• Title/Summary/Keyword: Capillary flow

Search Result 382, Processing Time 0.028 seconds

Development of simulation program for TXV and capillary tube performance analysis (감온 팽창밸브 및 모세관 성능 시뮬레이션 프로그램 개발)

  • 박봉수;한창섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.170-180
    • /
    • 2000
  • The equation which is related to TXV performance was investigated. On the basis of this equation, the TXV simulation program was developed. Results of the developed TXV simulation program were proven by the experiment on the influence of pressure difference between TXV entrance and exit and equalizing pressure. Simulation results show very good agreement with experimental results, the RMS error between them was 1.83%. The capillary tube simulation program was made by the basic equation of fluid dynamics. Results of this program were proven by data which were experimented previously. The RMS error between simulation results and experimental results was 4.13% .

  • PDF

Nonaqueous Capillary Electrophoresis of Chlorinated Phenols

  • 김보정;전만석;신상무;정두수
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.12
    • /
    • pp.1483-1486
    • /
    • 1999
  • The contents of pentachlorophenol (PCP) and 2,3,5,6-tetrachlorophenol (TeCP) in textile products are regulated for safety. Since an organic solvent such as 2-methoxyethanol is needed to extract chlorinated phenols from textile samples, nonaqueous capillary electrophoresis has been applied to achieve the separation of PCP and isomers of TeCP. The run buffer was 100 mM Tris/acetate in methanol whose pH was adjusted to 8.0. All of the analytes were negatively charged at pH 8.0 and their electrophoretic velocities were higher than the electroosmotic flow of the methanol buffer. A reverse voltage of -20 kV was applied along a 27-cm fused silica capillary with ID of 50 μm, and PCP and 3 TeCP isomers were separated based on the difference in $pK_a$ values in less than 4 min. The limits of detection (S/N = 3) were about 0.02 μM. By varying pH of the methanol run buffer, $pK_a$ values of the 4 chlorinated phenols were also estimated.

Nanoparticle Contrast in Magneto-Motive Optical Doppler Tomography

  • Kim, Jee-Hyun;Oh, Jung-Hwan
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.99-104
    • /
    • 2006
  • We introduce a novel contrast mechanism for imaging superparamagnetic iron oxide (SPIO) nanoparticles (average diameter ${\sim}100nm$) using magneto-motive optical Doppler tomography (MM-ODT), which combines an externally applied temporally oscillating high-strength magnetic field with ODT to detect the nanoparticles flowing through a glass capillary tube. A solenoid cone-shaped ferrite core extensively increased the magnetic field strength ($B_{max}=1\;T,\;{\Delta}|B|^2=220T^2/m$) at the tip of the core and also focused the magnetic force on targeted samples. Nanoparticle contrast was demonstrated in a capillary tube filled with the SPIO solution by imaging the Doppler frequency shift which was observed independent of the flow rate and direction. Results suggest that MM-ODT may be a promising technique to enhance SPIO nanoparticle contrast for imaging fluid flow.

THE PROCESS OF THE DEVELOPMENT OF HYPOXIA IN AN ABNORMAL BLOOD FLOW

  • Kwak, Min-Kyu;Shin, Byeong-Chun;Go, Jae-Gwi
    • Honam Mathematical Journal
    • /
    • v.30 no.1
    • /
    • pp.75-89
    • /
    • 2008
  • Interrupted blood flow diminishes the concentration of oxygen in tissues. Hypoxia first appears in the region distal to the capillaries and grows throughout the entire t issue. However, the time-wise evolution of hypoxic area is diverse when some of capillaries are blocked in a multi-capillary domain with different oxygen squirt. The process of the development of hypoxia through time course is analyzed mathematically in the domain. Each source in steady state is controlled by a time sensitive function to simulate the occlusion.

Flow Behavior at the Embossing Stage of Nanoimprint Lithography

  • Jeong, Jun-Ho;Park, Youn-Suk;Shin, Young-Jae;Lee, Jae-Jong;Park, Kyoung-Taik
    • Fibers and Polymers
    • /
    • v.3 no.3
    • /
    • pp.113-119
    • /
    • 2002
  • Nanoimprint lithography (NIL) is a nanofabrication method known to be a low cost method of fabricating nanoscale patterns as small as 6 m. This study is focused on understanding physical phenomena in the embossing of nano/micro scale structures with 100 nm minimum feature size. We present the effects of capillary force and width of stamp groove on flow behavior at the embossing stage through numerical experimentation. We also compare our numerical results with previous experimental results and discuss our results.

A Study on Reduction of Refirigerant Noise in Household Refrigerator (냉장고 냉매 소음의 저감에 관한 연구)

  • Choi, Seong-Won;Hwang, Won-Gul;Sul, Seoung-Yun;Im, Hyung-Eun;Kim, Sang-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1062-1066
    • /
    • 2004
  • In this study, refrigerant noise at connection of capillary tube and evaporator is investigated. Mechanism of refrigerant noise generation is examined in side-by-side type home refrigerator with two evaporators. It is found that the refrigerant noise is generated during refrigeration room fan-off (R-fan of) for that type refrigerator. The reason is that mass flow rate gets down during R-fan of and flow pattern is changed at outlet of capillary tube. We suggest designs for reduction of refrigerant noise with horizontal double expansion device, muffler, and accumulator. To evaluate those improved designs, sound quality index is used.

  • PDF

Effects of Mesh Size in a Flat Evaporator and Condenser Cooling Capacity on the Thermal Performance of a Capillary Pumped Loop

  • Boo, Joon-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.121-129
    • /
    • 2000
  • The thermal performance of a flat evaporator for capillary pumped loop (CPL) applications was investigated. Two to four layers of coarse wire screen wicks were placed onto the heated surface to provide irregular passages for vapor flow. The evaporator and condenser were separated by a distance of 1.2 m and connected by individual liquid and vapor lines. The wall material was copper and the working fluid was ethanol. The experimental facility utilized a combination of capillary and gravitational forces for liquid return, and distribution over the evaporator surface. The tubing used for vapor and liquid lines was 9.35 mm or less in diameter and heat was removed from the condenser by convection of air. A heat flux of up to $4.9{\times}10^4$ $W/m^2$ was applied to a flat evaporator having dimensions of 100 mm by 200 mm, 20 mm thick. The thermal resistance of the system as well as the temperature characteristics of the system was investigated as the evaporator heat flux and the condenser cooling capacity varied. The performance of the evaporator and effect of condenser cooling capacity were analyzed and discussed.

  • PDF

Rheological behavior of dilute bubble suspensions in polyol

  • Lim, Yun-Mee;Dongjin Seo;Youn, Jae-Ryoun
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.1
    • /
    • pp.47-54
    • /
    • 2004
  • Low Reynolds number, dilute, and surfactant-free bubble suspensions are prepared by mechanical mixing after introducing carbon dioxide bubbles into a Newtonian liquid, polyol. The apparent shear viscosity is measured with a wide-gap parallel plate rheometer by imposing a simple shear flow of capillary numbers(Ca) of the order of $10^{-2}$ ~ $10^{-1}$ and for various gas volume fractions ($\phi$). Effects of capillary numbers and gas volume fractions on the viscosity of polyol foam are investigated. At high capillary number, viscosity of the suspension increases as the gas volume fraction increases, while at low capillary number, the viscosity decreases as the gas volume fraction increases. An empirical constitutive equation that is similar to the Frankel and Acrivos equation is proposed by fitting experimental data. A numerical simulation for deformation of a single bubble suspended in a Newtonian fluid is conducted by using a newly developed two-dimensional numerical code using a finite volume method (FVM). Although the bubble is treated by a circular cylinder in the two dimensional analysis, numerical results are in good agreement with experimental results.

Determinaton of Chloride Ion Captured into Strong NaOH Solution from Chimney by Capillary Electrophoresis (모세관 전지영동법에 의한 굴뚝에서 포집된 NaOH 용액속의 염소이온의 측정)

  • 임인덕;성용익;김양선;임흥빈
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.3
    • /
    • pp.327-333
    • /
    • 1999
  • Determination of chloride ion in concentrated NaOH solution by capillary electrophoresis has been studied. The analysis was performed by indirect UV absorption detection using chromate buffer at 254nm. The matrix effect of the sample has been observed so that the sensitivity in strong NaOH solutaion has decreased up to 10% of that in distilled water. The pH effect of the sample on the sensitivity of CE peaks has been investigated. The method for increasing the sensitivity have been investigated and the optimum pH and concentration of the buffer were 7.5 and 10mM, respectively. A cationic surfactant cetyltrimethylammonium bromide(CTAB), was added to a buffer solution in order to reverse the electroosmotic flow(EOF) in the capillary. This results in a short analysis time and better peak shapes. Using this optimum condition, the determination of chloride ion in real environmental sample has been performed, which is captured in strong NaOH absorbent prepared for absorbing gas from chimney. The standard addition method has been applied for the quantitative analysis, and it was obtained the good reproducibility.

  • PDF

Can Daily-use Lipstick Make Lips More Fresh and Healthy\ulcorner - A New Lipstick Containing $\alpha$-Glucosyl-hesperidin Can Remove the Dull-color from Lips

  • Iwai, I.;Yamashita, T.;Ochiai, N.;Masuda, Y.;Hosokawa, K.;Kohno, Y.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.162-177
    • /
    • 2003
  • It has been known that the color of skin reflects the blood flow within. In lips, the capillaries close to the skin surface are numerous; hence lips are redder than the rest of face. However, dermatological research on lips is not as advanced as research on facial or body skin, and little was known about the relationship between relatively dull-colored lips and skin blood flow. The physiological differences between colorful and dull-colored lips were studied by a two-dimensional laser Doppler blood flow analyzer, a spectrometer for the measurement of the degree of oxygen saturation, and a confocal microscope for observing inside lips non-invasively. Dull-colored lips and the corner of lips (dull-colored compared to the center) showed relatively poor blood flow and lower oxygenated hemoglobin. It was found that colorful lips (generally the young) had a blood flow that tended to run straight in parallel with the skin surface. This unique blood-capillary structure can express clear red blood. Those with dull-colored lips had lost this unique structure. Their blood ran perpendicularly from the deep of the skin and down back again into the deep part as like the blood circulation patterns of facial skin. Therefore, the lips of the latter group had fewer blood capillaries near skin surface in the lips than that of the colorful-lips group. A lipstick containing a-glucosyl-hesperidin, which is derived from certain citrus fruits and can enhance blood circulation, was applied for evaluating its effects. Blood flow was increased 30 min after the application. After two weeks of daily application, the lips' condition became noticeably less dull. These findings suggest that the decrease of blood flow in dull-colored lips is caused by the loss of the unique capillary structure and the use of the lipstick to increase blood flow can give a vivid color to lips.

  • PDF