• 제목/요약/키워드: Calibration source

검색결과 387건 처리시간 0.03초

Source-Follower Type Analog Buffer Using Low Temperature Poly-Si TFTs for AMLCDs

  • Chen, Bo-Ting;Tai, Ya-Hsiang;Wei, Ying-Jyun;Tsai, Chun-Chien;Chen, Hsu-Hsin;Huang, Chun-Yao;Kuo, Yu-Ju;Cheng, Huang-Chung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1243-1246
    • /
    • 2006
  • A new source follower circuit for the integrated circuit of AMLCDs is proposed. Active load is added and calibration operation is applied to compensate the circuits. Proposed circuit is capable of minimizing the variation from both timing and device variations through measured results, the uniformity and bias effect are discussed.

  • PDF

Multi-frequency bands receiver system and its test observation results

  • 한석태;전파기술개발센터원;전파천문연구본부원
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.127.1-127.1
    • /
    • 2011
  • Over the past several years the millimeter wave VLBI(Veryl Long Baseline Interferometry) observations have been intensively carried out. However In millimeter and sub-millimeter waves observations for VLBI, it is crucial to calibrate correctly the phase variations of the electromagnetic waves propagation through the troposphere. To do this, KVN(Korean VLBI Network) has a unique multi-frequency bands receiver system which is able to perform the simultaneous observations in up to four bands such as 22, 43, 86, and 129GHz. The phase of a source at 22GHz can be used to calibrate the phase of the same source at higher frequency bands. The phase calibration using multi-frequency bands receiver system is possible because the phase fluctuations from a given amount of waver vapor increase linearly with frequency. That is to say that troposphere is non-dispersive property in terms of tropospheric delay fluctuations. In this talk, We present results of test observation for multi-frequency bands receiver system.

  • PDF

PSD 센서를 이용한 이동물체의 실시간 위치측정 (Real-time position measurements of mobile object using PSD sensor)

  • 노재희;권석근;서남일;노영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.540-542
    • /
    • 1998
  • The Position Sensitive Detector(PSD) is an useful device which can be used to measure the position of an incidence light in accuracy and in real-time. In this paper, 2-D PSD sensor is used to measure the 2-D position of moving object with light source. To get the position of light source from PSD sensor exactly, we propose two position computation methods ; the parameter calibration and neural network. Experimental data is presented that offer the comparision between two methods and demonstrates the effectiveness of proposed approach.

  • PDF

Calibration of cylindrical NaI(Tl) gamma-ray detector intended for truncated conical radioactive source

  • Badawi, Mohamed S.;Thabet, Abouzeid A.
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1421-1430
    • /
    • 2022
  • The computation of the solid angle and the detector efficiency is considering to be one of the most important factors during the measuring process for the radioactivity, especially the cylindrical γ-ray NaI(Tl) detectors nowadays have applications in several fields such as industry, hazardous for health, the gamma-ray radiation detectors grow to be the main essential instruments in radiation protection sector. In the present work, a generic numerical simulation method (NSM) for calculating the efficiency of the γ-ray spectrometry setup is established. The formulas are suitable for any type of source-to-detector shape and can be valuable to determine the full-energy peak and the total efficiencies and P/T ratio of cylindrical γ-ray NaI(Tl) detector setup concerning the truncated conical radioactive source. This methodology is based on estimate the path length of γ-ray radiation inside the detector active medium, inside the source itself, and the self-attenuation correction factors, which typically use to correct the sample attenuation of the original geometry source. The calculations can be completed in general by using extra reasonable and complicate analytical and numerical techniques than the standard models; especially the effective solid angle, and the detector efficiency have to be calculated in case of the truncated conical radioactive source studied condition. Moreover, the (NSM) can be used for the straight calculations of the γ-ray detector efficiency after the computation of improvement that need in the case of γ-γ coincidence summing (CS). The (NSM) confirmation of the development created by the efficiency transfer method has been achieved by comparing the results of the measuring truncated conical radioactive source with certified nuclide activities with the γ-ray NaI(Tl) detector, and a good agreement was obtained after corrections of (CS). The methodology can be unlimited to find the theoretical efficiencies and modifications equivalent to any geometry by essential sufficiently the physical selective considered situation.

Simple Spectral Calibration Method and Its Application Using an Index Array for Swept Source Optical Coherence Tomography

  • Jung, Un-Sang;Cho, Nam-Hyun;Kim, Su-Hwan;Jeong, Hyo-Sang;Kim, Jee-Hyun;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • 제15권4호
    • /
    • pp.386-393
    • /
    • 2011
  • In this study, we report an effective k-domain linearization method with a pre-calibrated indexed look-up table. The method minimizes k-domain nonlinear characteristics of a swept source optical coherence tomography (SS-OCT) system by using two arrays, a sample position shift index and an intensity compensation array. Two arrays are generated from an interference pattern acquired by connecting a Fabry-Perot interferometer (FPI) and an optical spectrum analyzer (OSA) to the system. At real time imaging, the sample position is modified by location movement and intensity compensation with two arrays for linearity of wavenumber. As a result of evaluating point spread functions (PSFs), the signal to noise ratio (SNR) is increased by 9.7 dB. When applied to infrared (IR) sensing card imaging, the SNR is increased by 1.29 dB and the contrast noise ratio (CNR) value is increased by 1.44. The time required for the linearization and intensity compensation is 30 ms for a multi thread method using a central processing unit (CPU) compared to 0.8 ms for compute unified device architecture (CUDA) processing using a graphics processing unit (GPU). We verified that our linearization method is appropriate for applying real time imaging of SS-OCT.

주파수영역 광 간섭 단층촬영 시스템을 위한 파장가변 광원 및 신호처리계의 구현 (Implementation of the Wavelength-Swept-Source and Signal Processing for the Frequency Domain Optical Coherence Tomography)

  • 이응제;김용평
    • 한국광학회지
    • /
    • 제18권5호
    • /
    • pp.309-316
    • /
    • 2007
  • 주파수영역 광 간섭 단층촬영 시스템을 위한 파장가변 광원과 주파수 보정(calibration)을 위한 신호처리계를 구현하였다. 제작된 레이저의 평균출력을 부스터(booster) 반도체 광 증폭기를 이용하여 14 mW까지 증폭시키고, 레이저 스펙트럼의 편이(shift)를 보상하였다. 패브리-페롯 에탈론(Fabry-Perot etalon)과 디지털 신호처리(digital signal processing)로 신호처리계를 제작함으로서 파장가변광원의 속도가변에 따른 비트주파수(beat frequency)의 넓어짐을 보정하였다. 제작된 광 간섭 단층촬영 시스템은 종방향 주사속도 154.4 kHz, 측정깊이 0.95 mm, 종방향 분해능 $12{\pm}0.37{\mu}m$의 특성을 가진다.

NaI(T1) 검출기 스펙트럼의 에너지-채널 관계 자동결정 (Automatic Determination of the Energy Pulse-height Relationship in NaI(TI) Spectra)

  • 이모성
    • Journal of Radiation Protection and Research
    • /
    • 제22권3호
    • /
    • pp.143-151
    • /
    • 1997
  • NaI(TI) 검출기의 파고는 용도에 따라 변하기 때문에, 온도 변화는 분광분석기의 에너지 교정에 영향을 미친다. 외부 선원을 사용하여 파고의 온도 의존성을 보상할 수 있으나 이것은 바람직하지 않은 콤프턴 영향을 야기한다. 이 연구에서는 환경중의 감마선 스펙트럼에서 뚜렸한 $^{212}Pb$로부터의 239 keV 피크, $^{214}Pb$로부터의 351 keV 피크, 40K로부터의 1460 keV 피크, $^{208}Tl$으로 부터의 2614 keV 피크를 에너지 교정의 기준 피크로 사용하였다. 이들 피크를 이용하는 방법은 마이크로소프트사의 Visual Basic으로 프로그램화하였다. 이렇게 개발된 프로그램은 신뢰성과 적용성을 검증하기 위해 $-20^{\circ}C$ 부터 $10^{\circ}C$까지 변하는 온도에서 30분 간격으로 측정한 환경 스펙트럼에 적용하였다. 그 결과로써 일상의 기온에서 측정한 $3'{\times}3'$ NaI(Tl) 검출기의 스펙트럼에 대해 이 방식의 에너지 교정은 효과적임이 입증되었다.

  • PDF

고선량 Co-60 선원이용시 차폐된 질 원주기구의 영향 (Dose Distributions in a Shielded Vaginal Cylinder using a HDR Co-60 Source)

  • 김진기;김정수;김형진;권형철;강정구
    • 한국의학물리학회지:의학물리
    • /
    • 제8권1호
    • /
    • pp.37-45
    • /
    • 1997
  • 차폐된 질 원주기구를 이용한 강내치료시 Co-60 선원에 대한 정확한 흡수선량을 결정 하고자 선원을 교정하고, 질 원주기구에 의한 선량분포변화를 조사하였다. 선량분포의 변화량은 직경 2.5 cm 차폐된 질 원주기구를 폴리스틸렌 팬톰에 설치하여 전리함으로 측정하였으며, 부채꼴 모양인 0.55cm 두께의 9$0^{\circ}C$ 연으로 차폐된 면과 차폐되지 않은 면의 선량분포에 대한 영향을 상대선량 감소율로 측정하였다. 측정된 선량분포의 변화량을 제작사의 선량분포도 및 다점 분할방식으로 구한 선량율표와 비교하였다. 질 원주기구를 이용한 선량 감소율은 차폐되지 않은 변의 경우 원주기구 표면 1cm 거리에서 4.4%를 보였고, 차폐된 면에서는 원주기구 표면에서 20.4% 를 나타냈다. 9$0^{\circ}C$연 차폐된 질 원주기구의 선량감쇄효율은 Co-60 선원에서 평균 0.2가 되었다. Co-60 이동형 선원의 선량분포는 다 점분할방식의 선량율표와 4.1% 이내로 일치하였다.

  • PDF

근거리 신호 모델을 이용한 부공간 근사 기반의 어레이 형상 추정 기법 (A Subspace-based Array Shape Estimation Method Using Nearfield Source Model)

  • 박희영;오원천;강현우;윤대희;이충용
    • 한국음향학회지
    • /
    • 제23권2호
    • /
    • pp.125-133
    • /
    • 2004
  • 참조 신호를 이용한 어레이 형상추정 기법은 일반적으로 참조 신호가 어레이로부터 충분히 먼 원거리에 위치한다고 가정하고 있다. 그러나 실제 해양 환경에서 어레이를 운용하는 경우 참조 신호와 어레이 사이의 거리는 충분히 떨어져 있지 않아 원거리 신호 모델을 바탕으로 한 기존의 기법들은 하이드로폰의 좌표 추정 시 많은 오차가 발생하게 된다 본 논문에서는 근거리 신호모델을 이용한 부공간 근사기반의 어레이 형상추정 기법을 제안하였다. 제안된 기법에서는 기준하이드로폰에 대한 시간 지연 성분을 이용하여 근거리 참조 신호를 모델링하고, 어레이 형상 추정을 위한 근거리 파라미터를 구한다. 근거리 파라미터를 이용하여 기존의 원거리 형상 추정 기법을 일반화함으로써 참조 신호의 거리에 관계없이 하이드로폰의 좌표 추정이 가능한 기법을 제안하였다. 그리고 제안된 기법의 Cramer-Rao Lower Bound를 유도하였다. 모의실험 결과 참조 신호의 거리에 관계없이 제안된 기법이 기존의 기법에 비해 보다 정확하게 하이드로폰의 좌표를 추정할 수 있음을 확인하였다.

BASINS/WinHSPF를 이용한 남한강 상류 유역의 비점오염원 저감효율평가 (A Study on BASINS/WinHSPF for Evaluation of Non-point Source Reduction Efficiency in the Upstream of Nam-Han River Watershed)

  • 윤춘경;신아현;정광욱;장재호
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.951-960
    • /
    • 2007
  • Window interface to Hydrological Simulation Program-FORTRAN (WinHSPF) developed by the United States Environmental Protection Agency (EPA) was applied to the upstream of Nam-Han river watershed to examine its applicability for loading estimates in watershed scale and to evaluate non-point source control scenarios using BMPRAC in WinHSPF. The WinHSPF model was calibrated and verified for water flow using Ministry of Construction and Transportation (MOCT, 3 stations, 2003~2005) and water qualities using Ministry of Environment (MOE, 5 station, 2000~2006). Water flow and water quality simulation results were also satisfactory over the total simulation period. But outliers were occurred in the time series data of TN and TP at some regions and periods. Therefore, it required more profit calibration process for more various parameters. As a result, all the study was performed within the expectation considering the complexity of the watershed, pollutant sources and land uses intermixed in the watershed. The estimated pollutant load for annual average about $BOD_5$, T-N and T-P respectively. Nonpoint source loading had a great portion of total pollutant loading, about 86.5~95.2%. In WinHSPF, BMPRAC was applied to evaluate non-point source control scenarios (constructed wetland, wet detention ponds and infiltration basins). All the scenarios showed efficiency of non-point source removal. Overall, the HSPF model is adequate for simulating watersheds characteristics, and its application is recommended for watershed management and evaluation of best management practices.