• Title/Summary/Keyword: Capillary performance

Search Result 233, Processing Time 0.033 seconds

Influence of Working Fluids to Heat Transfer Characteristics of Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery

  • Lee, Wook-Hyun;Im, Yong-Bin;Kim, Ju-Won;Kim, Jeung-Hoon;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.27-35
    • /
    • 2001
  • Heat transfer characteristics of a heat exchanged for low temperature waste heat recovery using oscillating capillary tube heat pipe (OCHP) were evaluated against the charging ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working a 2.6mm in outside diameter, 1.44mm in inside diameter with 101m length and 140 turns. Charging ratio of working fluid was 40% and 50%. water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and 9~27 $4kg/m^2s$, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-142b and R-290 and it was proportional to Figure of Merit for thermosyphon. As a result, it was thought that R-22 was the most reasonable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

An Experimental Stuff on the Performance of Multi-type Heat Pump using Capillary Tubes (모세관을 이용한 멀티형 열펌프의 신뢰성에 관한 실험적 연구)

  • 권영철;장근선;이윤수;김대훈;전용호;이상재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.749-755
    • /
    • 2002
  • In order to develop a multi-type heat pump system with two indoor units of non-uniform capacities, the optimum refrigerant circuit was developed using capillary tubes. The refrigerant circuit was composed of four main parts, a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The system characteristics of multi-type heat pump was investigated through the rating test and the reliability test, using the multi-type psy-chrometric calorimeter. The results of the rating test showed that the capacity of the multi-type heat pump was about 93% of the design value. In particular, the capacity of cooling single mode was about 13% higher than the design value, and the capacity of heating multi mode was about 5% higher than the design value. The reliability of the multi-type heat pump was verified by various reliability tests (overload, extension tube, freeze up, under/over charging, sweat, flood back). The optimal amount of refrigerant charge and compressor capacity were determined from the present work.

Determination of Recombinant Human Epidermal Growth factor (rhEGF) in a Pharmaceutical Preparation by Capillary Electrophoresis

  • Hwang, Kyung-Hwa;Lee, Kang-Woo;Kim, Chang-Soo;Han, Kun;Chung, Youn-Bok;Moon, Dong-Cheul
    • Archives of Pharmacal Research
    • /
    • v.24 no.6
    • /
    • pp.601-606
    • /
    • 2001
  • A simple assay method of recombinant human epidermal growth factor (rhEGF) in a pharmaceutical preparation was studied and validated by capillary electrophoresis (CE) using micellar electrokinetic chromatography (MEKC) techniques. Factors affecting the migration behavior and separation performances of the peptide; type of buffers pH, butler concentration, and concentration of sodium dodecyl sulfates (SDS) were investigated to optimize the analytical performance. CE was performed using running buffers 50.0 mM borate (pH 8.5) containing 12.5 mM SDS at 20 $mutextrm{V}$ of the applied voltage. Calibration curves for the rhEGF showed good linearity (r>0.999) over the wide dynamic range from 1.25 to $100{\mu\textrm{g}}/ml$. Sample analysis was performed by using standard addition method to eliminate the matrix effects of dosage vehicle. This method is assumed to be useful for quality control (QC) of various forms of pharmaceutical products of the peptide.

  • PDF

A Study on Manufacture and Performance Evaluation of a Loop Heat Pipe System with a Cylindrical Evaporator for IGBT Cooling (전력반도체 냉각을 위한 원통형 루프히트파이프 제작 및 성능 평가에 관한 연구)

  • Ki, Jae-Hyung;Ryoo, Seong-Ryoul;Sung, Byung-Ho;Kim, Sung-Dae;Choi, Jee-Hoon;Kim, Chul-Ju
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1710-1716
    • /
    • 2008
  • The Loop Heat Pipe (LHP) operates to pump the working fluid by means of the capillary force in a wick structure. Particularly, it is difficult to design and manufacture the evaporator consisted of a grooved container and a compensation chamber as well as the wick structure. This study is related to design and manufacture the grooved container coupled with wick structure, the properties of the wick structure such as the permeability, the porosity, and the maximum capillary pressure were measured to apply the cooling technology for Insulated Gate Bipolar Transistor (IGBT). The container of the LHP was manufactured by the electrical discharge process and the wick structure was sintered with the nickel particle by an axial-press apparatus with the pulse electronic discharge. As results, the properties of the wick were experimentally obtained about 60% of the porosity, 35kPa of the maximum capillary force and $1.53{\times}10-13m2$ of the permeability.

  • PDF

Analytical study on seepage behavior of a small-scale capillary barrier system under lateral no-flow condition

  • Byeong-Su Kim
    • Geomechanics and Engineering
    • /
    • v.35 no.1
    • /
    • pp.13-27
    • /
    • 2023
  • The model production for large-scale (lateral length ≥ 2.0 m) capillary barrier (CB) model tests is time and cost-intensive. To address these limitations, the framework of a small-scale CB (SSCB) model test under the lateral no-flow condition has been established. In this study, to validate the experimental methodology of the SSCB model test, a series of seepage analyses on the SSCB model test and engineered slopes in the same and additional test conditions was performed. First, the seepage behavior and diversion length (LD) of the CB system were investigated under three rainfall conditions. In the seepage analysis for the engineered slopes with different slope angles and sand layer thicknesses, the LD increased with the increase in the slope angle and sand layer thickness, although the increase rate of the LD with the sand layer thickness exhibited an upper limit. The LD values from the seepage analysis agreed well with the results estimated from the laboratory SSCB mode test. Therefore, it can be concluded that the experimental methodology of the SSCB model test is one of the promising alternatives to efficiently evaluate the water-shielding performance of the CB system for an engineered slope.

Development and performance evaluation of a low-cost custom-made extensional rheometer (저비용 수제 연신레오미터 개발 및 성능 평가)

  • Sihyun Kim;Hanbyeol Pak;Jeong-Hyun Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.110-118
    • /
    • 2023
  • Characterizing the extensional rheological properties of non-Newtonian fluids is crucial in many industrial processes, such as inkjet printing, injection molding, and fiber engineering. However, educational institutions and research laboratories with budget constraints have limited access to an expensive commercial extensional rheometer. In this study, we developed a custom-made extensional rheometer using a CO2 laser cutting machine and 3D printer. Furthermore, we utilized a smartphone with a low-cost microscopic lens for achieving a high spatial resolution of images. The aqueous polyethylene-oxide (PEO) solutions and a Boger fluid were prepared to characterize their extensional properties. A transition from a visco-capillary to an elasto-capillary regime was observed clearly through the developed rheometer. The extensional relaxation time and viscosity of the aqueous PEO solutions with a zero-shear viscosity of over 300 mPa·s could be quantified in the elasto-capillary regime. The extensional properties of the solutions with relatively small zero shear viscosity could be calculated using a smartphone's slow-motion feature with increasing temporal resolution of the images.

Development of a Micro pH-ISFET Probe for in vivo Measurements of the Ion Concentration in Blood (생체내의 혈중이온농도 예측을 위한 마이크로 pH-ISFET프로브의 개발)

  • Sohn, Byung-Ki;Lee, Jong Hyun;Lee, Kwang Man
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.1
    • /
    • pp.83-90
    • /
    • 1986
  • A micro pH-ISFET probe, which can be applied to the in vivo measurements of the hydrogen ion concentration in blood, has been developed, and a measuring system equiped with this probe also developed. The pH-ISFET has been fatricated by employing the techniques of integrated circuit fabrication. Two kinds of micro electrode formed around the sensing gate during the wafer process, and the other is a capillary type of Ag/AfCl/sat. KCI reduced in size. This capillary electrode has shown its good performance characteristics so far in the application with ISFET as well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and the capillary electrode were built together into a needle tip having 1 mm inner diameter. The chip size of a twin pH-ISFET is 0.8 mmx1.4 mm, the material of the sensing gate membrane is Si3N4, and the sensitivity of the developed probe is about 52mV/pH.

  • PDF

Flow Visualization of Oscillation Characteristics of Liquid and Vapor Flow in the Oscillating Capillary Tube Heat Pipe

  • Kim, Jong-Soo;Kim, Ju-Won;Jung, Hyun-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.10
    • /
    • pp.1507-1519
    • /
    • 2003
  • The two-phase flow patterns for both non-loop and loop type oscillating capillary tube heat pipes (OCHPs) were presented in this study. The detailed flow patterns were recorded by a high-speed digital camera for each experimental condition to understand exactly the operation mechanism of the OCHP. The design and operation conditions of the OCHP such as turn number, working fluid, and heat flux were varied. The experimental results showed that the representative flow pattern in the evaporating section of the OCHP was the oscillation of liquid slugs and vapor plugs based on the generation and growth of bubbles by nucleate boiling. As the oscillation of liquid slugs and vapor plugs was very speedy, the flow pattern changed from the capillary slug flow to a pseudo slug flow near the annular flow. The flow of short vapor-liquid slug-train units was the flow pattern in the adiabatic section. In the condensing section, it was the oscillation of liquid slugs and vapor plugs and the circulation of working fluid. The oscillation flow in the loop type OCHP was more active than that in the non-loop type OCHP due to the circulation of working fluid in the OCHP. When the turn number of the OCHP was increased, the oscillation and circulation of working fluid was more active as well as forming the oscillation wave of long liquid slugs and vapor plugs in the OCHP. The oscillation flow of R-142b as the working fluid was more active than that of ethanol and the high efficiency of the heat transfer performance of R -142b was achieved.

Functional Integration of Serial Dilution and Capillary Electrophoresis on a PDMS Microchip

  • Chang, Jun-Keun;Heo, Yun-Seok;Hyunwoo Bang;Keunchang Cho;Seok Chung;Chanil Chung;Han, Dong-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.233-239
    • /
    • 2003
  • For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.

Evaluation of Wettability and Interfacial Property of Glass Fiber Reinforced Composite with Different Glass Fiber Conditions via Capillary Effect (Capillary 특성을 활용한 섬유 조건에 따른 유리섬유강화 복합재료의 함침성 및 계면강도 평가)

  • Kim, Jong-Hyun;Kwon, Dong-Jun;Park, Joung-Man
    • Composites Research
    • /
    • v.34 no.5
    • /
    • pp.305-310
    • /
    • 2021
  • Mechanical properties of fiber reinforced composites were affected to fiber volume fractions (FVF) and interfacial property by sizing agent conditions. An optimum interface can relieve stress concentration by transferring the mechanical stress from the matrix resin to the reinforcements effectively, and thus can result in the performance of the composites. The interfacial properties and wettability between the epoxy resin and glass fiber (GF) were evaluated for different sizing agent conditions and FVFs. The surface energies of epoxy resin and different sizing agent treated GFs were calculated using dynamic and static contact angle measurements. The work of adhesion, Wa was calculated by using surface energies of epoxy matrix and GFs. The wettability was evaluated via the GF tow capillary test. The interfacial shear strength (IFSS) was evaluated by microdroplet pull-out test. Finally, the optimized GFRP manufacturing conditions could be obtained by using wettability and interfacial property.