• 제목/요약/키워드: Calibration Factor

검색결과 437건 처리시간 0.035초

머신비젼 기반의 자율주행 차량을 위한 카메라 교정 (Camera Calibration for Machine Vision Based Autonomous Vehicles)

  • 이문규;안택진
    • 제어로봇시스템학회논문지
    • /
    • 제8권9호
    • /
    • pp.803-811
    • /
    • 2002
  • Machine vision systems are usually used to identify traffic lanes and then determine the steering angle of an autonomous vehicle in real time. The steering angle is calculated using a geometric model of various parameters including the orientation, position, and hardware specification of a camera in the machine vision system. To find the accurate values of the parameters, camera calibration is required. This paper presents a new camera-calibration algorithm using known traffic lane features, line thickness and lane width. The camera parameters considered are divided into two groups: Group I (the camera orientation, the uncertainty image scale factor, and the focal length) and Group II(the camera position). First, six control points are extracted from an image of two traffic lines and then eight nonlinear equations are generated based on the points. The least square method is used to find the estimates for the Group I parameters. Finally, values of the Group II parameters are determined using point correspondences between the image and its corresponding real world. Experimental results prove the feasibility of the proposed algorithm.

실내 모형실험을 통한 수평재하 말뚝의 거동측정을 위한 FBG 센서의 적용성 평가 (Application of FBG Sensors on a Cantilever Beam for Analyzing Behavior of Laterally Loaded Piles)

  • 이태희;정원석;정영훈;목영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.587-597
    • /
    • 2010
  • Analysis of the behavior of a laterally loaded pile is important in the design of critical civil structures. Recently, the electric strain gauge has been widely used to measure the strains along the pile. The electric strain gauge, due to lack of durability, is inappropriate in the use of long-term measurements. Herein, the feasibility of implementing the FBG sensor was investigated using a cantilever-type calibrator in laboratory. A special calibrating tool called "cantilever-calibrator" was used to calibrate the FBG sensors. The calibrator consists of a special calibration beam, a holding-clamp at one end of the beam, and a micrometer on the other end. Three FBG sensors were installed on the calibration beam. The strains measured by FBG sensors were compared with those calculated theoretically using cantilever beam theory. The calibration factor of FBG sensors were suggested to compensate the difference between measured and calculate strains.

  • PDF

기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발 (The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source)

  • 허현도;김우철;노준규;이석;이상훈;조삼주;신동오;최진호;권수일;김성훈
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.232-237
    • /
    • 2006
  • 본 연구의 목적은 Ir-192 선원의 검교정을 겉보기 방사능(apparent activity)을 이용하지 않고 물속 기준점에서 흡수선량을 측정함으로써 공기커마 세기(air-kerma strength, Sk)를 계산하고자 알고리즘을 개발하였다. 연구를 위하여 근접치료용 다목적 팬톰(multi purpose brachytherapy Phantom, MPBP)을 제작하였다. 물 흡수선량 측정은 고선량률 근접치료기(micro-Selectron, Nucletron, Netherlands)에 장착된 Ir-192 선원(Mallinckrodt Medical B.V., Netherlands)을 대상으로 측정하였다. 물 흡수선량은 몬테칼로 계산방법으로 계산된 이온전리함(TM30013, PTW, Germany)의 물 흡수선량 교정인자($N_{D.W.Q}$)를 이용하여 결정하였다. 물 흡수선량은 한 개의 선원에 대하여 4 cm에서 7 cm까지 측정하였다. 측정된 값은 전산화 치료계획 장치에서(plato BPS, ver 13.2, Nucletron, Netherlands) 계산된 값과 비교하였다. 공기커마 세기(Sk)는 기준점 5 cm되는 곳에서 3개의 Ir 선원에 대하여 구하였다. 계산된 공기커마 세기는 선원제조사에서 제공된 값과 비교하였다. 몬테칼로 계산방법으로 계산된 이온전리함의 물 흡수선량 교정인자는 5.28 cGy/nC이었다. 한 개 선원에서 측정한 물 흡수선량 값은 -2.16%에서 -0.84%까지 상대오차를 나타내었다. 공기커마 세기는 제조사에서 제공된 값과 비교하여 -0.6%에서 +1.8% 제조사 권고치 ${\pm}5%$ 이내로 잘 일치하였다. 본 연구에서 개발한 알고리즘은 기준점에서의 물 흡수선량을 정확히 결정함으로써 선원의 공기커마 세기를 구할 수 있었다. 이러한 물 흡수선량을 통한 Ir-192 선원의 검교정 방법들은 미국의학물리학회(AAPM) 보고서 TG-43에서 권고한 흡수선량 계산 알고리즘에 바로 적용할 수 있는 것으로 사료된다.

  • PDF

비교 시험에 따른 대전류 측정 센서 교정 결과 분석 (A calibration of high current measuring sensors by comparison tests)

  • 한종훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.312-313
    • /
    • 2015
  • For the traceability of high current measuring sensors of high power testing department II(HPTD II) in Korea Electrotechnology Research Institute(KERI), additional comparison tests with reference test object were performed repeatedly. The first intercomparison has been carried out between the reference shunt for Asia and high current shunt of HPTD II in 2013. This paper compares the test results of the calibration in 2014 with them in 2015. The assigned new scale factor of high current sensors will be applied to high power tests in HPTD II until the next high current intercomparison.

  • PDF

Capillary Hysteresis Model in Unsaturated Flow : State of the Art

  • Park, Chan-Kun;Sonu, Jun-Ho
    • Korean Journal of Hydrosciences
    • /
    • 제4권
    • /
    • pp.33-49
    • /
    • 1993
  • The Purpose of this study is to classify existing hysteresis models and to discuss a possibility of a new type of the hysteresis model. The existing hysteresis models are classified into three types: the interpolation model, the scaling model and the domain model, of which only domain model is to simulate hysteresis curves based on the theoretical approach, It is useful to develop a hysteresis model that requires only one branch of hysteresis curves for the model calibration because obtaining hysteresis curves by experiments is expensive and time-concept by many investigators, however their models are not successful to accurately simulate real data of Rubicon Sandy Loam and Dune Sand. There is a possibility that a new model is based on the dependent domain concept considering the weighting factor, $P_a$($\theta$), which accounts for the pore blockage effect against air entry. Conclusively, a new model where the weighting factor $P_a$($\theta$) in Model III-1 (Mualem, 1984) reduces to a known variable through an appropriate method is an alternative model which required only one branch of main curves for the model calibration.

  • PDF

A Methodology for Fatigue Reliability Assessment Considering Stress Range Distribution Truncation

  • Park, Jun Yong;Park, Yeun Chul;Kim, Ho-Kyung
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1242-1251
    • /
    • 2018
  • Not all loads contribute to fatigue crack propagation in the welded detail of steel bridges when they are subjected to variable amplitude loading. For fatigue assessment, therefore, non-contributing stress cycles should be truncated. However, stress range truncation is not considered during typical fatigue reliability assessment. When applying the first order reliability method, stress range truncation occurs mismatch between the expected number of cycles to failure and the number of cycles obtained at the time of evaluation, because the expected number of cycles only counts the stress cycles that contribute to fatigue crack growth. Herein, we introduce a calibration factor to coordinate the expected number of cycles to failure to the equivalent value which includes both contributing and non-contributing stress cycles. The effectiveness of stress range truncation and the proposed calibration factor was validated via case studies.

Development of robust Calibration for Determination Apple Sweetness using Near Infrared Spectroscopy

  • Sohn, Mi-Ryeong;Kwon, Young-Kil;Cho, Rae-Kwang
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1614-1614
    • /
    • 2001
  • The sweetness (。Bix) of fruit is the main quality factor contributing to the fruit taste. The brix of the apple fruit can be measured non-destructively by near infrared (NIR) spectroscopy, allowing the sweetness grading of individual apple fruit. However, the fruit quality is influenced by various factors such as growing location, producing year, variety and harvest time etc., accordingly the robust NIR calibration is required. In this experimental results are presented the influence of two variations such as growing location and producing year of apple fruit in establishing of calibrations for sweetness, and developed a stable and highly accurate calibration. Apple fruit (Fuji) was collected every year from 1995 to 1997 in 3 different growing locations (Andong, Youngchun and Chungsong) of Kyungpook in Korea. NIR reflectance spectra of apple fruit were scanned in wavelength range of 1100∼2500nm using an InfraAlyzer 500C (Bran+Luebbe) with halogen lamp and PbS detector. The multiple linear regression and stepwise was carried out between the NIR raw spectra and the brix measured by refractometer to select the best regression equations. The calibration models by each growing district were well predicted to dependent sample set, but poorly predicted to independent sample set. Combined calibration model using data of three growing districts predicted reasonable well to a population set drawn from all growing districts(SEP = 0.69%, Bias=-0.075). The calibration models by each harvest year were not transferable across harvest year, however a combined calibration model using data of three harvest years was sufficiently robust to predict each sample sets(SEP = 0.53%, Bias = 0.004).

  • PDF

Uncertainty Assessment: Relative versus Absolute Point Dose Measurement for Patient Specific Quality Assurance in EBRT

  • Mahmood, Talat;Ibrahim, Mounir;Aqeel, Muhammad
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.111-121
    • /
    • 2017
  • Verification of dose distribution is an essential part of ensuring the treatment planning system's (TPS) calculated dose will achieve the desired outcome in radiation therapy. Each measurement have uncertainty associated with it. It is desirable to reduce the measurement uncertainty. A best approach is to reduce the uncertainty associated with each step of the process to keep the total uncertainty under acceptable limits. Point dose patient specific quality assurance (QA) is recommended by American Association of Medical Physicists (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) for all the complex radiation therapy treatment techniques. Relative and absolute point dose measurement methods are used to verify the TPS computed dose. Relative and absolute point dose measurement techniques have a number of steps to measure the point dose which includes chamber cross calibration, electrometer reading, chamber calibration coefficient, beam quality correction factor, reference conditions, influences quantities, machine stability, nominal calibration factor (for relative method) and absolute dose calibration of machine. Keeping these parameters in mind, the estimated relative percentage uncertainty associated with the absolute point dose measurement is 2.1% (k=1). On the other hand, the relative percentage uncertainty associated with the relative point dose verification method is estimated to 1.0% (k=1). To compare both point dose measurement methods, 13 head and neck (H&N) IMRT patients were selected. A point dose for each patient was measured with both methods. The average percentage difference between TPS computed dose and measured absolute relative point dose was 1.4% and 1% respectively. The results of this comparative study show that while choosing the relative or absolute point dose measurement technique, both techniques can produce similar results for H&N IMRT treatment plans. There is no statistically significant difference between both point dose verification methods based upon the t-test for comparing two means.

An RSS-Based Localization Scheme Using Direction Calibration and Reliability Factor Information for Wireless Sensor Networks

  • Tran-Xuan, Cong;Koo, In-Soo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제4권1호
    • /
    • pp.45-61
    • /
    • 2010
  • In the communication channel, the received signal is affected by many factors that can cause errors. These effects mean that received signal strength (RSS) based methods incur more errors in measuring distance and consequently result in low precision in the location detection process. As one of the approaches to overcome these problems, we propose using direction calibration to improve the performance of the RSS-based method for distance measurement, and sequentially a weighted least squares (WLS) method using reliability factors in conjunction with a conventional RSS weighting matrix is proposed to solve an over-determined localization process. The proposed scheme focuses on the features of the RSS method to improve the performance, and these effects are proved by the simulation results.

모형의 복잡성, 구조 및 목적함수가 모형 검정에 미치는 영향 (Effects of Model Complexity, Structure and Objective Function on Calibration Process)

  • Choi, Kyung Sook
    • 한국농공학회지
    • /
    • 제45권4호
    • /
    • pp.89-97
    • /
    • 2003
  • Using inference models developed for estimation of the parameters necessary to implement the Runoff Block of the Stormwater Management Model (SWMM), a number of alternative inference scenarios were developed to assess the influence of inference model complexity and structure on the calibration of the catchment modelling system. These inference models varied from the assumption of a spatially invariant value (catchment average) to spatially variable with each subcatchment having its own unique values. Fur-thermore, the influence of different measures of deviation between the recorded information and simulation predictions were considered. The results of these investigations indicate that the model performance is more influenced by model structure than complexity, and control parameter values are very much dependent on objective function selected as this factor was the most influential for both the initial estimates and the final results.