• Title/Summary/Keyword: Capillary Gas Chromatography

Search Result 126, Processing Time 0.019 seconds

Simultaneous Gas Chromatographic Analysis of Ethanol and Acetic Acid in Vinegar (식초의 에탄올 및 초산 함량의 동시분석)

  • Yoon, Hee-Nam
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.1247-1251
    • /
    • 1998
  • A method is developed for simultaneously determining ethanol and acetic acid in vinegars by quantitative packed-column gas chromatography. Vinegars were filtrated and directly chromatographed on a $2\;m{\times}2\;mm$ stainless steel column packed with Tenax-GC, 80/100. Ethanol, isopropy alcohol as an internal standard, and acetic acid were completely separated within 20 min of running time without any interfering peaks. The accuracy of packed column gas solid chromatography (PCGSC) was discussed compared to the analytical data by titration, high performance liquid chromatography and capillary column gas liquid chromatography (CCGLC).

  • PDF

Analysis of lipopolysaccharides of Pasteurella multocida and several Gram-negative bacteria by gas chromatography on a capillary column (Gas chromatography의 capillary column을 이용한 Pasteurella multocida 및 기타 그람음성 세균의 lipopolysaccharide 분석)

  • Ryu, Hyo-ik;Kim, Chul-joong
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.1
    • /
    • pp.72-80
    • /
    • 2000
  • Lipopolysaccharides (LPS) of Pasteurella multocida (P multocida) and several Gram-negative bacterial pathogens were analyzed by methanolysis, trifluoroacetylation and gas chromatography (GC) on a fused-silica capillary column. The GC analysis indicated that LPS prepared from a strain of P multocida by phenol-water (PW) or trichloroacetic acid (TCA) extraction were quite different in chemical composition. However, LPS prepared from Salmonella enteritidis by the two extraction methods were very similar. PW-LPS extracts from different Pasteurella strains of a serotype had essentially identical GC patterns. Endotoxic LPS extracted from 16 different serotypes of P multocida by PW or by phenol-chloroform-petroleum ether procedures yielded chromatograms indicating similar composition of the fatty acid moieties but minor differences in carbohydrate content. When the chemical composition of endotoxic LPS extracted from several Gram-negative bacteria (P multocida, Pasteurella hacmolytica, Haemophilus somnus, Actinobacillus ligniersii, Brucella abortus, Treponema hyodysenteriae, Escherichia coli, Bacteriodes fragilis, Salmonella abortus equi and Salmonella enteritidis) were examined, each bacteria showed a unique GC pattern. The carbohydrate constituents in LPS of various Gram-negative bacteria were quite variable not only in the O-specific polysaccharides but also in the core polysaccharides. The LPS of closely related bacteria shared more fatty acid constituents with each other than with unrelated bacteria.

  • PDF

Multidimensional Gas Chromatography-A Powerful Tool for the Analysis of Multicomponent Mixtures

  • Kim, Kyoung-Su
    • Preventive Nutrition and Food Science
    • /
    • v.1 no.1
    • /
    • pp.127-133
    • /
    • 1996
  • The development of high resolution capillary columns and a large variety of different detectors led to a strong position of gas chromatography in instrumental analysis. Every effort has been made to solve sophisticated separation problems by column switching. Nowadays, several systems are commercially available for this purpose. The principle and the capabilities of multidimensional gas chromatography(MDGC) are illustrated by different applications in the field of modern flavor and essential oil research.

  • PDF

GC Capillary Column Installation (가스 크로마토그래피 캐필러리 컬럼 설치 가이드)

  • Matt James;Kirsty Ford
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.2.1-2.6
    • /
    • 2024
  • This article provides detailed instructions for the correct installation, maintenance, and troubleshooting of capillary gas chromatography (GC) columns. It emphasizes the importance of proper installation to ensure optimal performance and longevity of the column. The document covers various aspects such as column trimming, installation, conditioning, testing, storage, and ferrule selection. The installation process involves ensuring that the heated zones of the GC are cool before placing the column cage in the column oven. It is essential to avoid sharp bends or stress on the capillary column during installation and to connect the front end of the column into the GC inlet at the recommended insertion distance. The document also provides guidance on trimming the column, including the use of a ceramic wafer or capillary column cutter to achieve a clean, burr-free cut. For previously used columns, it recommends removing any capillary caps, positioning the nut and ferrule, and trimming 1-2 cm from the column. After installation, the column should be purged with carrier gas to remove any oxygen and avoid oxidizing the column. Conditioning the column involves ramping to the upper isothermal temperature limit and maintaining this temperature for a specified duration. It is crucial to maintain carrier gas flow during conditioning and not exceed the upper temperature limit of the column to avoid phase damage. The document also discusses testing column performance using a suitable method and performing a test injection to assess performance. It provides recommendations for column storage, including flame-sealing the capillary ends or using retention gaps for long-term storage. Additionally, it emphasizes the importance of routine maintenance and replacement of GC consumables to extend the column's lifetime. Ferrule selection is another important aspect covered in the article, with a variety of ferrule materials available for different applications. The characteristics of common ferrule options are presented in a table, including temperature limits, reusability, and suitability for specific detector types.

  • PDF

Study on the Development of Analytical Method (Multi-Pesticide Residue Method) for Organophosphate Pesticides (유기인제 농약 분석 방법 (Multi-Pesticide Residue Method) 개발에 관한 연구)

  • 이봉헌;김우성
    • Journal of Environmental Science International
    • /
    • v.6 no.2
    • /
    • pp.183-187
    • /
    • 1997
  • Organophosphate pesticides were extracted with 70% acetone and then transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil. The florial extract was analyzed by gas chromatography with nitrogen-phosphorus detector(GC/NPD). Recoveries of the 18 organophosphate pesticides were ranged from 88.7% to 100. 0% for the narrow-bore capillary GC(Ultra-21. The minimum detectable level of this analytical method was 0.019 - 0.035 mg/kg. Sample throughput(extraction, open-column chro- matography, and GC analysts) was decreased considerably (8h per sample).

  • PDF

Identification of 4-Demethylsterols from Suspension Cultured Cells of Marchantia polymorpha L. (Marchantia polymopha(우산이끼) 현택배양 세포내으 4-methylster이들의 동정)

  • Seong-Ki Kim
    • Journal of Plant Biology
    • /
    • v.38 no.3
    • /
    • pp.219-225
    • /
    • 1995
  • Five kinds of 4-demethylsterol were isolated from suspension cultured cells of a liverworth, Marchantia polymorpha. Four 4-demethylsterols among them were analyzed by a capillary gas chromatography-massspectrometry and 500 MHz 1H-NMR, and characterized to be avenasterol, 24-methylene-cholesterol, stigmasterol, and campesterol. And the fifth 4-demethylsterol was characterized to be sitosterol by a capillary gas chromatography-mass spectrometry. The concentration of the 4-demethylsterols in the cell decreased in order of avenasterol>stigmasterol>24-methylene-cholesterol>campesterol>sitosterol. When carbon skeleton and the oxidation state was compared with those of brassinosteroids, these 4-demethylsterols may be potent biosynthetic procusors of brassinosteroids in the cells.

  • PDF

Gamma-linolenic Acid Content of Evening Primrose(Oenothera odorata Jacq.) in Korea (국내수집 달맞이꽃 종실의 감마-리놀렌산 함량(Ⅵ보))

  • 임웅규
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.35 no.2
    • /
    • pp.176-178
    • /
    • 1990
  • The essential fatty acid composition of evening primrose seed at 3 natural habitats in Korea was investigated by means of capillary column gas-chromatography. The content of essential fatty acid components was palmitic acid 6.19-6.73%. stearic acid 1.84-1. 99%, oleic acid 6.73-9.10%. linoleic acid 74.41-75.53%. Particularly. gamma-linolenic acid (GLA) which is a precursor of prostaglandin was 9.14% in Cheong-ju. 9.32% in Che-cheon and 8.31% in An-dong. Based on the GLA content evening primroses in Korean natural habitats seem to be very promising and useful for GLA production.

  • PDF

STUDIES ON THE SEPARATION & DETERMINATION OF CIS-TRANS FATTY ACIDS IN CIGARETTE SMOKE CONDENSATE BY GLASS CAPILLARY GAS CHROMATOGRAPHY (유리모세관칼럼에 의한 담배연기응축물중의 cis-trans형 지방산의 분리정량에 관한 연구)

  • Rhee, M.S.;Lee, U.C.;Kim, C.H.
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.7 no.1
    • /
    • pp.67-74
    • /
    • 1985
  • Cis-trans forms of fatty acids in cigarette smoke condensate were separated and characterized using SP 2340 glass capillary gas chromatography. The transforms of fatty acids, palmitoeladic , 1-vaccenic, eladic and linoeladic acid were identified. These components were not present only 3% of the total fatty acid fraction, but they showed a very low transfer rate.

  • PDF

The Screening and Pattern Comparison of Organic Acids in 3 Kinds of Medicinal Herbal Extracts (3가지 약용 허브 추출물에 함유된 유기산 검색 및 조성 비교)

  • Chung, Ha-Yull;Jung, Do-Hyun;Park, Young-Joon
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.997-1001
    • /
    • 2000
  • The organic acids in 3 kinds of medicinal herbal extracts were screened and compared each other according to their organic acid contents by an efficient gas chromatographic method. It involves solid-phase extraction of organic acids using Chromosorb P with subsequent conversion to stable tert-butyldimethysilyl derivatives for the direct analysis by capillary column gas chromatography and gas chromatography-mass spectrometry. Total of 24 organic acids were reproducibly identified from 3 kinds of herbal extracts. When the GC profiles were simplified to their retention index spectra, characteristic patterns were obtained for each herb sample. As expected, three kinds of herbal extracts showed three distinct patterns.

  • PDF