• Title/Summary/Keyword: CV characteristics

Search Result 486, Processing Time 0.023 seconds

Breeding of Medium Standard Rose, 'Honey Lemon' with White Color and Good Vase Life (절화수명이 긴 백색 중형 스탠다드 장미 'Honey Lemon' 육성)

  • Kim, Seung-Tae;Kim, Won-Hee;Lee, Eun-Kyung;Lee, Su-Young;Huh, Kun-Yang
    • Korean Journal of Breeding Science
    • /
    • v.42 no.3
    • /
    • pp.284-287
    • /
    • 2010
  • A new standard rose cv. 'Honey Lemon' was bred by the cross between white standard cv. 'Escimo' and light pink standard cv. 'Medeo' at the National Institute of Horticultural Research Institute. The cross was made in 1999 and 'Honey Lemon' was finally selected in 2003 after investigating characteristics for three years from 2001 to 2003. 'Honey Lemon', a white standard cultivar grows vigorously and has good flower shape. The major characteristics of this cultivar are $248.0stems/m^2/year$ in yield, 53.0 cm in length of cut flower, 8.0 cm in flower diameter, 17.0 in petal number, and 16.9 days in vase life. This cultivar can be propagated by both cutting and grafting. The consumer's preference of this cultivar is relatively higher than that of control cv., 'Tineke'. (Registration number: 1151).

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Acoustic Characteristics and Auditory Cues for Korean Lax vs. Tense Fricative Distinction (한국어 평마찰음과 경마찰음의 음향적 특성과 지각 단서 - 길이를 중심으로 -)

  • 이경희;이봉원
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.95-100
    • /
    • 2000
  • The purpose of this paper is to show their distinctive auditory cues. Until now research of acoustic characteristics has been confined to simple experiments concerning the restricted conditions. Therefore this paper examines all of the acoustic characteristics of the lax and tense Fricative Consonants and shows to how acoustic characteristics can be used to differentiate lax and tense Fricative Consonants. The results of this paper are (a) auditory cues are especially important if there is a large difference between acoustic characteristics, (b) the lax and tense Fricative Consonant's distinctive auditory cues contain a hierarchy, and (c) there is a different hierarchy between CV and VCV.

  • PDF

Analysis of Clinical Features and Treatment of Patients Presenting Dyspepsia Related to COVID-19: Retrospective Chart Review (코로나 관련 소화불량을 호소하는 환자의 임상적 특징 및 치료 분석 : 후향적 차트 분석)

  • Nahyun Jeong;Chae-Rim Yoon;Su-Hyun Choi;Dahee Jeong;Yoohyun Sim;Hae-in Jeong;Na-Yeon Ha;Jinsung Kim
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.3
    • /
    • pp.381-395
    • /
    • 2024
  • Objectives: The main purpose of this study is to investigate the clinical characteristics of patients complaining of indigestion after COVID-19 infection (CI) or COVID-19 vaccination (CV) and to confirm the effectiveness and safety of Korean medical treatment. Methods: We retrospectively collected and investigated the medical records of 39 patients admitted to the Kyung Hee University Korean Medicine Hospital with a chief complaint of dyspepsia from January 1, 2020 to February 29, 2024 who reported the onset or significant exacerbation of dyspepsia after CV or CI. Patients were divided into vaccination and infection groups, and their demographic characteristics, Ryodoraku results, presenting symptoms, traditional Korean medicine treatments, and treatment outcomes were analyzed. Results: When comparing the groups with dyspepsia after CV and after CI, it was observed that the CI group had significantly lower average body weight, and the measurements of LH6, LF1, and LF6 in the Ryodoraku test were significantly lower. Additionally, compared to the CV group, the CI group showed significantly more abdominal distension, nausea, and abdominal pain. Significant relief of upper gastrointestinal symptoms was observed in both the CV and CI groups after treatment. No adverse reactions were observed during the course of treatment. Conclusion: The CI group tended to complain more severely of various dyspeptic symptoms and had a tendency to lower body weight than the CV group, as was also reflected in the results of the Ryodoraku test. Korean medical treatment can be effective and safe in treating these patients.

Physicochemical characteristics of El salvadoran Coffea arabica cv. Bourbon coffee extracts with various roasting conditions (로스팅 조건에 따른 엘살바도르산 Coffea arabica cv. Bourbon 커피의 이화학적 특성)

  • Kim, Inyong;Jung, Sunyoon;Kim, Eunkyung;Yun, Hea-Yeon;Zhang, Seokam;Ha, Jung-Heun;Jeong, Yoonhwa
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.3
    • /
    • pp.212-219
    • /
    • 2020
  • The physicochemical characterstics of El Salvadoran Coffea arabica cv. Bourbon coffee extracts under various roasting conditions were investigated. Green beans were roasted under four different conditions (Light-medium, Medium, Moderately dark, and Very dark). The coffee extracts were prepared by using the espresso or drip methods. As the roasting degree increased, the coffee bean moisture content decreased and the ash content increased. The lightness and yellowness of the beans and coffee extracts decreased along with the increasing roasting degree. In the drip coffee, the reducing sugar content decreased and the pH value increased along with the increasing roasting degree. Both in the espresso and drip coffee, total organic acid and chlorogenic acid contents decreased, while the caffeine content increased along with the increasing roasting degree. Therefore, it is suggested that the roasting degree affects the physicochemical characteristics of coffee extracts.

Experimental Investigation of the Effect of Composition on the Performance and Characteristics of PEM Fuel Cell Catalyst Layers

  • Baik, Jung-Shik;Seong, Dong-Mug;Kim, Tae-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.157-160
    • /
    • 2007
  • The catalyst layer of a proton exchange membrane (PEM) fuel cell is a mixture of polymer, carbon, and platinum. The characteristics of the catalyst layer play critical role in determining the performance of the PEM fuel cell. This research investigates the role of catalyst layer composition using a Central Composite Design (CCD) experiment with two factors which are Nafion content and carbon loading while the platinum catalyst surface area is held constant. For each catalyst layer composition, polarization curves are measured to evaluate cell performance at common operating conditions, Electrochemical Impedance Spectroscopy (EIS), and Cyclic Voltammetry (CV) are then applied to investigate the cause of the observed variations in performance. The results show that both Nafion and carbon content significantly affect MEA performance. The ohmic resistance and active catalyst area of the cell do not correlate with catalyst layer composition, and observed variations in the cell resistance and active catalyst area produced changes in performance that were not significant relative to compositions of catalyst layers.

  • PDF

Analysis of Electric Field Distribution and Characteristics of Volume Resistivity in HDPE/EVA Film for Recycling (재활용을 고려한 HDPE/EVA필름의 전계분포 및 체적저항특성 해석)

  • Lee, Hung-Kyu;Lim, Kee-Joe;Kim, Yong-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.801-807
    • /
    • 2008
  • Recently, CV, CN-CV and CNCV-W cable are used for HVDC transmission and distribution cable. However, XLPE which is used as insulation layer of power cable has thermosetting properties. It is very difficult to recycling. In this paper, we prepared HDPE/EVA film, which the blending ratio are 80:20, 70:30, 60:40, 50;50 respectively for the purpose of recycling. Main factor such as electric field distribution and its resistivity in insulation system affected on insulation performance and reliability for HVDC applications. Therefore, electric field distribution formed by space charge and characteristics of volume resistivity was currently investigated. We suggest the possibility of utilization for HVDC insulation layer from the results.

Electrochemistry and Corrosion Characteristics of Polyaniline Dispersion Coating for Protection of Steels (강철보호를 위한 폴리아닐린 분산 코팅의 전기화학 및 부식특성)

  • Huh, Jae-Hoon;Oh, Eung-Ju;Cho, Jeong-Hwan
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.113-118
    • /
    • 2003
  • Processible polyaniline (PAM) dispersions consisting of polyaniline micro-particles, cyclohexanone, and a polymeric surfactant were prepared in a micro-milling machine with various mixing conditions. The electrochemical properties of the dispersion film coated on Pt electrode were investigated by cyclic voltammetry (CV). The electrochemistry of the PAM dispersion coatings was basically similar to a pure PAM coating based on the results of CV. The results of polarization measurements and open circuit potential measurements carried out in $3\;wt.\%$ NaCI solution showed increase in corrosion potential when the PANI dispersion coatings applied on steel surface. Variation of open circuit potential $(OCP,\;V_{OC})$ of the dispersion coating/steel electrodes was observed, which differed with milling conditions. The results demonstrated practical use of the conducting polymer dispersion as a coating material for corrosion prevention of steel.

Comparison and Examination of the Measured Data With the Data from Other Company for the Conductor and Sheath Temperatures of Live 6 kV CV Single Core Cables (활선 6 kV CV 단심 케이블의 도체 및 표면온도 측정 데이터에 관한 타사 데이터와의 비교검토)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.197-201
    • /
    • 2017
  • The demand for electric power is increasing every year in Korea. All the systems adopted at power stations in order to generate and transmit electric power should operate in perfect condition or reliability. The device for transmitting the generated high-voltage electric power is 6 kV CV single core cables. The manufacturing companies of the cables makes an official announcement that the operating lifetime of their cables is about 30years. But from the moment of operation the deterioration precesses of worsening the characteristics of cables starts. Since the reliability for the status of installed cables in deterioration has not been diagnosed, the cables can be broken at any unexpected moments. In order to prevent the abrupt cable accident by systematically monitoring the cable status, we have invented the first device in Korea. We have installed our device at Korea Western Power Co. Ltd. in order to diagnose the live cables. In this paper, we present our research results of measured temperatures of inner conductor and surface and the compared results of those data with other cable company. We also show that our results agree with those made by other company.

Evaluation of Growth Characteristics and Yield Potential of Summer Emergency Forage Crops (하계 응급 조사료 자원의 생육특성 및 조사료 생산성 평가)

  • Park, Hyung Soo;Choi, Ki Choon;Yang, Seung Hak;Jung, Jeong Sung;Lee, Bae Hun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.42 no.1
    • /
    • pp.26-31
    • /
    • 2022
  • This study was carried out to evaluate the growth characteristics and forage yield potential for warm season grass as emergency forages. The experimental design was a randomized block design (RBD) with three replications. Two barnyard millet (Echinochloa species cv. Shirohie and Jeju native), a pearl millet (Pennisetum glaucum cv Feed milk 2) a proso millet (Panicum miliaceum cv Native), a teffgrass (Eragrostis tef cv. Tiffany) and a kleingrass (Panicum coloratum cv. Selection 75) were compared for forage production and quality at the Mid regions of Korea. Warm season forage crops were sown on May 21 and June 23 respectively, and in 2021, it was sown twice on May 21 and June 21 The number of days to seedling emergence for barnyard millet and teffgrass was observed approximately 10 and 3 days after seeding, respectively. The cultivation period from seeding to harvest was within 60 days for all entry spices except for the late-heading type barnyard millet (within 84 days). As for the dry matter yield by seeding date, the dry matter yield of the late-heading type barnyard millet in May seeding was the highest at 23,872 kg/ha, and the kleingrass was the lowest at 3,888 kg/ha. For the June seeding, the dry matter yield of the late-heading type barnyard millet was 17,032 kg/ha, the highest, and the proso millet, teffgrass and kleingrass showed the lowest at 5,468, 5,442, and 5,197 kg/ha, respectively. The crude protein (CP) content was varied by warm season grass species, but the early-heading type barnyard millet, teffgrass, and kleingrass showed the highest tendency, and the late-heading type barnyard millet showed the lowest at 5.7~5.9%. Neutral detergent fiber (NDF) and acid detergent fiber (ADF) content did not show a significant difference between the seeding in May, but kleingrass in June sowed lower than the others.