• 제목/요약/키워드: Capacitor Quality

검색결과 196건 처리시간 0.024초

A Simplified Control Algorithm for Three-Phase, Four-Wire Unified Power Quality Conditioner

  • Singh, Bhim;Venkateswarlu, P.
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a simplified control algorithm for a three-phase, four-wire unified power quality conditioner (UPQC) is presented to compensate for supply voltage distortions/unbalance, supply current harmonics, the supply neutral current, the reactive power and the load unbalance as well as to maintain zero voltage regulation (ZVR) at the point of common coupling (PCC). The UPQC is realized by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The shunt AF is realized using a three-phase, four leg voltage source inverter (VSI) and the series AF is realized using a three-phase, three leg VSI. A dynamic model of the UPQC is developed in the MATLAB/SIMULINK environment and the simulation results demonstrating the power quality improvement in the system are presented for different supply and load conditions.

Coordinated Control Strategies with and without Circulating Current in Unified Power Quality

  • Feng, Xing-tian;Zhang, Zhi-hua
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1348-1357
    • /
    • 2015
  • Under traditional unified power quality conditioner (UPQC) control, a UPQC series converter (SC) is mainly used to handle grid-side power quality problems while its parallel converter (PC) is mainly used to handle load-side power quality problems. The SC and PC are relatively independent. The SC is usually in standby mode and it only runs when the grid voltage abruptly changes. In this paper, novel UPQC coordinated control strategies are proposed which use the SC to share the reactive power compensation function of the PC especially without grid-side power quality problems. However, in some cases, there will be a circulating current between the SC and the PC, which will probably influence the compensation fashion, the compensation capacity, or the normal work of the UPQC. Through an active power circulation analysis, strategies with and without a circulating current are presented which fuses the reactive power allocation strategy of the SC and the PC, the composite control strategy of the SC and the compensation strategy of the DC storage unit. Both of the strategies effectively solve the SC long term idle problem, limit the influence of the circulating current, optimize all of the UPQC units and reduce the production cost. An analysis, along with simulation andexperimental results, is presented to verify the feasibility and effectiveness of the proposed control strategies.

단상용 통합형 전력품질 개선장치의 개발에 관한 기초연구 (A Basic Study on the Development of the Single-Phase Unified Poorer Quality Conditioner)

  • 노대석;이현옥;오성철;최재석;차준민;김재언
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권2호
    • /
    • pp.90-98
    • /
    • 2003
  • Recently, the increasing application of electronic equipments and information devices has heightened the interest in power qualify. The term power quality is applied to a wide range of electromagnetic phenomena on the power system and is also concentrated by all areas such as utilities, their customers and suppliers of load equipments. In engineering terms, power Qualify is expressed by voltage qualify because the power supply system can only control the quality of the voltage. Therefore, the standards in power quality area are devoted to keep the supply voltage within allowable limits. This paper deals with single-phase unified power quality conditioner (UPQC), which ai s at the integration of series-active and shunt-active filter. The series filter il used to compensate for the voltage distortions and the shunt filter is used to provide reactive power and counteract the harmonic current injected by the load. Also, the voltage of the DC link capacitor is controlled to a desired value by the shunt active filter. The validity of the proposed UPQC is demonstrated using both the MATLAB/SIMULINK simulation and the experimental device with DSP (TMS320C32).

축소형 부하불평형 보상장치의 개발 및 시험 (Development and Operation of Small-Scaled Equipment for Improving Unbalanced Load in Railway)

  • 김주락;한문섭;강문호;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.809-815
    • /
    • 2007
  • This paper proposes the analysis on new equipment for power quality in electrified railway. The proposed equipment consists of series and parallel inverter. Each inverter is connected by capacitor as dc link. This structure can be compensated for active and reactive power in catenary through transformer.

  • PDF

부하불평형 해소를 위한 축소형 보상설비 개발 (Development of the down-scaled compensator for the solution of unbalanced load)

  • 김주락;한문섭;이장무;정호성;박현준;강문호;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.649-654
    • /
    • 2005
  • This paper proposes analysis on new equipment for power quality in electric railway. The proposed equipment consists of series inverter and parallel inverter. Each inverter is connected by capacitor as dc link. This structure can be compensated for active and reactive power in catenary through transformer.

  • PDF

전기철도용 축소형 부하불평형 보상설비 개발 (Development of Small-Scaled Equipment for Improving Unbalanced Load in Railway)

  • 김주락;강문호;김정훈;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.921-927
    • /
    • 2006
  • This paper proposes the analysis on new equipment for power quality in electrified railway. The proposed equipment consists of series and parallel inverter. Each inverter is connected by capacitor as dc link. This structure can be compensated for active and reactive power in catenary through transformer.

  • PDF

대용량 고압모터 고장원인 정밀 분석 (An Exactness Analysis for Damage Cause of Large-Capacitor and High-Voltage Motor)

  • 홍성택;이은춘;신강욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.259-261
    • /
    • 2000
  • This paper demonstrates the trip of high-voltage motor(6.6kV 4,600Hp). To analyze the causes of damage in motors. exactness analysis of electricity system, analysis inspection of motor and voltage quality analysis fiery development were investigated. This result propose to improvement system and repair method.

  • PDF

하이브리드 에너지 저장장치의 계통연계 제어 (Grid-Connected Control of Hybrid Energy Storage)

  • 이언석;강병극;최용오;정세교;오세승;채수용;송유진
    • 한국철도학회논문집
    • /
    • 제18권4호
    • /
    • pp.325-334
    • /
    • 2015
  • 본 논문에서는 하이브리드 에너지 저장장치의 계통연계 제어에 대하여 기술 하였다. 배터리는 큰 에너지 밀도를 가지지만 순간 전력밀도는 낮아 급격한 전류변동이 일어날 경우 수명이 저하된다. 이러한 단점을 보완하기 위해 수퍼커패시터를 함께 사용하는 하이브리드 에너지 저장장치를 구성하였고 이에 대한 제어방법을 제안하였다. 배터리와 수퍼커패시터의 제어를 위해서는 예측형 전류제어기를 가지는 p-q 제어방법을 적용하였다. 제안된 제어기의 효용성을 검증하기 위해 실제 계통모델에 대한 PSIM과 RTDS를 이용한 시뮬레이션을 수행하였다.

PV와 PEFC를 병용한 가정용 분산 전원 시스템의 전력평준화 제어법 (Power Balancing Control Method of A Residential Distributed Generation System using Photovoltaic Power Generation and Polymer Electrolyte Fuel Cells)

  • 윤영변;문상필;박한석;우경일
    • 전기학회논문지P
    • /
    • 제65권4호
    • /
    • pp.335-339
    • /
    • 2016
  • Output power in photovoltaic systems changes steeply with the change of the sun intensity. The change of output power has influence on the electric power quality of the system. This paper proposes a residential distributed generation system using photovoltaic power generation and polymer electrolyte fuel cells(hybrid systems). In order to level the output power which changes steeply the polymer electrolyte fuel cells are connected to the photovoltaic power generation system in parallel. Thus the generated power of all the system can be leveled. However, the steep generated power in the photovoltaic power generation system can not be leveled. Therefore, the electric double layer capacitor(EDLC) is connected in parallel with the hybrid systems. It is confirmed by the simulation that the proposed distributed generation system is available for a residential supply.

저감된 DC Link Capacitor 부피를 가지는 역률 개선 Valley-Fill Flyback 컨버터의 설계 및 구현 (Practical Design and Implementation of a Power Factor Correction Valley-Fill Flyback Converter with Reduced DC Link Capacitor Volume)

  • 김세민;강경수;공성재;유혜미;노정욱
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.277-284
    • /
    • 2017
  • For passive power factor correction, the valley fill circuit approach is attractive for low power applications because of low cost, high efficiency, and simple circuit design. However, to vouch for the product quality, two dc-link capacitors in the valley fill circuit should be selected to withstand the peak rectified ac input voltage. The common mode (CM) and differential mode (DM) choke should be used to suppress the electromagnetic interference (EMI) noise, thereby resulting in large size volume product. This paper presents the practical design and implementation of a valley fill flyback converter with reduced dc link capacitors and EMI magnetic volumes. By using the proposed over voltage protection circuit, dc-link capacitors in the valley fill circuit can be selected to withstand half the peak rectified ac input voltage, and the proposed CM/DM choke can be successfully adopted. The proposed circuit effectiveness is shown by simulation and experimentally verified by a 78W prototype.