• Title/Summary/Keyword: Capacitor

Search Result 3,820, Processing Time 0.037 seconds

Design Technique Using Bypass Capacitor to Improve Antenna Efficiency of Inverted-F Antenna with Band Stop Matching Circuit (Band Stop Matching Circuit이 적용된 Inverted-F Antenna의 Bypass Capacitor를 이용한 안테나 효율 향상 기법)

  • Bae, Jang Hwan;Choi, Woo Cheol;Lim, Seonho;Yoon, Young Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • In this paper, a design technique using a bypass capacitor is proposed to improve the antenna efficiency of an inverted-F antenna (IFA) with a band stop matching circuit (BSMC). The proposed antenna operates in the LTE bands 26 and 5(814~ 894 MHz). The bandwidth of the IFA is expanded from 803~863 MHz to 800~888 MHz using the impedance change caused by the BSMC. To enhance the antenna efficiency in the expanded frequency band, the bypass capacitor is applied to the IFA with the BSMC. The bypass capacitor improves the efficiency of the antenna by reducing the current variation of the IFA with the BSMC. The proposed antenna has a bandwidth of 804~895 MHz and the antenna efficiency increases by more than 10 % in the extended frequency band by using the bypass capacitor.

Operating Characteristics in LCLC Resonant Converter with A Low Coupling Transformer. (낮은 커플링 변압기를 갖는 LCLC 공진컨버터 동작특성)

  • Kong Young-Su;Kim Eun-Soo;Lee Hyun-Kwan;Cho Jung-Goo;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.7
    • /
    • pp.343-350
    • /
    • 2005
  • Conventionally, for transferring the primary power to the secondary one, the high frequency series resonant converter has been widely used for the contactless power supply system. However, the high frequency series resonant converter has the disadvantages such as the low efficiency, the high voltage gain characteristics and deviation of the phase angle in the overall load range. To improve this disadvantages, In this paper, the characteristics of the high efficiency and unit voltage gain as well as in-phase are revealed in the proposed three-level LCLC (Inductor-Capacitor- Inductor-Capacitor) resonant converter. The results are verified on the simulation based on the theoretical analysis and the 4kW experimental Prototype.

Series Voltage Compensation Systems for Voltage Sag by Using an Environmentally Friendly Ultra-capacitor (친환경 Ultra-capacitor에 의한 순시전압강하의 직렬전압보상 시스템)

  • Shon, Jin-Geun;Jeon, Hee-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.763-769
    • /
    • 2009
  • A series voltage compensation(SVC) system is a power-electronics controller that can protect sensitive loads from disturbance in the supply system. Especially, voltage sags are considered the dominant disturbances affecting the power quality. This paper dealt with a system of off-line type voltage sag compensation by using a bi-directional DC/DC converter of environmentally friendly ultra-capacitor. This capacitor is attached to the DC link of SVC through the high-efficiency DC/DC converter in order to compensate the DC link voltage drop during short-term power interruption as voltage sags. Therefore, in this paper, a DC/DC converter to control high-efficiency energy of ultra-capacitor and voltage sag detection algorithm of off-line type SVC systems are newly introduced. According to the results of experimental of prototype system, it is verified that the proposed system has effectiveness of voltage sag compensation using an ultra-capacitor.

Harmonic Analysis of Reactor and Capacitor in Single-tuned Harmonic Filter Application

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Dong-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.239-244
    • /
    • 2011
  • Industrial power distribution system includes many kinds of non-linear loads, which produce the harmonics during energy conversion transition. The single-tuned passive filter is widely used to absorb the harmonics and attenuate its undesirable effect in the distribution system. However, the passive filter might be severely stressed, and sometimes even damaged, due to the absorption of harmonics. There is voltage rise on the capacitor when the single-turned harmonic filter is applied. When the capacitor voltage rose above the allowable limit, the expected life of the capacitor will considerably deteriorate. On the other hand, the reactor can experience the spike voltage even if the voltage and current of the capacitor are within the allowable limit, and this accumulated voltage stress of the reactor causes its premature fault. In this paper, we analyzed and compared the harmonic voltage and current of the reactor and capacitor in a single-tuned harmonic filter through the EMTP software and verified them with the experimental results.

Characteristics Analysis of Capacitor and Reactor for Harmonic Filter (고조파 필터용 커패시터와 리액터의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Recently, application of non-linear load is gradually increased. Non-linear load produces harmonic components of current during the energy conversion transition. Passive filter is used for reducing of harmonics in the user power systems. This filter, which is composed of capacitor and reactor, frequently get out of order by electrical stress. There are voltage and current increase when capacitor and reactor are applied in the user's filter systems. If increased voltage and current is above stipulated values, they have severely an influences on the life of capacitor and reactor. This paper describes that the voltage and current of capacitor used for filter is within the limits of allowable values, but reactor is beyond the limits and reveals spike voltage. Therefore this phenomenon brings about premature fault of reactor and capacitor.

A Study on the Characteristic of Capacitor by Asymmetrical Voltage Unbalance (비대칭 전압 불평형에 의한 커패시터 동작 특성)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • As the increasing of Non-linear load, we have been growing interest for the harmonics. Harmonics has been focused on the current component rather than voltages. Voltage harmonics can be mainly generated at the PCC with non-linear load and act on voltage unbalance. Voltage harmonics can be enlarged at the capacitor with low impedance as frequency increases. Capacitor is basically used for the power-factor compensation and sometimes as the passive filter. Small voltage of low-order acts on quite a few at the capacitor by the current increase. Capacitor has easily fall under by harmonic components. In this paper, we measured the magnitude and phase angle of asymmetrical voltage with harmonics components at the PCC and calculated with the same condition. we concluded that voltage harmonics of higher order increase each current component but have a little effect on capacitor rating.

Optimization of Capacitor Threshold VT Implantation for Planar P-MOS DRAM Cell (평면구조 P-MOS DRAM 셀의 커패시터 VT 이온주입의 최적화)

  • Chang Sung-Keun;Kim Youn-Jang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.2
    • /
    • pp.126-129
    • /
    • 2006
  • We investigated an optimized condition of the capacitor threshold voltage implantation(capacitor $V_T$ Implant) in planar P-MOS DRAM Cell. Several samples with different condition of the capacitor $V_T$ Implant were prepared. It appeared that for the capacitor $V_T$ Implant of $BF_2\;2.0{\times}l0^{13}\;cm^{-2}$ 15 KeV, refresh time is three times larger than that of the sample, in which capacitor $V_T$ Implant is in $BF_2\;1.0{\times}l0^{13}\;cm^{-2}$ 15 KeV. Raphael simulation revealed that the lowed maximum electric field and lowed minimum depletion capacitance ($C_{MIN}$) under the capacitor resulted in well refresh characteristics.

Analysis of embedded capacitor using Flexible PCB (Flexible PCB를 이용한 내장형 캐패시터의 분석)

  • Yoo, Joshua;Kim, J.W.;Yoo, M.J.;Park, S.D.;Lee, W.S.;Lee, H.G.;Kang, N.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.150-152
    • /
    • 2004
  • The number of layers in rigid PCB(printed circuit board) is restricted, so the number of components can be embedded in module is restricted also. But using flexible multilayer PCB, the layers over than 7 can be evaluated. In this study, to verify the possibility of application of flexible multilayer PCB to RF modules, multilayered embedded capacitor is fabricated and analyzed. The characteristics of embedded capacitor is analyzed and compared to that of MLCC and LTCC capacitor. Embedded capacitor has better electrical features than MLCC and compatible one to LTCC capacitor.

  • PDF

Comparative Analysis of Charging Modes of Series Resonant Converter for an Energy Storage Capacitor (에너지저장 커패시터의 최적 충전을 위한 직렬공진형 컨버터의 운용 모드 비교)

  • Lee, Byung-Ha;Kang, Tae-Sub;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.394-400
    • /
    • 2012
  • In this paper, charging modes of series resonant converter for a high voltage energy storage capacitor are compared in terms of charging time, peak resonant current, normalized peak resonant current and voltage in each operation mode. Operating principles of the full bridge series resonant converter with capacitor load are explained and analyzed in discontinuous and continuous operation mode. Based on the analysis and simulation result, $0.6{\omega}_r$ < ${\omega}_s$ < $0.75{\omega}_r$ and $1.3{\omega}_r$ < ${\omega}_s$ < $1.4{\omega}_r$ are evaluated to the best range of switching frequency for charging of an high voltage energy storage capacitor. 1.8 kJ/s SRC prototype is assembled with TI 28335 DSP controller and 40 kJ, 7 kV energy storage capacitor. Design rules based on the comparative analysis are verified by experiment.

Study of Back-Up Electric Power Source as a Role for Instant Power Industry Safety by Super Capacitor (순간 정전시 산업안전용 보조전원 역할의 Super Capacitor에 관한 연구)

  • 김상길;김종철;허진우;김경민;이용욱;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 1999.11a
    • /
    • pp.345-354
    • /
    • 1999
  • A new type of capacitor named "Super Capacitor" has been developed, in which the properties of electric double layer formed at the interface of activated carbon electrode- liquid organic electrolyte is applied. This capacitor is small In size, light in weight, wide In temperature range(-25~$70^{\circ}C$), large in charge-discharge capability and good in voltage preservation. And this super capacitor is applied as a power back-up for electricity failure in volatile memory devices etc., a power source for a short time and a power source for operating actuators. At present the development of high power back-up types of the capacitor system and improvement of their characteristics are being actively conducted in order to find wider applications.lications.

  • PDF