• 제목/요약/키워드: Carbon Nanotube based Sensor

검색결과 66건 처리시간 0.03초

나노 센서를 이용한 구조물 건전성 감시 기법 (Structural Heal th Monitoring Based On Carbon Nanotube Composite Sensors)

  • 강인필;이종원;최연선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.613-619
    • /
    • 2006
  • This paper introduces a new structural health monitoring using a nano sensor. The sensor is made of nano smart composite material based on carbon nanotubes. The nano sensor is fabricated as a thin and narrow polymer film sensor that is bonded or deposited onto a structure. The electrochemical impedance and dynamic strain response of the neuron change due to deterioration of the structure where the sensor is located. A network of the long nano sensorcan form a structural neural system to provide large area coverage and an assurance of the operational health of a structure without the need for actuators and complex wave propagation analyses that are used with other methods.

  • PDF

Electrochemical Determination of Bisphenol A at Carbon Nanotube-Doped Titania-Nafion Composite Modified Electrode

  • Kim, Byung Kun;Kim, Ji Yeon;Kim, Dong-Hwan;Choi, Han Nim;Lee, Won-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1065-1069
    • /
    • 2013
  • A highly sensitive electrochemical detection method for bisphenol A (BPA) has been developed by using multi-walled carbon nanotube (CNT)-doped titania-Nafion composite modified glassy carbon (GC) electrode. The CNT-titania-Nafion/GC electrode exhibited excellent electrocatalytic activity towards BPA. Therefore, the CNT-titania-Nafion/GC electrode showed improved voltammetric responses for BPA compared to that obtained with bare GC electrode. In addition, cetyltrimethylammonium bromide (CTAB), a cationic surfactant, was added into the BPA sample solution in order to accumulate BPA through hydrophobic interaction between CTAB and BPA. The CNT-titania-Nafion/GC electrode gave a linear response ($r^2$ = 0.999) for BPA from $1.0{\times}10^{-8}$ M to $5.0{\times}10^{-6}$ M with a detection limit of $9.0{\times}10^{-10}$ M (S/N = 3). The modified electrode showed good selectivity against interfering species and also exhibited good reproducibility. The present electrochemical sensor based on the CNT-titania-Nafion/GC electrode was applied to the determination of BPA in food package samples.

Carbon-Nanotube-Modified Glass Micropipette for Simultaneous Drug Injection and Neural Monitoring

  • Shin, Jung Hwal;Kim, Geon Hwee;Kim, Intae;Lim, Hoon;Lim, Geunbae
    • 센서학회지
    • /
    • 제22권5호
    • /
    • pp.309-314
    • /
    • 2013
  • Glass micropipettes are widely used for drug injection in neurological studies. To enable these devices to monitor neural activity simultaneously with drug injection, an electrode such as Ag/AgCl must be located near or inserted into the glass micropipette to detect electrical signals in vivo. Here, we report carbon-nanotube-modified glass micropipettes (CNGs), which have excellent electrochemical properties such as low impedance and large electrochemical surface area suited for neural recording. In addition, using a standard pressure pump, CNGs can deliver drugs to the target region without bending. Because they are based on standard glass micropipettes, CNGs can readily be applied to traditional equipment, creating opportunities to monitor precisely the drug-injected area.

3D 프린팅을 이용한 Pt/Carbon Nanotube composite 기반 전기화학식 황화수소 가스 센서 제작 (Fabrication of Pt/Carbon Nanotube Composite Based Electrochemical Hydrogen Sulfide Gas Sensor using 3D Printing)

  • 하윤태;권진범;최수지;정대웅
    • 센서학회지
    • /
    • 제32권5호
    • /
    • pp.290-294
    • /
    • 2023
  • Among various types of harmful gases, hydrogen sulfide is a strong toxic gas that is mainly generated during spillage and wastewater treatment at industrial sites. Hydrogen sulfide can irritate the conjunctiva even at low concentrations of less than 10 ppm, cause coughing, paralysis of smell and respiratory failure at a concentration of 100 ppm, and coma and permanent brain loss at concentrations above 1000 ppm. Therefore, rapid detection of hydrogen sulfide among harmful gases is extremely important for our safety, health, and comfortable living environment. Most hydrogen sulfide gas sensors that have been reported are electrical resistive metal oxide-based semiconductor gas sensors that are easy to manufacture and mass-produce and have the advantage of high sensitivity; however, they have low gas selectivity. In contrast, the electrochemical sensor measures the concentration of hydrogen sulfide using an electrochemical reaction between hydrogen sulfide, an electrode, and an electrolyte. Electrochemical sensors have various advantages, including sensitivity, selectivity, fast response time, and the ability to measure room temperature. However, most electrochemical hydrogen sulfide gas sensors depend on imports. Although domestic technologies and products exist, more research is required on their long-term stability and reliability. Therefore, this study includes the processes from electrode material synthesis to sensor fabrication and characteristic evaluation, and introduces the sensor structure design and material selection to improve the sensitivity and selectivity of the sensor. A sensor case was fabricated using a 3D printer, and an Ag reference electrode, and a Pt counter electrode were deposited and applied to a Polytetrafluoroethylene (PTFE) filter using PVD. The working electrode was also deposited on a PTFE filter using vacuum filtration, and an electrochemical hydrogen sulfide gas sensor capable of measuring concentrations as low as 0.6 ppm was developed.

탄소나노튜브 기반 벌크 소재의 전기적 임피던스 특성을 이용한 생화학 센서용 전극 개발 연구 (Preparation of Bio-Chemical Sensor Electrodes by Using Electrical Impedance Properties of Carbon Nanotube Based Bulk Materials)

  • 소대섭;허훈;김희진;이해원;강인필
    • 공업화학
    • /
    • 제21권5호
    • /
    • pp.495-499
    • /
    • 2010
  • 본 연구에서는 대량 생산 가능한 센서 전극의 생화학 센서 전극 개발을 위하여 탄소나노튜브(carbon nanotube, CNT)를 복합재료화 공정에 의하여 필름과 나노웹 형태의 벌크 재료로 제작한 후, 이들 전극의 넓은 표면적과 뛰어난 화학적 흡착성을 이용하여 화학적 검출 대상에 노출이 되었을 때 이들로 인한 센싱 특성을 연구하였다. CNT 기반 벌크 전극으로 제작하기 위하여 Nafion을 기저재료로 하는 필름과 PAN 기반의 나노 파이버를 전기방사법에 의하여 제작을 한 후 이들 전극의 화학적 영향에 의한 전기적인 특성 변화 실험을 위하여 버퍼 용액의 정전용량에 대한 전기적 임피던스 요소 값인 저항과 정전용량의 변화를 LCR 계측기로 측정하였다. 생화학센서용 전극으로서 CNT벌크전극의 임피던스 변화 형태가 복합소재 전극의 기저재료에 따라 달리 나타났으며 일정량의 버퍼용액 투여 후에는 변화가 없는 포화 상태의 응답을 보였으며 특히, 정전용량이 저항에 비하여 상대적으로 급격하게 큰 변화를 보여 높은 감도 특성을 지니고 있음이 조사되었다. 이들의 전기적인 특성변화는 버퍼 용액의 화학적 성분들이 전극에 흡수 된 후에 CNT에 흡착이 되어 이들의 전기적인 특성을 변화 시키는 것으로 추론된다.

스프레이코팅 방식으로 제작된 단일벽 탄소나노튜브막 스트레인센서 (Spray-coated single-wall carbon nanotube film strain sensor)

  • 박찬원
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.29-33
    • /
    • 2012
  • We demonstrated the viability of fully microfabricating SWCNT(single-wall carbon nanotube) film strain sensors for force and weight sensing. Our spray-deposited SWCNT film strain sensors showed good linearity over a range from 0 to 400 microstrain, and much higher sensitivity compared to commercial metal foil-type gauges. The number of grids and the thickness of the SWCNT film were found to have a significant effect on the strain sensing properties of the SWCNT film gauges. A strain sensing methode for the CNT-based strain gauges was also investigated using a binocular type beam load cells. Preliminary results indicate that the microfabrication method shown here is promising for developing a commercial strain gauge using a spray-coated SWCNT thin film. In the near future, various studies will be performed to further enhance the properties of the spray-coated SWCNT film strain sensors.

  • PDF

Preparation and characteristics of conducting polymer-coated multiwalled carbon nanotubes for a gas sensor

  • Jang, Woo-Kyung;Yun, Ju-Mi;Kim, Hyung-Il;Lee, Young-Seak
    • Carbon letters
    • /
    • 제12권3호
    • /
    • pp.162-166
    • /
    • 2011
  • Conducting polymer-coated multiwalled carbon nanotubes (MWCNTs) were prepared by template polymerization in order to enhance their gas sensitivity. This investigation of the conducting polymer phases that formed on the surface of the MWCNTs is based on field-emission scanning electron microscopy images. The thermal stability of the conducting polymer-coated MWCNTs was significantly improved by the high thermal stability of MWCNTs. The synergistic effects of the conducting polymer-coated MWCNTs improve the gas-sensing properties. MWCNTs coated with polyaniline uniformly show outstanding improvement in gas sensitivity to $NH_3$ due to the synergistic combination of efficient adsorption of $NH_3$ gas and variation in the conduction of electrons.

Surface and small scale effects on the dynamic buckling of carbon nanotubes with smart layers assuming structural damping

  • Farokhian, Ahmad;Salmani-Tehrani, Mehdi
    • Steel and Composite Structures
    • /
    • 제37권2호
    • /
    • pp.229-251
    • /
    • 2020
  • In this paper, dynamic buckling of a smart sandwich nanotube is studied. The nanostructure is composed of a carbon-nanotube with inner and outer surfaces coated with ZnO piezoelectric layers, which play the role of sensor and actuator. Nanotube is under magnetic field and ZnO layers are under electric field. The nanostructure is located in a viscoelastic environment, which is assumed to obey Visco-Pasternak model. Non-local piezo-elasticity theory is used to consider the small-scale effect, and Kelvin model is used to describe the structural damping effects. Surface stresses are taken into account based on Gurtin-Murdoch theory. Hamilton principle in conjunction with zigzag shear-deformation theory is used to obtain the governing equations. The governing equations are then solved using the differential quadrature method, to determine dynamic stability region of the nanostructure. To validate the analysis, the results for simpler case studies are compared with others reported in the literature. Then, the effect of various parameters such as small-scale, surface stresses, Visco-Pasternak environment and electric and magnetic fields on the dynamic stability region is investigated. The results show that considering the surface stresses leads to an increase in the excitation frequency and the dynamic stability region happens at higher frequencies.