• Title/Summary/Keyword: CO Emission

Search Result 3,119, Processing Time 0.028 seconds

A Study on Comparing the CO2 Emission Estimating Result for Construction Equipment (건설장비 CO2배출량산출결과 비교연구)

  • Kim, Byung-Soo;Jang, Won-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1675-1682
    • /
    • 2013
  • To resolve the Global Warming problem, it have to reduce $CO_2$ emission. Korea need to do actively more the effort to reduce the emission because $CO_2$ emission per person is top level in the world. It is performing variously. However, we should recognize the $CO_2$ emission attribute to decrease $CO_2$. Analyzing $CO_2$ emission of the construction equipment is important in this aspect. Present, the most popular $CO_2$ emission measuring method is the way using fuel consumption and emission factor. But this method have the problem of reliability because can't reflect the factor being out of proportion at fuel consumption. This study analyzed the reason of difference and compared to the emission factor method after calculate $CO_2$ emission in direct measurement method.

Emission Characteristics of LP Gas Burner for the Variation of Combustion Conditions (연소조건 변화에 따른 LP가스버너의 배기특성)

  • 이병곤;오택흠
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.1-6
    • /
    • 2001
  • An experimental study was carried out to investigate the emission characteristics of LP gas burner for the Practical combustion conditions including fm voltage, inlet area, gas Pressure, emission resistance, duct length and height. The result shows that CO is almost remains constant for the emission fan voltage, but significantly increases with the reduction rate of air inlet, up to 3000ppm at 50% of reduction rate. Also, the variation of gas pressure has no effect to CO of gas boiler due to its governor which controls gas pressure secondly, but it gives an rapid increase of CO for the gas range. The emission resistance test shows that CO is suddenly increased with the reduction rate of emission duct above 70% and main burner is stopped at 90%. The reverse wind test shows that CO is suddenly increased with the air velocity above 7m/s and main burner is stopped at 9m/s. The more horizontal length of emission duct is long and the vertical height is low, CO is infinitesimally increased.

  • PDF

The Measurement Method of CO2 Emission for Construction Equipment using ZigBee Sensor (ZigBee 센서를 활용한 건설장비의 CO2 배출량 측정방법)

  • Chun, Jin-Ku;Kim, Byung-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2D
    • /
    • pp.167-174
    • /
    • 2012
  • Recently, the effort to reduce $CO_2$ emission concerning certified emission reductions (CERs) is progressing lively with the institute in the center through lifecycle. However, the technique for reduce $CO_2$ emission is the first stage yet and the technique is insufficient to calculate with accuracy it. Therefore, this study tries to develop the method to measure by actual time $CO_2$ emission of construction equipment using Zigbee sensor. To review the method that calculate $CO_2$ emission, have classified the impact factors that affect at $CO_2$ emission by IPCC guideline. It also has review the application of Zigbee sensor that use wireless data communication. The reviewed result get that the measuring objects are the $CO_2$ emssion, RPM and fuel consumption of equipment, there are needs to search the year of equipment, waiting time, kind of vehicle and fuel that affect to $CO_2$ emission.

Calculation of CO2 Emission for Fossil-Fired Thermal Power Plant considering Coal-Oil Mix Rate (혼소율을 고려한 화력 발전소의 CO2 대기배출량 계산)

  • Lee, Sang-Joong;Kim, Soon-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.67-72
    • /
    • 2010
  • G8 summit meeting held in July 2008 decided to set up a long-term goal, by 2050, reducing the world greenhouse emissions by half of those emitted in 1990. In November 2009, the Government announced to reduce the national $CO_2$ emission by 30[%] of BAU by 2020. Electric power industries in Korea produce most of their electricity by burning fossil fuels, and emit approximately 28[%] of national $CO_2$ emissions. Monitoring the $CO_2$ emissions. Monitoring the $CO_2$ emission of electric power plants is very important. This paper presents a method to calculate the hourly $CO_2$ emission for a thermal power plant burning mixture of coal and oil using the performance test data and coal-oil mix rate. An example of $CO_2$ emission calculation is also demonstrated.

The CO2 Emission in the Process of Cement Manufacture Depending on CaO Content (시멘트 생산과정에 따른 CaO 함량과 CO2의 발생량)

  • Kim, Sang-Hyo;Hwang, Jun-Pil
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.4
    • /
    • pp.365-370
    • /
    • 2013
  • In this study, contents of limestone in cement manufactured by six domestic plants for Portland cement were investigated in terms of the strength and its relation to the $CO_2$ emission due to limestone material and its physical properties in cement manufacturing process. the relationship among CaO content, compressive strength, and $CO_2$ emission was surveyed for the limestone quantity in decomposition reaction and the loss of limestone quantity contained in each cement. As a result of $CO_2$ emission calculation for unit cement, it was found that the $CO_2$ emission due to decomposition of limestone was occupied 67% of total emission quantity. Furthermore, there was a difference in $CO_2$ emission quantity depending on the cement manufacturing process management. Also, it was shown that fossil fuel usage and material loss had a major influence as main factors of $CO_2$ emission. An increase in the CaO content in cement resulted in an increase in the compressive strength. On the contrary, CaO content and compressive strength were reduced with the growth of loss quantity of limestone. It was verified that the material and process management were more effective than CaO yield in cement manufacturing for $CO_2$ emission with the growth of $CO_2$ emission quantity. Pozzolanic materials such as PFA and GGBS in concrete mix affected the price, $CO_2$ emission and development of strength of concrete.

A Study on The Evaluation Criteria of Carbon Emission and the Development of the Evaluation Method in Apartment House (공동주택을 대상으로 한 탄소배출 평가기준 구축 및 평가방법 개발)

  • Choi, Doo-Sung;Chun, Hung-Chan
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.79-88
    • /
    • 2013
  • This study creates the evaluation criteria to analyze the $CO_2$ emission quantity in the complex of apartment house among domestic buildings and proposes how to calculate the $CO_2$ emission quantity by the only simple information of apartment house. The study shows that in order to create the index of carbon emission evaluation criteria, $CO_2$ emission quantity for its input materials in these 27 apartment houses are 445,412g-$CO_2/m^2$ for apartment building, 474,322g-$CO_2/m^2$ for the basement parking lot, 483,523g-$CO_2/m^2$ for welfare facility, 729,957g-$CO_2/m^2$ for sales facility, 743,560g-$CO_2/m^2$ for other facility, 26,782g-$CO_2/m^2$ for public facility, 43,659g-$CO_2/m^2$ for landscape, 1,113g-$CO_2/m^2$ for indoor facility, 11,251g-$CO_2/m^2$ for outdoor facility and 891g-$CO_2/m^2$ for common temporary based on the average $CO_2$ emission by facility. We can also see the analysis data that in case of using the selected factors only, the rate of error is 7.51% comparing with the emission quantity by using simplified LCA method this study suggests for the whole range of apartment houses and the rate of error is average 3.24% using selective and main materials. And this it is evaluated that we can get the result which is similar to the actual $CO_2$ emission quantity with only the simple information about the apartment house.

Analysis of the Characteristic for CO2 Emission Intensity of the Plane Types in Apartments (공동주택 평면유형조합에 따른 시공단계 CO2 배출원단위 특징 분석)

  • Choi, Doo-Sung;Chun, Hung-Chan;Cho, Kyun-Hyong
    • Journal of Korean Living Environment System
    • /
    • v.18 no.3
    • /
    • pp.330-337
    • /
    • 2011
  • This research quantified(/m2) the supplied materials at the construction stage of apartments, the main architecture form domestically, and presented the average CO2 emission by analyzing 50 apartment complexes. The results are as follows. CO2 emission of each type of constructions by supplied materials is architecture (78.8%), machine (8.8%), electricity (5.3%), civil engineering (3.4%), landscaping (3.4%), and communication (1.0%). The building construction charged about 79%. Average CO2 emission of total 50 apartment complexes according to supplied material expense appeared to be 950 kg-CO2/m2, and when core-type pillar was included CO2 emission largely increased.

Effect of Heat Loss on CO and NOx Emission Characteristics in the Postflame Region of Premixed Flames (예혼합 화염후류에서 열전달이 CO 및 NOx 생성 특성에 미치는 영향)

  • Kim, Jong-Min;Kim, Tae-Hyun;Kum, Sung-Min;Kim,, Se-Won;Jang, Gi-Hyun;Lee, Chang-Eon
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • Strict pollutant regulations of NOx emission and increasing awareness of the environmental damage stimulated interest in research to obtain useful information regarding CO and NOx reductions at the same time. In this study, $CH_4$/air premixed flame was examined numerically to reduce CO and NOx emission level simultaneously in the post-flame region by the heat loss models in which radiative and combined conductive and convective heat losses were included. To reduce the NOx emission, first heat exchanger location was decided near the flame. After first heat exchanger was decided for the optimal NOx emission(about 30 ppm), in order to decide the optimal CO emission(about 30ppm), seocond heat exchanger location was tested and decided for several cases. Finally, the optimal location of heat exchanger for minimal CO and NOx emission simultaneously were determined and suggested.

  • PDF

A Study on Energy Consumption and Estimation of CO2 from Re-bar Production (철근 생산과정의 에너지 사용량 및 CO2배출량 산출에 관한 연구)

  • Choi, Jae-Hwi;Lee, Dong-Hoon;Kwon, Gi-Deoc;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.101-109
    • /
    • 2010
  • As global warming progresses, nations around the world are trying to reduce emission of $CO_2$ that accounts for the greatest portion of greenhouse gases. To reduce $CO_2$ emission, it is first necessary to estimate $CO_2$ emission of each industry. Government authorities estimate basic unit of $CO_2$ emission from re-bar that is one of the key materials of construction industry with LCA technique (Life Cycle Assessment). However, basic unit of $CO_2$ emission varies from organization to organization. The Ministry of Land, Transport and Maritime Affairs (2004) publishes it 3.48($TCO_2/ton$) and 0.30($TCO_2/ton$) with input-output analysis while the Korea Environmental Industry & Technology Institute (2008) defines it as 0.34($TCO_2/ton$) with process analysis, which indicates ambiguity in application of basic unit of $CO_2$emission. Based on the analysis of conventional methods used for estimating the $CO_2$ emission, therefore, this research suggests existing problems on the methods and focuses on proposing an strategy to effectively estimate the basic unit of $CO_2$ emission according to the energy consumption limited to the re-bar production in steel mill in order to overcome the problems. The result of this research is expected to be helpful in calculating and reducing $CO_2$ emission.

The Study on Reduction Method of CO2 Emission from Ships (선박에서의 CO2 배출량 저감 방안 연구)

  • Maeda, Kazuyuki;Kim, Young-Un
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.3
    • /
    • pp.705-715
    • /
    • 2013
  • This Paper presented the reduction methods of $CO_2$ emission from ships during voyage. In order to decrease $CO_2$ emission during voyage the equation was established and conducted the study about the relationship between ship speed, the propulsive efficiency and its $CO_2$ production. The results obtained from the examinations are as follows : 1. $CO_2$ emission from sailing ships can be decreased by reducing specific fuel oil consumption of main diesel engine, coefficient of total resistance and ship speed and also by increasing propeller efficiency. 2. Diesel-electric propulsion system is more effective than diesel-mechanical system to decrease the level of $CO_2$ emission during long voyage. 3. Good condition of ship's hull surface, rudder and propeller's surface can decrease the quantity of fuel oil and $CO_2$ emission by reducing the resistance of ship that can rise the propeller efficiency 4. $CO_2$ emitted from ships can be decreased in a global scale by giving attention to the synthetic transport efficiency.