• 제목/요약/키워드: Calibration Factor(K-factor)

검색결과 279건 처리시간 0.032초

A Compensator to Advance Gyro-Free INS Precision

  • Hung Chao-Yu;Fang Chun-Min;Lee Sou-Chen
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권3호
    • /
    • pp.351-358
    • /
    • 2006
  • The proposed inertial measurement unit (IMU) is composed of accelerometers only. It can determine a vehicle's position and attitude, which is the Gyro-free INS. The Gyro-free INS error is deeply affected by the sensor bias, scale factor and misalignment. However, these parameters can be obtained in the laboratory. After these misalignments are corrected, the Gyro-free strap-down INS could be more accurate. This paper presents a compensator design for the strap-down six-accelerometer INS to correct misalignment. A calibration experiment is taken to get the error parameters. A simulation results show that it will decrease the INS error to enhance the performance after compensation.

두 점 교정법을 이용한 담배 연기 성분 중 니코틴 분석 결과에 대한 불확도 평가 (Uncertainty Evaluation of Nicotine in Cigarette Mainstream Smoke Using Two Point Re-calibration Method)

  • 김미주;지상운;황건중;이문수;조성일
    • 한국연초학회지
    • /
    • 제26권2호
    • /
    • pp.168-178
    • /
    • 2004
  • Uncertainty of final measurement results considering main uncertainty sources being in nicotine of mainstream smoke was estimated. This study was accomplished by using the ISO 'The Guide to the Expression of Uncertainty in Measurement'. Using the two point re-calibration method, uncertainty for nicotine concentration was calculated considering the uncertainty sources of each step. The concentration and uncertainty of nicotine in mainstream smoke was estimated as $153.95{\pm}17.84\;{\mu}g/mL\;(0.77\pm0.089 mg/cig)$. The expanded uncertainty was $17.84 {\mu}g/mL(\pm0.089 mg/cig).$ The reported expanded uncertainty of the measurement is stated as the standard uncertainty of measurement multiplied by a coverage factor of 2, which for a normal distribution corresponds to a coverage probability of approximately $95\%$ The former expression indicates the conversion concentration into the sample.

SgrA* 22/43GHz KaVA observation and its Amplitude Calibration

  • CHO, ILJE;JUNG, TAEHYUN;ZHAO, GUANG-YAO;KINO, MOTOKI;SOHN, BONGWON
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.73.2-73.2
    • /
    • 2016
  • We present the results of KaVA SgrA* observation together with Takahagi(32m), Yamaguchi(32m) and Nobeyama(45m) telescopes at 22 and 43GHz, respectively. In early 2014, G2 cloud was expected to encounter with SgrA* and to make a significant flux variation, but it has not been measured yet. So it's worth to check our amplitude calibration method to confirm if we have a missing flux caused by uncertainty in measuring it. We have tested both a standard method using system noise temperature(Tsys) with antenna gain information, and a template method in order to calibrate antenna gain using nearby maser source. As a result, we found that the latter method is useful for antennas which have inaccurate gain information or poor Tsys measurements, and is especially effective for sources at low elevation like SgrA*. In addition, the comparison shows that the amplitude calibration by standard method can be improved up to 10% with a correction factor using a template method. This result implies we can get more accurate flux from a standard method when any maser source not exists around target.

  • PDF

Calibrating Thresholds to Improve the Detection Accuracy of Putative Transcription Factor Binding Sites

  • Kim, Young-Jin;Ryu, Gil-Mi;Park, Chan;Kim, Kyu-Won;Oh, Berm-Seok;Kim, Young-Youl;Gu, Man-Bok
    • Genomics & Informatics
    • /
    • 제5권4호
    • /
    • pp.143-151
    • /
    • 2007
  • To understand the mechanism of transcriptional regulation, it is essential to detect promoters and regulatory elements. Various kinds of methods have been introduced to improve the prediction accuracy of regulatory elements. Since there are few experimentally validated regulatory elements, previous studies have used criteria based solely on the level of scores over background sequences. However, selecting the detection criteria for different prediction methods is not feasible. Here, we studied the calibration of thresholds to improve regulatory element prediction. We predicted a regulatory element using MATCH, which is a powerful tool for transcription factor binding site (TFBS) detection. To increase the prediction accuracy, we used a regulatory potential (RP) score measuring the similarity of patterns in alignments to those in known regulatory regions. Next, we calibrated the thresholds to find relevant scores, increasing the true positives while decreasing possible false positives. By applying various thresholds, we compared predicted regulatory elements with validated regulatory elements from the Open Regulatory Annotation (ORegAnno) database. The predicted regulators by the selected threshold were validated through enrichment analysis of muscle-specific gene sets from the Tissue-Specific Transcripts and Genes (T-STAG) database. We found 14 known muscle-specific regulators with a less than a 5% false discovery rate (FDR) in a single TFBS analysis, as well as known transcription factor combinations in our combinatorial TFBS analysis.

유역모형을 이용한 금강상류 유역의 유사이송율 산정 (Estimation of Sediment Delivery Ratio in Upper Geum River Basin Using Watershed Model)

  • 김태근;김민주
    • 환경영향평가
    • /
    • 제22권6호
    • /
    • pp.695-703
    • /
    • 2013
  • Soil erosion and sediment delivery ratio(SDR) were estimated by using HSPF model in 3 tributaries of upper stream of Geum river-basin. Meteorological data and other input data were constructed from 2006 to 2011 year by the HSPF model. Flow and suspended solid results were relatively matched with the measurement data through the calibration and validation of the model. Soil erosion was proportional to the amount of rainfall and the area of watershed based on the results of model calibration and validation. SDR in Moojunamdea stream was the highest and one in Cho stream was the lowest. This was effected by the geographical characteristic. SDR was 17.6% Moojunamdea stream, 9.1% Cho stream and 13.2 % Bocheong stream. As the SDR was effected by watershed area and shape factor in this study area.

Reliability analysis of tunnels with consideration of the earthquakes extreme events

  • Azadi, Mohammad;Ghasemi, S. Hooman;Mohammadi, Mohammadreza
    • Geomechanics and Engineering
    • /
    • 제22권5호
    • /
    • pp.433-439
    • /
    • 2020
  • Tunnels are one of the most important constructions in civil engineering. The damage to these structures caused enormous costs. Therefore, the safe and economic design of these structures has long been considered. However, both applied loads on the tunnels as well as the resistance of the structural members are naturally uncertain parameters, hence, the design of these structures requires considering the probabilistic approaches. This study aims to determine the load and resistant factors of lining tunnels concerning the earthquake extreme events limit state function. For this purpose, tunnels that have been designed according to the previous design codes (AASHTO Tunnel LRFD 2017) and using reliability analysis, the optimum reliability of these structures for different loading scenarios is determined. In this paper, the tunnel is considered circular. Finally, the proper load and resistance factors are calculated corresponding to the obtained target reliability. Based on the performed calibration earthquake extreme events limit state function, the result of this study can be recommended to AASHTO Tunnel LRFD 2017.

정밀전력계의 교정과 시험을 위한 전력표준시스템 (Power Standard System for the Calibration and Test of Precision Power Meters)

  • 박영태;유권상;유광민;장석명
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권11호
    • /
    • pp.622-627
    • /
    • 2002
  • The power comparison techniques have implemented power measurements, in which a power comparator is used to balance ac against a dc power obtained from known values. The developed power standard system using the comparison techniques consists of dc sources, ac source, control switches, resistive voltage dividers, resistive shunts and a power comparator. The total uncertainty of the power standard system was proved by analysis of the component instruments. Its expanded(k=2) uncertainty is evaluated to be less than 30 uW/VA at unit power factor and 42 uW/VA at power factor 0.5

비탄성 설계 스펙트럼에 의한 이력 모델의 효과 (Effect of Hysteretic Models on the Inelastic Design Spectra)

  • 한상환;오영훈;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.214-224
    • /
    • 1999
  • The design response spectrum has been widely used in seismic design to estimate force and deformation demands of structures imposed by Earthquake Ground Motion (EQGM). Inelastic Design Response Spectra (IDRS) to specify design yielding strength in seismic codes are obtained by reducing the ordinates of Linear Elastic Design Response Spectrum (LEDRS) by strength reduction factor (R). Since a building is designed using reduced design spectrum (IDRS) rather than LEDRS in current seismic design procedures it allows structures behave inelastically during design level EQGM. Inelastic Response Spectra (IRS) depend not only on the characteristics of the expected ground motion at a given site, but also on the dynamic properties and nonlinear characteristics of a structure. However, it has not been explicitly investigated the effect of different hysteretic models on IRS. In this study, the effect of hysteretic models on IRS is investigated.

  • PDF

물흡수선량 표준에 기반한 $^{192}Ir$ 근접치료 선원 교정 시 원통형 이온함의 이온함 간 변화 (Chamber to Chamber Variations of a Cylindrical Ionization Chamber for the Calibration of an $^{192}Ir$ Brachytherapy Source Based on an Absorbed Dose to Water Standards)

  • 김성훈;허현도;최상현;김찬형;민철희;신동오;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.7-13
    • /
    • 2009
  • 본 논문은 물 흡수선량 표준에 기반하여 근접치료 선원인 $^{192}Ir$을 교정하는 것에 대한 예비적 연구를 위한 것이다. 이온함을 사용하여 물흡수선량 표준에 기반하여 근접치료 선원을 교정하기 위해선, 빔 선질 교정인자인 $k_{Q,Q_0}$가 필요하다. 본 연구에선 일차 표준을 사용하여 지정된 거리에서의 흡수선량를 측정하는 데 있어서의 현실적인 어려움 때문에 몬테칼로 전산모사와 반실험적인 방법을 통하여 $k_{Q,Q_0}$를 결정하였다. 본 연구를 위해 PTW30013 이온함 5개를 선택하였다. 포괄적 $k^{gen}_{Q,Q_0}$ 값의 경우엔 이온함간 변화가 최대 4.0%에 이른 반면, 개별적 $k^{ind}_{Q,Q_0}$ 경우엔 이온함간 변화가 최대 0.5% 이내였다. 이 결과는 물 흡수선량에 기반하여 근접치료 선원인 $^{192}Ir$을 교정시에 이온함을 왜 개별적으로 교정해야 하는지, 개별적인 교정이 얼마나 중요한 지를 보여 준다. 가까운 장래에 공기커마 세기 대신에 사용자가 근접치료 선원을 고에너지 광자빔과 전자빔의 교정에서처럼 치료에서 관심있는 물리량인 물흡수선량의 관점에서 교정할 수 있기를 희망한다.

  • PDF

A 1.2 V 7-bit 1 GS/s CMOS Flash ADC with Cascaded Voting and Offset Calibration

  • Jang, Young-Chan;Bae, Jun-Hyun;Lee, Ho-Young;You, Yong-Sang;Kim, Jae-Whui;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권4호
    • /
    • pp.318-325
    • /
    • 2008
  • A 1.2 V 7-bit 1 GS/s CMOS flash ADC with an interpolation factor of 4 is implemented by using a $0.13\;{\mu}m$ CMOS process. A digital calibration of DC reference voltage is proposed for the $1^{st}$ preamp array to compensate for the input offset voltage of differrential amplifiers without disturbing the high-speed signal path. A 3-stage cascaded voting process is used in the digital encoder block to eliminate the conescutive bubbles up to seven completely, if the $2^{nd}$ preamp output is assumed to have a single bubble at most. ENOB and the power consumption were measured to be 5.88 bits and 212 mW with a 195 MHz $400\;mV_{p-p}$ sine wave input.