• 제목/요약/키워드: CR39

검색결과 425건 처리시간 0.027초

Theoretical and experimental serviceability performance of SCCs connections

  • Maghsoudi, Ali Akbar
    • Structural Engineering and Mechanics
    • /
    • 제39권2호
    • /
    • pp.241-266
    • /
    • 2011
  • The Self Compacting Concrete, SCC is the new generation type of concrete which is not needed to be compacted by vibrator and it will be compacted by its own weight. Since SCC is a new innovation and also the high strength self compacting concrete, HSSCC behavior is like a brittle material, therefore, understanding the strength effect on the serviceability performance of reinforced self compacting concretes is critical. For this aim, first the normal and high strength self compacting concrete, NSSCC and HSSCC was designed. Then, the serviceability performance of reinforced connections consisting of NSSCC and HSSCC were investigated. Twelve reinforced concrete connections (L = 3 m, b = 0.15 m, h = 0.3 m) were simulated, by this concretes, the maximum and minimum reinforcement ratios ${\rho}$ and ${\rho}^{\prime}$ (percentage of tensile and compressive steel reinforcement) are in accordance with the provision of the ACI-05 for conventional RC structures. This study was limited to the case of bending without axial load, utilizing simple connections loaded at mid span through a stub (b = 0.15 m, h = 0.3 m, L = 0.3 m) to simulate a beam-column connection. During the test, concrete and steel strains, deflections and crack widths were measured at different locations along each member. Based on the experimental readings and observations, the cracked moment of inertia ($I_{cr}$) of members was determined and the results were compared with some selective theoretical methods. Also, the flexural crack widths of the members were measured and the applicability for conventional vibrated concrete, as for ACI, BS and CSA code, was verified for SCCs members tested. A comparison between two Codes (ACI and CSA) for the theoretical values cracking moment is indicate that, irrespective of the concrete strength, for the specimens reported, the prediction values of two codes are almost equale. The experimental cracked moment of inertia $(I_{cr})_{\exp}$ is lower than its theoretical $(I_{cr})_{th}$ values, and therefore theoretically it is overestimated. Also, a general conclusion is that, by increasing the percentage of ${\rho}$, the value of $I_{cr}$ is increased.

차열도료용 Cool Pigment 및 Paint 개발 (Development of IR Reflective Cool Pigment and Paint)

  • 권면주;도영웅;하진욱
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3800-3805
    • /
    • 2012
  • 본 논문에서는 도심 열섬현상 방지 및 에너지 효율을 높이기 위하여 적외선 반사율이 30%이상인 건물 내 외장재용 흑색 차열안료 및 도료에 대한 연구를 하였다. 안료는 $Fe_2O_3$$Cr_2O_3$의 혼합원료를 $900{\sim}1,200^{\circ}C$에서 소성하여 합성하였으며, 도료는 합성한 안료에 아크릴수지와 기타첨가제를 사용하여 제조하였다. 연구결과, Cr과 Fe을 1:0.9 몰비로 혼합하여 $1,000^{\circ}C$에서 소성한 안료의 발색도가 가장 우수하였고, 차열안료 20%에 분산제 1.5%를 첨가하여 제조한 차열도료로 $125{\mu}m$ 두께의 도막을 형성시켰을 때 적외선 반사가 가장 우수하였다. 차열도료와 일반도료의 표면온도 차이는 $36.5^{\circ}C$로 나타났으며 700~2,500nm 파장대의 적외선 반사율(TSR)은 39.3%로 측정되었다. 또한, 500시간의 내후성 평가에서 색상변화는 거의 나타나지 않았다.

철 함침 낙엽 Biochar에 의한 음이온성 염료의 흡착특성 (Adsorption Characteristics of Anionic Dye by Fe-Decorated Biochar Derived from Fallen Leaves)

  • 박종환;김홍출;김영진;서동철
    • 한국환경농학회지
    • /
    • 제39권4호
    • /
    • pp.289-296
    • /
    • 2020
  • BACKGROUND: There is a need for a revolutionary method to overcome the problem of biochar, which has relatively low adsorption capacity for existing anion pollutants, along with collectively recycling fallen leaves, a kind of forest by-product. Therefore, the objective of this study was to prepare iron-decorated biochar derived from fallen leaves (Fe-FLB), and to evaluate their adsorption properties to Congo red (CR) as anionic dye. METHODS AND RESULTS: The adsorption properties of CR by fallen leaves biochar (FLB) and Fe-FLB were performed under various conditions such as initial CR concentration, reaction time, pH and dosage with isotherm and kinetic models. In this study, Fe-FLB prepared through iron impregnation and pyrolysis of fallen leaves contained 56.9% carbon and 6.3% iron. Congo red adsorption by FLB and Fe-FLB was well described by Langmuir model and pseudo second order model and the maximum adsorption capacities of FLB and Fe-FLB were 1.1 mg/g and 25.6 mg/g, respectively. In particular, it was found that the adsorption of CR was occurred by chemical adsorption process by the outer boundary layer of Fe-FLB. CONCLUSION: Overall, the production of Fe-FLB using fallen leaves and using it as an anion adsorbent is considered to be a way to overcome the problem of biochar with relatively low anion adsorption in addition to the reduction effect of waste.

직업적인 크롬 노출이 혈중 Homocysteine, Folate와 Vitamin B12 농도에 미치는 영향 (Effects of Occupational Chromium Exposure on Plasma Homocysteine, Folate and Vitamin B12 Concentration)

  • 김기웅;김규상;박인정;강성규;오성수;정효석;장성근
    • 한국산업보건학회지
    • /
    • 제16권3호
    • /
    • pp.245-253
    • /
    • 2006
  • We evaluated the relations among exposure and urinary levels of Cr, folate, vitamin $B_{12}$ and Hcy levels in the workers chronically exposure to Cr. Subjects were 104 male employees, 65 workers exposed to Cr in 9 electroplating plants and 39 office workers who had never been occupationally exposed to hazardous substances including Cr. The geometric mean(GM) of Cr in workplace was $0.069{\pm}0.101mg/m^3$ and urinary Cr was $0.483{\pm}0.394mg/g$ creatinine and airborne Cr concentration was significantly correlated to the urinary concentration of Cr(r=0.900, p=0.000). The geometric mean concentration of urinary Cr in control group was $0.301{\pm}0.255mg/g$ creatinine. In comparing the workers exposed to Cr with controls, significantly higher mean plasma levels were found of Hcy($11.3{\pm}4.9$ vs $9.4{\pm}4.7{\mu}mol/{\ell}$, p=0.05), but vitamin $B_{12}$ levels ($181.8{\pm}68.7$ vs $216.0{\pm}64.3nmol/{\ell}$, p=0.01) was significantly decreased. Hcy concentrations correlated positively with airborne Cr concentrations(r=0.287, p=0.004) and urinary Cr concentrations(r=0.244, p=0.015) but folate concentrations correlated negatively with airborne(r=-0.234, p=0.020) and urinary Cr concentrations(r=-0.640, p=0.090), respectively. No correlations were observed between vitamin $B_{12}$, airborne and urinary Cr concentrations. Also, Hcy concentrations correlated positively with vitamin $B_{12}$(r=0.295, p=0.0020 and negatively with folate concentrations(r=-0.196, p=0.046). The various biological(i.e. age and serum indicates) or lifestyle factors(i.e. medication, smoking, alcohol and coffee intake), also taken into account as potential confounders, did not influence the correlations found. Thus, this study found evidence that Cr might be associated with elevated plasma levels of Hcy. Furthermore, elevated plasma levels of Hcy were significantly associated with folate and vitamin $B_{12}$ concentration.

10MV X선 방사선 치료 시 중성자 선량 분포에 관한 연구 (A Study on the Neutron Dose Distribution in Case of 10 MV X-rays Radiotherapy)

  • 박철수;임청환;정홍량;신성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.415-417
    • /
    • 2008
  • 현재 방사선치료는 선형가속기에 의하여 대다수 이루어지고 있으며 사용되는 방사선인 광자도 의학의 발전에 의해 고에너지화 고선량화 되고 있다. 본 연구에서는 방사선치료 조사면에서 중성자 측정이 가능한 CR-39를 이용한 중성자 검출법을 이용하였다. 선형가속기에서 발생되는 X선(광자)치료 시 발생 되는 중성자의 선량을 CR-39를 이용한 중성자 검출법을 이용하여 측정하고, 임상적 응용으로 고에너지 광자를 이용하여 암 치료에 사용할 때 중성자의 발생이 환자치료 선량과 연관되는 어떤 문제를 발생시키는지를 연구한 결과는 다음과 같다. 속중성자의 경우 광자 1Gy 조사 시 평균 0.35mSv, 2Gy 조사 시 평균 0.65mSv, 5Gy 조사 시 평균 1.82mSv, 열중성자의 경우 광자 1Gy 조사 시 평균 0.26mSv, 2Gy 조사 시 평균 0.56mSv, 5Gy 조사 시평균 1.23mSv의 중성자 발생하였다. Wedge Filter를 사용하여 중성자의 발생을 측정한 결과 Wedge Filter를 사용했을 때 중성자의 발생이 증가하였다. 고선량을 요구하는 SRS Cone을 사용했을 때에는 기존의 실험결과 보다 많은 중성자가 검출되었다. 속중성자의 경우 광자 5Gy 조사 시 평균 2.85mSv, 열중성자의 경우 광자 5Gy 조사 시 평균 1.37mSv의 중성자가 발생하였다. 일반 치료 시 광자 5Gy 조사했을 때 보다 속중성자의 경우 약 1.6배, 열중성자의 경우 약 1.12배 정도의 중성자가 더 발생하는 것으로 나타났다.

  • PDF

코팅막 식각으로 인한 플라스틱 렌즈의 특성 변화 (Changes of the Plastic Lens Properties Caused by Etching of the Coating Films)

  • 문병연;왕기주;이윤정;유동식
    • 한국안광학회지
    • /
    • 제15권1호
    • /
    • pp.55-60
    • /
    • 2010
  • 목적: 플라스틱렌즈 표면의 코팅막을 식각한 렌즈와 무코팅렌즈를 비교함으로써, 코팅의 식각이 렌즈에 미치는 변화를 연구하였다. 방법: 굴절력이 0 디옵터인 CR-39, 중굴절률, 고굴절률렌즈를 코팅제거제를 사용하여 $80^{\circ}C$와 상온에서 식각하였고, 굴절력, 투과율 및 렌즈 표면의 변화를 조사하였다. 결과: 코팅의 식각으로 렌즈의 굴절력의 변화는 없었으며, 무코팅렌즈와 식각된 렌즈의 광투과율도 거의 차이가 없었다. 식각속도는 CR-39와 중굴절률렌즈에서 비슷하였으나 고굴절률렌즈에서는 느리고, 불규칙하였다. 렌즈 미세 표면을 관찰한 결과 렌즈 표면에 식각으로 인한 손상이 나타났는데, 중굴절률렌즈의 손상이 가장 적었고, 고굴절률렌즈에서 가장 많았다. 결론: 안경렌즈 표면이 손상되지 않도록 코팅막을 식각하려면, 렌즈 소재에 맞는 적합한 코팅제거제가 사용되어야 하며, 적절한 식각조건에 대한 주의가 필요할 것이다.

베릴륨이 포함되지 않은 도재용착용 비귀금속 합금과 세라믹간의 전단결합강도와 계면특성 (Shear Bond Strength and Interfacial Characterization of Ceramic to Beryllium Free Nonprecious Alloys for Porcelain Fused to Metal Crown)

  • 정인성;김치영
    • 한국콘텐츠학회논문지
    • /
    • 제10권11호
    • /
    • pp.228-234
    • /
    • 2010
  • 치과도재용 합금으로 사용되는 합금 중 베릴륨이 함유된 비귀금속 Ni-Cr합금과 베릴륨이 함유되지 않은 비귀금속 Ni-Cr합금 그리고 베릴륨이 함유되지 않은 비귀금속 Co-Cr 합금과 세라믹간의 결합강도와 파절양상 그리고 계면특성을 분석하고자 하였다. 결합강도는 만능시험기를 이용하여 전단력시험을 통하여 전단결합력을 측정하였으며, 전단시험에 의한 파단면을 이용하여 파절양상을 관찰하였다. 그리고 합금-도재간의 계면을 관찰하였다. 전단결합강도 측정 결과, 베릴륨이 포함된 T-3가 41.13(${\pm}5.11$)MPa로 가장 높게 나타났으며, 베릴륨이 포함된 VeraBond(40.72(${\pm}5.98$)MPa), Co-Cr 합금인 Wirobond(38.40(${\pm}9.66$)MPa), 베릴륨이 포함되지 않은 Verabond 2V(32.77(${\pm}4.31$)MPa), Bellabond N(28.63(${\pm}6.39$)MPa), Bellabond plus(24.97(${\pm}6.13$)MPa), Argeloy N.P. Star(22.69(${\pm}3.41$)MPa) 순으로 나타났다. 비귀금속 합금들과 세라믹간의 파절양상은 모든 시편에서 금속표면에 세라믹이 일부 부착된 복합파절(mixed failure) 양상을 보였다.

$Ar^+$ RF 플라즈마 처리조건이 임베디드 PCB내 전극 Cu박막과 ALD $Al_2O_3$ 박막 사이의 계면파괴에너지에 미치는 영향 (Effect of $Ar^+$ RF Plasma Treatment Conditions on Interfacial Adhesion Energy Between Cu and ALD $Al_2O_3$ Thin Films for Embedded PCB Applications)

  • 박성철;이장희;이정원;이인형;이승은;송병익;정율교;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제14권1호
    • /
    • pp.61-68
    • /
    • 2007
  • 임베디드 PCB 기판내 유전체 재료인 Atomic Layer Deposition(ALD) $Al_2O_3$ 박막과 전극재료인 스퍼터 증착된 Cu박막 사이의 계면접착력을 $90^{\circ}$ 필 테스트방법으로 측정하여 순수 빔 굽힘을 가정한 에너지 평형 해석을 통하여 계면파괴에너지를 구하였다. $Cu/Al_2O_3$의 계면파괴에너지(${\Gamma}$)는 매우 약하여 측정할 수 없었으나, 접착력 향상층 Cr 박막을 삽입하여 $Cr/Al_2O_3$의 계면파괴에너지는 $10.8{\pm}5.5g/mm$를 얻었다. $Al_2O_3$ 표면에 $0.123W/cm^2$ 의 power density로 2분간 $Ar^+$ RF 플라즈마 전처리를 하고 Cr박막을 삽입한 $Cr/Al_2O_3$ 계면파괴에너지는 $39.8{\pm}3.2g/mm$으로 매우 크게 증가하였는데, 이는 $Ar^+$ RF 플라즈마 전처리에 따른 mechanical interlocking효과와 Cr-O 화학결합 효과가 동시에 기여한 것으로 생각된다.

  • PDF

오염된 해양퇴적물에서 중금속 용출 차단을 위한 제올라이트, 몬모릴로나이트, 제강슬래그의 적용성 평가 (Assesment of Zeolite, Montmorillonite, and Steel Slag for Interrupting Heavy Metals Release from Contaminated Marine Sediments for Capping Thickness of Reactive materials)

  • 강구;김영기;박성직
    • 한국항해항만학회지
    • /
    • 제39권4호
    • /
    • pp.335-344
    • /
    • 2015
  • 본 연구에서는 반응성 피복소재인 제올라이트, 몬모릴로나이트, 제강슬래그의 피복두께에 따른 오염된 해양퇴적물 내 중금속 용출 차단 효율을 평가하였다. 실험결과, As의 용출차단에는 제올라이트, 몬모릴로나이트, 제강슬래그 모두 효과적이지 못하였다. 제올라이트는 Cr 용출 차단에 부정적인 영향을 미치는 것으로 나타났지만, 몬모릴로나이트 5 cm 피복은 Cr 용출 차단에 매우 효과적이었다. As 및 Cr과는 대조적으로 Cd, Ni, 그리고 Pb은 미피복 퇴적물에서 조차 용출되지 않았다. Cu와 Zn은 피복 조건에 따른 영향이 가장 뚜렷한 중금속이었다. Cu의 용출은 몬모릴로나이트 피복 두께 1 cm 이상 그리고 제올라이트 피복 두께 3 cm 이상에서 효과적으로 차단되었다. 해양퇴적물에서 Zn의 용출은 모든 피복 물질에서 효과적이었다. 본 연구를 통해서 제올라이트, 몬모릴로나이트, 제강슬래그를 오염된 해양퇴적물에서 Cr, Cu, Zn의 용출 차단을 위한 효과적인 피복소재로 활용할 수 있을 것으로 판단된다.

서울 지역 도로가 퇴적물의 중금속 함량

  • 최병영;윤성택;이평구
    • 대한자원환경지질학회:학술대회논문집
    • /
    • 대한자원환경지질학회 1999년도 춘계 공동학술발표회
    • /
    • pp.39-42
    • /
    • 1999
  • 1) 서울 지역 도로가 퇴적물에서는 특히 Cu와 Zn의 오염이 도심 지역을 중심으로 심각하게 진행되고 있으며. Pb는 무연 휘발유의 사용량 증가와 더불어 감소 추세이나 여전히 높은 함량을 나타내고 있다. 2) Pb와 Cr의 함량은 공간적 지배가 강하여 Pb는 주로 교통 혼잡 지역, Cr은 공구상 밀집 지역에서 높게 나타난다. 반면, Cu, Cd, Zn 함량은 시간적 및 공간적 변화를 모두 보여주어 금속 산업 밀집도 및 강우량 변화에 따라 변화된다. 3) 특히 오염이 심화되고 있는 지역의 도로가 퇴적물이 하수계로 직접 유입되지 못하도록 차단하는 적절한 시설이 필요하며, 아울러 오염된 퇴적물을 집적하여 처분할 때는 주변 토양의 오염에 유의해야 할 것이다.

  • PDF