• Title/Summary/Keyword: CT values

Search Result 685, Processing Time 0.026 seconds

Measurement of Pancreatic Fat Fraction by CT Histogram Analysis to Predict Pancreatic Fistula after Pancreaticoduodenectomy

  • Wonju Hong;Hong Il Ha;Jung Woo Lee;Sang Min Lee;Min-Jeong Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.599-608
    • /
    • 2019
  • Objective: To evaluate the effectiveness of computed tomography (CT) Hounsfield unit histogram analysis (HUHA) in postoperative pancreatic fistula (PF) prediction. Materials and Methods: Fifty-four patients (33 males and 21 females; mean age, 65.6 years; age range, 37-89 years) who had undergone preoperative CT and pancreaticoduodenectomy were included in this retrospective study. Two radiologists measured mean CT Hounsfield unit (CTHU) values by drawing regions of interest (ROIs) at the level of the pancreaticojejunostomy site on preoperative pre-contrast images. The HUHA values were arbitrarily divided into three categories, comprising HUHA-A ≤ 0 HU, 0 HU < HUHA-B < 30 HU, and HUHA-C ≥ 30 HU. Each HUHA value within the ROI was calculated as a percentage of the entire area using commercial 3-dimensional analysis software. Pancreas texture was evaluated as soft or hard by manual palpation. Results: Fifteen patients (27.8%) had clinically relevant PFs. The PF group had significantly higher HUHA-A (p < 0.01) and significantly lower mean CTHU (p < 0.01) values than those of the non-PF group. The HUHA-A value had a moderately strong correlation with PF occurrence (r = 0.60, p < 0.01), whereas the mean CTHU had a weak negative correlation with PF occurrence (r = -0.27, p < 0.01). The HUHA-A and mean CTHU areas under the curve (AUCs) for predicting PF occurrence were 0.86 and 0.65, respectively, with significant difference (p < 0.01). The HUHA-A and mean CTHU AUCs for predicting pancreatic softness were 0.86 and 0.64, respectively, with significant difference (p < 0.01). Conclusion: The HUHA-A values on preoperative pre-contrast CT images demonstrate a strong correlation with PF occurrence.

Comparison of Target Localization Error between Conventional and Spiral CT in Stereotactic Radiosurgery

  • Kim, Jong-Sik;Ju, Sang-Kyu;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.20-25
    • /
    • 2000
  • The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.

  • PDF

Surface Extraction from Multi-material CT Data

  • Fujimori, Tomoyuki;Suzuki, Hiromasa
    • International Journal of CAD/CAM
    • /
    • v.6 no.1
    • /
    • pp.81-87
    • /
    • 2006
  • This paper describes a method for extracting surfaces from multi-material CT (Computed Tomography) data. Most contouring methods such as Marching Cubes algorithm assume that CT data are composed of only two materials. Some extended methods such as [3, 6] can extract surfaces from the multi-material (non-manifold) implicit representation. However, these methods are not directly applicable to CT data that are composed of three or more materials. There are two major problems that arise from fundamentals of CT. The first problem is that we have to use n(n-1)/2 threshold values for CT data contains n materials and select appropriately one threshold value for each boundary area. The second is that we cannot reconstruct only from CT data in which area three or more materials are adjacent each other. In this paper, we propose a method to solve the problems by using image analysis and demonstrate the effectiveness of the method with application examples construct polygon models from CT data of machine parts.

Comparison of Doppler and CT Angiography as a Predictor of Healing Diabetic Foot Ulcers (당뇨발 치유 가능성의 예측을 위한 도플러와 CT 혈관조영술의 비교)

  • Park, Doug-John;Kim, Hyon-Surk;Han, Seung-Kyu;Kim, Hee-Young;Chun, Kyung-Wook;Kim, Woo Kyung
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.495-500
    • /
    • 2008
  • Purpose: Adequate tissue oxygenation is considered as an essential factor for wound healing. In the non-diabetic population, an uncompromised macrocirculation generally leads to adequate tissue oxygenation. On the contrary, the macrocirculation in diabetic patients may not correlate with tissue oxygenation because of structural changes in the capillary basement membrane. Nevertheless, many medical professionals in Korea rely on macrocirculation evaluation when predicting wound healing potential of the diabetic ulcers. The purpose of this study is to compare reliability of two common macrocirculation assessment methods, Doppler probing and CT angiography, on tissue oxygenation in diabetic foot patients. Methods: Doppler and CT angiography scores were given according to the patency of the anterior and posterior tibial arteries. Tissue oxygenation was measured by transcutaneous partial oxygen tension($TcpO_2$). Doppler and CT angiography scores were statistically analyzed against $TcpO_2$ values. Sixty-eight diabetic foot ulcer patients were included in this study. Results: The test was carried out on Doppler score and $TcpO_2$ variables displayed a p-value of 0.0202, and concluded that the two variables were statistically dependent. The test used to determine for linear trends between Doppler scores and $TcpO_2$ variables displayed a p-value of 0.0149, displaying statistical linear trend between the two variables. On the contrary, the tests between CT angiography scores and $TcpO_2$ variables showed p-values of 0.1242 and 0.6590, that means no correlation between CT angiography and $TcpO_2$ scores. Conclusion: Doppler probing is more reliable than CT angiography in predicting tissue oxygenation of diabetic foot ulcers.

Study of bony trabecular characteristics using bone morphometry and micro-CT (골형태분석법과 micro-CT를 이용한 골소주 특성에 대한 연구)

  • Song, Young-Han;Lee, Wan;Lee, Chang-Jin;Ji, Jung-Hyun;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose : The research was done to investigate the effectiveness of 2D bony morphometry and microstructure of micro-computed tomography (micro-CT) on the osteoporotic bony change. We performed the bone morphometric analysis of proximal femur in ovariectomized rabbits with BMD and micro-CT examination. Materials and Methods : Twenty-one female (Newzealand, about 16 weeks old, 2.9-3.4kg) rabbits were used. Three rabbits were sacrificed on the day when experiment began (Baseline). The remaining 18 rabbits were divided into two groups. One group was ovariectomized bilaterally (OVX) and the other animals were subjected to sham operation (Sham). Bone specimens were obtained from the right and left femur of sacrificed rabbits. At intervals of 1, 2, 3, 5, 6 months respectively, BMD tests were performed on the proximal femur by using PIXlmus 2 (GE Lunar Co. USA), 2-dimensional bone morphometric analysis by custome computer program and 2D/3D bone structure analysis by micro-CT (Skyscan 1072, Antwerpen, Belgium). Statistical analysis was carried out for the correlation between bone morphometry, micro-CT and BMD Result : BV/TV, Tb.Th, Tb.N of micro-CT parameters showed higher values in sham group than OVX group. N.Nd/Ar.RI, N.NdNd, N.NdTm, N. TmTm, PmB/Ar.RI, 3-D BoxSlope of 2D morphometric parameters showed higher values in Sham group than OVX group. The micro-CT parameters of Tb.Sp, Tb.N were statistically significant correlated with BMD respectively. Several 2D morphometric parameters were statistically significant correlated with BMD respectively. Conclusion : Several parameters of 2D bony morphometry and micro-CT showed effective aspects on the osteoporotic bony change.

  • PDF

Correlation Analysis of between Patient and Equipment Factors and Radiation Dose in Chest Low Dose and Abdominal Non-contrast CT (흉부 저선량 및 복부 비조영 CT 검사에서 환자 및 장비 인자와 선량과의 상관관계 분석)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.117-123
    • /
    • 2021
  • This paper is to establish a basis for a dose reduction strategy by confirming correlations with the factors that may affect the radiation dose based on the dose records in low-dose chest CT and abdominal non-contrast CT. In order to find out the causes of unnecessary exposure, the correlation between seven factors (age, gender, height, weight, BMI, patient status [inpatient and outpatient], and use of dose modulation) and CT dose were identified. Logistic regression was used as the statistical analysis for correlation verification. In the low dose chest CT, as the higher values of height and BMI and dose modulation off were associated with lowering the risk exceeding Diagnostic Reference Levels(DRL) (odds ration<1, p<0.05). However, as woman compared to man and the higher values of weight were associated with highering the risk exceeding DRL (odds ration>1, p<0.05). In the abdomen CT, as dose modulation off were associated with lowering the risk exceeding DRL (odds ration<1, p<0.05). Therefore It is necessary to conduct research on the relationship between various factors affecting radiation exposure and patient radiation dose for reducing the dose.

CT Fractional Flow Reserve for the Diagnosis of Myocardial Bridging-Related Ischemia: A Study Using Dynamic CT Myocardial Perfusion Imaging as a Reference Standard

  • Yarong Yu;Lihua Yu;Xu Dai;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.1964-1973
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of CT fractional flow reserve (CT-FFR) for myocardial bridging-related ischemia using dynamic CT myocardial perfusion imaging (CT-MPI) as a reference standard. Materials and Methods: Dynamic CT-MPI and coronary CT angiography (CCTA) data obtained from 498 symptomatic patients were retrospectively reviewed. Seventy-five patients (mean age ± standard deviation, 62.7 ± 13.2 years; 48 males) who showed myocardial bridging in the left anterior descending artery without concomitant obstructive stenosis on the imaging were included. The change in CT-FFR across myocardial bridging (ΔCT-FFR, defined as the difference in CT-FFR values between the proximal and distal ends of the myocardial bridging) in different cardiac phases, as well as other anatomical parameters, were measured to evaluate their performance for diagnosing myocardial bridging-related myocardial ischemia using dynamic CT-MPI as the reference standard (myocardial blood flow < 100 mL/100 mL/min or myocardial blood flow ratio ≤ 0.8). Results: ΔCT-FFRsystolic (ΔCT-FFR calculated in the best systolic phase) was higher in patients with vs. without myocardial bridging-related myocardial ischemia (median [interquartile range], 0.12 [0.08-0.17] vs. 0.04 [0.01-0.07], p < 0.001), while CT-FFRsystolic (CT-FFR distal to the myocardial bridging calculated in the best systolic phase) was lower (0.85 [0.81-0.89] vs. 0.91 [0.88-0.96], p = 0.043). In contrast, ΔCT-FFRdiastolic (ΔCT-FFR calculated in the best diastolic phase) and CT-FFRdiastolic (CT-FFR distal to the myocardial bridging calculated in the best diastolic phase) did not differ significantly. Receiver operating characteristic curve analysis showed that ΔCT-FFRsystolic had largest area under the curve (0.822; 95% confidence interval, 0.717-0.901) for identifying myocardial bridging-related ischemia. ΔCT-FFRsystolic had the highest sensitivity (91.7%) and negative predictive value (NPV) (97.8%). ΔCT-FFRdiastolic had the highest specificity (85.7%) for diagnosing myocardial bridging-related ischemia. The positive predictive values of all CT-related parameters were low. Conclusion: ΔCT-FFRsystolic reliably excluded myocardial bridging-related ischemia with high sensitivity and NPV. Myocardial bridging showing positive CT-FFR results requires further evaluation.

Estimate of Radiation Doses in MDCT Using Patient Weight (MDCT 검사에서 환자 체중을 이용한 선량 평가)

  • Kwon, Seong-Ohk;Dong, Kyung-Rae;Kweon, Dae-Cheol;Goo, Eun-Hoe;Choi, Ji-Won;Chung, Woon-Kwan
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.246-252
    • /
    • 2010
  • The purpose of this study provides measurements of radiation dose from MDCT of head, chest, abdomen and pelvic examinations. A series of dose quantities that are measured of patient weight to compare the dose received during MDCT examinations. Data collected included: weight together with CT dose descriptors, volume CT dose index (CTDIvol) and dose length product (DLP). The effective dose was also estimated and served as collective dose estimation data. Data from 1,774 adult patients attending for a CT examination of the head (n=520) or chest (n=531) or abdomen (n=724) was obtained from spiral CT units using a same CT protocol. Mean values of CTDIvol was a range of 48.6 mGy for head and 6.9, 10.5 mGy for chest, abdomen examinations, respectively. And mean values of DLP was range of 1,604 $mGy{\cdot}cm$ for head, 250 $mGy{\cdot}cm$ for chest, 575 $mGy{\cdot}cm$ for abdomen examinations, respectively. Mean effective dose values for head, chest, abdominal CT were 3.6, 4.2, and 8.6 mSv, respectively. The degree of CTDIvol and DLP was a positive correlation with weight. And there was a positive correlation for weight versus CTDIvol ($r^2$=0.62), DLP ($r^2$=0.694) in chest. And head was also positive correlation with weight versus CTDIvol ($r^2$=0.691), DLP ($r^2$=0.741). We conclude that CTDIvol and DLP is an important determinant of weight within the CT examinations. The results for this study suggest that CT protocol should be tailored according to patient weight.

Head & Neck CT Scan Image Evaluation for Implant Surgery Patients (임플란트 시술환자에 대한 두경부 CT검사 영상 평가)

  • Hyung-Seok Hwang;Hyung-Seok Hwang;In-Chul Im
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.843-849
    • /
    • 2023
  • This study attempted to determine the optimal algorithm after quantitatively analyzing noise, SNR, and CNR measurements by reconstructing four algorithms (Standard, Soft, Bone, and Detail) from head and neck CT images of patients who underwent implant surgery. As an analysis method, pixel values were calculated through the region of interest in the reconstructed image using the Image J program. For noise, SNR, and CNR, the region of interest was measured at the location of the pharynx, masseter muscle, and parotid gland in the image, and the mean and SD values were obtained. The values of SNR and CNR were calculated based on the given formula. As a result, the standard algorithm showed the lowest noise and the highest SNR. CNR was highest in the Soft algorithm, but showed no significant difference from the Standard algorithm. Therefore, it is believed that the Standard algorithm is the optimal algorithm for examining patients wearing intraoral implants in head and neck CT examinations. We hope that the data from this study will be used as basic data for image evaluation in head and neck CT examinations, and that the quality of images will be further improved through various algorithm changes. It is believed that this will be an opportunity to do so.

Correlation of CT Perfusion Images with VEGF Expression in Solitary Brain Metastases

  • Zhang, Jian-Hua;Wang, Ming-Sheng;Pan, Hai-Hong;Li, Shu-Feng;Wang, Zhong-Qiu;Chen, Wang-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1575-1578
    • /
    • 2012
  • Objectives: To obtain permeability surface (PS) values using multi-slice helical CT perfusion imaging and to evaluate the spatial distribution correlation between PS values and vascular endothelial growth factor (VEGF) expression in solitary brain metastases. Methods: Imaging was performed on 21 patients, PS values being calculated from the central, border and peripheral parts of tumours. VEGF expression was determined by immunohistochemical staining. Results: Rim enhancement was found in 16 cases, the border of the tumour featuring PS elevation with high VEGF expression in 13 cases. In the 5 cases with nodular enhancement, the border and the central part had high permeability and VEGF expression was high in all cases, the correlation being significant (P<0.01). Conclusion: VEGF expression in brain metastases positively correlates with PS values from CT perfusion imaging, so that the latter can be used in the surveillance of angiogenic activity in brain metastases.