• Title/Summary/Keyword: CT 촬영장치

Search Result 144, Processing Time 0.026 seconds

Treatment of Osteoid Osteoma (유골 골종의 치료)

  • Han, Chung-Soo;Cho, Chang-Hyun;Cho, Young-Lin;Cho, Nam-Su;Lim, Chan-Teak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose : The purpose of the current study was to report the results of curettage and en bloc excision as well as to introduce how to excise the nidus percutaneously with Halo-mill. Material and Methods : Twenty patients(14 men and 6 women) were evaluated, who had operative treatments after diagnosed as osteoid osteoma from March 1990 to January 1998. These patients ranged in age from 7 to 42 years(average: 20.8 years). Locations were 9 femurs, 6 tibias, 2 vertebras, 1 ulna, 1 maxilla and 1 skull. Nine femoral lesions included 5 proximal metaphysis, 2 neck and 2 diaphysis, while 5 tibial lesions included 3 diaphysis, 1 proximal metaphysis and 1 distal metaphysis. We used simple radiography, bone scan, CT and MRI for the accurate diagnosis and localization. As for surgical treatments, while excision and curettage had to need open-exposure of lesion, the percutaneous excision of nidus did not need openexposure : guided Halo-mill into K-wire inserted to nidus under image intensifier. Results : Simple radiography showed that 10 cases had typical nidus and others had only cortical sclerosis. Bone scan was performed at 14 cases and all had hot uptake except one case. We used CT in 10 cases and MRI in 4 cases as diagnostic methods, of which 1 case didn't reveal nidus at CT. Surgical treatment consisted of 6 curettages, 11 excisions, 2 percutaneous excisions with halo-mill and 1 total elbow arthroplasty. We used 7mm sized Halo-mill. During the follow-up period, all patient relieved symptoms and there were no recurrences. All had histologically typical findings except one which had hyperostosis without nidus. Conclusion : Complete removal of the nidus is the most important factor in the treatment. We could excise the nidus percutaneously in 2 cases with the minimal injury to surrounding soft tissues. If we could evaluate the precise location, size of nidus and percutaneous acccesibility, the percutaneous excision of nidus with Halo-mill could be an alternative method as a treatment of osteoid osteoma.

  • PDF

3-Dimensional Dosimetry of Small Field Photon Beam (광자선의 소조사면에서의 3차원적 선량 측정)

  • Jang, Ji-Sun;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • A polymer gel dosimeter was fabricated. A 3-dimensional dosimetry experiment was performed in the small field of the photon of the cyberknife. The dosimeter was installed in a head and neck phantom. It was manufactured from the acrylic and it was used in dosimetry. By using the head and neck CT protocol of the CyberKnife system, CT images of the head and neck phantom were obtained and delivered to the treatment planning system. The irradiation to the dosimeter in the treatment planning was performed, and then, the image was obtained by using 3.0T magnetic resonance imaging (MRI) after 24 hours. The dose distribution of the phantom was analyzed by using MATLAB. The results of this measurement were compared to the results of calculation in the treatment planning. In the isodose curve on the axial direction, the dose distribution coincided with the high dose area, 0.76mm difference on 80%, rather than the low dose area, 1.29 mm difference on 40%. In this research, the fact that the polymer gel dosimeter and MRI can be applied for analyzing a small field in a 3 dimensional dosimetry was confirmed. Moreover, the feasibility of using these for the therapeutic radiation quality control was also confirmed.

Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations (전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질)

  • Cho, Pyong-Kon;Kim, You-Hyun;Choi, Jong-Hak;Lee, Ki-Yeol;Kim, Hyung-Cheol;Kim, Jang-Seob;Shin, Dong-Chul;Lee, Sung-Hyun;Lee, Jun-Hyub;Shin, Gwi-Soon
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.453-460
    • /
    • 2009
  • The purpose of this study was to determine the dose distribution and image quality according to slice thickness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was placed at isocenter and 5, 10, 15, 20, 25 and 30 cm positions from the isocenter in the 12, 3, 6 and 9 o'clock directions. The dose distribution for phantom scan was also measured using CT head and body dose phantom with five holes at the center of the phantom and the positions of the 12, 3, 6 and 9 o'clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the phantom was moved by 5 cm or 10 cm to the 12 o'clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o'clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrease as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector array. The value of CTDIW decreased with increasing BC, but the value decreased 16.6~31.9% in the head phantom scan in air scan and 51.0~64.5% in the body phantom scan. The value of the noise was 3.9~5.9 in the head and 5.3~7.4 in the body except for BC of $2{\times}0.5\;mm$, regardless of the degree of deviation from the iso-center. When a subject was located within the SFOV, the position did not significantly affect image quality even if the subject was out of the center.

  • PDF

Three dimensional analysis of tooth movement using different types of maxillary molar distalization appliances (간접골성 고정원을 이용한 상악 구치부 원심이동 장치 종류에 따른 치아 이동 양상 평가)

  • Kim, Su-Jin;Chun, Youn-Sic;Jung, Sang-Hyuk;Park, Sun-Hyung
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.376-387
    • /
    • 2008
  • Objective: The purpose of this study was to compare the three dimensional changes of tooth movement using four different types of maxillary molar distalization appliances; pendulum appliance (PD), mini-implant supported pendulum appliance (MPD), stainless steel open coil spring (SP) and mini-implant supported stainless steel open coil spring (MSP). Methods: These experiments were performed using the Calorific $machine^{(R)}$ which can simulate dynamic tooth movement. Computed tomography (CT) images of the experimental model were taken before and after tooth movement in 1 mm thicknesses and reconstructed into a three dimensional model using V-works $4.0^{TM}$. These reconstructed images were superimposed using Rapidform $2004^{TM}$ and the direction and amount of tooth movement were measured. Results: The mean reciprocal anchor loss ratio at the first premolar was 17 - 19% for the PD and SP groups. The appliances using mini-implants (MPD or MSP) resulted in less anchorage loss (7 - 8%). On application of a pendulum appliance or MPD, distalization was obtained by tipping rather than by bodily movement. Furthermore, the maxillary second molar tipped distally and bucally. But on application of MSP, distalization was achieved almost by bodily movement. Conclusions: Regarding tooth movement patterns during molar distalization, stainless steel open coil spring with indirect skeletal anchorage was relatively superior to other methods.

The Use of an Iliac Branch Device: Single-Center Study of Endovascular Preservation of Internal Iliac Artery Flow (장골 분지 장치 사용: 내장골동맥 흐름의 혈관내 보존에 대한 단일 기관의 경험)

  • Hyeseung Lee;Jeong-min Lee;Soongu Cho;JungUi Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1339-1349
    • /
    • 2023
  • Purpose To determine the efficacy and safety of iliac branch device (IBD) implantation and to evaluate its limitations based on 7 years of experience in a single center. Materials and Methods This single-center study included patients with bilateral common iliac artery aneurysms (CIAAs). We investigated follow-up CT and reviewed the internal iliac artery (IIA) patency and complications related to IBD. A retrospective analysis was performed and the overall survival rate and freedom from reintervention rate were reported according to the Kaplan-Meier method. Results Of the 38 patients with CIAAs, only 10 (12 CIAAs) were suitable for IBD treatment. Five patients underwent unilateral IBD insertion with contralateral IIA embolization, and three (60%) showed claudication; however, symptoms resolved within 6 months. The 7-year freedom from IBD-related reintervention rate was 77.8%. No procedure-related deaths occurred. Conclusion IBD has good technical success and long-term patency rates; however, anatomical factors frequently limit its application, particularly in Asians. Additionally, unilateral IIA embolization showed relatively mild complications and a good prognosis; therefore, it can be performed safely for anatomically complex aortoiliac aneurysms.

Finite Element Analysis of Wrist Orthosis with 3D Printing (3D 프린트를 통해 제작된 손목 보조기의 유한요소해석)

  • Choi, Hyeun-Woo;Kang, Inyeong;Noh, Gunwoo;Seo, Anna;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.947-953
    • /
    • 2019
  • The purpose of this study was to manufacture a wrist brace using a computerized tomography system, clinical design software (MediACE 3D Program), and 3D printer. After acquiring the Dicom file of the upper limb with a computed tomography, the wrist brace was designed using the MediACE 3D Program to create a "stereolithography" file. The designed wrist brace was printed using a 3D printer. To verify the effectiveness of wrist assistive device manufactured by 3D printing technology, the stress distribution of the pressure and orthosis applied to bone and skin is represented by finite element analysis. It is expected that the wrist brace can be manufactured by reinforcing the part where the damage caused by pressure and breakage of the brace frequently occurs with the result of finite element analysis when producing the wrist brace.

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF

The Comparison of Usefulness between MDCT Angiography and DSA in the Diagnosis of Intracranial Aneurysm (뇌 동맥류 진단에 있어 디지털 감산 혈관조영술과 다중검출기 전산화단층촬영 혈관조영술의 유용성 비교)

  • Khang, Hyun-Soo;Seo, Sun-Youl;Han, Dong-Kyoon;Kwon, Soo-Il;Shim, Su-Jung;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.184-189
    • /
    • 2011
  • The purpose of this study was to compare the image between DSA and MDCT Angiography and to examine whether MDCT Angiography could be useful as a screening test for the diagnosis of cerebral aneurysm in patients who were diagnosed with cerebral aneurysm on DSA. Of patients who were diagnosed with cerebral aneurysm DSA at University Hospital, 194 patients who concomitantly underwent MDCT Angiography were enrolled in the current retrospective study. The methods for analyzing cerebral aneurysm were to analyze the presence of cerebral aneurysm on DSA and MDCT Angiography. In cases in which it exceeded 1, the corresponding cases were classified as narrow-neck aneurysms. In otherwise cases, they were classified as wide-neck aneurysms. Thus, a comparative analysis could be performed to ascertain if cases were narrow-neck or wide-neck aneurysms. As compared with DSA, the sensitivity of MDCT Angiography for cerebral aneurysm was measured to be 97.4%. The degree of consistency between narrow-neck and wide-neck aneurysms was 90.2% and the proportion of undetectable an at MDCT Angiography was 2.54%. mean size was 2.4 mm. It is expected that a non-invasive diagnostic modality for a screening test for cerebral aneurysm, MDCT Angiography might be a very useful regimen as compared with an invasive one, DSA.

Computed Tomographic Simulation of Craniospinal Irradiation (전산화 단층 촬영 장치를 이용한 뇌척수 조사의 치료 계획)

  • Lee CI;Kim HN;Oh TY;Hwang DS;Park NS;Kye CS;Kim YS
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.53-59
    • /
    • 1999
  • The aim of this study is to improve the accuracy of field placement and junction between adjacent fields and block shielding through the use of a computed tomography(CT) simulator and virtual simulation. The information was acquired by assessment of Alderson Rando phantom image using CT simulator (I.Q. Xtra - Picker), determination of each field by virtual fluoroscopy of voxel IQ workstation AcQsim and colored critical structures that were obtained by contouring in virtual simulation. And also using a coronal, sagittal and axial view can determine the field and adjacent field gap correctly without calculation during the procedure. With the treatment planning by using the Helax TMS 4.0, the dose in the junction among the adjacent fields and the spinal cord and cribriform plate of the critical structure was evaluated by the dose volume histogram. The pilot image of coronal and sagittal view took about 2minutes and 26minutes to get 100 images. Image translation to the virtual simulation workstation took about 6minutes. Contouring a critical structure such as cribriform plate, spinal cord using a virtual fluoroscopy were eligible to determine a correct field and shielding. The process took about 20 minutes. As the result of the Helax planning, the dose distribution in adjacent field junction was ideal, and the dose level shows almost 100 percentage in the dose volume histogram of the spinal cord and cribriform plate CT simulation can get a correct therapy area due to enhancement of critical structures such as spinal cord and cribriform plate. In addition, using a Spiral CT scanner can be saved a lot of time to plan a simulation therefore this function can reduce difficulties to keep the patient position without any movements to the patient, physician and radiotherapy technician.

  • PDF

A three-dimensional finite element analysis of obturator prosthesis for edentulous maxilla (무치악 구개결손 환자를 위한 폐쇄장치의 삼차원 유한요소 분석)

  • Song, Woo-Seok;Kim, Myung-Joo;Lim, Young-Jun;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.222-228
    • /
    • 2011
  • Purpose: The purposes of this study were to evaluate the stress distributions and the displacements of obturator for edentulous maxillectomy patients and to compare them with those of complete denture using three-dimensional finite element analysis. Materials and methods: Based on the CT image of edentulous patient, three-dimensional finite element model of edentulous maxillae was constructed. Three-dimensional finite element model of edentulous maxillae with palatal defect was also fabricated. On each model, complete denture and obturator prosthesis were created. Vertical static force of 200 N was applied on the left maxillary premolar and molar region. The von Mises stress values and the displacements of models were analyzed using three-dimensional finite element analysis. Results: Maximum von Mises stress values were recorded in the cortical bones of both models. The von Mises stress value in the complete denture model was 2.73 MPa and 2.69 MPa in the obturator model. High von Mises stress values were also observed on the tissue surface of prosthesis. The maximum value of the displacement in the obturator was higher than that of complete denture. Conclusion: The obturator showed a worse result in terms of stress distribution and displacement than complete denture. In the prosthodontic rehabilitation of edentulous maxillectomy patient accurate impression procedure based on patients'anatomy and application of prosthodontic principle should be considered.