• 제목/요약/키워드: COV(Coefficient of Variation)

검색결과 94건 처리시간 0.021초

현장시험을 이용한 인천 송도지반의 변동성 분석 (Geotechnical Variability Characterization of Songdo area in Incheon by Field Tests)

  • 김동휘;배경두;이주형;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1435-1440
    • /
    • 2009
  • Geotechnical variability is a complex feature that results from many independent sources of uncertainties, and is mainly affected by inherent variability and measurement errors. This study evaluates the coefficient of variation (COV) of soil properties at Song-do region in Korea for evaluating inherent soil variability. Since soil variability is sensitive to soil layers and soil types, the COVs by soil layers (reclaimed layer and marine layer) and the COVs by soil types (clay and silt) were separately evaluated. It is observed that geotechnical variability of marine layer and clay is relatively smaller than that of reclamation layer and silt.

  • PDF

고급 모델 반복 재구성법 (ADMIRE)을 사용한 CT 영상에서의 노이즈 레벨 및 블라인드 화질 평가 (Evaluation of Noise Level and Blind Quality in CT Images using Advanced Modeled Iterative Reconstruction (ADMIRE))

  • 심지나;강성현;이영진
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.203-209
    • /
    • 2022
  • 전산화단층촬영장치 (Computed Tomography, CT)의 화질을 유지하면서 방사선량을 낮추기 위한 대표적인 방법 중에 하나는 모델기반 반복 재구성법 (Model-Based Iterative Reconstruction, MBIR)을 사용하는 것이다. 본 연구에서는 MBIR의 대표적인 모델로 잘 알려진 고급 모델 반복 재구성법 (Advanced Modeled Iterative Reconstruction, ADMIRE)의 강도를 조절하여 영상의 화질을 평가하고자 하였다. 연구는 팬텀을 사용하여 수행되었고, ADMIRE의 강도를 1에서부터 5까지 1 단위로 조절하면서 CT 영상을 획득하였다. 정량적 평가는 변동 계수 (coefficient of variation, COV)와 대조도 대 잡음비 (contrast to noise ratio, CNR)를 활용한 노이즈 레벨과 natural image quality evaluator (NIQE)와 blind/referenceless image spatial quality evaluator (BRISQUE)의 블라인드 품질 평가를 수행하였다. 결과적으로 노이즈 레벨 및 블라인드 품질 평가 결과에서 모두 ADMIRE의 강도가 높아질수록 우수한 결과가 도출되었다. 특히, COV와 CNR은 ADMIRE 1에 비하여 5에서 각각 1.89 및 1.75배 향상됨을 확인하였고, NIQE와 BRISQUE는 재구성 강도 1에 비하여 5에서 각각 1.35 및 1.22배 향상됨이 증명되었다. 결론적으로 ADMIRE의 재구성 강도는 CT 영상의 노이즈 레벨 및 전체적인 화질 평가에 큰 영향을 끼친다는 것을 증명하였다.

간경변 초음파 영상에서의 노이즈 제거를 위한 Median Modified Wiener Filter 알고리즘의 유용성 (Usefulness of Median Modified Wiener Filter Algorithm for Noise Reduction in Liver Cirrhosis Ultrasound Image)

  • 김승연;강수민;이영진
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.911-917
    • /
    • 2023
  • 임상 초음파 검사를 사용한 간 표면의 결절성 변화를 관찰하는 방법은 간경변 진단에 유용하게 사용되고 있다. 하지만 초음파 영상에서 필연적으로 발생되는 speckle 노이즈는 간표면과 echo 패턴 변화의 식별을 어렵게 하므로 간경변 진단에 부정적인 영향을 끼친다. 본 연구의 목적은 간경변 초음파 영상의 노이즈를 효율적으로 줄일 수 있는 변형된 중간값 위너 필터(median modified Wiener filter, MMWF)를 모델링하여 적용 가능성을 확인하는 것이다. ACR 팬텀과 실제 간경변 환자를 통해 초음파 영상을 획득하였고, 각각의 영상마다 제안하는 MMWF 알고리즘과 conventional filter 들을 적용하였다. 획득된 초음파 영상들의 정량적 화질 평가인자로는 변동 계수(coefficient of variation, COV)와 가장자리 상승 거리(edge rise distance, ERD)를 사용하였다. ACR 팬텀과 실제 간경변 환자의 초음파 영상 모두에서 MMWF 알고리즘이 conventional filter 보다 COV와 ERD 값이 모두 향상되었음을 확인하였다. 결론적으로 제안하는 MMWF 알고리즘은 노이즈 레벨을 줄일 수 있음과 동시에 공간 분해능을 향상시킬 수 있어 간경변 환자의 진단률 향상에 기여할 수 있을 것으로 기대한다.

유방엑스선검사에서의 변형된 ACR 팬텀 제작을 통한 모조병소의 위치와 두께 변화에 따른 영상의 품질 평가 (Evaluation of Image Quality according to Insert Position and Thickness Change by Fabricating Modified ACR Phantom in Mammography)

  • 엄현자;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.103-109
    • /
    • 2022
  • To maintain improved image quality in mammography, the quality control process is performed using the ACR (American college of radiology) phantom. In addition, many studied were performed by fabricating the customized breast phantom to provide more information in mammography. Thus, the purpose of this study was to evaluate the image quality by designing the modified ACR phantoms. The five modified acrlylic ACR phantoms were designed by considering insert position and phantom thickness. The phantoms were consisted of 4.5, 3.0, and 1.5 cm in terms of phantom thickness, and 3.0, 2.0, and 0.5 cm in terms of insert position, respectively. The acquired images were evaluated by PSNR (peak signal to noise ratio), RMSE (root mean square error), CC (correlation coefficient), CNR (contrast to noise ratio), and COV (coefficient of variation). Based on the similarity analysis, the result is suitable between conventional and new designed phantoms. In addition, the CNR and COV results in terms of insert position showed that image quality for 0.5 cm was 2.3 and 27.4% improved compared with 2 and 3 cm, respectively. According to phantom thickness results, the CNR result for 1.5 cm and COV result for 4.5 cm were 50.1 and 62.7% improved compared with that those conditions. In conclusion, we confirmed that the image quality depends on the breast size and thickness through modified ACR phantom study.

Quality Evaluation of Ultrasonographic Equipment Using an ATS-539 Multipurpose Phantom in Veterinary Medicine

  • Cho, Young-kwon;Lee, Youngjin;Lee, Kichang
    • 한국임상수의학회지
    • /
    • 제39권3호
    • /
    • pp.114-120
    • /
    • 2022
  • The purpose of this study is to examine the status of quality control using multipurpose phantom of ultrasound equipment used in hospital of veterinary college in South Korea by using ATS-539 multipurpose phantom so as to examine quantitative and objective new image evaluation method. Specialists discussed and analyzed multipurpose phantom images acquired by using convex transducer of 10 ultrasound imaging devices, currently used in 9 veterinary colleges, at 4.0-6.0 MHz. Total 8 items that can be measured with ATS-539 multipurpose phantom including dead zone, vertical and horizontal measurement, axial/lateral resolution, sensitivity, focal zone, functional resolution and gray scale/dynamic range were evaluated. For qualitative evaluation, valid decisions were made based on dead zone, axial/lateral resolution, and gray scale/dynamic range which are resolution index, and coefficient of variation (COV) and blind referenceless image spatial quality evaluator (BRISQUE) were found to increase objectivity. As a result of experiment, all the targeted ultrasonic devices were found appropriate from qualitative evaluation items of dead zone, axial/lateral resolution, and gray scale/dynamic range. In other evaluation items, they were found to be appropriate from focal zone and vertical measurement of quantitative evaluation while inappropriate from horizontal measurement, sensitivity, and functional resolution. COV value was 0.12 ± 0.04, and BRISQUE value was 47.77 ± 2.77, both analysis results show that the noise level of all ultrasonic devices was located within tolerance range. Upon image examination using ATS-539 multipurpose phantom, they were 100% appropriate with inspection standards of dead zone, axial/lateral resolution, and gray scale/dynamic range, and besides, focal zone and functional resolution can be used as evaluation items. In the field of veterinary medicine, 8 standard items using ATS-539 multipurpose phantom and image evaluation items using COV and BRISQUE can be used as standards for quality control of ultrasonography machine.

도심지에서 46년 사용된 교량 상부구조물에서 채취한 코어를 통한 탄산화 실태조사 (Carbonation Assessment for Superstructure of Bridge Used in Urban Area for 46-Years by Core Specimens Extracted from the Structure)

  • 권승희;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제7권2호
    • /
    • pp.151-157
    • /
    • 2019
  • 대도시에 시공된 콘크리트 교량의 경우 상부의 슬래브 및 PSC 거더가 같이 존재하고 있으며 설계 강도 및 국소적인 환경의 변동성으로 탄산화 거동이 다르게 평가된다. 본 연구에서는 46년간 사용된 PSC 거더교에 대하여 54개의 콘크리트 코어를 채취하였으며, 압축강도 및 탄산화 깊이 평가를 수행하였다. 설계 강도 24MPa인 슬래브와 35MPa인 I형 거더에 대하여 코어압축강도는 19.6MPa과 25.4MPa로 평가되어 각각 84% 및 73% 수준으로 조사되었다. 탄산화의 경우 상부에 대해서는 30.6mm의 탄산화 깊이와 32.9%의 높은 변동성을 나타내었다. I형 거더의 경우 상부에 비하여 16.7~17.0mm의 탄산화 깊이와 22.8~33.6%의 변동성을 나타내었다. I형 거더의 경우 상부 슬래브에 비하여 낮은 탄산화 깊이와 변동성을 가지고 있었으나, 하부구조에 비해서 높은 변동성을 가지고 있음을 알 수 있다.

축 압축력과 수압하의 손상된 원통의 잔류 강도 추정을 위한 설계식 (Design Equation for Predicting the Residual Strength of Damaged Tubulars Under Combined Axial Compression and Hydrostatic Pressure)

  • 조상래
    • 대한조선학회지
    • /
    • 제26권4호
    • /
    • pp.44-56
    • /
    • 1989
  • 최근 배와의 충돌이나 중량물의 낙하 또는 건조, 설치 및 운영과정 중 예기치 않은 충격 하중으로 인한 해양 구조물의 손상 과정이나, 손상 후의 잔류 강도에 관한 연구가 많은 관심을 끌고 있다. 잔류 강도의 경우, 축 압축력 하의 손상된 원통의 거동에 관한 연구는 많이 이루어진 편이나 수면하 부재가 손상을 입는 경우, 즉 수압을 포함한 복합하중 하의 손상된 원통의 거동에 관한 연구결과는 거의 발표되지 않은 상태이다. 본 논문에서는 수압과 압축력에 대한 손상 원통의 잔류 강도를 추정할 수 있는 수치 해석 방법을 제안하고, 관련된 실험 결과들과 비교하여 검증하였다. 또한 이 방법을 사용한 수치 해석 결과를 바탕으로 간편한 설계식을 유도하였다. 이 설계식에 의한 추정 값과 실험 결과를 비교한 바, 그 비의 평균이 1.037이고 COV(coefficient of variation)는 10.1%가 되었다.

  • PDF

터널 붕괴 위험도 분석을 위한 영향인자 가중치 산정에 관한 연구 (A study on the weighting of influence factors for tunnel collapse risk analysis)

  • 김정흠
    • 한국터널지하공간학회 논문집
    • /
    • 제26권4호
    • /
    • pp.315-326
    • /
    • 2024
  • 본 연구에서는 터널 붕괴 위험도를 종합적이고 다각적인 관점에서 평가하기 위해 델파이 기법과 AHP (analytic hierarchy process) 기법을 사용하였다. 영향인자 정립은 문헌조사, 선행 연구 및 전문가 집단의 브레인스토밍 과정을 통해 총 5개의 상위분류체계를 구축하였다. 21명의 전문가 패널을 구성하여 총 3차의 델파이 조사 과정을 통해 전문가 판단과정에서 오류 및 편향을 방지하여 신뢰성을 향상시켰다. 최종적으로 전문가 답변에 대한 CVR (content validity ration) 및 COV (coefficient of variation) 분석을 수행하여 총 14개의 영향인자를 도출하였다. 이후 AHP 기법을 적용하여 각 영향인자의 상대적 중요도를 평가하고 최종 복합 가중치를 산정하였다. 지보 및 보강 시행시기가 가장 높은 우선순위를 가지며, 지하수 유입량, 절리면 상태, 지보패턴수준, 보조공법이 그 뒤를 이었다. 이러한 연구 결과를 통해 터널붕괴 위험에 영향을 미치는 주요 요인들을 파악하고, 이를 토대로 터널 안전성을 향상시키는 전략을 수립하는데 도움이 될 것으로 기대된다.

A Review of the Topographical Causes of Gloss Variation and the Effect on Perceived Print Quality

  • MacGregor, Michael A.
    • 펄프종이기술
    • /
    • 제32권5호
    • /
    • pp.26-43
    • /
    • 2000
  • It is well accepted that gloss variation deteriorates the print quality and there are various objective ways to measure this. Several studies now have shown that the coefficient of variation in the octave band passed printed gloss image has an excellent correlation with ratings by an expert panel using a magnitude estimation scaling method. The correlation improves when the gloss level is also taken into account beyond that of the COV. There is also evidence that the correlation would improve even more if the gloss spatial distribution could be better accounted for. We show that much (at least 80% and perhaps up to 90%) of the gloss distribution can be accounted for by the paper topography over a wide range of dimensions (scale). Recent work has supported the role that microroughness and multiple surface scattering play in the gloss distribution. This offers the promise of showing that even a greater amount of gloss variationcan be explained by topography.

  • PDF

국내설계기준과 피복두께를 고려한 RC 구조물의 탄산화 내구수명의 변동성 (Service Life Variation for RC Structure under Carbonation Considering Korean Design Standard and Design Cover Depth)

  • 김윤식;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.15-23
    • /
    • 2021
  • 본 연구에서는 탄산화에 노출된 하부 콘크리트 구조물을 대상으로, 실태조사 결과와 국내 시방서를 고려하여 결정론 및 확률론적 방법에 따른 내구수명을 도출하였다. 또한 변동계수의 변화에 따른 내구수명의 변화와 결정론적 해석 결과와 비슷한 결과를 제시하는 신뢰도 지수를 고찰하였다. 문헌조사 결과 도심지 하부 구조물의 피복두께의 평균은 70.0 ~ 90.0 mm였으며, 변동계수는 0.2 수준으로 조사되었다. 목표 내구수명 파괴확률을 10.0 %로 설정한 확률론적 내구수명 해석 방법의 경우 피복두께가 70 mm일 때 피복두께 변동계수 0.05, 0.1, 0.2에 해당하는 내구수명은 137년, 123년, 91년이 도출되었으며 피복두께가 80 mm인 경우 내구수명은 각각 179년, 161년, 120년으로 도출되었다. 결정론적 내구수명 평가와 동일한 수준의 신뢰도 지수를 평가하였는데 피복두께가 70 mm일 때 1.66 ~ 3.43 수준으로, 피복두께가 80 mm일 때 1.61 ~ 3.24 수준으로 평가되었다. 결정론적인 방법에서는 다양한 품질 및 국부적인 환경계수가 크게 고려되어 있는데, 이에 따라 내구수명이 크게 변화하므로 환경 및 설계인자의 변동성을 고려한 탄산화 설계변수의 정의가 필요하다.