• Title/Summary/Keyword: Capillary method

Search Result 508, Processing Time 0.103 seconds

Analysis of Ginseng Saponins by HPLC with Photoreduction Fluorescence Detection

  • Kim, Bae-Yuan;Lee, Mi-Young;Cho, Kyung-Hee;Park, Jeong-Hill;Park, Man-Ki
    • Archives of Pharmacal Research
    • /
    • v.15 no.4
    • /
    • pp.328-332
    • /
    • 1992
  • A new high performance liquid chromatographic procedure is described for the analysis of ginseng saponins. Ginseng saponins were separated on Lichrosorb $NH_2$ column and anthraquinone-2, 6-disulfonate (AQDS) solution was added to the column effluent. The effluent was passed through 1.5m-PTFE capillary coiled around 10 W-UV lamp to reduce AQDS to highly fluorescent 9. 10-dihydroxyanthracene-2, 6-disulfonate which was detected by fluorescence detector. The detection limit for the ginsenoside $Rg_1$ by this method was found to be about 350 ng, the dynamic linear range was $10^2$ and the correlation coefficient of the calibration curve was 0.9999.

  • PDF

Chiral Separation of $\beta$-Blockers after Derivatization with (-)-$\alpa$- Methoxy-$\alpa$-(trifuoromethyl)phenylacetyl Chloride by Gas Chromatography

  • Kim, Kyeong-Ho;Lee, Joo-Hyun;Ko, Mi-Young;Hong, Seon-Pyo;Youm, Jeong-Rok
    • Archives of Pharmacal Research
    • /
    • v.24 no.5
    • /
    • pp.402-406
    • /
    • 2001
  • Gas chromatographic method was investigated for the chiral separation of several $\beta$-blockeros(atenolol, betaxolol, bisoprolol, metoprolol and pindolol) using (-)-$\alpa$-methoxy-$\alpa$-(trifluoromethyl)phenylacetyl chloride as a chiral derivatizing agent for amino group. Prior to N-acylation, hydroxyl group was converted into O-silyl ethers by react with N-methyl-H-(taimethylsilyl)trifluoroacetamide. The reaction was selective and rapid and the diasteromeric derivatives were well separated by capillary gas chromatography. (R)-isomers were eluted faster than (S)-isomers when (-)-$\alpa$-methoxy-$\alpa$-(trifluoromethyl)phenylacetyl chloride was used as the chiral derivatizing agent. But in the opposite sequence when (+)-$\alpa$-methoxy-$\alpa$-(trifluoromethyl)phenylacetyl chloride was used. No racemization was found during the reaction.

  • PDF

Carbonation Mitigation of the High Volume Admixture Concrete according to Application Method of Carbonation Resistance Material (탄산화 억제제 사용 따른 혼화재 다량 치환 콘크리트의 탄산화 억제)

  • Jo, Man-Ki;Choi, Young-Doo;Son, Ho-Jung;Woo, Dae-Hun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.271-273
    • /
    • 2012
  • This paper is to investigate the effect of waste cooking oil(WCO) on carbonation resistance of high volume fly ash and blast furnace slag concrete. WCO and paint were applied for carbonation resistance materials. As expected, the application of WCO to the concrete help it reduce carbonation depth remarkably, regardless of mixture types. This may be due to the fact that WCO makes the capillary pore block by activating saponification. It is found that the degree of carbonation reduce due to WCO is much higher than the case by Paint.

  • PDF

Feasibility Study on Design of Thrust Bearing for Micro Gas Turbine Generator (초소형 가스 터빈 제너레이터용 스러스트 베어링의 설계 및 타당성에 관한 연구)

  • 이용복;곽현덕;김창호;장건희
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.467-475
    • /
    • 2001
  • Feasibility study of gas-lubricated bearing in micro gas turbine was performed. Based on Reynolds equation, finite difference method with coupled boundary was developed to analyze bearing characteristics, such as load capacity, mass flow rates and stiffness. By the bearing force and mass flow rates analysis with the variation of supply pressure, bearing clearance and capillary radius, acceptable range of design parameters were suggested in terms of load capacity and stiffness of bearings. Additionally, coupled boundary effect on pressure distribution was investigated and it is stated that coupling could reduce an excitation force due to narrow pressure distribution.

Fabrication of a Resonator using suspended Multi-wall Carbon Nanotubes (다중벽 탄소나노튜브를 이용한 공진기 제작)

  • Lee J.H.;Seo H.W.;Song J.W.;Han C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.465-466
    • /
    • 2006
  • A single-wall carbon nanotube (SWCNT) has been studied as a material of Nano-Eletro-Mechanical-System (NEMS) device together with various nanowires. In order for oscillation of a multi-wall carbon nanotube (MWCNT) or a single-walled carbon nanotube (SWCNT) on plane surface, it needs suspension of a CNT across trench electrodes. So we propose fabrication method of a MWCNT resonator using dielectrophoresis and show successful results of suspeneded MWNT. Thin electrodes with large gaps could not suspend small diameter MWNT but thicker electrodes could. Thin MWNT could be suspended only when the electrode gap was reduced.

  • PDF

Feasibility Study on Design of Thrust Bearing for Micro Gas Turbine/Generator (초소형 가스 터빈/제너레이터용 스러스트 베어링의 설계 및 타당성에 관한 연구)

  • 곽현덕;이용복;김창호;장건희
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.273-281
    • /
    • 2001
  • Feasibility study of gas-lubricated bearing in micro gas turbine was performed. Based on Reynolds equation, finite difference method with coupled boundary was developed to analyze bearing characteristics, such as load-carrying capacity, mass flow rates and stiffness. By the bearing force and mass flow rates analysis with the variation of supply pressure, bearing clearance and capillary radius, acceptable range of design parameters were suggested in terms of load capacity and stiffness of bearings. Additionally, coupled boundary effect on pressure distribution was investigated and it is stated that coupling could reduce all excitation force due to narrow pressure distribution.

  • PDF

Numerical Analysis of Subsurface Flow in a Hillslope (자연 구릉지에서 지표하 흐름의 수치해석)

  • 최은호;남선우
    • Water for future
    • /
    • v.24 no.1
    • /
    • pp.109-117
    • /
    • 1991
  • The governing equation of flow in porous media is developed on the bases of the continuity equation of fluid for transient flow through a saturated-unsaturated zone, and substitution of Darcy's law. The numerical solutions are obtained by finite element method based on the Galerkin principles weighted residuals. The analysis are carried out by using the unsteady storm data observed and rainfall intensities which are obtained by using the rainfall excess model in considering of the initial losses. The functional relationships between the hydraulic conductivity, capillary pressure head and volumetric water content are applied to the flow of water through unsaturated soil varied with changes of water content.

  • PDF

Saturated - Unsaturated Transient Subsurface Flow Model on a Hillslope

  • Choi, Eun-Ho;Nahm, Sun-Woo
    • Korean Journal of Hydrosciences
    • /
    • v.2
    • /
    • pp.13-24
    • /
    • 1991
  • The governing partial differential equation of flow in porous media is developed on the bases of the continuity equation of fluid for transient flow through a saturated-unsaturated zone, and substitution of Dercy's law. The numerical solution is obtained by the Galerkin finite element method based on the principle of weighted residuals. The analysis is carried out by using the unsteady storm data observed and the functional relationships between the hydraulic conductivities, capillary pressure heads, and volumetric water contents under saturated-unsaturated conditions. As the results the hydraulic conductivities, rates of change of storage and initial moisture conditions are significantly influened on the responses of subsurface flow on a hillslope.

  • PDF

Immunohistochemical Analysis for Excessive Splenomegaly in Transgenic Mice Expressing Dimeric Erythropoietin

  • Park, Chae-Won;Yun, Sung-Jo;Min, Kwan-Sik
    • Reproductive and Developmental Biology
    • /
    • v.34 no.2
    • /
    • pp.111-115
    • /
    • 2010
  • Erythropoietin (EPO), a glycoprotein hormone produced from primarily cells of the peritubular capillary endothelium of the kidney, is responsible for the regulation of red blood cell production. We have been investigating the roles of glycosylation site added in the biosynthesis and function of recombinant protein. In this study, we analyzed by immunohistochemical methods adaptive mechanisms to excessive erythrocytosis in transgenic (tg) mice expressing dimeric human erythropoietin (dHuEPO) gene. Splenomegaly was observed over 11~21 times in the tg mice. The 2,672 candidate spleen-derived genes were identified through the microarray analysis method, and decreased genes were higher than increased genes in the spleen. The specific proteins in the increased and decreased genes were analyzed by immunohistochemical methods. Our results demonstrate that problems of abnormal splenomegaly would solve in tg mice overexpressing dHuEPO gene.

An Electrochemical Detector Using Prussian Blue Electrodeposited Indium Tin Oxide Electrode (Prussian blue가 전착된 indium tin oxide 전극을 이용한 전기화학적 검출기)

  • Yi, In-Je;Kim, Ju-Ho;Kang, Chi-Jung;Kim, Yong-Sang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.10
    • /
    • pp.449-452
    • /
    • 2005
  • We fabricated an electrochemical detector (ECD) to catalyze redox reaction efficiently by electrodepositing Prussian blue (PB) on the indium tin oxide (ITO) electrode. Capillary electrophoresis (CE) and amperometric method were used. We investigated the PB surface properties by topography from atomic force microscopy (AFM). Also PB film thickness calibration with respect to deposition time and voltage was used to get better PB surFace. The PB thin film of dense and smooth surface could catalyze redox reaction efficiently. Comparing with CE-ECD microchip using bare-lTO electrode, proposed CE-ECD microchip using PB deposited electrode has shown better sensitivity by determining the detected peak current from the electropherograms while the concentration of tested analyzes was maintained the same. It is verified that detection limit can be lowered for 0.01 mM of dopamine and catechol respectively.