Analysis and Evaluation of Computed Tomography Dose Index (CTDI) of Pediatric Brain by Hospital Size (병원규모별 소아 두부 CT 검사 선량지표 분석 평가)

  • Kim, Hyeonjin;Lee, Hyoyeong;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.503-510
    • /
    • 2016
  • Even though children are exposed to the same amount of radiation, their effective dose amount is higher than those of adults. Therefore, it is very important to reduce the amount of unnecessary radiation exposure because children have a higher radiosensitivity and a smaller body size than adults. In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the Busan regional hospitals, to the national diagnostic reference levels. For this, the pediatric head CT scan was conducted among the CT equipments that were installed in downtown Busan. From 2,043 children 10 years old or less who were referred to the pediatric head CT scan, targeting the 28 CT equipments in the 24 hospitals that transmit dose reports to PACS, were examined retrospectively. As a result, the average value of CTDIvol, computed tomography dose index (CTDI) of infant brain, across the hospital, was 31.18 mGy, with DLP of $444.73mGy{\cdot}cm$, which exceeded the diagnostic reference level. The lower the age, the more management is needed for radiation. However, the reality is that the CT examinations are being conducted with a dose that exceeds the reference level as the age of the aged is exceeded. For this purpose, the study seeks to determine the degree of doses of doses outside the diagnostic reference level and analyze the cause of the excess dose and devise measures to reduce the dose reduction.

Dose Comparison between Fast Low Dose C-arm CT and DSA (Fast Low Dose C-arm CT와 DSA의 선량 비교)

  • Kim, Chan-woo;Kim, Jae-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.613-618
    • /
    • 2020
  • The average dose of Fast Low Dose C-arm CT used during hepatic arterial chemoembolization was compared with the average dose of DSA, and the exposure dose was analyzed by analyzing the average dose for each test technique in the total accumulated dose. 50 patients were randomly selected at our clinic and compared with Fast Low Dose C-arm CT, DAP and Air Kerma of DSA, and the accumulation of four test techniques (DSA, Fast Low Dose C-arm CT, Roadmap, Fluoroscopy) The proportion of dose (DAP, Air Kerma) was analyzed. For statistical comparative analysis, the corresponding sample T test and ANOVA test (post hoc test: Tukey) were performed using the statistical program SPSS 20.0. Fast Low Dose C-arm CT showed statistically significantly lower average dose (DAP, Air Kerma) than DSA. Reducing the number of tests for DSA can reduce the patient's exposure to medical radiation.

A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner (X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구)

  • Jung, Jae-Yong;Lee, Choong-Il;Min, Jeong-Hwan;Kim, Yon-Lae;Lee, Seong-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • In this study, we evaluated the dose response of MAGAT (Methacrylic Acid Gelatin gel and THPC) normoxic polymer gel dosimeters based on the X-ray CT scanner. To perform this study, we determined the proper ratio of the gel composition and acquired X-ray scan parameters. MAGAT gel dosimeters were manufactured using MAA (MethacrylicAcid) and gelatin of various concentration, irradiated up to 20 Gy. We obtained the 20 CT images from the irradiated gel dosimeters by using on a Phillips Brilliance Big Bore CT scanner with the various scan parameters. This CT images were used to determine the $N_{CT}$-dose response, dose sensitivity and dose resolution As an amount of MAA and gelatin were increase, the slope and intercept were increase in each MAGAT gel dosimeter with various concentration of the $N_{CT}$-dose response curve. The dose sensitivity was $0.38{\pm}0.08$ to $0.859{\pm}0.1$ and increased were amount of the MAA was increased or the gelatin was decreased. However, the change of gelatin concentration was very small compare to MAA. The Dose resolution ($D_{\Delta}^{95%}$) varies considerably from 2.6 to 6 Gy, dependent on dose resolution and CT image noise. The slope and dose sensitivity was almost ident verywith the variation of the tube voltage, tube current and slice thickness in the dose response curve, but the noise (standard deviation of averamalg CT number) was decreased when the tube voltage, tube current and slice thickness are increase. The optimal MAGAT polymer gel dosimeter based on the CT were evaluated to determine the CT imaging scan parameters of the maximum tube voltage, tube current and slice thickness (commonly used in clinical) using the composition ratio of a 9% MAA, 8% gelatin and 83% water. This study could get proper composition ratio and scan parameter evaluating dose response of MAGAT normoxic polymer gel dosimeter using CT scanner.

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF

Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol (흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교)

  • Lee, Won-Jeong;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • The purpose of this study was to compare radiation dose and image quality between low-dose (LDP) and standard-dose protocol (SDP). LDP (120 kVp, 30 mAs, 2-mm thickness) and SDP (120 kVp, 180 mAs, 1.2-mm thickness) images obtained from 61 subjects were retrospectively evaluated at level of carina bifurcation, using multi-detector CT (Brilliance 16, Philips Medical Systems). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated at ascending aorta and infraspinatus muscle, from CT number and back-ground noise. Radiation dose from two protocols measured at 5-point using acrylic-phantom, and CT number and noise measured at 4-point using water-phantom. All statistical analysis were performed using SPSS 19.0 program. LDP images showed significantly more noise and a significantly lower SNR and CNR than did SDP images at ascending aorta and infraspinatus muscle. Noise, SNR and CNR were significantly correlated with body mass index (p<0.001). Radiation dose, SNR and CNR from phantom were significant differences between two protocols. LDP showed a significant reduction of radiation dose with a significant change in SNR and CNR compared with SDP. Therefore, exposure dose on LDP in clinical applications needs resetting highly more considering image quality.

Exposure Dose of Thyroid, Breast, and Sexual Gland using a Personal Dosimeter in Multiple CT Examinations (다중 CT 검사 시 개인선량계를 이용한 갑상선, 유방, 생식선의 피폭선량)

  • Kim, Hae-Suk;Kim, Jang-Oh;Lee, Yoon-Ji;Heo, Sung-Hoe;Lee, Chang-Ho;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.345-351
    • /
    • 2020
  • In this study, a dose assessment was conducted on the exposure dose of thyroid, breast and sexual gland using a personal dosimeter in multiple CT examinations currently being conducted in health examinations. The dose assessment was measured by attaching TLD and EPD to the locations of the thyroid, breast and sexual gland during CT examinations of Brain, Brain + C-S, Brain + Low lung, Brain + L-S among CT items. The generated dose of equipment, CTDIvol and DLP, was measured. The study found that effective doses were rated 41.7% higher for thyroid TLD in Brain + C-S CT examinations than for the general public, 156% higher for EPD, 10% for breast EPD in Brain + Low Lung CT examinations, 124.4% higher for reproductive TLD and 339.8% higher for Brain + L-S CT examinations. The CTDIvol and DLP analysis results showed that C-S CTDIvol values were higher than the diagnostic reference levels at 0.6%, Low Lung CTDIvol values at 5.7%, DLP values at 11.8% and L-S CTDIvol values at 1.2%. In order to reduce the exposure dose of patients, indiscriminate examination is reduced and dose limit setting is needed in health examination.

Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols (전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가)

  • Nam, So-Ra;Son, Hye-Kyung;Lee, Sang-Hoon;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation dose for clinical PET/CT protocols in clinical environments using Alderson phantom and TLDs. Radiation doses were evaluated for both Philips GEMINI 16 slice PET/CT system and GE DSTe 16 slice PET/CT system. Specific organ doses with $^{137}Cs$ transmission scan, high quality CT scan and topogram in philips GEMINI PET/CT system were measured. Specific organ doses with CT scan for attenuation map, CT scan for diagnosis and topogram in GE DSTe PET/CT system were also measured. The organs were selected based on ICRP60 recommendation. The TLDs used for measurements were selected for within an accuracy of ${\pm}5%$ and calibrated in 10 MV X-ray radiation field. The effective doses for $^{137}Cs$ transmission scan, high qualify scan, and topogram in Philips GEMINI PET/CT system were $0.14{\pm}0.950,\;29.49{\pm}1.508\;and\;0.72{\pm}0.032mSv$ respectively. The effective doses for CT scan to make attenuation map, CT scan to diagnose and topogram in GE DSTe PET/CT system were $20.06{\pm}1.003,\;24.83{\pm}0.805\;and\;0.27{\pm}0.008mSv$ respectively. We evaluated the total effective dose by adding effective dose for PET Image. The total PET/CT doses for Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan+PET, Topogram+high qualify CT+PET) and GE DSTe PET/CT (Topogram +CT for attenuation map+ PET, Topogram+diagnostic CT+ PET) are $7.65{\pm}0.951,\;37.00{\pm}1.508,\;27.12{\pm}1.003\;and\;31.89{\pm}0.805mSv$ respectively. Further study may be needed to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with good image qualify.

  • PDF

Application of Low-Dose CT for Screening of Lung Disease (폐질환의 선별검사를 위한 저선량 전산화 단층촬영의 적용)

  • Lee, Won-Jeong;Choi, Byung-Soon;Park, Young-Sun;Seon, Jong-Ryul;Bae, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.129-140
    • /
    • 2009
  • As CT has been increasingly used as an accurate screening tool for lung disease, radiation dose becomes an important issue for both radiographers and patients. Many researches have been done for a low-dose CT as a screening tool for early detection of asymptomatic lung diseases. From those studies, it has been reported that chest dose rate from the low-dose CT is considerably lower than from standard CT. The patient dose is determined by scanning parameters such as kVp, mAs, pitch, scan time and the radiation risk of lung in screening examination may not be negligible. Herein, we suggest that Low-dose CT is useful as a screening tool in routine clinical practice on the basis of published articles, but further study is necessary because Low-dose CT has poor sensitivity and specificity for screening early stage of lung cancer according to the results of the studies. This article is to provide a brief overview of the screening examinations by Low-dose CT.

  • PDF

Evaluation of the dose of 16-MDCT and 64-MDCT in case of Coronary Artery CT Angiography using Thermoluminescence Dosimeter (열형광선량계를 이용한 16-MDCT와 64-MDCT의 관상동맥 CT 혈관조영술 시 선량평가)

  • Kim, Sang-Tae;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.336-343
    • /
    • 2010
  • Coronary artery CT angiography has short scanning length, the exposure dose is high. Therefore, it is required to study on the organ dose when using MDCT. We compared the differences between the absorbed dose and effective dose in the major organs assessing the absorbed dose in the major organs by 16-MDCT and 64-MDCT in the subjects with coronary artery CT angiography, the same protocol by 16-MDCT and 64-MDCT. As a result, the great orders of absorbed dose when conducting coronary artery CT angiography had been shown as heart, stomach, liver, pancreas, kidney, spleen, large intestine, lung, small intestine, thyroid gland, ovary, bladder, and orbit with the absorbed dose distribution of $0.538{\pm}0.026(Mean{\pm}SD,\;p<0.05)mGy{\sim}71.316{\pm}4.316mGy$ in 16-MDCT, and heart, stomach, pancreas, spleen, liver, kidney, small intestine, large intestine, lung, thyroid gland, ovary, bladder, and orbit with the absorbed dose distribution of $0.87{\pm}0.01mGy{\sim}115.26{\pm}1.59mGy$ in 64-MDCT, demonstrating some different distributions. The exposed doses to the patient per one time scanning with coronary artery CT angiography were $71.316{\pm}4.316mGy$ in 16-MDCT as the absorbed dose based on the heart and $115.26{\pm}1.59mGy$ in 64-MDCT. The effective doses were 7.41 mSv and 12.11 mSv in 16 and 64-MDCT, respectively. Taking into account the results of brain CT with 2.8 mSv that has comparatively large scanning length and size, facial CT 0.8 mSv, chest CT 5.7 mSv, pelvic CT 7.2 mSv, and abdominal and pelvic CT 14.4 mSv, it is very high considering the scanning length of 13 cm limited to the heart for the scanning range.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.