• 제목/요약/키워드: Cable type

검색결과 513건 처리시간 0.032초

케이블 니팅의 표현 유형에 관한 연구 (A Study on the Expression Types of Cable Knitting)

  • 김성달
    • 패션비즈니스
    • /
    • 제22권5호
    • /
    • pp.41-51
    • /
    • 2018
  • Cable knitting, one of the most representative structures of knitwear has been applied to a number of knit items in a variety of expressions every season. The purpose of this study is to analyze the various types of expressions applied with cable knitting techniques to make the necessary data for planning cable knit designs. The types of cable knitting were devide into two categories which are based on the cable knitting pattern and structure. Based on the pattern, firstly, formal type is a reproduction of traditional Aran knit style and is usually applied to a practical and comfortable timeless knit product. Secondly, informal type is irregular applied to patterns and directions to highlight the dynamics of cable patterns. Thirdly, contrasting type emphasizes the cable pattern by contrasting the color of the part of the cable pattern. Fourthly, figurative type is the expression of the conceptual motifs and using the cable knit pattern itself as motif. Based on the structure, firstly, open type is to emphasize patterns and spaces by utilizing open spaces created by the intersection of cabling stitches. Secondly, decorative type is to enhance the ornamental effect of cable knitting by various methods and other subsidiary materials. Thirdly, avant-garde type is applied in various ways with exaggerated volumes or textures using the three-dimensional effects of cable knitting. Through this study, we look forward to the possibility of expressing the unique aesthetic characteristics of each of the various knitting techniques.

HVDC 500kV PPLP MI 케이블시스템 개발 (Development of HVDC 500kV PPLP MI cable systems in Korea)

  • 이수봉;조동식;김성윤;이태호;이수길;전승익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1202-1203
    • /
    • 2015
  • This paper describes the development of HVDC ${\pm}500kV$ polypropylene laminated paper (PPLP) mass-impregnated (MI) type cable system for HVDC transmission lines. As you know, mass-impregnated type cable generally has only insulating layer with the Kraft paper impregnated with a high-viscosity insulating compound. But polypropylene laminated paper is made of a layer of extruded polypropylene (PP) film sandwiched between two layers of Kraft paper. Thanks to PP film and its combination with Kraft paper, PPLP has higher AC, Impulse (Imp.) and DC breakdown (BD) strengths as well as lower dielectric loss than conventional Kraft paper insulation. In addition, Kraft MI cable has a limitation for the maximum conductor temperature as $55^{\circ}C$ But this PPLP MI cable has higher maximum conductor temperature than that of Kraft MI cable due to advantage of oil drainage characteristics. It is the most economic type of cable for HVDC transmission. Also HVDC ${\pm}500kV$ PPLP MI cable system was developed including land joints and outdoor-terminations. In order to prove the mechanical and electrical performances, the type test was carried out according to CIGRE recommendations. A full scale cable system has been tested successfully. And additional load cycle and polarity reversal tests on the cable system showed a higher performance compared with a similar mass impregnated paper cable.

  • PDF

해저케이블 매설심도 측정오차 저감 방법에 관한 연구 (A Study on the Method to Minimize Measuring Burial Depth Error for Submarine Cable)

  • 안용호;김용학;한정열;이유진;한병성
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.329-334
    • /
    • 2012
  • The distribution submarine cables are normally used for power supply at island, which are mostly installed in the southern coast of KOREA, and partially installed in the west coast and Jeju-Island. There are two way of submarine cable burying system, buried and unburied type. Since 2003, KEPCO is entirely being constructing the distribution submarine cable by buried type. In this case, 'burial depth' is key index for evaluating the suitability of the buried situation. Therefore, the measurement accuracy of 'burial depth' is a big issue for burying system in the distribution submarine cable. This paper demonstrates the measurement error of burial depth that is affected by electrical factor such as grounding type of submarine cable in case of magnetic field detection method, and indicates the method to reduce the measurement error in buried type of distribution submarine cable system.

고온초전도 케이블의 절연파괴 특성에 미치는 Butt gap의 영향 (Effect of Butt Gap in the Electrical Breakdown Properties of a HTS Cable)

  • 곽동순;김영석;김해종;조전욱;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제17권3호
    • /
    • pp.333-339
    • /
    • 2004
  • For an electrical insulation design of HTS cable, it is important to understand the dielectric characteristics of insulation materials in L$N_2$ and the insulation type. Generally, the electrical insulation of HTS Cable is classified into two types of the composite insulation and solid insulation type. In this research, we selected the insulation paper/L$N_2$ composite insulation type for the electric insulation of a HTS cable, and studied electric insulation characteristics of synthetic Laminated Polypropylene Paper(LPP) in liquid nitrogen(L$N_2$) for the application to high temperature superconducting(HTS) cable. Furthermore, we compared the breakdown characteristics of the butt gap and bended mini-model cable. It is necessary to understand the winding parameter of insulation paper/LN2 composite insulation.

AC/DC 하이브리드형 혼합송전계통에서 DC 케이블의 유도전압평가에 의한 적정배열 선정 (Proper Cable Arrangement Selection by Induced Voltage Evaluation of DC Cable in AC/DC Hybrid Combined Transmission Systems)

  • 손용대;이종범
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.680-688
    • /
    • 2015
  • Hybrid type combined transmission systems is being operated by AC and DC line at the same space will be expanded instead of the overhead line. However, such hybrid type combined system has problem like the arrangement selection of DC cable for effective system operation. In this paper, to select the proper arrangement of DC cable, induced voltage of DC cable influenced by AC cable was analyzed in case of several type arrangement of DC cable. Such induced voltage is in detailed analyzed not only in case of steady, but transient state. The arrangement which has the lowest induced voltage is selected as the proper one. EMTP/ATPDraw is used for modeling and analysis of hybrid type combined transmission system.

Shield Metal Embeded Type Epoxy Unit 사용의 OF 케이블용 유지 접속함의 개발 (THE DEVELOPMENT OF STOP JOINT (using Shield Metal Embeded Type Epoxy Unit))

  • 황보승;박현득;이광철;허근도;한기만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.277-280
    • /
    • 1991
  • We have developed 154kV OF cable accessories from 1987. 4 to 1990. 10 by doing assembly design, investing equipment, manufacturing inspecting parts, type testing in labortary, in our company, in KEPCO. The one of those accessories. Oil Stop Joint, has been developed by using Shield Metal Embeded Type Epoxy Unit. This is More reliable than old type.

  • PDF

345kV CV 케이블 접속함의 Proto Type 선정 (Determination of Proto Type for 345kV CV Cable Accessories)

  • 이수길;김인태;손시호;최수걸;허근도;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1629-1631
    • /
    • 1998
  • Crosslinked polyethylene (XLPE) insulated cables are now widely used all over the world for extra-high voltage underground transmission systems. Prefabricated type (compression type) joint has developed in order to shorten the assembly time and lower the possibility of contamination at site by many companies in the world. For outdoor termination, to control the electric field distribution as uniform as possible, especially for the use of extra-high voltage system. much of products are adopting the oil-impregnated condensor cone type instead of electric field control element which uses the permitivity of it only (not capacitance). For Gas-immersed termination, dimension of outer insulation bushing was determined by IEC Publication 859. The highest voltage of underground power cable system is 345kV now, in Korea. We have much of experiences of the development of prefabricated type accessories for CV cable systems (154kV, 161kV, 230kV level). So it was possible to inspect the proto type of accessories for 345kV CV cable system and seems that the need time for the development of products is reduced.

  • PDF

대공간 연성 구조시스템의 종류와 발달과정 (The Type and Development for Structure System with Non-rigid Member)

  • 이주나;박선우;박찬수
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.148-157
    • /
    • 2004
  • The structure systems with non-rigid member were classified by the composition type of line and surface members. As a result of the classification, there are 1-way cable structure, cable net and radial cable net structure in the line member system. And there are pneumatic structure and suspension membrane structure in surface member system. In addition, when the line and surface members are composed together, there is the hybrid membrane system which are divided into hanging type and supported type. In this paper, the Korean terms of structure systems with non-rigid member are recommended through this classification. In each the structure systems with non-rigid member, the examples were also investigated considering their historical developments. It present that the light weight structure system and the openness of space have pursued with the developments. So largely, cable net structure with membrane, membrane structure and hybrid structure have used in these days.

  • PDF

사장교의 내진설계를 위한 동적해석에 관한 연구 (A Study on Dynaniic Analysis for Earthquake Design of cable-stayed Bridges)

  • 이진휴;이재영;이장춘
    • 한국농공학회지
    • /
    • 제36권1호
    • /
    • pp.103-115
    • /
    • 1994
  • The dynamic earthquake analysis of plane cable-stayed bridge structures was formulated and implemented into a computer program which analyzes plane cable-stayed bridge structu- res subjected to initial cable tensions, member dead and live loads and seismic loads. Cable-stayed bridges were modelled as multi-degrees of freedom systems with lumped- mass. Various earthquake responses such as dynamic deflection, bending moment, shear force and cable tension were investigated by the dynamic analyses in the form of the time history analysis. The time history analysis was based on the mode superposition method. The study revealed that Fan-l type cable-syayed bridges is generally superior to other types for the earthquake proof even though aspects of deflection and section force of each type presents respective advantages and disadvantages. The study provided a method to design the sections of cable-stayed bridges under seismic loads with various design parameters related to structural types. The study is expected to be useful for effective design of cable-stayed bridges with conside- ration of earthquake.

  • PDF