• Title/Summary/Keyword: CV characteristics

Search Result 486, Processing Time 0.022 seconds

Accumuation Pattern of Nitrate-Nitrogen in Sorghum And Maize Plants as Affected by Morphological Characteristics And Environmental Temperature (Sorghum 및 옥수수의 형태적 특성과 재배온도가 Nitrate-Nitrogen 축적에 미치는 영향)

  • 김정갑
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.7 no.3
    • /
    • pp.146-152
    • /
    • 1987
  • Sorghum cv. Pioneer 93 1, sorghum-sudangrass hybrid cv. Sioux and maize plant cv. Blizzard were assayed for toxic concentrations of nitrate-nitrogen ($NO_3$-N) and their relationship to morphological characteristics and environmental temperature in a field and phytotron trial. In the phytotron, sorghum and maize plants ranging from emergence to heading stage, were grown under different day/night temperatures of 30125, 25/20,28/18 and 1818 degree C. Nitrate-nitrogen in sorghum and maize plants was accumulated mainly in stems. Therefore nitrate concentration in the young plants was increased as development of stalks advanced and was highest at the stage of 3-4 leaves, when the plants had a leaf weight ratio 0.78-0.80 g/g plant weight. However, nitrate concentrations of the plant decreased as morphological development progressed, especially from the stage of growing point differentiation. Correlation coefficients showed a positive correlation of nitrate concentration with leaf weight ratio, leaf area ratio and specific leaf area, while plant height, dry matter percentage and absolute growth rate showed a negative association with TEX>$NO_3$-N ($P{\le}0.1$%). Cyanogenic glycosides, total nitrogen and crude protein were close associated with nitrate accumulation, and positively significant ($P{\le}0.1$%). High temperature over 30/25^{\circ}C.$ for 3 weeks increased N-uptake and dry matter accumulation, but reduced nitrate concentration. Under cold temperature below 18/8^{\circ}C.$ concentration of nitrate-N was increased in spite of its limited nitrogen uptake and plant growth.

  • PDF

Analysis of Spray Characteristics of Tractor-mounted Boom Sprayer for Precise Spraying

  • Kim, Ki-Duck;Lee, Hyeon-Seung;Hwang, Seok-Joon;Lee, Young-Joo;Nam, Ju-Seok;Shin, Beom-Soo
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.258-264
    • /
    • 2017
  • Purpose: This study determines the spray characteristics and effective spray width of a tractor-mounted commercial boom sprayer through experiments. Methods: Performance tests were conducted to investigate the spray characteristics of the nozzles on a commercial boom sprayer. The flow rate and spray width of a single nozzle were measured at three levels of spray pressure (0.5, 0.7, and 1.0 MPa) and spray height (15, 30, and 45 cm), respectively. The average value of three repetition tests was used as the representative value. A coefficient of variation (CV) was used as an index of spray uniformity, and the width that guarantees CV values of approximately 15% was determined as the effective spray width. The spray characteristics of the overall boom sprayer were derived analytically by superimposing the spray characteristics of a single nozzle. Results: The test results for a single nozzle showed that the spray width tended to increase as the spray height and spray pressure increased. The effective spray width for a single nozzle was the largest at a spray pressure of 1.0 MPa and spray height of 45 cm, which resulted in a coverage of 84 cm of width. The effective spray width for the entire boom sprayer was also the largest at the spray pressure of 1.0 MPa and spray height of 45 cm, with a magnitude of 424.5 cm. The chemical spraying work in an actual field was simulated by applying a spray width of 400 cm. As a result of the operation for three swaths, the CV value was less than 10% for 1,200 cm of the overall spray width, which meant that uniform application was achieved. Conclusions: It was reasonable to set the effective spray width of the boom sprayer used in this study to 400 cm.

Design of the Detection Circuitry for the Characteristics of Micromachined Vibrating Gyroscope (미세가공 진동형 자이로스코프의 특성 감지 회로의 설계에 관한 연구)

  • U, Yeong-Sin;Byeon, Gwang-Gyun;Seo, Il-Won;Seong, Man-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.10
    • /
    • pp.687-692
    • /
    • 1999
  • A new technique to measure low level capacitance variations of the gyroscope is proposed and verified by computer simulation. It is based on the new CV(capacitance-voltage) converter circuit biased by dc current source and the peak detector without low pass filter. The CV converter biased by dc current source provides good signal-to-noise ratio and this setup of the detection circuitry without low pass filter makes it possible to provide short settling time, that is, higher speed of measurement and wide operation range if only a few parameters are adjusted. The key parameters that affect the performance of the detection circuitry are illustrated and computer simulation results are presented. The demonstrated detection circuitry shows linear response from 10 fF to 130 fF at 10 kHz and shows good linearity.

  • PDF

An Experimental investigation on the dependation characteristics of CN/CV cables : dependence on the materials and curing process (배전용 CN/CV 케이블의 절연재료 및 가교방식별 열화특성연구)

  • Kim, H.J.;Choi, Y.H.;Ahn, Y.K.;Kim, K.S.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.969-972
    • /
    • 1992
  • It is shown that the ac breakdown strength, treeing phenomena, oxidation level, and crystallinity of unaged and aged distribution CV cables vary with XLPE insulations (characterizing anti-oxidation) and curing process. The maximum size of bow-tie tree in insulation influenced on the decrease of ac breakdown strength and the increase of oxidation level and crystallinity of XLPE according to aging time lead to increase the size and density of bow-tie trees.

  • PDF

An Acoustical Study of English CV Syllables (영어 CV음절의 음향적 특성 고찰)

  • Yang, Byung-Gon
    • Speech Sciences
    • /
    • v.13 no.4
    • /
    • pp.127-140
    • /
    • 2006
  • This study examined acoustic characteristics of 900 CV syllables produced by five English native speakers. Those target syllables were produced between the syllable /ba/ twenty times. The syllables were segmented and normalized by the maximum intensity value of each syllable and were divided into consonant or vowel sections by a few visible acoustic criteria. Intensity values were collected at 100 relative time points per syllable. Also, cumulative intensity values and consonant and vowel durations along with the ratio of a consonant to each syllable were measured using Praat scripts. Results showed as follows: Firstly, the consonantal section amounted to a quarter of the syllable in terms of both the cumulative intensity and duration. Secondly, the consonantal ratio by the cumulative intensity was similar to that by the duration. Finally, the sum of the cumulative intensity values in each syllable partially coincided with the consonant order by the current sonority scale. Further studies would be desirable on more reliable acoustical measurements and sophisticated perceptual experiments on the English syllables.

  • PDF

A study on the characteristics of deterioration in 6.6kV CV cable (6.6kV CV케이블의 경년열화 특성연구)

  • Kim, K.H.;Sun, J.H.;Kim, Y.B.;Cho, Y.O.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.636-639
    • /
    • 1993
  • This paper is discribed the results of insulation characteristic tests that are DC leakage current, test, tan${\delta}$ test, AC breakdown test and observation of tree in the used 6.6kV CV cables. In the correlation of these tests, the tan${\delta}$ test stands for the main deterioration factor of cable insulation.

  • PDF

A 6.78 MHz Constant Current and Constant Voltage Wireless Charger for E-mobility Applications (E-모빌리티 응용을 위한 6.78MHz 정전압 정전류 무선 충전기)

  • Tran, Manh Tuan;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.142-144
    • /
    • 2019
  • Nowadays, multi-MHz wireless power transfer (WPT) system has received a great concern of study due to its desirable characteristics such as user convenience, system compact and better safety as compared to the conventional DC-DC with cord. This paper presents a solution for WPT Lithium Batteries charger with Constant Current (CC) and Constant Voltage (CV) charging process. The proposed system consists of a high frequency class D power amplifier, a pair of PCB coil, transformable high-order resonant network and a full-bridge rectifier. The charger can be implemented CC /CV charging profile thanks to automatic reconfigurable resonant compensator. Therefore, the battery can be fully charged without the help of an additional DC/DC converter. The simulation and 50W-6.78-MHz hardware experimental results are presented to verify the feasibility of the proposed method and to evaluate the performance of the proposed wireless battery charger.

  • PDF

A Study on the Performance Characteristics and Reuse Effect for Recycled Parts of CV Joint and Steering Gear Box in the Vehicles (자동차 중고재생 등속조인트와 스티어링 기어박스의 성능과 활용효과에 대한 연구)

  • 조휘창;박인송
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.199-205
    • /
    • 2002
  • The scale of repair parts market reached 0.1 billion won. Above all, it is remarkable that the automotive insurance business world is paying f3r 40 ~5o% of the whole repair cost. The repair parts consist of a genuine parts, non-genuine parts, recycling used parts. It is the recent trend that recycled parts are more popular than the genuine parts f3r repairing crashed cars due to the cost. Performance of recycled continuous velocity(CV) joints and power steering(PS) gear box as replacement parts was tested and analysed in this study. To examine the durability of the recycled parts, the replaced CV joints and PS gear box after repair were tested and analysed periodically. The results were showed that basic performance of the recycled parts was normal. However the ball cage of CV joints was more frequently damaged than genuine parts. We concluded that a test standard and amendment of related laws for recycled parts is required to get a safe and durable parts.

Characteristic Analysis of Cyclic Voltammetry on a Self-Assembled Mono-layer Electrode (자가조립 단층 전극에 대한 순환전위법의 특성해석)

  • Cho, Hana;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.4
    • /
    • pp.217-224
    • /
    • 2013
  • In this paper, we have investigated the characteristics of cyclic voltammetry of a self-assembled mono-layer(SAM) electrode which was modified by 3-Mercaptopropionic acid (3-MPA) on gold nanoparticle(AuNP)-deposited electrode. Also, the transport phenomena of electrons and ions around the electrode have been analyzed. The governing equation and its boundary conditions by adopting the semi-infinite diffusion model were formulated for the mass-transfer dominant system. In order to obtain the numerical solutions of cyclic voltammetry(CV) on SAM electrodes, MATLAB program was implemented by applying the explicit finite difference method. Resulting CV program for the SAM-modified electrode was verified in good agreements with the experimental CV results for the 3-MPA on AuNP electrode.

Experiment and Flow Analysis of the Flow Coefficient Cv of a 1 inch Ball Valve for a Thermal Power Plant (화력발전소용 1인치 볼 밸브 유량계수 Cv에 관한 유동해석 및 실험에 관한 연구)

  • Kang, Chang-Won;Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.3
    • /
    • pp.109-115
    • /
    • 2019
  • The purpose of this study was to analyze and test the flow rate of a 1-inch ball valve used in a thermal power plant. To identify the flow-rate characteristics, numerical analysis was conducted and an experimental apparatus of the valve flow rate coefficient was used to compare the flow coefficient Cv values. To determine the internal pressure distribution, the sites of opening ball valves and flow fields were investigated. In particular, a smaller the valve opening resulted in a more complicated the flow field of the ball. The valve flow characteristic test showed that the Cv value and flow rate increased with increasing valve-opening rate and the secondary function was performed. The pressure drop increased as the valve opening rate decreased. In addition, the experimental results for the flow analysis are similar to the numerical analysis results.