• Title/Summary/Keyword: Capillary flow

Search Result 382, Processing Time 0.026 seconds

Characteristics of Shear-Thinning Fluid Viscosity under Traversal Vibration (진동장에서의 전단박화 유체 점도의 특성 연구)

  • Ku Yun-Hee;Lee Ji-Hyung;Shin Sehyun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.317-320
    • /
    • 2002
  • The effect of vibration on the viscosity of a shear-thinning fluid was investigated with a newly designed pressure-scanning capillary viscometer. The viscometer was designed to measure non-Newtonian viscosity continuously over a range of shear rates at a time. Low frequency vibration was applied perpendicularly to the direction of the flow. The effect of the transversal vibration was investigated for both Newtonian fluids and non-Newtonian fluids. The experimental results showed that the vibration had no effect on the viscosity of the Newtonian fluids. However, the vibration caused a significant reduction of the shear-thinning fluid viscosity. The viscosity reduction was strongly dependent on both vibration frequency and shear rate. In addition, the viscosity reduction was affected by the amplitude of vibration, and, the bigger amplitude applied, the more viscosity reduction occurred.

  • PDF

Sound Propagation through the Diesel Particulate Filter (DPF) (디젤 매연여과기 (DPF) 내에서의 음향전파)

  • Choi, Won-Yong;Ih, Jeong-Guan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.152-155
    • /
    • 2005
  • Diesel particulate filter (DPF) is comprised of a number of capillary tubes enclosed by porous ceramic wails, shaped like a plugged duct. Hot gas flows through the DPF along with the exhaust noise from Diesel engine. Based on previous works on the sound propagation through DPF, in this study, losses at entrance, exit, and ceramic walls are considered and the gradients in temperature and flow velocity are considered. Transfer matrix at entrance, monolith, and exit parts are obtained by employing the segmental approach in analyzing the sound propagation through DPF. The predicted transmission loss agrees very well with the empirical one, which is measured by the improved method with correction terms.

  • PDF

Fabrication and Characteristics Test of Micro Heat Pipe Array for IC Chip Cooling (IC 칩 냉각용 초소형 히트 파이프의 제작 및 성능 평가)

  • 박진성;최장현;조형철;조한상;양상식;유재석
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.351-363
    • /
    • 2001
  • This paper presents an experimental investigation on the heat trensfer characteristic of micro pipe (MHP) array with 38 triangular microgrooves. A heat pipe is an effective heat exchanger operating without external power. The heat pipe transfers heat by means of the latent heat of vaporization and two-phase fluid flow driven by the capillary force. The overall size of the MHP array can be put undermeath a microelectonic die and integrated into the electrronic package of a microelectronin device to dissipate the heat from the die. The MHP array is fabricated by micromachining with a silicon wafer and a glass substrate. The MHP was filled with water and sealed. The experimental results show the temperature decrease of 12.1$^{\circ}C$ at the evaporator section for the input power of 5.9 W and the improvement of 28% in the heat transfer rate.

  • PDF

?Experimental Study on the Effects of Zanthoxyli Fructus and Fagarae mandshuricae Fructus (천초(川椒) 및 산초(山椒)의 효능(?能)에 관(關)한 실험적(實驗的) 연구(硏究))

  • O, Han-Gyun;Won, Jong-Hun;Jeong, Gyu-Man
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.4 no.1
    • /
    • pp.1-17
    • /
    • 1990
  • ?In order to investigate effects of Zanthoxyli Fructus (Sample-A) and Fagarae mandshuricae Fructus (Sample-B), experimental study was performed through observation on isolated - ileum analgesic, hypothermal, anti-pyretic, anti-inflammatory, capillary permeability, blood flow rate, blood pressure and respiratory works. The results were as follows; 1. In spontaneous movement of mice isolated-ileum, both samples were noted to have strong inhibitory action after temporary contraction, and to show antagonism against acetylcholine chloride and barium chloride. 2. Both samples were showed to have antihistamin work on guinea pig isolated-ileum 3. In analgesic work by the acetic acid method, only Fagarae mandshuricae Fructus was proved to have significant analgesic effect in mice. 4. Both sample groups indicated anti-pyretic and anti-inflammatory effect. 5. Both samples were noted to have inhibitory effect against capillary permeability ?rise in mice. ?6. Both samples were noted to have dose-dependent falling effect on blood pressure in rabbits.

  • PDF

Viscosities of $LaCl_3-NaCl$ Binary Melts ($LaCl_3-NaCl$ 2성분계 용융염의 점도)

  • Kim, Ki-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.6
    • /
    • pp.282-287
    • /
    • 2006
  • Viscosities of $LaCl_3-NaCl$ binary melts were measured by the capillary method over the range of their liquidus temperatures to about 1200K. The cell constant were determined by using pure water. The results obtained are summerized as follows: Viscosities were decreased with the content of NaCl for all over the composition range of binary melts. Composition - viscosity relation for the binary melts show a non-linear from the additivity line and the deviations shows a maximum at about 60 mol% NaCl. This suggests the existence of the complex ion of $LaCl_4^-$ in the melt. Activation energy for viscous flow of the binary melts decrease monotonously with the increasing content of NaCl.

Fundamental study on performance characteristics of a micro heat pipe with triangular cross section (삼각단면 극소히트파이프의 작동특성에 관한 기초 연구)

  • 문석환;김종오;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.176-184
    • /
    • 1999
  • Numerical and experimental studies were performed to examine the characteristics of heat and mass transfer processes for a Micro Heat Pipe(MHP) with a triangular cross-section. Solutions on mass flow rate, pressure variation, and radius of meniscus were obtained using the mathematical model developed by Faghri and Khrustalev. To obtain an increase in capillary limitation, a triangular tube with curved walls was designed and fabricated. The measurement by microscope showed that the radius at corners of the tube was ranging between 0.03-0.05mm. Performance test for MHPs using the triangular tube with curved walls proved a substantial increasement in heat transport limitation, with 4.5W and 2.0W in case of using water and ethanol as a working fluid, respectively. In the previous study by Faghri a limitation of 0.5W was reported for a water MHP with a regular triangular tube.

  • PDF

Cyclic Capilary Electrophoresis Separator on Silicon Substrate with Synchronized Switching (실리콘 기판 위에서 구현된 회전형 전기영동분리기)

  • Jeong, Yong-Won;Kim, Bong-Hwan;Lee, Jun-Yeop;Cho, Gyeong-Yeon;Chang, Jun-Geun;Chun, Guk-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.640-648
    • /
    • 2000
  • We have developed a synchronously switched cyclic capillary electrophoresis (CE) separator that is fabricated on a silicon substrate and glass containing reservoirs, Au electrode, and isolated channels. The advantage of a cyclic separator is the high resolution and ability to separate each sample to the designated reservoir from mixed samples. This approach makes it possible to reduce the supplied voltage and the total size. Another goal of this work is to introduce the methodolgy of electroosmosis flow(EOF) to silicon substrate and to separate DNA samples using a modified double-T injector.

  • PDF

Investigation on the pressure drop characteristics of oscillating flow through regenerators under pulsating pressure conditions (맥동압력조건에서 재생기를 통한 왕복유동의 압력강하 특성에 대한 연구)

  • 최성열;남관우;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.51-57
    • /
    • 2003
  • This paper proposes a new oscillating flow model of the pressure drop through the regenerator under pulsating pressure. In this oscillating flow model. pressure drop is expressed by the amplitude and the phase angle with respect to the inlet mass flow rate. In order to generalize the oscillating flow model. non-dimensional parameters, which are Reynolds number, Valensi number, gas domain length ratio, oscillating flow friction factor and phase angle of pressure drop, are derived from the capillary tube model of the regenerator. Correlations for the oscillating flow friction factor and the phase angle are obtained from the experiments for the twill-square screen regenerators under various operating frequencies and inlet mass flow rates. The oscillating friction factor is a function of the Reynolds number alone and the phase angle of pressure drop is a function of the Valensi number and the gas domain length ratio. Experiment is also performed to examine the effect of the weave style of screen. Experimental data demonstrate the superiority of the oscillating flow model over the previous steady flow model.

Numerical Analysis of the Flow Characteristics in the Nano Fountain-Pen Using Membrane Pumping (박막펌핑을 이용한 Nano Fountain-Pen의 유동 특성에 관한 수치적 연구)

  • Lee, J.H.;Lee, Y.K.;Lee, S.H.;Kim, Hun-Mo;Kim, Youn-J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.2 s.35
    • /
    • pp.19-24
    • /
    • 2006
  • Nano fountain-pen is a novel device to make the constant patterning in micro process using new designed probe. Fountain-pen nanolithography (FPN) is applied for constant supply of liquid in conjunction of patterns and surface variation in the micro process. In this study, nuo fountain-pen is composed with reservoir, micro channels, tip and scondary chamber. Instead of traditional method only using capillary force, liquid can be definitely and exactly injected with membrane pumping by the repulse force of tip. It is dfficult to perform experiments in the micro range so that we carried out a numerical analysis for internal flow, using a commercial code, FlUENT, The velocity, pressure and flow rate are obtained under laminar, unsteady, three-dimensional incompressible flow with no-slip condition, and results are graphically described.

Optimization of Heat Pump Systems (열펌프의 성능 최적화에 관한 연구)

  • Choi, Jong-Min;Yun, Rin;Kim, Yong-Chan
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.22-30
    • /
    • 2007
  • An expansion device plays an important role in optimizing the heat pumps by controlling refrigerant flow and balancing the system pressures. Conventional expansion devices are being gradually replaced with electronic expansion valves due to increasing focus on comfort, energy conservation, and application of a variable speed compressor. In addition, the amount of refrigerant charge in a heat pump is another primary parameter influencing system performance. In this study, the flow characteristics of the expansion devices are analyzed, and the effects of refrigerant charge amount on the performance of the heat pump and the variation of compressor speed are investigated at various operating conditions. Mass flow rate through capillary tube, short tube orifice, and EEV was strongly dependent on the upstream pressure and subcooling. The heat pump system is very sensitive with a variation of refrigerant charge amount. The performance of it can be optimized by adjusting the flow rate through expansion device to maintain a constant superheat at all test conditions.

  • PDF