• Title/Summary/Keyword: Calibration process

Search Result 762, Processing Time 0.032 seconds

A Study on the Mixing Characteristics in Complex Turbulent Flow by a Laser Induced Fluorescence Method (레이저 형광여기법(LIF)를 이용한 복잡 난류유동장의 혼합특성에 관한 연구)

  • Kim, Kyung-Chun;Jeong, Eun-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.542-547
    • /
    • 2001
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera can be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration in each region after the dye infusion reflects the large scale mixing while the followed slow decay reveals the small scale mixing. The temporal change of concentration probability functions conjectures the two sequential processes in the batch type mixing. An inactive column of water existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.

  • PDF

Simultaneous Measurement of Strain and Temperature During and After Cure of Unsymmetric Composite Laminate Using Fiber Optic Sensors (비대칭 복합적층판의 성형시 및 성형후 광섬유 센서를 이용한 변형률 및 온도의 동시 측정)

  • 강동훈;강현규;김대현;방형준;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.244-249
    • /
    • 2001
  • In this paper, we present the simultaneous measurement of the fabricaition strain and temperature during and after cure of unsymmetric composite laminate uising fiber optic sensors. Fiber Bragg grating/extrinsic Fabry-Perot interferometric (FBG/EFPl) hybrid sensors are used to measure those measurands. The characteristic matrix of sensor is analytically derived and measurements can be done without sensor calibration. A wavelength-swept fiber laser is utilized as a light source. FBG/EFPI sensors are embedded in a graphite/epoxy unsymmetric cross-ply composite laminate at different direction and different location. We perform the real time measurement of fabrication strains and temperatures at two points of the composite laminate during cure process in an autoclave. Also, the thermal strains and temperatures of the fabricated laminate are measured in thermal chamber. Through these experiments, we can provide a basis for the efficient smart processing of composite and know the thermal behavior of unsymmetric cross-ply composite laminate.

  • PDF

Soot Primary Particle Size Measurement in a Ethylene Diffusion Flame Using Time-Resolved Laser-Induced Incandescence (2차원 시분해 레이저 유도 백열법을 이용한 에틸렌 확산 화염에서의 매연 입자 크기 측정)

  • Shon, Moo-Kang;Moon, Gun-Feel;Kim, Gyu-Bo;Lee, Jong-Ho;Jeong, Dong-Soo;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1140-1145
    • /
    • 2004
  • Laser-induced incandescence (LII) is introduced as a valuable tool for the characterization of nanoparticles in flame environments. This technique is based on the heating of the particles by a short laser pulse and the subsequent detection of the thermal radiation. It has been applied successfully for the investigation of soot in different fields of application. The evaluation of the temporal decay of the laser-induced incandescence (LII) signal from soot particles is introduced as a technique to obtain two-dimensional distributions of particle sizes and is applied to a laminar diffusion flame. This novel approach to soot sizing exhibits several theoretical and technical advantages compared with the established combination of elastic scattering and LII, especially as it yields absolute sizes of primary particles without requiring calibration. With this technique a spatially resolved 2-D measurement of soot primary particle sizes is feasible in a combination process form the ratio of emission signals obtained at two delay times after a laser pulse, as the cooling behavior is characteristic of particle size.

  • PDF

Non-point Source Impact Analysis through Linkage of Watershed Model and River Water Quality Model (유역모형과 하천수질모형의 연계를 통한 비점오염원 영향분석)

  • Choi, Hyun Gu;Kim, Dong Il;Kim, Ji Eun;Han, Kun Yeun
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.25-36
    • /
    • 2011
  • In this study, the accurate water quality analysis in rivers, including the non-point source is performed. First of all, watershed model, SWAT(Soil and Water Assessment Tool) was applied to analyze the impact of the non-point source in study area. And then, water quality analysis integrating the point source and the non-point source is implemented using QUALKO model. For more exact simulation, it should be the calibration and verification of variables and parameters which are needed for simulation. In addition, the importance of considering the non-point source was confirmed in river water quality simulation. BOD, TN, TP were analysed, and the results shows that BOD, TN and TP concentration was increased to 16.8%, 8.2% and 25.8% respectively. The more accurate estimate will be carried if use of reliable measurements and watershed simulation be done in models linking process. The suggested technique will improve the accuracy of the water quality analysis. The methodologies presented in this study will contribute to basin-wide water quantity and quality management.

A Technique to Efficiently Place Sensors for Three-Dimensional Robotic Manipulation : For the Case of Stereo Cameras (로봇의 3차원 작업을 위한 효율적 센서위치의 결정기법 : 스테레오 카메라를 중심으로)

  • Do, Yong-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.80-88
    • /
    • 1999
  • This paper deals with the position determination problem of stereo camera systems used as a sensor for 3D robotic manipulation. Stereo cameras having parallel rays of sight and been set up on the same baseline are assumed. The distance between the sensor and the space measured is determined so as to get insensitive parameters to the uncertainty of control points used for calibration and to satisfy the error condition set by considering the repeatability of the robot. The baseline width is determined by minimizing the mutual effect of 3D positional error and stereo image coordinate error. Unlike existing techniques, the technique proposed here is developed without complicated constraints and modelling process of the object to be observed. Thus, the technique of this paper is more general and its effectiveness is proved by simulation.

  • PDF

Development of Flight Control System and Troubleshooting on Flight Test of a Tilt-Rotor Unmanned Aerial Vehicle

  • Kang, Youngshin;Park, Bum-Jin;Cho, Am;Yoo, Chang-Sun;Koo, Sam-Ok;Tahk, Min-Jea
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.120-131
    • /
    • 2016
  • The full results of troubleshooting process related to the flight control system of a tilt-rotor type UAV in the flight tests are described. Flight tests were conducted in helicopter, conversion, and airplane modes. The vehicle was flown using automatic functions, which include speed-hold, altitude-hold, heading-hold, guidance modes, as well as automatic take-off and landing. Many unexpected problems occurred during the envelope expansion tests which were mostly under those automatic functions. The anomalies in helicopter mode include vortex ring state (VRS), long delay in the automatic take-off, and the initial overshoot in the automatic landing. In contrast, the anomalies in conversion mode are untrimmed AOS oscillation and the calibration errors of the air data sensors. The problems of low damping in rotor speed and roll rate responses are found in airplane mode. Once all of the known problems had been solved, the vehicle in airplane mode gradually reached the maximum design speed of 440km/h at the operation altitude of 3km. This paper also presents a comprehensive detailing of the control systems of the tilt-rotor unmanned air vehicle (UAV).

A Study on the Mixing Characteristics in a Rushton Turbine Reactor by a Laser Induced Fluorescence Method (레이저 형광여기법(LIF)를 이용한 러쉬톤 터빈 교반기의 혼합특성에 관한 연구)

  • Jeong, Eun-Ho;Kim, Gyeong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1145-1152
    • /
    • 2002
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields was obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera could be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter. height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration after the dye infusion reflects the large scale turbulent mixing while the fellowed slow decay reveals the small scale molecular mixing. The temporal change of concentration variance field conjectures the two sequential processes for the batch type mixing. An inactive column of water is existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.

Advancing the Gauge Block Interferometer and Automating the Gauge Block Calibration (게이지 블록 간섭계의 선진화 및 완전 자동화)

  • Kang Chu-Shik;Kim Jae-Wan;Suh Ho-Suhng;Lee Won-Kyu;Kim Jong-Ahn
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.547-550
    • /
    • 2005
  • Gauge blocks are the most widely used material measure in length field in industry. The gauge block interferometer, which is the gauge block measuring system, comprises Twyman-Green type interferometer optics and light sources having precisely known wavelengths. This paper describes the work done for advancing the measurement system and automating the measurement process. The advancing of the system was done mainly by exchanging the spectral lamp with the frequency stabilized lasers, and the automation of measurement was achieved by modifying the hardware and developing the automatic measuring software. As the results of this work, the contrast of interferometric fringes of gauge blocks longer than 100 mm s enhanced about 20 times, and the measurement time has reduced down to 50% by automation.

  • PDF

Kinetics of Oil-Proof Agent Adsorption onto Cellulose Fibers

  • Zhu, Hongxiang;Honghu, Zeng;Wang, Shuangfei;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.41 no.5
    • /
    • pp.59-65
    • /
    • 2009
  • Adsorption of an oil-proof agent (OPA)onto cellulose fibers during the papermaking process was investigated using UV-Vis spectrophotometry by measuring the OPA concentration decrease in the solution. From the calibration curve, the spectrum were converted to chemical concentrations in solution, from which the amount adsorbed onto the fiber surface could be determined. Thus, it was possible to determine the total amount adsorbed onto the fibers and in solution. Using this approach, we studied the adsorption behavior of the OPA onto the fiber surface and derived its, ${\Gamma}^s_t={\Gamma}^s_{\infty}(1-e^{-k_{\alpha}t})$. The values of the parameters kaand ${\Gamma}^s_{\infty}$ were determined using a mathematic model based on a mass transfer equation. Ultimately, a complete was derived: $Q={\alpha}{\cdot}\sum\limits_{i-1}^m{\pi}d_il_i{\cdot}M_A{\cdot}(1-e^{-k_{\alpha}t})/A_N$.

Quantitative In-line NIR measurements of papers

  • Schmidt, Angela;Weiler, Helmut
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1285-1285
    • /
    • 2001
  • For NIR measurements of papers normally diffuse reflectance accessories are used which can provide a large sampling area. The in-line process control FT-NIR spectrometer MATRIX-E enables the contactless measurement of paper samples of low silicone coat weights on label-stocks in a paper converting factory. For this study concentrations of silicone between 0 and 2 g/$m^2$ on various paper substrates were included in a quantitative method. The aim was to achieve an absolute value for the deviation from the target value of 1 g/$m^2$ during continuous movement of the paper with velocities around 400 numinute. Influences from the uncoated paper type due to supplier, color, opacity, area densities, pre-coating as well as different compounds of the agent silicone were investigated and it was found that all these papers can be represented in one PLS-model. Especially the fact that silicone as an element is present in clay coated papers is of no consequence to the measurements with MATRIX-E. Moreover during in-line installations the variation of the moisture contents in the moving paper due to variable machine velocities as well as the reflecting material of the cylinder have to be considered. It is shown that the result of the in-line calibration has the same prediction ability compared to lab scale results(Root Mean Square Error of Cross-Validation RMSECV = 0.034 g/$m^2$).

  • PDF