• Title/Summary/Keyword: Capacity expansion

검색결과 750건 처리시간 0.028초

암모니아-물 흡수식 열교환 사이클의 운전 특성 (Operating Characteristics of Ammonia-Water Absorber Heat Exchange Cycle)

  • 강인석;김남진;김종보
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.357-362
    • /
    • 2001
  • 충진농도, 냉매 팽창밸브 개도, 그리고 약용액의 유량 변화에 따른 벤치타입 암모니아-물 흡수식 열교환 사이클에 대한 실험을 수행한 결과 시스템의 충진농도가 증가할수록 냉방능력이 증가하였으며, 최적의 충진농도가 존재함을 알았다. 그리고 냉매 팽창 밸브의 개도는 응축기 출구의 직접적인 영향을 주고 있으며 최적의 과냉도가 0~4$^{\circ}C$임을 알았다. 또한 약용액의 유량이 증가시킬수록 증발압력과 강용액의 농도가 즐어들었으며, 냉방능력과 COP가 최대가 되는 최적의 약용액 유량이 존재하였다.

  • PDF

High Efficient Control Design for Refrigeration System of a Ship

  • Hua, Li
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.241-244
    • /
    • 2006
  • In this paper, we suggest the high efficient control method based on general PI control law to control the refrigeration system of the ship effectively. In the variable speed refrigeration system, the capacity and the superheat are controlled by inverters and electronic expansion valves respectively for saving energy and improving cost performance. Thus, we propose decoupling model to eliminate the interfering at first. Next, we design PI controller to control capacity and superheat independently. Finally the control performance was investigated through some experiments. The experiments results show that the PI control design can obtain good control performance deal with the varied control reference and thermal load.

  • PDF

A novel drying process for oil adsorption of expanded graphite

  • Park, Soo-Jin;Lee, Seul-Yi;Kim, Ki-Seok;Jin, Fan-Long
    • Carbon letters
    • /
    • 제14권3호
    • /
    • pp.193-195
    • /
    • 2013
  • Expanded graphite (EG) was prepared using a drying process for application as an oil-adsorbent: the morphology, expansion volume, and oil absorption capacity of the EG were investigated. The expanded volume of the EG increased with an increasing reaction time and heat treatment temperature. The oil adsorption capacity of the EG was 45 g of n-dodecane per 1 g of EG. It is noted that the drying process of EG is a useful technique for a new oil-adsorbent.

Development and Applications of Membrane Technology in Korea

  • Noh, S.H.
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 추계 총회 및 학술발표회
    • /
    • pp.74-79
    • /
    • 1995
  • In the last 10 years, membrane science and technology in Korea have grown fast in terms of basic research and process applications. Even the first large commercial membrane plant in Korea was an ion-exchange membrane process built in 1975 for the production of table salt with an annual capacity of 150,000 tons of salt, membrane processes could not draw general interests from industry not until 1987 when a reverse osmosis plant for the production of process water with a capacity of 10,000 m$^3$/day was built by Kugdong Petroleum Co. Today, the production of water by RO over the capacity of 140,000 m$^3$/day is in operation or under construction in Korea. Consumption of ultra pure water increases sharply in recent years mainly due to the rapid expansion of semiconductor industry and the introduction of ultra high pressure boilers for power plants.

  • PDF

각형강관을 사용한 고강도 콘크리트 전단벽체에 대한 실험적 연구 (An Experimental Study on the High-Strength Concrete Shear Wall using Rectangular Steel Tubes)

  • 최기봉;조순호;김명준;오종환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.460-467
    • /
    • 1997
  • Compared to normal-strength concrete, high-strength concrete has the lower lateral expansion capacity caused by the higher elastic modulus and the lower internal crack characteristic. Therefore, the effect of the lateral confining action of hoops appears slowly and also in inefficient Nevertheless. it has been reported that the strength and deformation capacity of high-strength concrete is improved by well-distributed hoops. Due to that argument, this investigation has been compared and analyzed by the experimental works on the deformation capacity and the confinement mechanism of high-strength concrete shear wall of the high-rise building reinforced by rectangular steel tubes and rectangular hoops at both edges of the shear wall.

  • PDF

수치적 모델링을 통한 이산화탄소 급탕기의 특성 연구 (Studies on Performance of CO2 Water Heater by Numerical Modeling)

  • 박한빛;윤린
    • 설비공학논문집
    • /
    • 제25권1호
    • /
    • pp.20-27
    • /
    • 2013
  • Numerical modeling of $CO_2$ water heater was conducted prior to optimal design of medium and large sized $CO_2$ water heater, and the experimental test with small sized $CO_2$ water heater having heat capacity of 4 kW was completed to verify the present numerical model. The present model estimated the experimental data of COP(coefficient of performance), heating capacity, and the hot water outlet temperature within the range of 3% to 8% of mean deviation. As increase of EEV(electric expansion valve) opening area, decreasing of heating capacity and the hot water outlet temperature, and increasing of COP were found in both experimental and numerical investigation.

회피비용을 고려한 EGEAS 모형 개발과 전원개발계획의 최적화 (A Modified EGEAS Model with Avoided Cost and the Optimization of Generation Expansion Plan)

  • 이재관;홍성의
    • 경영과학
    • /
    • 제17권1호
    • /
    • pp.117-134
    • /
    • 2000
  • Pubilc utility industries including the electric utility industry are facing a new stream of privatization com-petition with the private sector and deregulation. The necewssity to solve now and in the future power supply and demand problems has been increasing through the sophisticated generation expansion plan(GEP) approach con-sidering not only KEPCo's supply-side resources but also outside resources such as non-utility generation(NUG) demand-side management (DSM). Under the environmental situation in the current electric utility industry a new approach is needed to acquire multiple resources competitively. This study presents the development of a modified electric generation expansion analysis system(EGEAS) model with avoided cost based on the existing EGEAS model which is a dynamic program to develope an optimal generation expansion plan for the electric utility. We are trying to find optimal GEP in Korea's case using our modified model and observe the difference for the level of reliabilities such as the reserve margin(RM) loss of load probability(LOLP) and expected unserved energy percent(EUEP) between the existing EGEAS model and our model. In addition we are trying to calculate avoided cost for NUG resources which is a criterion to evaluate herem and test possibility of connection calculation of avoided cost with GEP implementation using our modified model. The results of our case study are as follows. First we were able to find that the generation expansion plan and reliability measures were largely influenced by capacity size and loading status of NUG resources, Second we were able to find that avoided cost which are criteria to evaluate NUG resources could be calculated by using our modified EGEAS model with avoided cost. We also note that avoided costs were calculated by our model in connection with generation expansion plans.

  • PDF

탄소 피복된 SnO2-SiO2 음극활물질의 전기화학적 특성 (Electrochemical Characteristics of Carbon Coated SnO2-SiO2 Anode Materials)

  • 정구현;나병기
    • 청정기술
    • /
    • 제19권1호
    • /
    • pp.44-50
    • /
    • 2013
  • 리튬이온전지에서 음극활물질의 저장용량을 증가시키기 위하여 주석산화물에 대한 연구가 많이 수행되고 있다. 주석산화물은 기존의 흑연 음극활물질보다 충방전 용량이 높다. 하지만 충방전이 진행되는 동안에 부피팽창률이 높아서 활물질이 파괴되는 현상이 나타나므로 과도한 비가역용량이 문제가 된다. 이를 해결하기 위하여 물리적 완충역할을 하는 물질이 첨가된 복합산화물을 제조하였다. $SnO_2-SiO_2$ 복합산화물을 솔-젤법을 이용하여 제조하였다. 10 vol% 프로필렌기체를 이용하여 탄소피복을 하여 전기전도성을 증가시켰다. TG/DTA, XRD, SEM과 FT-IR을 이용하여 제조된 물질의 물성을 분석하였으며, CR2032 코인셀을 제조하여 전기화학적인 특성을 조사하였다. $300^{\circ}C$로 열처리한 후에 탄소피복한 $SnO_2-SiO_2$ 활물질의 전기화학적 특성이 가장 우수하였다.

Effect of Posterior-Anterior Mobilization of the Thoracic Spine on Pain, Respiratory Function, and Thoracic Circumference in Patients With Chronic Low Back Pain

  • Park, Ju-jung;Chon, Seung-chul
    • 한국전문물리치료학회지
    • /
    • 제25권4호
    • /
    • pp.37-45
    • /
    • 2018
  • Background: Posterior-anterior (PA) vertebral mobilization, a manual therapy technique has been used for relieving pain or stiffness treating in spinal segment for in clinical practice, however evidence to gauge efficacy is yet to be synthesised. Objects: This study aimed to investigate the effect of PA mobilization of the thoracic spine on the respiratory function in patients with low back pain (LBP). Methods: The study participants included 30 patients with chronic LBP. They were randomly allocated to the experimental and control groups. The experimental and control groups received PA mobilization of the T1-T8 level of the thoracic spine and placebo mobilization, respectively. All patients received interventions for 35 minutes a day, five times a week, over 2-week period, respectively. Forced vital capacity (FVC), forced expiratory volume in 1 second ($FEV_1$), peak expiratory flow (PEF), forced expiratory flow 25~75% ($FEF_{25{\sim}75%}$), and chest wall expansion were measured before and after the intervention. Statistical analysis was performed using independent t-test and two-way analysis of variance, and Pearson's correlation analysis was used to compare the correlation between respiratory function and chest measurement. Results: The experimental group showed significant improvements in FVC, $FEV_1$, PEF, $FEF_{25{\sim}75%}$ (p<.05), and chest wall expansion (p<.05) compared with the control group. Conclusion: PA mobilization of the upper thoracic spine may be beneficial for improving respiratory function parameters including FVC, $FEV_1$, PEF, $FEF_{25{\sim}75%}$, and chest wall expansion in patients with chronic LBP.

활성슬러지 하수처리시설 운영 및 유지관리를 위한 시스템다이내믹스 모델의 모의에 관한 연구 (Simulations of a System Dynamics Model for Operations and Maintenance of Activated-Sludge Wastewater Treatment Plants)

  • 박수완;김봉재;전환돈;김인철
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.905-912
    • /
    • 2006
  • In this paper, simulation methods of the system dynamics model developed by Das et al. (1997) for activated-sludge wastewater treatment plants are illustrated in an attempt to determine the operating rules and the policies related to capacity expansion of an activated-sludge wastewater treatment plant. For existing conditions, the analyses were performed by varying activated-sludge return rate to observe changes in effluent water quality and treatment efficiency. The effluent water quality is also analyzed for various average daily inflow conditions and activated-sludge return rates. As a result, without expanding the aeration tank, maximum average daily inflow that can satisfy the effluent water quality standard of BOD $0.02kg/m^3$ was determined as $2,840m^3/hr$, subject to 100% of activated-sludge return rate while other factors remain constant. When the activated-sludge return rate is less than 100%, expansion of the aeration tank is necessary and minimum sizes of the aeration tank to satisfy the effluent water quality standard were determined for various activated-sludge return rates. In addition, the total operating and maintenance as well as unit treatment cost regression equations for activated-sludge wastewater treatment plants are suggested by using the cost data that are obtained from Water and Wastewater Division, Ministry of Environment. The regression analyses showed that the economies of scale phenomena exist in the operating and maintenance costs of activated-sludge wastewater treatment plants.