• 제목/요약/키워드: CT scan and reconstruction

검색결과 111건 처리시간 0.023초

Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구 (Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System)

  • 윤한식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

안와파열골절의 수술결과 평가에서 두 단면의 CT영상 필요성 (Need of Two Planes of CT Scan for Evaluation of Orbital Blowout Fracture Reconstruction)

  • 이수향;범진식;김양우
    • Archives of Plastic Surgery
    • /
    • 제32권2호
    • /
    • pp.194-198
    • /
    • 2005
  • In many reports on the reconstruction of an orbital blowout fracture, CT(computed tomography) imaging has been used for postoperative evaluation. However, in most cases, only one plane of the CT scan was presented, which may not be sufficient for accurate evaluation. This study reviewed the CT scans presented in the related 49 articles (56 cases), and investigated our patients (150 cases) to investigate where were the most frequent unfavorable reconstructions, and to determine which planes should be presented for accurate evaluation. One plane of the CT scan was presented in 70% of the cases. On the other hand, 30% of the cases presented two planes of the CT scans. In our cases, the most prevalent sites for an unfavorable reconstruction were the posterior portion of the inferior wall, and the posterior and the inferior portion of the medial wall. In order to accurately evaluate an orbital wall reconstruction, at least two planes of a CT scan are needed. For an inferior wall evaluation, both the middle and the posterior planes of the coronal section or both the coronal and the sagittal sections are necessary. In addition, for the medial wall evaluation, both the axial and the coronal sections or both the middle and the posterior planes of the coronal section are required.

CT 스캔 영상재구성과 개인용 컴퓨터를 이용한 영상 재형성과의 비교에 관한 연구 (COMPARISON OF IMAGE REFORMATION USING PERSONAL COMPUTER WITH CT SCAN RECONSTRUCTION)

  • 정기훈;김은경;김상준
    • 치과방사선
    • /
    • 제24권2호
    • /
    • pp.361-368
    • /
    • 1994
  • Radiographic planning is needed for implant placement in order to determine implant length, jaw bone volume, anatomical stucture and so on. Radiographic examination includes conventional radiography, conventional tomography and CT scan. The most accurate mesurement can be obtained from CT scan. For the cross-sectional view of mandible, CT scan reconstruction is generally needed. But the cross-sectional view of mandible can be reformed by personal computer. This study was performed to examine the clinical usefulness of reformed image using personal computer in comparison with CT scan reconstructed image. CT axial slices of 4 mandibles of 4 volunteers were used. Digital imaging system was composed of Macintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quick Capture frame grabber board and 'NIH Image' program. Seven reconstructed cross-sectional images within CT machine(CT group) were obtained. And seven reformed cross-sectional images(PC group) after digitization of CT axial slices into the personal computer were obtained. PC group was compared with CT group in the objective and subjective aspects. The results were as follow: 1. Measurement of mandibular height & width in both group showed insignificant difference(P>0.05). 2. Subjective assessment of the mandibular canal in both group showed insignificant difference(P>0.05). 3. Image reformation using personal computer could provide panoramic view, which could not be obtained in CT scan reconstruction.

  • PDF

흉부CT 검사 시 HRCT 영상 재구성의 유용성 (Usefulness Evaluation of HRCT using Reconstruction in Chest CT)

  • 박성민;김긍식;강성민;유병규;이기배
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법 (An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

Assessment of Breast Volume Change after Transverse Rectus Abdominis Myocutaneous Flap

  • Park, Sang Uk;Shim, Jeong Su
    • Archives of Plastic Surgery
    • /
    • 제39권6호
    • /
    • pp.631-635
    • /
    • 2012
  • Background The evaluation of a breast after breast reconstruction depends on a surgeon's subjective criteria. We used computed tomography (CT) scans to obtain an objective evaluation of the postoperative results by measuring the breast volume of patients who had undergone breast reconstruction using pedicled transverse rectus abdominis myocutaneous (TRAM) flaps. This research will help in the objective postoperative evaluation of reconstructed breasts, and also in the preoperative flap size designs. Methods A total of 27 patients underwent breast reconstruction using pedicled TRAM flaps after mastectomy from September 2007 to July 2010. Of these, 10 patients who were followed up and underwent CT scans 2 or more times during the follow-up period were included in this study. We evaluated the change in breast volume over time using CT scans, and the interval breast volume change between CT scans. Results All of the 10 patients' reconstructed breasts showed a volume decrease over time. The breast volume changes in the intervals between CT scans were as follows: 5.65% decrease between the first CT and second CT scan, 2.3% decrease between the second CT and third CT scan, (statistically significant) and 1.89% decrease between the third CT and forth CT scan. (not statistically significant). Conclusions This research shows the possibility of objectively evaluating the postoperative breast volume changes. The findings will be helpful in designing the size of TRAM flaps to use on defects after mastectomy. Based on these results, we should also closely observe the reconstructed breast volume for at least 2 years.

동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성 (Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

3D CT Image Processing for 3D Printed Auricular Reconstruction of Unilateral Microtia Patient

  • Roh, Tae Suk;Yun, In Sik
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권2호
    • /
    • pp.80-82
    • /
    • 2014
  • Purpose Microtia is congenital anomaly of external ear and the reconstruction method for the external ear of microtia patient was based on autogenous costal cartilage framework. The application of 3D printing technique in medical science has made more possibility of human tissue restoration, and we tried to apply this technique in auricular reconstruction field. Materials and Methods As for unilateral microtia patient, the contralateral side ear is normal and reconstructive surgeon tried to mimic it for reconstruction of affected ear. So, we obtained facial CT scan of microtia patient and made mirror image of normal side ear. Moreover, to make the 3D scaffold based on the mirror image of normal ear and to apply this scaffold for the auricular reconstruction surgery, we included auriculocephalic sulcus and anterior fixation part. Results We could successfully obtain mirror image of normal ear, auriculocephalic sulcus and anterior fixation part for 3D scaffold printing. Conclusions Using this CT image processing and 3D printing technique, we will be able to make the scaffold for auricular reconstruction of unilateral microtia patient, and perform auricular reconstruction in near future.

Head & Neck 환자의 방사선 치료시 Metal Artifact의 감소를 위한 Gantry Tilt Scan의 유용성 평가 (Evaluation of using Gantry Tilt Scan to Head & Neck of Patients during Radiation Therapy for Reduction of Metal Artifact)

  • 이충환;윤인하;홍동기;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.85-95
    • /
    • 2010
  • 목 적: 두경부 환자의 CT simulation시 metal artifact가 발생하여 영상의 질 저하와 선량계산의 오차를 유발 할 수 있어 metal artifact를 줄이기 위한 gantry tilt scan의 유용성을 평가하고자 한다. 대상 및 방법: Metal artifact를 줄이기 위하여 $20^{\circ}$ gantry tilt scan하여 $0^{\circ}$로 재구성한 이미지를 획득하였다. AAPM CT performance Phantom을 이용하여 CT number를 비교 분석하고, 아크릴 팬텀을 이용하여 체적의 일치여부를 확인하였다. Metal artifact에 의한 영향을 평가하기 위해 Intensity volume Histogram (IVH)을 통한 CT number의 균질성 및 Dose Volume histogram (DVH)을 통한 선량평가를 시행하였다. 결 과: CT number와 체적의 비교에서는 차이가 0.5% 이하로 나타났다. IVH를 비교 분석결과 gantry tilt scan에서 artifact에 의한 영향이 감소되어 CT number의 균질도가 향상되고, DVH 비교결과는 양쪽 이하선의 0.2~6%의 평균선량 오차를 감소시켰다. 결 론: Head & Neck 방사선치료 시 metal artifact 때문에 체표윤곽의 구별이 어렵고 선량의 오차가 발생한다. Gantry tilt scan을 이용하면 정확한 조직의 묘사가 가능하고, CT number 균질도가 향상되어 선량의 오차를 줄일 수 있었다. Gantry tilt scan 은 Head & Neck 방사선치료 시 정확한 방사선치료에 매우 유용함을 확인하였다.

  • PDF

고급 모델링 반복 재구성법(ADMIRE)이 CT 영상의 화질에 미 치는 영향: 흉부 비조영 CT에서 (The Effect of Advanced Modeling Iterative Reconstruction(ADMIRE) on the Quality of CT Images : Non-contrast CT in Chest)

  • 이상헌;이효영
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.159-168
    • /
    • 2019
  • 흉부 CT스캔에서 공기, 지방, 근육, Background의 HU, 잡음 그리고 신호 대 잡음비의 변화를 측정해 영상 화질에 미치는 지멘스 ADMIRE(Advanced Modeled Iterative Reconstruction)의 영향을 조사했다. 실험 결과에 따르면 ADMIRE Strength가 커질수록 잡음은 감소하고 신호는 증가하여, 결론적으로 신호 대 잡음비는 증가하는 것으로 나타났다. ADMIRE는 기존 영상 재구성 알고리즘인 FBP와 비교하여 잡음을 28~61%까지 줄일 수 있으며, 신호 대 잡음비는 16~100%까지 향상시킨다.