였고, 출력전압 THD와 출력전류 고조파 FFT 분석을 수행하였다. 제시된 LC 트랩 필터는 일반적인 LCR 필터와 종속 접속된 구조를 가지며, 스위칭 주파수에 동조되었다. 인버터 시스템은 고전력 응용에 적합한 NPC 멀티레벨 인버터를 사용하였으며, 제어기는 DSP(TMS320C31)을 사용하여 구성하였다. 제안된 시스템의 효용성은 시뮬레이션과 실험 결과를 통하여 증명하였다.

Harmonic Optimization Techniques in Multi-Level Voltage-Source Inverter with Unequal DC Sources

  • Aghdam, M. Ghasem Hosseini;Fathi, S. Hamid;Gharehpetian, Gevorg B.
    • Journal of Power Electronics
    • /
    • 제8권2호
    • /
    • pp.171-180
    • /
    • 2008
  • One of the major problems in electric power quality is the harmonic contents. There are several methods of indicating the quantity of harmonic contents. The most widely used measure is the total harmonic distortion (THD). Various switching techniques have been used in static converters to reduce the output harmonic content. This paper presents and compares the two harmonic optimization techniques, known as optimal minimization of the total harmonic distortion (OMTHD) technique and optimized harmonic stepped-waveform (OHSW) technique used in multi-level inverters with unequal dc sources. Both techniques are very effective and efficient for improving the quality of the inverter output voltage. First, we describe briefly the cascaded H-bridge multi-level inverter structure. Then, we present the switching algorithm for the inverter based on OHSW and OMTHD techniques. Finally, the results obtained for the two techniques are analyzed and compared. The results verify the effectiveness of the both techniques in multi-level voltage-source inverter with non-equal dc sources, clarifying the advantages of each technique.

불평형부하를 가지는 다단 H-bridge STATCOM에서 상간 직류전압 불평형의 제어 (Control of DC-side Voltage Unbalance among Phases in Multi-level H-Bridge STATCOM with Unbalanced Load)

  • 권병기;정승기;김태형
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.332-341
    • /
    • 2014
  • A cascaded H-bridge multi-level STATCOM(STATic synchronous COMpensator), which is composed of many cell inverters with independent dc-sources, generates inevitably dc-side voltage unbalance among phases when it compensates unbalanced load. It comes from the difference of flowing active power in each phase when this compensator makes negative-sequence current to eliminate the unbalance of source-side current. However, this unbalance can be controlled by injecting zero-sequence current which is decoupled with grid currents, so the compensator can work well during this balancing process. Both a feedback control algorithm, which produces zero-sequence current proportional to dc-side voltage unbalance within each phase, and a feedforward control algorithm, which makes zero-sequence current directly from the compensator's negative-sequence current, were proposed. The dc-side voltage of each phase can be controlled stably by these proposed algorithms in both steady-state and transient, so the compensator can have fast response to satisfy control performance under rapid changing load. These balancing controllers were implemented and verified via simulation and experiment.

Design and Application of a Photovoltaic Array Simulator with Partial Shading Capability

  • Beser, Ersoy
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1259-1269
    • /
    • 2019
  • PV system performance is dependent on different irradiations and temperature values in addition to the capability of the employed PV inverter / maximum power point tracker (MPPT) circuit or algorithm. Therefore, it would be appropriate to use a PV simulator capable of producing identical repeatable conditions regardless of the weather to evaluate the performance of inverter / MPPT circuits and algorithms. In accordance with this purpose, a photovoltaic (PV) array simulator is presented in this paper. The simulator is designed to generate current-voltage (I-V) and power-voltage (P-V) curves of a PV panel. Series connected cascaded modules constitute the basic part of the simulator. This feature also allows for the modeling of PV arrays since the number of modules can be increased and high voltage values can be reached with the simulator. In addition, the curves obtained at the simulator output become similar to the actual curves of sample PV panels with an increase in the number of modules. In order to show the validity of the proposed simulator, it was simulated for various situations such as panels under full irradiance and partial shading conditions. After completing simulations, experiments were realized to support the simulation study. Both simulation and experimental results show that the proposed simulator will be very useful for researchers to carry out PV studies under laboratory conditions.

A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1513-1525
    • /
    • 2016
  • Rapid and accurate phase synchronization is critical for the reliable control of grid-tied inverters. However, the commonly used software phase-locked loop methods do not always satisfy the need for high-speed and accurate phase synchronization under severe grid imbalance conditions. To address this problem, this study develops a novel open-loop phase locking scheme based on a synchronous reference frame. The proposed scheme is characterized by remarkable response speed, high accuracy, and easy implementation. It comprises three functional cascaded blocks: fast orthogonal signal generation block, fast fundamental-frequency positive sequence component construction block, and fast phase calculation block. The developed virtual orthogonal signal generation method in the first block, which is characterized by noise immunity and high accuracy, can effectively avoid approximation errors and noise amplification in a wide range of sampling frequencies. In the second block, which is the foundation for achieving fast phase synchronization within 3 ms, the fundamental-frequency positive sequence components of unsymmetrical grid voltages can be achieved with the developed orthogonal signal construction strategy and the symmetrical component method. The real-time grid phase can be consequently obtained in the third block, which is free from self-tuning closed-loop control and thus improves the dynamic performance of the proposed scheme. The proposed scheme is adaptive to severe unsymmetrical grid voltages with sudden changes in magnitude, phase, and/or frequency. Moreover, this scheme is able to eliminate phase errors induced by harmonics and random noise. The validity and utility of the proposed scheme are verified by the experimental results.

Wind Power Grid Integration of an IPMSG using a Diode Rectifier and a Simple MPPT Control for Grid-Side Inverters

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제10권5호
    • /
    • pp.548-554
    • /
    • 2010
  • In this paper, a 1.5 kW Interior Permanent Magnet Synchronous Generator (IPMSG) with a power conditioner for the grid integration of a variable-speed wind turbine is developed. The power-conditioning system consists of a series-type 12-pulse diode rectifier powered by a phase shifting transformer and then cascaded to a PWM voltage source inverter. The PWM inverter is utilized to supply sinusoidal currents to the utility line by controlling the active and reactive current components in the q-d rotating reference frame. While the q-axis active current of the PWM inverter is regulated to follow an optimized active current reference so as to track the maximum power of the wind turbine. The d-axis reactive current can be adjusted to control the reactive power and voltage. In order to track the maximum power of the wind turbine, the optimal active current reference is determined by using a simple MPPT algorithm which requires only three sensors. Moreover, the phase angle of the utility voltage is detected using a simple electronic circuit consisting of both a zero-crossing voltage detecting circuit and a counter circuit employed with a crystal oscillator. At the generator terminals, a passive filter is designed not only to decrease the harmonic voltages and currents observed at the terminals of the IPMSG but also to improve the generator efficiency. The laboratory results indicate that the losses in the IPMSG can be effectively reduced by setting a passive filter at the generator terminals.

200MW 석탄화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용 (Field Application of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan)

  • 김봉석;류호선
    • 전력전자학회논문지
    • /
    • 제12권5호
    • /
    • pp.424-431
    • /
    • 2007
  • 본 논문은 발전소의 이차공기송풍기를 가변 회전수 제어하여 소내 소비 전력을 절감하고 전동기의 직입기동에 의한 스트레스를 줄이기 위하여 실증 적용된 200MW 석탄화력 발전소 순환 유동층 보일러 이차 공기 송풍기 구동용 H-브릿지 멀티레벨 인버터에 관한 것이다. H-브릿지 멀티레벨 인버터는 독립적으로 절연된 직류 부를 갖는 저전압의 단상 인버터(셀 인버터)를 다수 직렬 접속하여 고전압 3상 전압을 출력하는 Cascaded H-브릿지 전압형 인버터이다. 전력연구원은 6.6kV, 1MVA급 인버터 개발, 발전소에 설치, 보일러 점화 전/후 시험 및 계통 병입 후 부하 시험 등을 국내 최초로 성공적으로 완료하였다. 현재 200MW 석탄화력 발전소 이차 공기 송풍기 구동용 인버터는 상업 운전 중에 있다. 본 논문에서는 개발된 H-브릿지 멀티레벨 인버터, 기존 발전 설비와 신규 인버터 시스템의 인터페이스 부분에 해당하는 보일러 DCS(Distributed Control System : 분산 제어 시스템) 로직, 계통 병입 후 시운전 결과에 대하여 상세히 기술하였다.