• Title/Summary/Keyword: Ca/Ag

Search Result 317, Processing Time 0.023 seconds

Relation of Ethanol and Calcium to Contractile and Electrical Activity of Cat Stomach (고양이 위(胃)의 수축 및 전기활동에 대한 에탄올과 칼슘의 관계)

  • Kim, Myung-Suk;Sim, Sang-Soo;Yoon, Shin-Hee;Han, Sang-Jun;Kim, Chung-Chin;Choi, Hyun
    • The Korean Journal of Physiology
    • /
    • v.21 no.2
    • /
    • pp.259-272
    • /
    • 1987
  • This was study carried out to investigate the effect of calcium on spontaneous contraction and electrical activity induced by ethanol in gastric smooth muscle. After peeling off the mucous membrane from the isolated whole stomach of 102 cats, two kinds of small muscle preparations $(2.0{\times}0.2\;cm)$, one longitudinal and the other circular, were excised from the fundus, the corpus and the antrum portion of each whole stomach specimen. The isometric contraction of the small muscle preparation was measured in a cylinder-shaped chamber filled with Krebs-Ringer-dextrose solution (pH 7.4, temperature $36{\pm}0.5^{\circ}C$) bubbling with 5% $CO_2$ in $O_2$. A large muscle preparation $(5.0{\times}1.2\;cm)$ was excised from the anterior wall of the corpus-antrum portion of the same specimen in 72 of 102 cats. The gastric electrical activity (slow wave and spike potential) was monopolarly recorded by four capillary electrodes (Ag-AgCl), of which two were placed on the corpus and two on the antrum, in a muscle chamber filled with the same solution as described above. Changes in the amplitude of the contraction, frequency of the gastric slow wave and the production of the spike potential were observed after adding ethanol and/or under the treatments with verapamil, $CaCl_2$ and Ca-free Krebs-Ringer-dextrose solution. The results were as follows: 1) After adding ethanol, the spontaneous phasic contraction of the corpus was reduced dose-dependently (0.125-2.0%), which was totally abolished by higher concentrations (2.0-8.0%) of ethanol. 2) The corporal phasic contraction was also completely abolished by verapamil $(3{\times}10^{-5}\;M)$ or Ca-free Krebs-Ringer-dextrose solution. The contraction was increased by $CaCl_2\;(1.8{\times}10^{-3}\;M)$, but the inhibitory effect of ethanol on the contraction persisted even under the treatment with $CaCl_2$. 3) At higher concentrations, ethanol caused tonic contraction of both preparations from the fundus, the corpus and the antrum in a dose-dependent manner. The tonic contraction of the fundus produced by ethanol was not influenced by $CaCl_2$ or verapamil, whereas the tonic contraction was not produced by ethanol in tile Ca-free solution. 4) Frequency of gastric slow wave was decreased dose-dependently by the addition of ethanol (0.25-1.0%), and tile slow wave was not produced by higher concentration of ethanol (2.0%). 5) The frequency of slow wave was significantly reduced by verapamil only and the inhibitory influence of ethanol on the slow wave frequency was reinforced by verapamil. 6) The treatment of $CaCl_2$ increased significantly the slow wave frequency, and attenuated the inhibitory effect of ethanol on the frequency. It is therefore suggested that ethanol regulates the phasic contraction and the production of slow wave by interfering with the transport of calcium in the stomach muscle of the cat.

  • PDF

The Effect of Additives on the Properties of Zn Electrode in Zn/AgO Secondary Battery (Zn/AgO Secondary Battery용 아연 양극의 성능에 미치는 첨가제의 영향)

  • Park, Kyung-Wha;Kim, Chang-Hwan;Moon, Kyung-Man
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • We investigated the effect of both 4 types additives and $0.5wt\%\;Pb_3O_4$ which have been reported to show an improvement on the performance of Zinc anode. And Experimental methods such as corrosion potential measurement, potentiodynamic polorization test and charging-discharging cycle life test were carried out in $40 wt\%$ KOH with $Pb_3O_4(0.5, \;10\;&\;2.0wt\%)$ and 4 types additives $(0.4wt\%\;of\;Ca(OH)_2$, 0.025M of Citrate, Tartrate and Gluconate). Corrosion potential was shifted to high direction and also changed to high and low direction repeatedly with increasing of $Pb_3O_4$ quantity. However by adding $0.5wt\%\;Pb_3O_4$, corrosion potential shifted to low direction and showed stable condition. Furthermore it was well known that corrosion resistance was predominantly increased compared to no addition and improved charging-discharging property with adding additives. By SEM analysis, it was concluded that the morphology of surface in case of only $0.5wt\%\;Pb_3O_4$ addition was nearly the same as that of Tartrate additive and in the other additives such as $Ca(OH)_2$, Citrate, Tartrate and Gluconate, their morphologies showed dendrite growth. Eventually it was thought that the additive of Tartrate indicated comparatively good corrosion resistance effect as well as charging-discharging property improvement among those four types additives.

Current Status of Health Screening in Korea (한국의 건강검진 현황)

  • Jo, Han-Ik
    • Journal of Korea Association of Health Promotion
    • /
    • v.2 no.3
    • /
    • pp.73-96
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items and methods should be carefully selected. This study was to get hold of the test items of major health screening programs in Korea Most of the health screening programmes focused upon detection of risk factors and diagnosis of life - style related diseases (diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis) ,cancers (stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus) , infectious diseases (hepatitis, tuberculosis, sexually-transmitted diseases, parasites) , chronic obstructive respiratory diseases, chronic renal diseases (bacteriuria hematuria, proteinuria) , anemia, glaucoma, hearing loss, Alzheimer disease, stress, early psychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests (CBC, urinalysis, liver function tests, lipid tests, glucose, HbAlc, uric acid, electrolytes, serological tests (HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray (chest PA, CT) , endoscopy (gastroscopy, colonoscopy) , sonography(abdomen, thyroid, pelvis, breast) ,cytology (cervix) , bone density, tumor markets (NMP22, alpha-FP, CEA, CA-19-9, CA12S, PSA) and eye tests. Advanced technologies, like CT, PET, MRI, MRT/Angio, molecular testings) were widely used in hospital health screening programmes .In summary, a variety of tests were utilized in health screening in Korea. Those tests were utilized by stages or according to sex and age in most of health screening programmes, however a few program used tests to excess disregarding health screening subjects.

  • PDF

Effect of Processing Variables on Microstructure and Critical Current Density of BSCCO Superconductors Tape (BSCCO 초전도 선재의 미세조직 및 임계전류밀도에 미치는 공정변수 효과)

  • 지봉기;김태우;주진호;김원주;이희균;홍계원
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.11
    • /
    • pp.1014-1021
    • /
    • 1998
  • We evaluated the effect of processing variables on microstructural evolution interface irregularity between Ag sheath and superconductor core and resultant critical current density(J$_{c}$) of (Bi,Pb)$_2$Sr$_2$Ca$_2$Cu$_3$O$_{x}$(2223) superconductor tape. The value of J$_{c}$ was significantly influenced by the interface irregularity, degree of texturing and relative 2223 content. The interface became more irregular(sausage effect), while the degree of texturing gradually improved as the dimension of tape decreased during forming process. As the dimension of wire/tape were changed from diameter of 3.25 mm to thickness of 0.20 mm, J$_{c}$ value was observed to be increased by 10 times. In addition, optimum sintering temperature for improved J$_{c}$ was observed to be 835$^{\circ}C$ in a ambient atmosphere probably due to combined effect of both improved texturing and high 2223 content. Microstructural investigation showed the degree of texturing was degraded by the existence of both second phases and interface irregularity. It was observed that larger grain size and better texturing was developed near relatively flat interface compared to those inside superconducting core.ting core.

  • PDF

국내 주요 기관의 건강진단 검사 종목

  • Jo, Han-Ik;Kim, Sang-In
    • Journal of Korea Association of Health Promotion
    • /
    • v.2 no.1
    • /
    • pp.9-25
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items of major health screening program in Korea. Most, of the health screening programmes focused upon detection of risk factors and diagnosis of life-style related diseases(diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis), cancers(stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus), infections diseases(hepatitis, tuberculosis, sexually-transmitted diseases, parasites), chronic obstructive respiratory diseases, chronic renal diseases(bacteriuria, hematuria, proteinuria), anemia, glaucoma, hearing loss, Alzheimer disease, stress and earlypsychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests( CBC, urinalysis, liver function tests, lipid tests, glucose, HbA1c, uric acid, electrolytes, serological tests(HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray(chest PA, CT) endoscopy(gastroscopy, colonoscopy), sonography (abdomen, thyroid, pelvis, breast), cytology(cervix), bone density, tumor markers(NMP22, alpha-FP, CEA, CA-19-9, CA125, PSA and eye tests. Advanced technologies, like CT, PET, MRI, MRI/Angio, molecular testing were widly used in hospital based health screening programmes. In summary, a variety of tests were untilized in health screening in Korea. Those tests were utilized by stages or according to sex and age in most of health screening programmes, however a few programs used tests excessvely disregarding health screening subjects.

  • PDF

$CaSnO_3$와 소결조제가 첨가된 $BaTiO_3$ 유전체 세라믹의 소결거동 및 유전특성

  • Kim, Tae-Hong;Lee, Jae-Shin;Choy, Tae-Goo
    • ETRI Journal
    • /
    • v.13 no.2
    • /
    • pp.42-53
    • /
    • 1991
  • 고유전율 적충세라믹 커패시터 소재인 $BaTiO_3$ 자기물은 일반적으로 큐리오도인 약 $120^{\circ}C$부근에서 유전율이 최고 약 10,000정도로 증가한 다음 급격히 감소하므로 적절한 이동체를 첨가하여 큐리온도를 상온으로 이동시켜 상온에서 최대 유전율을 이용하여야 한다. 그리고$BaTiO_3$ 자기물은 $1300^{\circ}C$이상의 고온소결시 고가인 Pd전극이 요구된다. 그러나 자기물의 소결온도를 저온화화면 저가의 Ag합금으로 전극재료를 대체할 수 있다. 본 연구에서는 이동제로서 $CaSnO_3$ 를 이용하여 큐리온도를 상온으로 이동시켰다. 또한 소결온도를 저온화하기 위하여 $BaTiO_3$ 세라믹에 여러가지 산화물을 첨가하여 소결현상을 살펴보았다. 실험결과 첨가제를 넣지 않은 경우 소결온도는 $1350^{\circ}C$의 고온이 필요한 반면, $CuO,B_2O_3$$1050^{\circ}C$의 낮은 온도에서도 치밀화와 입도성장이 잘 일어났다. 특히 $B_2$$O_3$ 를 첨가한 경우는 $1250^{\circ}C$이상에서 소결할 때 절연저항이 낮아 유전손실이 큰 문제점을 보였지만, 최대 유전율이 11,000 정도로 높고, 양호한 유전율의 온도변화 특성을 나타내어 우수한 고유전율 소재의 첨가제로 응용될 가능성을 보였다

  • PDF

The Study of Glass Crystallization Mechanism Using Femtosecond Laser Pulse (극초단파레이저를 활용한 유리의 결정화 메커니즘 고찰)

  • Moon P.Y.;Yoon D.K.;Lee K.T.;Shin S.B.;Cho S.H.;Ryu B.K.
    • Transactions of Materials Processing
    • /
    • v.15 no.3 s.84
    • /
    • pp.213-219
    • /
    • 2006
  • To improve the strength of glass is being studied in order to contribute to weight saving of flat panel displays. Generally, the strength achieved of glass-ceramics is higher as is the fracture toughness by the formation of a heterogeneous phase inside glass. In this study, Ag-doped $45SiO_2-24CaO-24Na_2O-4P_2O_5\;and\;70SiO_2-10CaO-24Na_2O-10TiO_2$ glasses were irradiated to strengthen by crystallization using femto-second laser pulse. XRD, Nano-indenter and SEM etc., irradiation of laser pulse without heat-treated samples was analyzed. Samples irradiated by laser had higher value($4.4{\sim}4.56^*10-3Pa$) of elastic modulus which related with strength of glass than values heat-treated samples and these are $1.2{\sim}1.5$ times higher values than them of mother glass. This process can be applicable to the strengthening of thinner glass plate, and it has an advantage over traditional heat-treatment and ion-exchange method.

Effects of Alloying Elements on the Surface Characteristics of Pb-Substrate for Battery (Pb-기판의 표면특성에 미치는 합금원소의 영향)

  • Oh, S.W.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.6
    • /
    • pp.302-311
    • /
    • 2006
  • Nowadays the open-type lead-acid battery for vehicle use is being replaced with the sealed-type because it needs no maintenance and has a longer cycle life. Thus researches on this battery are being conducted very actively by many advanced battery companies. There is, however, a serious problem with the maintenance free(MF) battery that its cathode electrode has a limited cycle life due to a corrosion of grid. In this study, it was aimed to improve a corrosion resistance of the cathode grid which is commonly made of Pb-Ca alloy for a mechanical strength. For this purpose, various amounts of alloying elements such as Sn, Ag and Ba were added singly or together to the Pb-Ca alloys and investigated their corrosion behaviors. Batteries fabricated by using these alloys as cathode grids were subjected to life cycle test and their corrosion layers appeared at the interface between the grids and the active materials were carefully observed in order to clarify effects of alloying elements.

Current Status of Health Screening in Korea (한국의 건강검진 현황)

  • Jo, Han-Ik
    • Journal of Korea Association of Health Promotion
    • /
    • v.2 no.2
    • /
    • pp.215-230
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items and methods should be carefully selected. This study was to get hold of the test items of major health screening programs in Korea. Most of the health screening programmes focused upon detection of risk factors and diagnosis of life-style related diseases(diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis) ,cancers(stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus), infectious diseases (hepatitis, tuberculosis, sexually-transmitted diseases, parasites),chronic obstructive respiratory diseases, chronic renal diseases(bacteriuria, hematuria, proteinuria), anemia, glaucoma, hearing loss, Alzheimer disease, stress, early Psychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests(CBC, urinalysis, liver function tests, lipid tests, glucose, HbAlc, uric acid, electrolytes, serological tests(HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray(chest PA, CT), endoscopy (gastroscopy, colonoscopy) , sonography(abdormen, thyroid, pelvis, breast) , cytology(cervix) ,bone density, tumor markers(NMP22, alpha-FP, CEA, CA-19-9, CA12S, PSA) and eye tests. Advanced technologies, like CT, PET, MIRI, MIRI/Angio, molecular testings) were widely usedin hospital health screening programmes. In summary, a variety of were utilized by stages or programmes, however a few subjects. tests were utilized in health screening in Korea. Those tests according to sex and age in most of health screening program used tests to excess disregarding health screening subject.

  • PDF

Gahnite-Sillimanite-Garnet Mineral Assemblage from the Host Rocks of the Cannington Deposit, North Queensland, Australia: Relationship between Metamorphism and Zn-Mineralization (호주 퀸즈랜드 주 캔닝턴 광상 모암의 아연-첨정석-규선석-석류석에 관한 연구 :변성작용과 아연-광화작용에 대해서)

  • Kim Hyeong Soo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.309-325
    • /
    • 2004
  • The Cannington Ag-Pb-Zn deposit, northwest Queensland, Australia developed around the host rocks composing banded and migmatitic gneisses, sillimanite-garnet schist and amphibolite. Three crystal habits of sillimanite, gahnite (Zn-spinel) and garnet porphyroblasts occurred on the host rocks of the Cannington deposit could be used to delineate metamorphism that closely associated with Zn-mineralization in the deposit. Linkages the metamorphism to Zinc-mineralization is determined in four chemical systems, KFMASH (K$_2$O-FeO-MgO-Al$_2$O$_3$-SiO$_2$-$H_2O$), KFMASHTO (K$_2$O-FeO-MgO-Al$_2$O$_3$-SiO$_2$-$H_2O$-TiO$_2$-Fe$_2$O$_3$), NCKFMASH (Na$_2$O-CaO-K$_2$O-FeO-MgO-AlO$_3$-SiO$_2$-$H_2O$) and MnNCK-FMASH (MnO-Na$_2$O-CaO-K$_2$O-FeO-MgO-AlO$_3$-SiO$_2$-$H_2O$), using THERMOCALC program (version 3.1; Powell and Holland 1988). Partial melting in MnNCKFMASH and NCKFMASH systems occurs at lower temperature than in the KFMASH and KFMASHTO systems. The partial melting temperature decreases with increasing of Na/(Na+Ca+K) of the bulk rock compositions in the MnNCKFMASH system. The host rocks have melted ca 15 vol.% in the MnNCKFMASH system at peak metamorphic conditions (634$\pm$62$^{\circ}C$ and 4.8$\pm$1.3 kbar), but partial melting have not occurred in KFMASHTO system. Based on calculations of sillimanite isograd in different systems and sillimanite modal pro-portion, prismatic and rhombic sillimanite and gahnite porphyroblasts including prismatic sillimanite inclusion probably have resulted from pressure and temperature increasing through partial melting (from 550~$600^{\circ}C$, 2.0~3.0 kbar to 700~75$0^{\circ}C$, 5.0~7.0 kbar), furthermore have experienced N-S then W-E crustal shortening during D$_1$ and D$_2$ deformation. Consequently, Zinc mineralization related to gahnite growth occurred during D$_2$ and was redistributed and upgraded by partial melting and retrograde metamorphism into structural and rheological sites during shearing in D$_3$.