• Title/Summary/Keyword: Calibration Factor(K-factor)

Search Result 279, Processing Time 0.028 seconds

Development of high performance liquid chromatography assay method of diosmin capsules (디오스민 캡슐의 HPLC 분석법의 개발)

  • Shim, Dae Hyun;Shin, Dong Han;Truong, Quoc Ky;Mai, Xuan Lan;Kang, Jong-Seong;Woo, Mi Hee;Na, Dong-Hee;Chun, In-Koo;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.277-282
    • /
    • 2016
  • British Pharmacopoeia (BP 2013), the United States Pharmacopoeia (USP 39) and the Korean Pharmacopoeia (KP XI) contain monographs for the quality control of raw diosmin using high performance liquid chromatography (HPLC). However, official monographs detailing pharmaceutical formulations for diosmin are not available in foreign pharmacopoeias. In the KP XI, ultraviolet-visible (UV-Vis) spectroscopy-which is less specific than HPLC-is reported for the testing of diosmin capsules. In this study, we present an alternative HPLC assay for such testing that is more specific than UV-Vis methods. Method validation was performed to determine linearity, precision, accuracy, system suitability, and robustness. The linearity of calibration curves in the desired concentration range was high ($r^2$>0.999), while the RSDs for intra- and inter-day precision were 0.15-0.29 % and 1.05-1.74%, respectively. Accuracies ranged from 101.2-103.2 %, while the retention time and peak area RSDs were 0.37 % and 0.06 %, respectively. Additionally, the plate number and asymmetry factor values for diosmin were 3591.293 and 1.35, respectively. Since the intermediate-precision and robustness of the assay were satisfactory, this method will be a valuable addition to the Korean Pharmacopoeia (KP XI).

Inter-hospital Comparison of Cesarean Section Rates after Risk Adjustment (위험도 보정을 통한 병원간 제왕절개 분만율의 비교)

  • Lee, Sang-Il;Ha, Beom-Man;Lee, Moo-Song;Kang, Wee-Chang;Koo, Hee-Jo;Kim, Chang-Yup;Khang, Young-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.4
    • /
    • pp.337-346
    • /
    • 2001
  • Objective : To determine the clinical risk factors associated with the mode of delivery decision and to compare cesarean section rates after adjusting for risk factors identified among Korean hospitals. Methods Data were collected from 9 general hospitals in two provincial regions by medical record abstraction during February 2000. A total of 3,467 cases were enrolled and analyzed by stepwise logistic regression. Performance of the risk-adjustment model (discrimination and calibration) was evaluated by the C statistic and the Hosmer-Lemeshow test. Crude rates, predicted rates with 95% confidence intervals, and adjusted rates of cesarean section were calculated and compared among the hospitals. Results : The average crude cesarean section rate was 53.2%, ranging from 39.4% to 65.7%. Several risk factors such as maternal age, previous history of cesarean section, placenta previa, placental abruption, malpresentation, amniotic fluid abnormality, gestational anemia, infant body weight, pregnancy-induced hypertension, and chorioamnionitis were found to have statistically significant effects on the mode of delivery. It was confirmed that information about most of these risk factors was able to be collected through the national health insurance claims database in Korea. Performance of the risk-adjustment model was good (c statistic=0.815, Hosmer-Lemeshow test=0.0621). Risk factor adjustment did lead to some change in the rank of hospital cesarean section rates. The crude rates of three hospitals were beyond 95% confidence intervals of the predicted rates. Conclusions : Considering that cesarean section rates in Korean hospitals are too high, it is apparent that some policy interventions need to be introduced. The concept and methodology of risk adjustment should be used in the process of health policy development to lower the cesarean section rate in Korea.

  • PDF

Patient-Specific Quality Assurance in a Multileaf Collimator-Based CyberKnife System Using the Planar Ion Chamber Array

  • Yoon, Jeongmin;Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.59-65
    • /
    • 2018
  • This paper describes the clinical use of the dose verification of multileaf collimator (MLC)-based CyberKnife plans by combining the Octavius 1000SRS detector and water-equivalent RW3 slab phantom. The slab phantom consists of 14 plates, each with a thickness of 10 mm. One plate was modified to support tracking by inserting 14 custom-made fiducials on surface holes positioned at the outer region of $10{\times}10cm^2$. The fiducial-inserted plate was placed on the 1000SRS detector and three plates were additionally stacked up to build the reference depth. Below the detector, 10 plates were placed to avoid longer delivery times caused by proximity detection program alerts. The cross-calibration factor prior to phantom delivery was obtained by performing with 200 monitor units (MU) on the field size of $95{\times}92.5mm^2$. After irradiation, the measured dose distribution of the coronal plane was compared with the dose distribution calculated by the MultiPlan treatment planning system. The results were assessed by comparing the absolute dose at the center point of 1000SRS and the 3-D Gamma (${\gamma}$) index using 220 patient-specific quality assurance (QA). The discrepancy between measured and calculated doses at the center point of 1000SRS detector ranged from -3.9% to 8.2%. In the dosimetric comparison using 3-D ${\gamma}$-function (3%/3 mm criteria), the mean passing rates with ${\gamma}$-parameter ${\leq}1$ were $97.4%{\pm}2.4%$. The combination of the 1000SRS detector and RW3 slab phantom can be utilized for dosimetry validation of patient-specific QA in the CyberKnife MLC system, which made it possible to measure absolute dose distributions regardless of tracking mode.

NEAR-INFRARED STUDIES ON STRUCTURE-PROPERTIES RELATIONSHIP IN HIGH DENSITY AND LOW DENSITY POLYETHYLENE

  • Sato, Harumi;Simoyama, Masahiko;Kamiya, Taeko;Amari, Trou;Sasic, Slobodan;Ninomiya, Toshio;Siesler, Heinz-W.;Ozaki, Yukihiro
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1281-1281
    • /
    • 2001
  • Near-infrared (NIR) spectra have bean measured for high-density (HDPE), linear low-density (LLDPE), and low-density (LDPE) polyethylene in pellet or thin films. The obtained spectra have been analyzed by conventional spectroscopic analysis methods and chemometrics. By using the second derivative, principal component analysis (PCA), and two-dimensional (2D) correlation analysis, we could separate many overlapped bands in the NIR. It was found that the intensities of some bands are sensitive to density and crystallinity of PE. This may be the first time that such bands in the NIR region have ever been discussed. Correlations of such marker bands among the NIR spectra have also been investigated. This sort of investigation is very important not only for further understanding of vibration spectra of various of PE but also for quality control of PE by vibrational spectroscopy. Figure 1 (a) and (b) shows a NIR reflectance spectrum of one of the LLDPE samples and that of PE, respectively. Figure 2 shows a PC weight loadings plot of factor 1 for a score plot of PCA for the 16 kinds of LLDPE and PE based upon their 51 NIR spectra in the 1100-1900 nm region. The PC loadings plot separates the bands due to the $CH_3$ groups and those arising form the $CH_2$ groups, allowing one to make band assignments. The 2D correlation analysis is also powerful in band enhancement, and the band assignments based upon PCA are in good agreement with those by the 2D correlation analysis.(Figure omitted). We have made a calibration model, which predicts the density of LLDPE by use of partial least square (PLS) regression. From the loadings plot of regression coefficients for the model , we suggest that the band at 1542, 1728, and 1764 nm very sensitive to the changes in density and crystalinity.

  • PDF

Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application (의료용 방사성폐기물 자체처분을 위한 방사능 측정 및 평가)

  • Kim, Changbum;Park, MinSeok;Kim, Gi-Sub;Jung, Haijo;Jang, Seongjoo
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • The amounts of radioactive wastes to be disposed in the medical institute have been increased due to development of radiation diagnosis and therapy rapidly. They are produced mostly by the very short lived radioisotopes such as $^{18}F$ used in PET/CT, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}Tl$, etc. IAEA proposed a criteria for the clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). Radioactive wastes of $^{18}F$, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}TI$ in the several types of container like Marinelli beaker, vial and plastic, were collected to measure the concentration of the waste of each nuclide in accordance with IAEA criteria. The measurement method and procedure of determining specific activity of the wastes using gamma emitters like MCA, gamma counter and beta emitters were developed. For the efficiency calibration of the detectors, CRM (certified reference material) which has the same dimension and shape was provided by Korea Research Institute of Standards and Science (KRISS). Correction factor of the radioactivity decay was calculated based on the measurement results, and the consideration of mutual relation with theoretical equation. The result of this study will be proposed as ISO standard.

Discussion of Soil Respiration for Understanding Ecosystem Carbon Cycle in Korea (생태계 탄소순환 이해를 위한 국내 토양호흡 연구의 고찰)

  • Lee, Jae-Ho;Yi, Jun-Seok;Chun, Young-Moon;Chae, Nam-Yi;Lee, Jae-Seok
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.2
    • /
    • pp.310-318
    • /
    • 2013
  • In territorial ecosystem, soil has stored considerable amount of carbon, and it is vulnerable to weakness release much of the carbon to atmosphere. In this study, we have been effort realization and discussion to the error between inter-instruments and measurement methods, time and special variations, gap filling and separation from each source included in soil respiration, used to collect soil respiration data in various ecosystems in Korea. In conclusion, it have to collect calibration data throughout comparison test between methods and instruments because accumulated data from past and accumulating data in present did not calibrated. In predicting change of soil carbon dynamic using the model method, it needs important data such as longterm and short-term data, artificial handling data of major factor, data from various ecosystem, soil texture, soil depth etc. In company with, we should collect highly qualified data through deep consideration of present problems.

Determination of Nitrovin in Fishery Products by Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 니트로빈의 정량분석법 개발 및 검증)

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.118-123
    • /
    • 2018
  • The objective of this study was to develop a sensitive method for the identification and determination of nitrovin in fishery products by using a solid-phase extraction (SPE), as performed with a liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted with a mixture of acetonitrile and water, and were then defatted with acetonitrile saturated hexane, after which further clean-up was accomplished with SPE on the hydrophilic-lipophilic balance (HLB) cartridges. The analytes were subsequently ionized in the positive mode of an electrospray ionization (ESI), and where thereby detected in a process of multiple reaction monitoring (MRM). The linearity (expressed as correlation coefficients) of the matrix calibration curves was > 0.985. The limit of the quantification for the nitrovin was measured at 0.001 mg/kg. The accuracy (expressed as average recovery) was noted between 72.1 and 122%. The precision (expressed as coefficient variation) was noted from 2.9 to 16.9%. According to the CODEX CAC/GL-71 guideline accuracy, precision, linearity, and limit of detection were determined in three matrices (which were flatfish, eel and shrimp). The proposed method was suitable for analyzing the associated nitrovin residues. This application and result can also be a factor to contribute to the non-detection drugs management in fishery products.

Establishing a Nomogram for Stage IA-IIB Cervical Cancer Patients after Complete Resection

  • Zhou, Hang;Li, Xiong;Zhang, Yuan;Jia, Yao;Hu, Ting;Yang, Ru;Huang, Ke-Cheng;Chen, Zhi-Lan;Wang, Shao-Shuai;Tang, Fang-Xu;Zhou, Jin;Chen, Yi-Le;Wu, Li;Han, Xiao-Bing;Lin, Zhong-Qiu;Lu, Xiao-Mei;Xing, Hui;Qu, Peng-Peng;Cai, Hong-Bing;Song, Xiao-Jie;Tian, Xiao-Yu;Zhang, Qing-Hua;Shen, Jian;Liu, Dan;Wang, Ze-Hua;Xu, Hong-Bing;Wang, Chang-Yu;Xi, Ling;Deng, Dong-Rui;Wang, Hui;Lv, Wei-Guo;Shen, Keng;Wang, Shi-Xuan;Xie, Xing;Cheng, Xiao-Dong;Ma, Ding;Li, Shuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3773-3777
    • /
    • 2015
  • Background: This study aimed to establish a nomogram by combining clinicopathologic factors with overall survival of stage IA-IIB cervical cancer patients after complete resection with pelvic lymphadenectomy. Materials and Methods: This nomogram was based on a retrospective study on 1,563 stage IA-IIB cervical cancer patients who underwent complete resection and lymphadenectomy from 2002 to 2008. The nomogram was constructed based on multivariate analysis using Cox proportional hazard regression. The accuracy and discriminative ability of the nomogram were measured by concordance index (C-index) and calibration curve. Results: Multivariate analysis identified lymph node metastasis (LNM), lymph-vascular space invasion (LVSI), stromal invasion, parametrial invasion, tumor diameter and histology as independent prognostic factors associated with cervical cancer survival. These factors were selected for construction of the nomogram. The C-index of the nomogram was 0.71 (95% CI, 0.65 to 0.77), and calibration of the nomogram showed good agreement between the 5-year predicted survival and the actual observation. Conclusions: We developed a nomogram predicting 5-year overall survival of surgically treated stage IA-IIB cervical cancer patients. More comprehensive information that is provided by this nomogram could provide further insight into personalized therapy selection.

Comparison of ISO-GUM and Monte Carlo Method for Evaluation of Measurement Uncertainty (몬테카를로 방법과 ISO-GUM 방법의 불확도 평가 결과 비교)

  • Ha, Young-Cheol;Her, Jae-Young;Lee, Seung-Jun;Lee, Kang-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.647-656
    • /
    • 2014
  • To supplement the ISO-GUM method for the evaluation of measurement uncertainty, a simulation program using the Monte Carlo method (MCM) was developed, and the MCM and GUM methods were compared. The results are as follows: (1) Even under a non-normal probability distribution of the measurand, MCM provides an accurate coverage interval; (2) Even if a probability distribution that emerged from combining a few non-normal distributions looks as normal, there are cases in which the actual distribution is not normal and the non-normality can be determined by the probability distribution of the combined variance; and (3) If type-A standard uncertainties are involved in the evaluation of measurement uncertainty, GUM generally offers an under-valued coverage interval. However, this problem can be solved by the Bayesian evaluation of type-A standard uncertainty. In this case, the effective degree of freedom for the combined variance is not required in the evaluation of expanded uncertainty, and the appropriate coverage factor for 95% level of confidence was determined to be 1.96.

Development of an 1-Dimensional Dynamic Numerical Model for BTX Removal Process Analysis by Gaseous-Biofilm Filtration (기체상-생물막 여과 공법의 BTX 제거 공정 해석을 위한 1차원 동적 수치모델 개발)

  • Kim, Yeong-Kwan;Choi, Sung-Chan;Kim, Seog-Ku;Lee, Yong-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.12
    • /
    • pp.689-695
    • /
    • 2015
  • A biofilm filtration for the removal of gaseous pollutants has been recognized as a process with a complex interaction between the gas flow characteristics and the process operating variables. This study aims to develop an one dimensional dynamic numerical model which can be utilized as a tool for the analysis of biofilm filtration process operated in plug flow mode. Since, in a plug flow system, minor environmental changes in a gaseous unit process cause a drastic change in reaction and the interaction between the pollutants is an influencing factor, plug flow system was generalized in developing the model. For facilitation of the model development, dispersion was simplified based on the principles of material balance. Several reactions such as competition, escalation, and control between the pollutants were included in the model. The applicability of the developed model was evaluated by taking the calibration and verification steps on the experimental data performed for the removal of BTX at both low and high flow concentration. The model demonstrated a correlation coefficient ($R^2$) greater than 0.79 under all the experimental conditions except for the case of toluene at high flow condition, which suggested that this model could be used for the generalized gaseous biofilm plug flow filtration system. In addition, this model could be a useful tool in analyzing the design parameters and evaluating process efficiency of the experiments with substantial amount of complexity and diversity.