• Title/Summary/Keyword: Capacity of Anchorage

Search Result 142, Processing Time 0.024 seconds

An Assessment Study of Seismic Resistance of Two-story Wood-frame Housing by Shaking Table Tests

  • Ni, Chun;Kim, Sang-Yeon;Chen, Haijiang;Lu, Xilin
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.79-82
    • /
    • 2012
  • While there exists a relatively large body of technical information for the engineered design of wood-frame buildings to resist seismic ground motions, the quantitative assessment of seismic resistance of conventional houses built by prescriptive requirements is less well understood. Forintek Canada Corp., in collaboration with other research and industry partners, has embarked on a research project to address this topic. This paper will report on the seismic shake table tests of a full-scale wood-frame building. The two-story specimen, $6m{\times}6m$ in plan, was built on the seismic shake table at Tongji University in Shanghai, China, according to Part 9 of the 1995 National Building Code of Canada and shaken uni-directionally in each of the two principal directions. Three different seismic table motions were applied at increasing peak ground motion amplitudes up to 0.40 and 0.50 g. The specimen was repaired after the above sets of seismic table motions, and successive runs were conducted for increased door openings. Measurements included specimen accelerations, displacements and anchorage forces. Static stiffness of the specimen was measured at low force levels, and natural frequencies were measured after each seismic loading stage by applying low-level random excitation. The results presented consist of the capacity spectra of the shake table tests, changes in specimen stiffness and natural frequencies with increasing seismic loading. These results and those from other recent shake table tests elsewhere will be compared with simplified engineering calculations based on codified values of strength, and on that basis preliminary conclusions will be drawn on the adequacy of the current code provisions and design guides in Canada and the USA for conventional wood-frame construction.

Wireless structural health monitoring of bridges: present and future

  • Hoult, Neil A.;Fidler, Paul R.A.;Hill, Peter G.;Middleton, Campbell R.
    • Smart Structures and Systems
    • /
    • v.6 no.3
    • /
    • pp.277-290
    • /
    • 2010
  • Internationally the load carrying capacity of bridges is decreasing due to material deterioration while at the same time increasing live loads mean that they are often exposed to stresses for which they were not designed. However there are limited resources available to ensure that these bridges are fit for purpose, meaning that new approaches to bridge maintenance are required that optimize both their service lives as well as maintenance costs. Wireless sensor networks (WSNs) provide a tool that could support such an optimized maintenance program. In many situations WSNs have advantages over conventional wired monitoring systems in terms of installation time and cost. In order to evaluate the potential of these systems two WSNs were installed starting in July 2007 on the Humber Bridge and on a nearby approach bridge. As part of a corrosion prevention strategy, a relative humidity and temperature monitoring system was installed in the north anchorage chambers of the main suspension bridge where the main cables of the bridge are anchored into the foundation. This system allows the Bridgemaster to check whether the maximum relative humidity threshold, above which corrosion of the steel wires might occur, is not crossed. A second WSN which monitors aspects of deterioration on a reinforced concrete bridge located on the approach to the main suspension bridge was also installed. Though both systems have provided useful data to the owners, there are still challenges that must be overcome in terms of monitoring corrosion of steel, measuring live loading and data management before WSNs can become an effective tool for bridge managers.

Shear Behavior of Large Prestressed Concrete Beams Cast with High Strength Concrete and the Effect of Draped Tendon on their Shear Behavior (고강도 대형 프리스트레스트 콘크리트 보의 전단거동과 경사진 프리스트레싱 긴장재의 영향)

  • Kim Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.963-974
    • /
    • 2005
  • This paper presented four shear test results from experimental tests of two large prestressed concrete beams cast with high strength concrete. In particular, this experiment investigated the effects of draped strands on shear behavior of these full-scaled beams. This study indicated that the use of draped strands increased the ultimate shear capacity as well as the web-shear cracking load. The test results also showed that draped strands reduced strand slip at ends of beams, which represented that these strands were effective to relieve the anchorage stresses. The test results were compared to predictions by two major codes; ACI 318-02 Building Code and AASHTO LRFD(2002). The shear design provisions in these codes provided conservative results on the shear strengths of all test specimens with reasonable margins of safety, and these provisions were particularly more conservative for test specimens having draped strands.

Improvement in Fatigue Durability of RC Beams Strengthened with Carbon Fiber Sheets (탄소섬유시트로 보강된 RC 보의 피로내구성 향상에 관한 연구)

  • Park, Jeong-Yong;Kim, Seong-Do;Jo, Baik-Soon;Kim, In-Tae;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.205-212
    • /
    • 2006
  • In recent investigations, reinforced concrete beams strengthened with Carbon Fiber Sheets (CFS) subjected to fatigue loading were reported to be failed at the ends of CFS by its debonding. U-shaped CFS were attached to both ends of the CFS when fatigue tests on strengthened beams were conducted to delay and/or prevent fatigue failures of adhesive interface. The experimental parameters of this study were the usage of anchorage at the ends of CFS, the number of CFS layers, and the applied load levels of 60%~90% of the static ultimate load obtained from the static tests. The failure modes and the load cycle-deflection relations were observed and discussed from the experimental results. Those results also showed that the U-shaped anchoring system changes the fatigue failure modes and influences greatly on the fatigue capacity of the strengthened beams.

Composition Method and Character for Beam String Structure in Structural Planning (구조계획에 있어 들림형 보구조의 특성과 구성방식)

  • Lee, Ju-Na;Park, Sun-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.3 s.21
    • /
    • pp.111-121
    • /
    • 2006
  • Beam String Structure is a structure system that is composed with beam, strut and string, and the structural capacity of this structure system is enhanced by introducing prestress force in string and controling the stress and deformation of beam. Researching on the established studies and examples, character and composition methods of Beam String Structure was investigated. At the result, It was examined that the design elements of the system are shape and rise of beam, sag of string, plan arrangement and the composition and number of strut, in addition, detailed composition methods of the design elements were represented. Also, it was showed that the method to form the individual mechanism against additional load can be employed in order to reduce stress of Beam String Structure under the heavy additional load.

  • PDF

Performance assessment of multi-hazard resistance of Smart Outrigger Damper System (스마트 아웃리거 댐퍼시스템의 멀티해저드 저항성능평가)

  • Kim, Hyun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.139-145
    • /
    • 2018
  • An outrigger system is used widely to increase the lateral stiffness of high-rise buildings, resulting in reduced dynamic responses to seismic or wind loads. Because the dynamic characteristics of earthquake or wind loads are quite different, a smart vibration control system associated with an outrigger system can be used effectively for both seismic and wind excitation. In this study, an adaptive smart structural control system based on an outrigger damper system was investigated for the response reduction of multi-hazards, including seismic and wind loads. A MR damper was employed to develop the smart outrigger damper system. Three cities in the U.S., L.A., Charleston, and Anchorage, were used to generate multi-hazard earthquake and wind loads. Parametric studies on the MR damper capacity were performed to investigate the optimal design of the smart outrigger damper system. A smart control algorithm was developed using a fuzzy controller optimized by a genetic algorithm. The analytical results showed that an adaptive smart structural control system based on an outrigger damper system can provide good control performance for multi-hazards of earthquake and wind loads.

Comparative Study on Seismic Design of Soil-Reinforced Segmental Retaining Walls (블록식 보강토 옹벽의 내진설계에 관한 비교연구)

  • 유충식
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.51-61
    • /
    • 2000
  • This paper reviews fundamentals of a pseudo-static seismic design/analysis method for soil-reinforced segmental retaining walls. A comparative study on NCMA and FHWA seismic design guidelines, which are one of the most well known design guidelines for mechanically stabilized earth walls, was also performed. The results demonstrate that there exist significant discrepancies in the results of external stability analysis despite the same calculation model used in the two guidelines, due primarily to different seismic coefficient selection criteria. It is also demonstrated that the internal stability calculation model for NCMA guideline tends to yield larger seismic reinforcement force in the shallower reinforcement layers, resulting in an increased number of reinforcement layers at the top of reinforced wall and increased reinforcement lengths to ensure adequate anchorage capacity. The internal stability calculation model adopted by FHWA guideline, however, leads to redistribution of dynamic force to the lower reinforcement layers and thus results n an opposite trend of NCMA guideline. Findings from this study clearly demonstrate a need for more in-depth studies to develop a generally acceptable design/analysis method.

  • PDF

Development and Performance Test for Unbonded Post-Tensioned Anchor (비부착 강연선에 대한 포스트텐션 정착구 개발 및 성능 시험)

  • Cho, Ah Sir;Jo, Yeong Wook;Jeon, Byong Kap;Kang, Thomas H.K.
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.11-20
    • /
    • 2015
  • An unbonded post-tensioned anchor using a 15.2 mm diameter 7-wire strand was developed based on finite element analysis and experimental testing. In order to evaluate its performance, static load tests and load transfer tests were conducted following KCI-PS101. The static load tests and additional strand tensile tests confirmed that the developed anchor had a capacity more than nominal tensile strength of a 7-wire strand without any damage or deterioration. According to the result of load transfer tests for many different reinforcing details, specimens with no additional reinforcing bars sustained at least 1.64 times the nominal tensile strength of the strand.

A study on Development of Methods to Rehabilitate the Damaged Prestressed Concrete beam Using Glass Fiber (유리섬유를 이용한 손상된 프리스트레스트 콘크리트 보의 보강공법 개발연구)

  • Kang, Won-Ho;Han, Man-Yop;Lee, Taek-Sung;Rhu, Young-Min
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.167-175
    • /
    • 1999
  • Many composite girder bridges have been constructed for about thirty five years. Nowadays they are aged or deteriorated because of the increase in traffic and vehicle loads. In this study, the effect of strengthening with glass fiber sheet is investigated to estimate the possibility for applying to damaged prestressed concrete bridges. One normal and eight cracked specimens which had been preloaded were tested. The cracked specimens were strengthened with either external prestressing or bonding glass fiber sheet, or using both methods. The results showed that the maximum loads are almost same for both methods. So it seems that the strengthening with glass fiber sheet can be used for strengthening damaged prestressed concrete girders. It is important that proper devices should be selected to prevent glass fiber sheet from premature bonding failure below its maximum load, which is similar to end anchorage problem in external prestressing method. It is proved that the devices proposed in this paper have sufficient anchoring capability to increase load carrying capacity.

An effect of immediate orthodontic force on palatal endosseous appliance$(C-Palatal\;Plate^{TM})$ in beagle Dog (성견 구개부 골내고정원 장치에 가해진 즉시 교정력이 주위조직에 미치는 영향)

  • Kim, Su-Jung;Lee, Young-Jun;Chug, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.91-102
    • /
    • 2003
  • This study was performed to investigate the effect of immediate orthodontic force on soft md hard tissues surrounding C-Palatal $Plate^{TM}$ in beagle Dog. Immediately after this appliance was implanted on the midpalate of 4 adult beagle Dogs, 400gm continuous orthodontic force was applied. Experimental animals were euthanized at 8weeks, 18weeks, and 22weeks (including post-removal healing time of 4weeks), and a control animal was euthanized at 8weeks after implantation without orthodontic force application. The appliance and the surrounding tissue were studied radiographically, macroscopically, and histologically. The results were as follows: 1. The lateral radiographs taken after euthanasia showed very slight displacement of the vortical plate in the experimental animals, compared with the control animal. Mobility test of all animals confirmed primary stability without any increase of mobility during experimental period. 2. No pathologic changes were found in the healing condition of covering soft tissue and bone-screw interface in experimental animals as well as a control animal. 3. Osseointegration was achieved in the bone-screw interface in 8weeks after implantation and the amount of osseointegration increased in 18weeks. There was little difference of osseointegration between the compression side and the tension side. 4. In the marginal bone area, slight bone apposition and resorption were found regardless of compression and tension side, while there was no change in the control animal. 5. Both 8week-animal and 18week-animal showed the new bone apposition along the surface of screws which were perforated into the nasal cavity, while the control animal showed no change. 6. After 4weeks of plate removal, the covering epithelium was repaired intactly, while the connective tissue showed loose and irregular rearrangement and the connective tissue capsule remained. The C-Palatal $Plate^{TM}$ manifested sufficient anchorage capacity in the context of histological study as well as clinical outcomes, when immediate orthodontic force was applied after implantation.