• 제목/요약/키워드: CZT crystal

검색결과 9건 처리시간 0.022초

EFFECT OF METAL CONTACT ON THE CZT DETECTOR PERFORMANCE

  • Park, Se-Hwan;Park, Hyung-Sik;Lee, Jae-Hyung;Kin, Han-Soo;Ha, Jang-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.65-68
    • /
    • 2009
  • Metal-semiconductor contact is very important for the operating property of semiconductor detector. $Cd_{0.96}$ $Zn_{0.04}$ Te semiconductor crystal was grown with Bridgman method, and the crystal was cut and polished. EPMA (Electron Probe Micro Analyzer) and ICP-MS (Inductively Coupled Plasma Mass Spectrometry) analysis were done to obtain the chemical composition and impurity of the crystal. Metal contact was deposited with thermal evaporator on both sides of the crystal. Detectors with Au/CZT/Au and In/CZT/Au structure were made, and I-V curve and the energy spectrum were measured with the detectors. It could be seen that the detector with the In/CZT/Au structure has superior property than the detector with Au/CZT/Au structure when the crystal resistivity was low. However, the metal contact structure effect becomes low when the crystal resistivity was high.

Passivation effect on large volume CdZnTe crystals

  • B. Park;Y. Kim;J. Seo;J. Byun;K. Kim
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4620-4624
    • /
    • 2022
  • Several cadmium zinc telluride (CZT) crystals were fabricated into radiation detectors using methods that included slicing, dicing, lapping, polishing, and chemical etching. A wet passivation with sodium hypochlorite (NaOCl) was then carried out on the Br-etched detectors. The Te-rich layer on the CZT surface was successfully compensated to the Te oxide layer, which was analyzed with X-ray photoelectron spectroscopy data of both a Br-etched crystal and a passivated CZT crystals. We confirmed that passivation with NaOCl improved the transport property by analyzing the mobility-lifetime product and surface recombination velocity. The electrical and spectroscopic properties of large volume detectors were compared before and after passivation, and then the detectors were observed for a month. Both bar and quasi-hemispherical detectors show an enhancement in performance after passivation. Thus, we could identify the effect of NaOCl passivation on large volume CZT detectors.

Radiation measurement and imaging using 3D position sensitive pixelated CZT detector

  • Kim, Younghak;Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1417-1427
    • /
    • 2019
  • In this study, we evaluated the performance of a commercial pixelated cadmium zinc telluride (CZT) detector for spectroscopy and identified its feasibility as a Compton camera for radiation monitoring in a nuclear power plant. The detection system consisted of a $20mm{\times}20mm{\times}5mm$ CZT crystal with $8{\times}8$ pixelated anodes and a common cathode, in addition to an application specific integrated circuit. The performance of the various radioisotopes $^{57}Co$, $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ was evaluated. In general, the amplitude of the induced signal in a CZT crystal depends on the interaction position and material non-uniformity. To minimize this dependency, a drift time correction was applied. The depth of each interaction was calculated by the drift time and the positional dependency of the signal amplitude was corrected based on the depth information. After the correction, the Compton regions of each spectrum were reduced, and energy resolutions of 122 keV, 356 keV, 511 keV, and 662 keV peaks were improved from 13.59%, 9.56%, 6.08%, and 5%-4.61%, 2.94%, 2.08%, and 2.2%, respectively. For the Compton imaging, simulations and experiments using one $^{137}Cs$ source with various angular positions and two $^{137}Cs$ sources were performed. Individual and multiple sources of $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ were also measured. The images were successfully reconstructed by weighted list-mode maximum likelihood expectation maximization method. The angular resolutions and intrinsic efficiency of the $^{137}Cs$ experiments were approximately $7^{\circ}-9^{\circ}$ and $5{\times}10^{-4}-7{\times}10^{-4}$, respectively. The distortions of the source distribution were proportional to the offset angle.

Feasibility study of SiPM based scintillation detector for dual-energy X-ray absorptiometry

  • Park, Chanwoo;Song, Hankyeol;Joung, Jinhun;Kim, Yongkwon;Kim, Kyu Bom;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2346-2352
    • /
    • 2020
  • Dual-energy x-ray absorptiometry (DXA) is the noninvasive method to diagnose osteoporosis disease characterized by low bone mass and deterioration of bone tissue. Many global companies and research groups have developed the various DXA detectors using a direct photon-counting detector such as a cadmium zinc telluride (CZT) sensor. However, this approach using CZT sensor has some drawback such as the limitation of scalability by high cost and the loss of efficiency due to the requirement of a thin detector. In this study, a SiPM based DXA system was developed and its performance evaluated experimentally. The DXA detector was composed of a SiPM sensor coupled with a single LYSO scintillation crystal (3 × 3 × 2 ㎣). The prototype DXA detector was mounted on the dedicated front-end circuit consisting of a voltage-sensitive preamplifier, pulse shaping amplifier and constant fraction discriminator (CFD) circuit. The SiPM based DXA detector showed the 34% (at 59 keV) energy resolution with good BMD accuracy. The proposed SiPM based DXA detector showed the performance comparable to the conventional DXA detector based on CZT.

이동형 핵종 분석 장치용 CZT 반도체 검출기의 완충전극에 대한 연구 (A Study of Interface Layer on CdZnTe Radiation Sensor for Potable Isotope Identifier)

  • 조윤호;박세환;김용균;하장호
    • 방사선산업학회지
    • /
    • 제5권1호
    • /
    • pp.95-99
    • /
    • 2011
  • The electrical and mechanical properties of electrode for radiation detection are very important. In general, Au electrode and CZT crystal are combined to form ohmic contacts, and the best energy resolution is shown at the Au electrode. The metal contacts are fabricated by electroless deposition method, sputtering deposition method and thermal evaporation method. The electrode fabrication is easy with use of the thermal evaporation method, while an adhesive strength is weak. Thus interface materials such as Ag, Al and Ni were investigated to overcome defects generated by the this method. The thickness of the interface material between the Au electrode and the CZT crystal was 100 Angstroms, the Au electrode with thickness of 400 Angstroms was deposited. The Al+Au electrode is shown that the results of current-voltage and radiation response are similar to results of Au electrode.

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

  • Lee, Jun;Kim, Younghak;Bolotnikov, Aleksey;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4080-4092
    • /
    • 2021
  • In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm3. The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80%), while those evaluated using the minimum squared difference method (55-59%) and Three Compton method (45-55%) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

EBE로 증착된 반도체 CdZnTe 박막의 결정구조와 표면조성 (The structure and the surface composition of semiconductor CdZnTe films by EBE)

  • 박국상;김선옥;이기암
    • 한국결정성장학회지
    • /
    • 제5권1호
    • /
    • pp.25-36
    • /
    • 1995
  • 유리기판(Corning 7059) 위에 Electron Beam Evaporator(EBE)로 진공 중에서 증착된 $Cd_{1-y}Zn_{y}Te$(CZT) 박막의 표면 조성비와 결정구조를 조사하였다. 증착시 기판의 온도는 각각 실온과 $300^{\circ}C$였으며, 열처리는 압력 $1 {\times} 10^{-6}$ torr하에서 $300^{\circ}C$에서 1시간 동안 행하였다. 증착된 CZT 박막의 표면조성비는 Cd 원자가 상대적으로 약 4% 정도 부족하였고, Zn원자는 비교적 안정하였다. 박막의 구조는 거의 Cubic phase인 다결정(polycrystal)이었다. $400^{\circ}C$에서 측정된 X-선 분말 회절상으로부터 구한 격자상수 값으로부터 계산된 열팽창 계수는 $6.30 {\times} 10^{-6}/^{\circ}C$ 이었다. 박막은 열처리에 의하여 회절상의 peak가 증가하였으나 기판의 온도가 결정화에 더 큰 영향을 미치는 것으로 판단된다.

  • PDF

High-Performance Compton SPECT Using Both Photoelectric and Compton Scattering Events

  • Lee, Taewoong;Kim, Younghak;Lee, Wonho
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1393-1398
    • /
    • 2018
  • In conventional single-photon emission computed tomography (SPECT), only the photoelectric events in the detectors are used for image reconstruction. However, if the $^{131}I$ isotope, which emits high-energy radiations (364, 637, and 723 keV), is used in nuclear medicine, both photoelectric and Compton scattering events can be used for image reconstruction. The purpose of our work is to perform simulations for Compton SPECT by using the Geant4 application for tomographic emission (GATE). The performance of Compton SPECT is evaluated and compared with that of conventional SPECT. The Compton SPECT unit has an area of $12cm{\times}12cm$ with four gantry heads. Each head is composed of a 2-cm tungsten collimator and a $40{\times}40$ array of CdZnTe (CZT) crystals with a $3{\times}3mm^2$ area and a 6-mm thickness. Compton SPECT can use not only the photoelectric effect but also the Compton scattering effect for image reconstruction. The correct sequential order of the interactions used for image reconstruction is determined using the angular resolution measurement (ARM) method and the energies deposited in each detector. In all the results of simulations using spherical volume sources of various diameters, the reconstructed images of Compton SPECT show higher signal-to-noise ratios (SNRs) without degradation of the image resolution when compared to those of conventional SPECT because the effective count for image reconstruction is higher. For a Derenzo-like phantom, the reconstructed images for different modalities are compared by visual inspection and by using their projected histograms in the X-direction of the reconstructed images.

Cd$_{0.96}$Ze$_{0.04}$Te 박막의 전기 광학적 특성 (The electrical and optical properties of Cd$_{0.96}$Ze$_{0.04}$Te thin films)

  • 김선옥;현준원
    • 한국표면공학회지
    • /
    • 제31권6호
    • /
    • pp.389-392
    • /
    • 1998
  • We have investigated the crystal properties of the Cd0.96Zn0.04Te(CZT) films evaporated on the Si(100) substrates by Elecctron Beam Evaporator(EBE) techique. The compositions of the As-preared films were different about 4% of atomic ratio, The films stucture was observad to be polycrystalline in cubic phase. Diffraction peaks were notable at the substrate temperature of $300^{\circ}C$. The reflectance measurements yield $E_1$=3.25~3.29 eV $E_1$+${\Delta}_1$=3.76~3.83 eV and $E_2$=5.08 eV,showing that the films wear in cubic phase. For the film evaporated at the substrate temperature of $150^{\circ}C$, the peaks of photocurrent are at 720nm and 980nm.

  • PDF