• Title/Summary/Keyword: CO2 Rate

Search Result 5,777, Processing Time 0.031 seconds

Effects of $CO_2$ addition to Oxygen-Enriched Combustion (산소부화연소에서 $CO_2$ 첨가에 대한 영향)

  • Kim, Ho-Keun;Kim, Han-Seok;Ahn, Kook-Young;Kim, Yong-Mo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1389-1394
    • /
    • 2003
  • $CO_2$ is a well-known green house gas, which is the major source of global warming. Many researchers have studied to reduce $CO_2$ emission in combustion processes. Among the method for reducing $CO_2$ emission, oxygen-enriched combustion has been proposed. But the adiabatic flame temperature is too high. So existing facilities must be changed, or the adiabatic flame temperature in the combustion zone should be reduced. The combustion characteristics, composition in the flame zone, temperature profile and emission gases were studied experimentally for the various oxygen-enriched mtios(OER) by addition of $CO_2$ under coustant $O_2$ flowrate. Results showed that the reaction zone was quenched, broadened, as addition of $CO_2$ was increased. Temperature has a large effect on the NOx emission. The emission of NOx in flue gas decreased due to the decreased temperature of reaction zone. It was also shown that the reaction was delayed by the cooling effect. As the addition of $CO_2$ was increased, the composition of CO in the flame zone increased due to the increase of reaction rate by increasing mixing effect of oxidant/fuel at OER=0, but the composition of CO decreased by quenching effect at OER=50 and 100%.

  • PDF

Study of Smoking Component Distribution and the Relation between Chemical Components and Physical Characteristics of Cigarettes (제품담배 연기성분 분포 특성 조사 및 물리적 특성과의 관련성 구명)

  • 황건중;이영택
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.2
    • /
    • pp.179-184
    • /
    • 2001
  • This study was conducted to determine the smoke component distribution and the relationship between chemical components and physical characteristics of cigarettes. 16 different cigarette brands which were sold in the market were selected for this study. Five kinds of smoke components which have been tar, nicotine, water, carbon monoxide(CO) puff No., and six kinds of physical characteristics which were filter type, leaf weight, filter weight, UPD, EPD, dilution rate were analyzed. The average values in tar, nicotine, water, CO concentration were 6.5 mg/cig. 0.66 mg/cig, 1.12 mg/cig. and 6.32 mg/cig., respectively. The average ratios of nicotine/tar and CO/tar were 0.10, and 1.02 respectively. The distribution of smoke components collected in the cambridge filter and cigarette filter was different. The averages of tar and nicotine removal efficiency by a cigarette filter were 53%, and 48%, respectively. All smoking components were positively correlated with other smoking components. filter types, EPD, and dilution rate were showed high correlation to the changes of smoke components. Especially, dilution rate of cigarette strongly affected on the changes of all smoke components.

  • PDF

Kinetics and Mechanism for Redox Reaction of cis-$[Co(en)_2(N_3)_2]^+$ with Fe(II) in Acidic Solution (산 촉매하에서 cis-$[Co(en)_2(N_3)_2]^+$ 와 Fe(II) 와의 산화-환원반응에 대한 반응속도와 메카니즘)

  • Byung-Kak Park;Kwang-Jin Kim;Joo-Sang Lim
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.309-314
    • /
    • 1989
  • A kinetic study was carried out for the redox reaction of cis-$[Co(en)_2(N_3)_2]^+$ with Fe(II) in acidic solution by spectrophotometric methods. This redox reaction system have been found to show a third order for overall reaction as the respective first order with respect to reactant cis-$[Co(en)_2(N_3)_2]^+$, Fe(II), and $H^+$ catalyst. The activation parameters, ${\Delta}H^{\neq}$ and ${\Delta}S^{\neq}$, were obtained as 14.2Kcal/mol and -16.7 e.u., respectively. On the basis of the kinetic data, we suggest that the redox reaction system proceeds via inner sphere mechanism. The rate equation derived from the proposed mechanism is in agreement with the observed rate equation.

  • PDF

The Effects of the Area of Openings on the Performance of a $CO_2$ Extinguishing System -The CFD Simulations of the Oil Surface Fire in a Machine Room- (개구부 면적이 $CO_2$ 소화설비의 소화성능에 미치는 영향 -기계실 석유 표면화재의 CFD simulations-)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Park, Jong-Tack
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Carbon dioxide($CO_2$) agent, which has more safely extinguished fire than any other gaseous fire extinguishing agents, has been widely used in various protected enclosures and types of fires. According to the concept of performance-based design(PBD). $CO_2$ extinguishing system to be designed is needed to be evaluated for the performance of fire suppression with possible fire scenarios in an enclosure. In this paper, CFD simulations were carried out to study the effects of opening area on the performance of $CO_2$ extinguishing system and the flow characteristics in the machine room of $100m^3$ in which kerosene spill fire happened. This study showed that time of fire suppression increased linearly in proportion to the size of opening area, and fires for each model were completely suppressed prior to the end of discharge of $CO_2$ agent. It was shown that mass flow rate through opening was influenced by the combined effects of heat release rate of fire and discharge of $CO_2$ agent. After $CO_2$ agent was completely discharged, oxygen concentrations in enclosures for each model were lower than the limit concentration of combustion.

CO2 Emission and Productivity of Fossil-fueled Power Plants: A Luenberger Indicator Approach (CO2 배출량을 감안한 화력발전소의 생산성 변화 분석: Luenberger지수 접근법)

  • Kwon, Oh-Sang
    • Environmental and Resource Economics Review
    • /
    • v.19 no.4
    • /
    • pp.733-752
    • /
    • 2010
  • This study applies the Luenberger indicator approach to estimate productivity of the Korean fossil-fueled power plants. A panel data set of 25 power plants was used. The method incorporates $CO_2$ emission as an undesirable output and shows that ignoring $CO_2$ emission overestimates the productivity change. There are two sources of overestimation. First, the usual method estimates productivity change ignoring the increase in $CO_2$ emission that occurred during the study period. Second, the productivity change estimated by the usual method that does not incorporate $CO_2$ emission is very sensitively affected by the change in operation rate. The paper decomposes the productivity change into the efficiency change and the technical change. The results show that the two sources contribute to the productivity change almost equally. It is also shown that the size and the pattern of productivity change are dependent on the plants' fuel types. Non-LNG power plants which saved their energy consumption and thereby reduced their $CO_2$ emission have achieved relatively high rate of productivity improvement.

  • PDF

Dose Characteristics by the Co-60 Source Oscillations in High Dose Rate After Loading Irradiations (고선량율 원격강내조사의 코발트-60 이동선원에 의한 선량특성)

  • 최태진;김옥배;노홍균
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.51-60
    • /
    • 1990
  • Dose distributions around Co- 60 moving source in high dose rate remote afterloading unit, Buchler 3K unit, were experimented with X-omat V films and calculations. In our experiments, film dosimetries have achieved to evaluated the axial dose distributions for source oscillations were 0, 3.5, 5.0 and 6.0 cm in periodically, In results, the dose distributions in axial of source movement showed apparently higher than in transverse direction caused by source locations, dwelling time and air gap in the applicator. In the calculations, the dose rate was derived by using the inverse square law, filteration corrections and Meisberger constant for scatter corrections as source movings. In our experiments and calculations, the average dose uncertainties were showed -2.1$\pm$1.9% in fixed sourdce, -2.9$\pm$1.8%, -7.4$\pm$6.1% and -6.7$\pm$4.6% at 3.5 cm, 5.0 cm and 6.0 cm source oscillations, but the calculations have showed very close to experimental dose rate within 4 cm distance from source.

  • PDF

Preparation of ATO Thin Films by DC Magnetron Sputtering (I) Deposition Characteristics (DC Magnetron Sputtering에 의한 ATO 박막의 제조 (I)증착특성)

  • Yoon, C.;Lee, H.Y.;Chung, Y.J.
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.4
    • /
    • pp.441-447
    • /
    • 1996
  • Sb doped SnO2(ATO:Antinomy doped Tin Oxide) thin films were prepared by a DC magnetron spttuering method using oxide target and the deposition characteristics were investigated. The experimental conditions are as follows :Ar flow rate : 100 sccm oxygen flow rates ; 0-100 sccm deposition temperature ; 250 -40$0^{\circ}C$ DC sputter powder ; 150~550 W and sputtering pressure ; ; 2~7 mTorr. Deposition rate greatly depends not on the deposition temperature but on the reaction pressure oxygen flow rate and sputter power,. when the sputter powder is low ATO thin films with (110) preferred orientation are deposited. And when the sputter power is high (110) prefered orientation appeares with decreasing of oxygen flow rate and increasing of suputte-ring pressure.

  • PDF

Compilation of Respiration Model Parameters for Designing Modified Atmosphere Package of Fresh Produce

  • An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • Enzyme kinetics-based respiration model can be effectively used for estimating respiration rate in $O_2$ consumption and $CO_2$ production of fresh produce as a function of $O_2$ and $CO_2$ concentrations. Arrhenius equation can be applied to describe the temperature dependence of the respiration rate. Parameters of enzyme kinetics-based respiration model and activation energy of Arrhenius equation were compiled from analysis of literature data and closed system experiment. They enable to estimate the respiration rate for any modified atmosphere conditions at temperature of interest and thus can be used for design of modified atmosphere packaging of fresh produce.

  • PDF

Development of an Catalyst for Hydrolysis of Aqueous Sodium Borohydride Solution ($NaBH_4$ 수용액 분해 수소 발생용 최적 촉매 개발)

  • Yang Tae-Hyun;Krishnan Palanichamy;Lee Won-Yong;Kim Chang-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.296-298
    • /
    • 2005
  • Hydrogen generation by the hydrolysis of aqueous sodium borohydride $(NaBH_4)$ solutions was studied using IRA-400 anion resin dispersed Pt. Ru catalysts and Lithium Cobalt oxide $(LiCoO_2)$ supported Pt, Ru and PtRu catalysts. The performance of the $LiCoO_2$ supported catalysts is better than the ion exchange resin dispersed catalysts. There is a marked concentration dependence on the performance of the $LiCoO_2$ supported catalysts and the hydrogen generation rate goes down if the borohydride concentration is increased beyond $10\%$. The efficiency of PtRu- $LiCoO_2$ is almost double that of either Ru-$LiCoO_2$ or Pt-$LiCoO_2$ for $NaBH_4$ concentrations up to $10\%$.

  • PDF

Conversion Characteristics of $CO_2$ by Glow Discharge Plasm (글로우 방전 플라즈마에 의한 탄산가스 전환특성)

  • 곽동주;하양진;신용섭;최연석
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.3
    • /
    • pp.248-254
    • /
    • 1998
  • In the present study the glow discharge characteristics of $CO_2$ in a parallel plate electrode system were investigated, and the decomposition properties of $CO_2$ concerned with the discharge characteristics were discussed. The results show that $CO_2$ concentration decreases with increase in discharge power and decrease in gas pressure. The maximum conversion of $CO_2$ by glow discharge was 52% under the conditions of gas pressure, 10m Torr and 290W of discharge power.

  • PDF