• Title/Summary/Keyword: Calibration Factor

Search Result 436, Processing Time 0.022 seconds

A study of analytical method for volatile fatty acids (VFA) by cryogenic trapping-thermal desorption (CT-TD) technique (저온농축열탈착 시스템을 연계한 유기지방산의 분석법 평가 및 검토)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Im, Moon-Soon;Ju, Do-Weon
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.200-211
    • /
    • 2011
  • In this study, 13 compounds including four volatile fatty acids (VFA) and nine volatile organic compounds (VOC) were analyzed by cryogenic trapping-thermal desorption technique. In order to evaluate the analytical method for VFA, calibration experiments were performed using five different sorbent materials. When the calibration results are compared between different sorbents, sampling tube filled with Carbopack X showed the highest response factor (RF) for both VFA and VOC. To validate this new analytical method for VFA using cryogenic trapping-thermal desorption technique, this method was compared with alkali absorption method recommended by the odor prevention law of the Korea Ministry of Environment (KMOE). For this purpose, unknown samples were analyzed by two different methods, i.e., cryogenic trapping-thermal desorption (TD) and alkali absorption with solid phase microextraction (SPME). When the results of two different methods were compared, ratios of concentrations determined by the two analytical methods (TD/SPME) was found as 0.46 (valeric acid) ~ 0.71 (isovaleric acid). Therefore, additional study is required to properly establish and find stable analytical conditions for VFA analysis. Furthermore, comparison between two different methods should be made with more reliable calibration approaches.

Development of Environmentally Friendly Water-Soluble Lubricant for Cold Forging (냉간단조용 친환경 수용성 윤활제의 개발)

  • Lee, I.S.;Kang, J.H.;Kim, Y.R.;Je, J.S.;Ko, D.C.;Kim, B.M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.195-198
    • /
    • 2006
  • Zinc phosphate coating is required in nearly all steel cold forging operations. However, the chemical byproducts of this lubricant system are difficult to dispose of and have a negative environmental impact. In order to replace zinc phosphate based lubricants partially or completely, candidate lubricant has been developed in this study. The performance evaluation of these lubricants was conducted using the double cup extrusion test and spike forging test. With the use of the commercial FEM code DEFORM, friction factor calibration curves, i.e. cup height ratio vs. punch stroke and spike height vs. punch stroke, were established for different friction factor values. By matching the cup height ratio and the punch stroke and spike height vs. punch stroke from experiment to that obtained from FE simulations, the friction factor of the lubricants was determined. Three water-soluble lubricants; namely, Mec Homat, Royalcoat, and the developed lubricant were found to perform comparable to or better than zinc phosphate.

  • PDF

Feasibility Analysis of the Bridge Analytical Model Calibration with the Response Correction Factor Obtained from the Pseudo-Static Load Test (의사정적재하시험 응답보정계수에 의한 교량 해석모델 보정의 타당성 분석)

  • Han, Man-Seok;Shin, Soo-Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.50-59
    • /
    • 2021
  • Currently, the response correction factor is calculated by comparing the response measured by the load test on a bridge with the response analyzed in the initial analytical model. Then the load rating and the load carrying capacity are evaluated. However, the response correction factor gives a value that fluctuates depending on the measurement location and load condition. In particular, when the initial analytical model is not suitable for representing the behavior of a bridge, the range of variation is large and the analysis response by the calibrated model may give a result that is different from the measured response. In this study, a pseudo-static load test was applied to obtain static response with dynamic components removed under various load conditions of a vehicle moving at a low speed. Static response was measured on two similar PSC-I girder bridges, and the response correction factors for displacement and strain were calculated for each of the two bridges. When the initial analysis model was not properly set up, it is verified that the response of the analytical model corrected by the average response correction factor does not fall within the margin of error with the measured response.

Partial Safety Factor of Offshore Wind Turbine Pile Foundation in West-South Mainland Sea (서남해안 해상풍력단지 말뚝기초의 부분안전계수)

  • Yoon, Gil Lim;Kim, Sun Bin;Kwon, O Soon;Yoo, Moo Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1489-1504
    • /
    • 2014
  • This paper is aimed to suggest a site specific partial safety factor of offshore wind turbine (OWT) pile foundation design for the offshore wind turbine complex at a West-South mainland sea in Korea. International offshore wind design standards such as IEC, GL, DNV, API, ISO and EUROCODE were compared with each partial safety factor and resistance factor. Soil uncertainty analysis using a large number of soil data sampled was carried out, and their results were adapted to estimate partial safety factor of OWT pile foundation through reliability analyses. The representative partial safety factor has been estimated as 1.3. When a proposed partial factor is willing to use to other sites, it is recommended that further studies on code calibration are required to validate their accuracy using more site characterization data.

Development of Geometric Calibration Method for Triple Head Pinhole SPECT System (삼중헤드 SPECT에서 기하학적 보정 기법의 개발)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Lee, Won-Woo;Park, So-Yeon;Son, Ji-Yeon;Kim, Yu-Kyeong;Kim, Sang-Eun;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Purpose: Micro-pinhole SPECT system with conventional multiple-head gamma cameras has the advantage of high magnification factor for imaging of rodents. However, several geometric factors should be calibrated to obtain the SPECT image with good image quality. We developed a simplified geometric calibration method for rotating triple-head pinhole SPECT system and assessed the effects of the calibration using several phantom and rodent imaging studies. Materials and Methods: Trionix Triad XLT9 triple-head SPECT scanner with 1.0 mm pinhole apertures were used for the experiments. Approximately centered point source was scanned to track the angle-dependent positioning errors. The centroid of point source was determined by the center of mass calculation. Axially departed two point sources were scanned to calibrate radius of rotation from pinhole to center of rotation. To verify the improvements by the geometric calibration, we compared the spatial resolution of the reconstructed image of Tc-99m point source with and without the calibration. SPECT image of micro performance phantom with hot rod inserts was acquired and several animal imaging studies were performed. Results: Exact sphere shape of the point source was obtained by applying the calibration and axial resolution was improved. Lesion detectibility and image quality was also much improved by the calibration in the phantom and animal studies. Conclusion: Serious degradation of micro-pinhole SPECT images due to the geometric errors could be corrected using a simplified calibration method using only one or two point sources.

Determination of Seed Protein and Oil Concentration in Kiddny Bean by Near Infrared Spectroscopic Analysis (근적외 분광분석법을 이용한 강낭콩 종실단백질 및 지방의 비파괴 분석)

  • 이한범;최병렬;강창성;김영호;최영진
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.3
    • /
    • pp.248-252
    • /
    • 2001
  • Near infrared spectroscopy (NIRS) is a rapid and accurate analytical method for determining the composition of agricultural products and feeds. An important merit of the NIRS analytical system is consistent predictions across instruments. However, proper calibration is the most important factor for a NIRS analytical system. Forty samples were obtained from Kyonggi-do Agricultural Research and Extension Services, and used to develop calibrations for crude protein content and crude oil content. Calibrations equations were developed using multiple linear regression (MLR). Accuracy and precision of NIRS predictions were adequate for quality measurement for the two constituents in kidney bean seed. In calibration sample sets (N=30), multiple correlation coefficient between NIR and lab measurements is 0.90 for seed, 0.97 for powder in seed protein concentration and 0.40 for seed and 0.92 for powder in seed oil concentration, respectively. It is concluded that NIRS method is suitable for the determination of seed composition in whole kidney bean.

  • PDF

Discrimination and Quantitative Analysis of Watercore in Apple Fruit by Near Infrared Transmittance Spectroscopy

  • Kim, Eun-Ok;Sohn, Mi-Ryeong;Kwon, Young-Kil;Lin, Gou-Lin;Cho, Rae-Kwang
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1529-1529
    • /
    • 2001
  • The watercore in apple is very important factor in storage and sorting of fruit. Most consumers tend to prefer the apple included watercore in immediately after harvest, however the watercore causes fruit flesh to brown during storage and lose the worth after all. But it is practically impossible to judge to the naked eye whether an apple has watercore or not. Therefore, the rapid, accurate and non-destructive analysis method for discrimination of watercore should be settled without delay. In this study we attempted the discrimination and quantitative analysis of watercore in apple fruit using near-infrared transmittance spectroscopy ‘Fuji’ apple fruits produced in Kyungpook of Korea was used in this experiment. The watercore content in apple was evaluated by graphic treatment of culled slice sections(10 mm). NIR transmittance spectra were collected over the 500 to 1000 nm spectral region with a spectrometer (Sentronic Co., Germany). The calibration models were carried out by partial least squares (PLS) analysis between NIR spectra data of apples and chemical data of watercore content. The spectra were different in absorbance between apple included watercore and not included one. Apple included watercore had higher absorption band than sample not included one at 732 and 820 nm. The calibration model seems to be accurate to predict the watercore content in apple fruit, the correlation coefficient (R) and root mean square error of prediction (RMSEP) were 0.99 and 0.93%, respectively. This result indicates that the PLSR calibration model by using NIR transmittance spectroscopy could be used for discrimination of watercore in apple fruit.

  • PDF

A Study on the Transducer Calibration for Acoustic Emission Measurement (AE 측정을 위한 탐촉자의 보정에 대한 고찰)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.53-58
    • /
    • 1996
  • In order to investigate the source mechanism of micro cracks through acoustic emission measurement induced by rock fracture, careful calibration of the entire linkage of the detecting system, from the transducers to transient recorder, is an essential requirement prior to testing. Transducers and digitiging system are generally the weakest links in the measurement system because they must translate mechanical motions into digital electric signals. In this study, PAC piezoelectric pressure transducers are calibrated with a standard NBS conical shaped displacement transducer and a DG piezoelectric displacement transducer. The NBS and PAC transducers are insensitive to changes in horizontal impingement angle but sensitive to changes in incident angle. The ray path along the logitudinal axis of the tranducer produced a maximum response while the ray path perpendicular to the transducer axis gave a minimum. And a difference in individual transducers factor for a peak-to-peak amplitude of PAC transducers was within 40%. An average PAC transducer coefficient was determined as 77mv/pm by an absolute calibration test using NBS transducer.

  • PDF

Calibration and Estimation of Parameter for Storage Function Model (저류함수모형의 매개변수 보정 및 추정)

  • Kim, Bum Jun;Kawk, Jae Won;Lee, Jin Hee;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1B
    • /
    • pp.21-32
    • /
    • 2008
  • Flood forecasting is a very important tool as one of nonstructural measures for reduction of flood damages in life and property and its accuracy is also an important factor. However, when we apply the Storage Function Model(SFM) which is mainly used for the flood forecasting system in Korea, the determination of the parameters is very important but it is difficult. So, the parameters have been calibrated by using an empirical formulas and judgement of hydrologist. Hence, in this study we perform the sensitivity analysis to understand the parameter characteristics and establish the ranges of parameters of the SFM. Also we do the parameter calibration by using the optimization techniques and objective functions, and evaluate their performances. Especially, we suggest a method to determine proper parameters by using a objective function which can be obtained from flood events. So, we use the suggested method for parameter estimation and compare the estimated parameters with the previously reported parameters. As a result of the application, the estimated parameters by the suggested method showed better than them from the previously reported parameters.

The Measurement of Soot Particle Temperatures Using a Ratio Pyrometry (Ratio Pyrometry를 이용한 매연입자 온도 계측에 대한 고찰)

  • Nam, Youn-Woo;Lee, Won-Nam;Lee, Chun-Beom
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.124-129
    • /
    • 2004
  • The ratio pyrometry has been investigated experimentally for the measurement of soot particle temperatures in a diffusion flame. A tungsten lamp calibration system was constructed and used in order to calibrate the ratio pyrometry and two-color pyrometry using a KL-factor method. Once the ratio pyrometry is properly calibrated, temperatures measured using a ratio pyrometry were virtually identical to those obtained from a KL-factor method. The effect of soot volume fraction on temperature measurement was almost negligible, and therefore, the ratio pyrometry could provide the useful temperature information of sooting flames. The potential application of a ratio pyrometry to a 2-D temperature measurement without sacrificing the accuracy was demonstrated.

  • PDF