• Title/Summary/Keyword: Carrier detection

Search Result 286, Processing Time 0.024 seconds

Development of Smart Carrier with Weight Sensing and Alarm System (무게 감지와 경보시스템을 갖춘 스마트 캐리어 개발)

  • Cho, Jun-Su;Kim, Seung-Kyum;Seo, Dong-Seop;Kwak, Se-Young;Kim, Jae-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.317-324
    • /
    • 2022
  • In this thesis, in consideration of the functions of general carriers, smart carriers with various convenience functions were studied for supplementation and improvement based on the disadvantages of carriers and inconvenience when using them. Based on the app inventory program, LED and motor locks were installed in carriers through smartphone applications, Bluetooth recognition and control functions that easily control on/off, load cell sensors were installed inside the carriers to detect weight, install Bluetooth and alarms on LCD panels, and prevent theft and loss.

Simultaneous Analysis of 13 Pesticides in Groundwater and Evaluation of its Persistent Characteristics

  • Song, Dahee;Park, Sunhwa;Jeon, Sang-Ho;Kim, Ki-In;Hwang, Jong Yeon;Kim, Moonsu;Jo, Hun-Je;Kim, Deok-hyun;Lee, Gyeong-Mi;Kim, Hye-Jin;Kim, Tae-Seung;Chung, Hyen Mi;Kim, Hyun-Koo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.5
    • /
    • pp.434-451
    • /
    • 2017
  • For this study, groundwater samples for 3 years from 2011 through 2013 were collected at 106 groundwater monitoring site in Korea. These groundwater samples were analyzed for 13 pesticides such as cabofuran, pentachlorobenzene, hexachlorobenzene, simazine, atrazine, lindane (gamma-HCH), alachlor, heptachlor, chlordane (total), endosulfan (1, 2), dieldrin, endrin, 4,4-DDT. The objectives of this study were to determine the detection frequency and their concentrations of 13 pesticides and evaluate the health risk level considering ingestion, inhalation, and skin contact using concentrations of 13 pesticides in groundwater samples. An analysis was used for the simultaneous determination for 13 pesticides using GC-MS. GC-MS was performed on HP-5ms, using helium ($1ml\;min^{-1}$) as carrier gas. The average recoveries of the pesticides were from 92.8% to 120.8%. The limits of detection (LODs) were between $0.004{\mu}g\;L^{-1}$ and $0.118{\mu}g\;L^{-1}$ and the limits of quantification (LOQs) were between $0.012{\mu}g\;L^{-1}$ and $0.354{\mu}g\;L^{-1}$. 106 groundwater wells were selected. 54 wells were from well to monitor background groundwater quality and 52 wells were from well to monitor groundwater quality in industrial or contamination source area. Eight pesticides including pentachlorobenzene, lindane (Gamma-HCH), heptachlor, chlordane (total), Endosulfan (1, 2), dieldrin, endrin, and 4,4-DDT were not detected in groundwater samples. The detection frequency for hexachlorobenzene, alachlor, carbofuran and simazine was 23.4%, 11.4%, 7.3%, and 1.0%, respectively. Atrazine was detected once in 2011. The average concentrations were $0.00423{\mu}g\;L^{-1}$ for carbofuran, $0.000243{\mu}g\;L^{-1}$ for alachlor, $0.00015{\mu}g\;L^{-1}$ for simazine, and $0.00001{\mu}g\;L^{-1}$ for hexachlorobenzene. The detection frequency of hexachlorobenzene was high, but the average concentration was low. In the contaminated groundwater, the detection frequency for hexachlorobenzene, alachlor, carbofuran, simazine and atrazine was 26.1%, 21.3%, 7.1%, 1.9% and 0.3%, respectively. In the uncontaminated groundwater, detection frequency for hexachlorobenzene, carbofuran and alachlor were 20.2%, 7.5%, and 1.9% respectively. Simazine and atrazine were not detected at uncontaminated groundwater wells. According to the purpose of groundwater use, atrazine was detected for agricultural groundwater use. Hexachlorobenzene showed high detection frequency at agricultural groundwater use area where the animal feeding area and golf course area were located. Alachlor showed more than 50% detection frequency at cropping area, pollution concern river area, and golf course area. Atrazine was detected in agricultural water use area. By land use, the maximum detection frequency of alachlor was found near an orchard. For human risk assessment, the cancer risk for the 5 pesticides was between $10^{-7}$ and $10^{-10}$, while the non-cancer risk (HQ value) was between $10^{-4}$ and $10^{-6}$. For conclusion, these monitoring study needs to continue because of the possibility of groundwater contamination based on various purpose of groundwater use.

A TOA Shortest Distance Algorithm for Estimating Mobile Location (모바일 위치추정을 위한 TOA 최단거리 알고리즘)

  • Pradhan, Sajina;Hwang, Suk-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.12
    • /
    • pp.1883-1890
    • /
    • 2013
  • Location detection technology (LDT) is one of the core techniques for location based service (LBS) in wireless communication for improving resource management and quality of services. The location of a mobile station (MS) is estimated using the time of arrival (TOA) technique based on three circles with centers corresponding to coordinates of three base stations (BSs) and radius corresponding to distances between MS and BSs. For accurately estimating the location of MS, three circles should meet at a point for the trilateration method, but they generally do not meet a point because the radius is increased depending on the number of time delay for estimating the distance between MS and BS and the carrier frequency. The increased three circles intersect at six points and the three intersection points among them should be generally placed close to coordinate of the location for the specific MS. In this paper, we propose the shortest distance algorithm for TOA trilateration method, to select three interior intersection points from entire six points. The proposed approach selects three intersection points with the shortest distances between coordinates of MS and intersection points and determines the averaged coordinate of the selected three points, as the location of the specific MS. We demonstrate the performance of the proposed algorithm using a typical computer simulation example.

Genetic Monitoring of Plant Growth Promoting Rhizobacterium (PGPR), Bacillus subtilis AH18 using Multiplex PCR in Field Soil (Multiplex PCR을 이용한 생물방제균 Bacillus subtilis AH18의 토양내 Genetic Monitoring)

  • Woo, Sang-Min;Lim, Jong-Hui;Jeong, Hee-Young;Kim, Sang-Dal
    • Microbiology and Biotechnology Letters
    • /
    • v.37 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • The genetic monitoring method was developed for the rapid detection of the PGPR and biocontrol agent, B. subtilis AH18 in red-pepper field soil by multiplex PCR using sid, aec and cel gene primers. The monitoring of B. subtilis AH18 in the soil was carried by amplified a 2,3-dihydro-2,3-dihydroxy benzoate dehydrogenase [EC: 1. 3. 1. 28]gene (sid - 794 bp : EF408238) which is a key enzyme of siderophore synthesis, an auxin efflux carrier gene (aec - 1,052 bp : EF408239) and a cellulase gene (cel - 1,582 bp : EF070194). The natural un sterilized soil was inoculated with B. subtilis AH18 to determine the sensitivity ($1.8\times10^5$ cfu/g) of multiplex PCR for the rapid dectection and then the strain was monitored successfully in rhizosphere or non-rhizosphere soil of red-pepper cultural soil. At 3 weeks after the treatment, density of the strain was monitored more abundantly in rhizosphere soil.

A study on Parallel Interference Cancellation scheme based sorting method for a Multi-carrier DS/CDMA System (MC-DS/CDMA 시스템에서 정렬기법을 이용한 병렬형 간섭제거기법의 성능개선에 관한 연구)

  • Park Jae-Won;Park Yong-Wan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.1
    • /
    • pp.17-27
    • /
    • 2005
  • In this paper, we introduce a Parallel Interference Canceller (PIC) based sorting method to improve performance in the MC-DS/CDMA environment. A conventional PIC estimates and subtracts out all of the MAI (Multiple Access Interference) for each user in parallel. The parallel process ensures the low delay for the detection of all users. Also this scheme requires more stages for having better performance. Since the performance of PIC is strongly related to the correct MAI estimation, we introduce the IC (Interference Cancellation) scheme to estimate the accurate weaker signal group than the desired signal using conventional PIC. The principle of the proposed receiver sorts in descending order by the strength of signal and subtracts the MAI of the strong interferers from the desired signal for the accurate estimate of the weaker signals. Following this, the proposed scheme cancels out the improved weaker interference from the desired signal, using the output of the pre-step. In this result, the proposed system obtains better BER performance than the conventional PIC because the accuracy of the strong signal is improved. However, a disadvantage exists in that the processing time has slightly longer delay than the PIC owing to the power sorting and the MAI estimation process. The system performance evaluates and compares other non-liner It according to the number of sub-carriers in the limited-bandwidth.

Determination of Copper in Black, Red Pepper and the Waste Water Samples by a Highly Selective Sensitive Cu(II) Microelectrode Based on a New Hexadentates Schiff's Base

  • Norouzi, Parviz;Ganjali, Mohammad Reza;Faridbod, Farnoush;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1439-1444
    • /
    • 2006
  • A $Cu^{2+}$ ion-selective membrane microelectrode has been fabricated from poly vinyl chloride (PVC) matrix membrane containing a new symmetrical hexadentate Schiff,s base 2-{1-(E)-2-((Z)-2-{(E)-2-[(Z)-1-(2-hydroxyphenyl)ethylidene]hydrazono}-1-methylpropylidene)hydrazono]ethyl}phenol (HDNOS) as a neutral carrier, Potassium tetrakis(4-chlorophenyl) borate (KTpClPB) as an anionic excluder and o-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The microelectrode displays linear potential response in the concentration range of $1.0\;{\times}\;10^{-5}-1.0\;{\times}\;10^{-11}$ M of $Cu^{2+}$. The microelectrode exhibits a nice Nernstian slope of 25.9 ${\pm}$ 0.3 mV $decade^{-1}$ in the pH range of 3.1-8.1. The sensor has a relatively short response time in whole concentration ranges ($\sim$5 s). The detection limit of proposed sensor is $5.0\;{\times}\;10^{-12}$ M (320 pg/L), and it can be used over a period of eight weeks. The practical utility of the sensor has been demonstrated by using it as an indicator electrode in the potentiometric titration of $Cu^{2+}$ with EDTA. The proposed membrane electrode was used for the direct determining of $Cu^{2+}$ content in black and red pepper, and in waste water samples.

A Study on the Determination of$N(NO_2^-),\;N(NO_3^-)$and$N(NH_4^+)$in Environmental Samples by Flow Injection Analysis (흐름주입분석법에 의한 환경시료 중$N(NO_2^-),\;N(NO_3^-)$$N(NH_4^+)$의 정량분석에 관한 연구)

  • Rhee, Jae Seong;Kim, Young Sang;Jung, Yun Hee;Rhee, Hee Jung
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.5
    • /
    • pp.256-265
    • /
    • 1997
  • A rapid and sequential method was studied, which can determine nitrite, nitrate and ammonium ion in soil or water samples with flow injection analysis. Geometric factors including injection volume, length of the reaction coil and flow rate of carrier solution were investigated prior to sample measurement. Nitrite was determined at 540 nm by Griess reaction producing azo dye between N-(1-naphthylethylenediamine dihydrochloride) and sulfanilamide. Nitrate was also measured under the help of reduction mechanism toward nitrite with hydrazine. Ammonium was analyzed at 440 nm with Nessler's reagent. At the optimum condition, the detection limit(S/N=3) has been shown 0.1 ㎍/mL N(NO2-), 0.4 ㎍/mL N(NO3-) and 0.3 ㎍/mL N(NH4+) respectively. The results measured by colorimetry, ion chromatography and FIA were compared showing 80%-125% reasonable match each other. Injection throughput rate could be performed better than 30 times per hour.

  • PDF

Implementation of An 1.5Gbit/s Wireless Data Transmission System at 300GHz Band (300GHz 대역 1.5Gbit/s 무선 데이터 전송 시스템 구현)

  • Lee, Won-Hui;Chung, Tae-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.1-6
    • /
    • 2011
  • In this paper, an 1.5Gbit/s wireless data transmission system using the carrier frequency of 300 GHz band was implemented. The RF front-end was composed of schottky diode sub-harmonic mixer, frequency tripler, and horn antennas for transmitter and receiver, respectively. The LO frequencies of sub-harmonic mixer are 150GHz for transmit chain and 156GHz for receive chain. The ASK(Amplitude Shift Keying) modulation was used in the transmitter and the envelope detection method was used in the heterodyne receiver. The conversion loss of sub-harmonic mixer and implementation system loss were measured to be 9.8dB and 1.2dB, respectively. The 1.5Gbit/s video signal with HD-SDI format was transmitted over wireless distance of 40cm without optical lens(4.2m with optical lens) and displayed on HDTV at the transmitted average output power of $20{\mu}W$.

Sub-Micro Molar Monitoring of La3+ by a Novel Lanthanum PVC-Based Membrane Sensor Based on 3-Hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide

  • Ganjali, Mohammad Reza;Norouzi, Parviz;Yousefian, Nasrin;Faridbod, Farnoush;Adib, Mehdi
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1581-1586
    • /
    • 2006
  • A La (III) ion-selective membrane sensor has been fabricated from poly vinyl chloride (PVC) matrix membrane, containing 3-hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide (HPMN) as a neutral carrier, potassium tetrakis (p-chlorophenyl) borate (KTpClPB) as an anionic excluder and ortho-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The effects of membrane composition and pH as well as the influence of the anionic additive on the response properties were investigated. The sensor with 30% PVC, 62% solvent mediator, 6% ionophore and 2% anionic additive, shows the best potentiometric response characteristics. It displays a Nernstian behavior (19.2 mV per decade) across the range of $1.0{\times}10^{-2}-1.0{\times}10^{-7}$ M. The detection limit of the electrode is $7.0{\times}10^{-8}$ M ($\sim$10 ng/mL) and the response time is 15 s from $1.0{\times}10^{-2}$ up to $1.0{\times}10^{-4} $M and 30 s in the range of $1.0 {\times}10^{-5}-1.0{\times}10^{-7}$ M. The sensor can be used in the pH values of 3.0-9.0 for about seven weeks. The membrane sensor was used as an indicator electrode in the potentiometric titration of lanthanum ions with EDTA. It was successfully applied to the lanthanum determination in some mouth wash preparations.

A Development of Ultrasonic Based Distance Meter Through Detachment of Receiving and Transmitting Capacitive Ultrasonic Transducer (송.수신 분리형 초음파 거리 측정기 개발)

  • Kim Jung-Hoon;Chong Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.41-50
    • /
    • 2006
  • This paper presents a novel ultrasonic sensor system to overcome limited distance detection range that can be measured only more than 30cm by single ultrasonic transducer. This is accomplished by separation of receiving capacitive ultrasonic transducer from transmitting capacitive ultrasonic transducer. And hardwares and software of the system are described in detail. The system makes very close range as well as long range detect by wireless precisely. Frequency of trigger pulse is 10Hz, but it is very low frequency for transmitting data in wireless module. Therefore, for triggering between receiver and transmitter, an algorithm for mixing and distinguishing trigger pulse from carrier pulse by software is proposed. The system is designed by common microprocessor 8051. The performance of the proposed method has been assessed through two types. The first, transmitting and receiving transducer are put on both sides. And then, distance of two point is measured as far as 0mm. Secondly, transmitting transducer send out ultrasonic pulse and measure the time of flight(TOF) until a first echo from an object detected by the detached receiving transducer. The distance between the detached transducers and a reflecting object is measured as far as 7cm. Images of measured ultrasonic waves and TOF for two methods presented to prove effectiveness of results.