• Title/Summary/Keyword: CT Contents

Search Result 219, Processing Time 0.025 seconds

Development of Classification System Applied Particularity Culture Contents (문화콘텐츠 특수성을 반영한 문화기술(CT) 분류체계 연구)

  • Kim, Hyoyoung;Park, Jin Wan
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.5
    • /
    • pp.183-190
    • /
    • 2013
  • In this study, we propose a new CT classification system which is essential factor for strengthening competitiveness of culture contents and technical assistance of convergence contents. For this, we drew particularity of culture contents by reviewing concept and current state of CT. And also we drew problems of existing CT classification systems and implications for applying to future CT classification system by systematic analysis of existing CT classification systems. Through this series of process we developed a new CT classification system applied particularity of culture contents. The suggested CT classification system can embrace all kind of technologies related to all steps of value chain-planning, manufacturing/production, distribution, service- of culture contents. And it has significance having flexibility for government investigation and applying the law and more realistic for industrial site by restructuring of middle classification level.

An Exploratory Study on the Demand & Supply to Senior friendly industry to Culture Contents Technology(CT) R&D (문화콘텐츠기술(CT) R&D 연계 고령친화산업의 수요와 공급에 관한 탐색적 연구)

  • Kim, Yeon-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3848-3855
    • /
    • 2009
  • Many social and environmental changes emerged by the increasing of the number of the aged to entrance the aged society. This study explored the current supply status on Contents Technology R&D(research and development) of CT ministries and market policies(senior friendly industry) targeting to elderly consumers and the needs and demand of elderly generation to knowledge information technology. In, 2008, Ministries announced the sixth category of CT R&D's fundamental planning. The 'public culture service' to elderly and handicapped person is one of CT R&D category. This study investigated the information technology participation(internet participation rate, blog and internet cafe commitment) and contents technology to the elderly. The research indicated the desired needs of elderly consumers are creativity contents, emotional & experience and communication needs. These three factors of CT R&D to elderly consumers meets the needs non-game factors such as health, economic stability and information seeking in entertainment game.

Computed tomographic features of gastric and esophageal content in dogs undergoing CT myelography and factors influencing the presence of esophageal fluid

  • Benzimra, Caroline;Cerasoli, Ilaria;Rault, Delphine;Chalvet-Monfray, Karine;Cauvin, Eddy;Couturier, Laurent;Gatel, Laure
    • Journal of Veterinary Science
    • /
    • v.21 no.6
    • /
    • pp.84.1-84.11
    • /
    • 2020
  • Background: Gastroesophageal reflux (GER) has been reported to be a common finding in dogs under general anesthesia. Objectives: The aim of this retrospective study was to assess the esophageal and gastric contents in a population of dogs undergoing computed tomographic myelography (myeloCT) examination and to evaluate the factors influencing the presence of esophageal fluid (gastric content, duration of anesthesia, body position, and intrinsic factors). Methods: Esophageal and gastric contents of 83 non-brachycephalic dogs were retrospectively assessed based on plain and myelo-CT scans. Age, weight, breed, sex, and the time between the 2 computed tomography [CT] scans were included. Results: Esophageal fluid was present in 19% (16/83) of the animals, and 14% (12/83) and 46% (37/83), respectively, had fluid or food material in their stomachs. The frequency of observing esophageal fluid on myelo-CT scans was significantly increased compared with plain CT scans (p = 0.006). The presence of gastric fluid was significantly associated with an increased frequency of observing esophageal fluid compared to other gastric contents (p = 0.049; odds ratio, 3.1). The presence of esophageal fluid was not correlated with alimentary gastric contents (p = 0.17). Increased body weight and duration of anesthesia were significantly associated with an increased frequency of observing esophageal fluid (p = 0.022, p = 0.021). Conclusions: Unlike alimentary gastric contents, fluid gastric contents were correlated with the presence of esophageal fluid upon myelo-CT. The observation of fluid in the esophagus may be consistent with GER. This study provides data additional to pH monitoring studies of GER and may support previous studies recommending shorter pre-anesthetic fasting periods in dogs.

A Study for CT Technology Valuation Methods (CT기술 가치평가에 관한 연구)

  • Ham, Hyung-Bum;Lee, Yang-Sun;Kim, Ki-Hoon;Jung, Woo-Chai
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.8
    • /
    • pp.1086-1094
    • /
    • 2006
  • The CT is all relation knowledge and technology which are applied to make the culture contents. Recently demand regarding the CT is increasing rapidly with a great growth and high technology of culture contents industry. In this paper we suggest a CT technology valuation model for promoting R & D results and technical diffusion of the CT. Also, It is shown how to derive a value of the CT using simulation. For it, we study a classification and distinctive characteristics of the CT. And this paper reviews the methods of technology valuation that have been developed by valuation specialists.

  • PDF

Particle Spacing Analysis of Frozen Sand Specimens with Various Fine Contents by Micro X-ray Computed Tomography Scanning (Micro X-ray CT 촬영을 통한 동결 사질토 시료의 세립분 함유량에 따른 입자간 거리 분석)

  • Chae, Deokho;Lee, Jangguen;Kim, Kwang-Yeom;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.1
    • /
    • pp.31-35
    • /
    • 2017
  • The mechanical characteristics of frozen sand greatly depend on the frozen temperature and the fine contents according to the previous study by Chae et al. (2015). There are two hypotheses to explain this experimental results; one is the unfrozen water contents greatly affected by the fine contents and frozen temperature and the other is the sand particle spacing greatly affected by the pore-ice. To evaluate the latter hypothesis, the micro X-ray CT scan was performed. The micro X-ray CT scanning, one of the actively performed interdisciplinary research area, has a high resolution with micrometer unit allows to investigate internal structure of soils. In this study, X-ray CT technique was applied to investigate the effect of the frozen temperature and fine contents on the sand particle minimum and average spacing with the developed image processing techniques. Based on the spacing analysis, the frozen temperature and fine contents have little influence on the sand particle spacing in the frozen sand specimens.

A Study on Senior friendly function Game Industry and Culture Contents Technology(CT) R&D development process. (고령친화 기능성 게임산업과 문화콘텐츠 기술(CT) R&D 발전랑안의 모색)

  • Kim, Yeon-Jeong;Park, Hyun-Sik
    • Journal of Digital Convergence
    • /
    • v.7 no.4
    • /
    • pp.57-65
    • /
    • 2009
  • This study explored the current supply status on Contents Technology R&D(research and development) and friendly function Game Industry targeting to elderly consumers. The game contents including the functional components are categorized the sixth category of CT R&D's fundamental planning. The function game targeting to elderly focused on emotional and physical recovering to barrier, user friendliness, simplicity and certainty of game performance. The purpose of game participation are health, well-being, psychological wellness and communication. The functional game consisted of various version procedure by socio-demographic, the accessibility to game media and device.

  • PDF

Type of medical institutions according to the Equipment List and inspection fee computed tomogaphy relationship between (의료기관 종별에 따른 전산화단층촬영장비 보유현황과 검사료간의 관계)

  • Kim, Min-Cheol;Lim, Cheong-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.195-196
    • /
    • 2011
  • 1996년 이후부터 전산화단층촬영 검사가 건강보험급여대상이 되면서 이용률과 보급률이 더욱 증가되고 있으며 검사범위의 확대, 검사시간의 단축, 반복검사의 용이성, 이용의 편리성, 결과의 신뢰성, 장치의 구조적인 요소 및 검사 시행 횟수의 증가 등으로 검사량이 증가되고 있는 실정이다. CT 검사 건수의 증가요인으로 새로운 CT장비의 개발과 더불어 급격한 장비도입 증가 추세가 있으므로 이에 본 연구에서는 의료기관 종별 및 시기별 CT 장치 보유현황과 검사료간의 관계를 파악하였다. CT 장비는 병원급은 증가하고 있는 추세이나 의원급은 감소하고 있는 것으로 나타났다. CT진료비 청구는 80%이상이 종합전문요양기관과 종합병원에서 청구하는 것으로 나타났다. 이에 본 연구에서는 고가의료영상 진단 장비인 CT의 세대별 발달장비 도입 시기에 따른 우리나라 CT의 현황을 조사 분석하여 제시하여 고가의료장비 수급의 정책수립의 계기 및 기여하고자 한다.

  • PDF

An Influence of Supportive Policy for CT Industry on Innovation Ability of Organization and OSMU of Contents - Focusing on Domestic Animation Industry (CT산업 지원 정책이 조직의 혁신역량과 콘텐츠의 OSMU화에 미치는 영향 - 국내 애니메이션 산업중심으로)

  • Choi, Young-Kwan;Cho, Sung-Sook
    • Journal of Digital Convergence
    • /
    • v.7 no.4
    • /
    • pp.67-80
    • /
    • 2009
  • The research tried to realize the policy which serves Innovation ability for culture-contents producer, and culture-contents producer's Innovation ability which impacts OSMU of contents in the policies of government for vitalizations of culture-contents industry. As a result, we have reached the conclusion that the supportive policies for technology, exports and marketing were effective to strengthen the innovation ability of management of human resource, creation and production area. Also we have found that content's OSMU has been influenced by innovation ability. The implication of this study are followed. First, the policies which are intended to revitalize the culture content industry by government has the effect that are some different ones from the settlement and intention. Second, the production industry of animation do still passive and closed organization management, without the efforts for opened and cooperative management. Therefore, the efforts of government which are more practical and realistic supports to revitalize and based on strategic cooperation of industry.

  • PDF

Case Study of Quality Assurance for MDCT Image Quality Evaluation Using AAPM CT Performance Phantom (AAPM CT 성능 평가용 팬텀을 이용한 전산화단층촬영의 영상 평가를 위한 정도관리 사례 연구)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.7
    • /
    • pp.114-123
    • /
    • 2007
  • The increasing use of computed tomography (CT) as a diagnostic tool creates the need from and efficient means of evaluating the performance of the CT scanner now in use. Accordingly, acceptance testing and quality assurance of CT is of great importance. The aim of this study is to analyze of AAPM CT performance phantom in the CT accreditation program. The modular phantom offers the CT system with which to measure eight performance parameters. The parameters are listed of CT attenuation coefficient of water, noise, uniformity, spatial resolution, contrast resolution, slice thickness (5 and 10 mm), artifacts and alignment. The phantom evaluation was done by two radiologists. The acceptance testing protocol described here in demonstrates the successful of the guidelines for the quality assurance using AAPM CT performance phantom. We need to be upgraded for the CT image quality and make the standard reference of the quality assurance in the CT.