• Title/Summary/Keyword: CNS

Search Result 1,038, Processing Time 0.03 seconds

Detection and Characteristics of Coagulase-Negative Staphylococcus sp. isolated from Dairy Cattle Milk (원유에서 Coagulase-Negative Staphylococci 검출율 및 특징)

  • Kim, Jong-Hui;Kim, Bu-Min;Ham, Jun-Sang;Oh, Mi-hwa
    • Journal of Dairy Science and Biotechnology
    • /
    • v.35 no.3
    • /
    • pp.162-168
    • /
    • 2017
  • Mastitis is a common and serious infection of the mammary gland in dairy cattle and has a major economic impact on the production of milk and dairy products. Bacterial mastitis is caused by several pathogens and is most frequently associated with coagulase-negative staphylococci (CNS). Although CNS are typically associated with subclinical or mild mastitis, the importance of CNS has increased as these pathogens have emerged as predominant mastitis-related pathogens in many countries. CNS can cause persistent infections, resulting in increased milk somatic cell counts and thereby affecting milk quality and decreasing milk production. Globally, Staphylococcus chromogenes, S. epidermidis, and S. simulans are the predominant CNS species in dairy cattle mastitis. Antibacterial resistance of CNS varies with species, and most CNS are susceptible to vancomycin and resistant to penicillin and tetracycline. As the most frequently isolated CNS species, some strains of S. chromogenes exhibit phenotypic resistance to ampicillin, erythromycin, oxacillin, penicillin, and tetracycline. Some strains of S. epidermidis and S. haemolyticus are only susceptible to vancomycin and rifampicin. Therefore, more studies are needed to achieve the control and prevention of CNS as environmental pathogens.

KorQuAD 2.0: Korean QA Dataset for Web Document Machine Comprehension (KorQuAD 2.0: 웹문서 기계독해를 위한 한국어 질의응답 데이터셋)

  • Kim, Youngmin;Lim, Seungyoung;Lee, Hyunjeong;Park, Soyoon;Kim, Myungji
    • Annual Conference on Human and Language Technology
    • /
    • 2019.10a
    • /
    • pp.97-102
    • /
    • 2019
  • KorQuAD 2.0은 총 100,000+ 쌍으로 구성된 한국어 질의응답 데이터셋이다. 기존 질의응답 표준 데이터인 KorQuAD 1.0과의 차이점은 크게 세가지가 있는데 첫 번째는 주어지는 지문이 한두 문단이 아닌 위키백과 한 페이지 전체라는 점이다. 두 번째로 지문에 표와 리스트도 포함되어 있기 때문에 HTML tag로 구조화된 문서에 대한 이해가 필요하다. 마지막으로 답변이 단어 혹은 구의 단위뿐 아니라 문단, 표, 리스트 전체를 포괄하는 긴 영역이 될 수 있다. Baseline 모델로 구글이 오픈소스로 공개한 BERT Multilingual을 활용하여 실험한 결과 F1 스코어 46.0%의 성능을 확인하였다. 이는 사람의 F1 점수 85.7%에 비해 매우 낮은 점수로, 본 데이터가 도전적인 과제임을 알 수 있다. 본 데이터의 공개를 통해 평문에 국한되어 있던 질의응답의 대상을 다양한 길이와 형식을 가진 real world task로 확장하고자 한다.

  • PDF

Event-driven Architecture for Ubiquitous Healthcare (U-Healthcare 분야에서의 EDA 적용 방법)

  • Kim, Eun-kyung;Choi, Eui-yeol;Chang, Yoo-jin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.115-116
    • /
    • 2009
  • EDA는 실시간으로 데이터를 이벤트 형태로 처리할 수 있는 아키텍처로, 최근에 이르러 금융, 공공 분야뿐만 아니라 유비쿼터스 산업과 같은 새로운 산업 분야에 다양하게 활용되고 있다. 본 논문에서는 u-Healthcare 영역에 EDA 활용할 수 있는 방법을 제안하였으며 대표적인 EDA 솔루션이 의료 분야에 적용된 사례를 제시하였다.

Preliminary Design of GBAS Onboard Test Equipment

  • Jeong, Myeong-Sook;Ko, Wan-Jin;Bae, Joong Won;Jun, Hyang Sig
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.1
    • /
    • pp.41-48
    • /
    • 2013
  • When the ground subsystem of Ground Based Augmentation System(GBAS) is installed at the airport, the functions and performance of subsystem should be evaluated through ground and flight testing at the pre-commissioning phase. In the case of GBAS flight testing, it can be conducted by the existing flight check aircraft, but the GBAS ground testing requires the development of specially customized equipment to perform the ground testing. Therefore, this paper describes the preliminary design of GBAS onboard test equipment which can be independently used for the GBAS ground testing and flight testing on a car and an aircraft.

A Study on the Projected Workforce of Nephrology Clinical Nurse Specialist(CNS) in Korea (신장전문간호사 수요추계에 관한 연구)

  • 오복자;신성례
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.2
    • /
    • pp.284-292
    • /
    • 2003
  • Purpose: The purpose of this study was to study the projected workforce of nephrology CNS in Korea. Method: Need models, ratio methods and expert opinion were used for projecting needs for the nephrology CNS. Result: In 2001, there are 28,046 ESRD(end stage of renal disease)patients, 304 renal replacement centers and 1695 nephrology nurses in Korea. the hemodialysis patients per hemodialysis nurse was 12. The number of nephrology CNS required to meet the demand for caring of ESRD patients in 2002, 2005 and 2020 was estimated at 616, 837 and 3105, respectively. 47 ESRD patients per nephrology CNS was revealed as a workforce standard before 2005. After 2005, It was 31 ESRD patients per nephrology CNS. Conclusion: This study founded the need to project future increments and development in supply of qualified nephrology CNS.

Infection Control of Computed Radiography Portable in Radiology (영상의학과 이동촬영장비의 감염 관리)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2017
  • The purpose of this study is to prevent infection in the hospital by computed radiography portable and to provide basic data on infection-related education by investigating bacterial contamination level of computed radiography portable equipment using IP cassette. The results suggest that IP cassette No. 1 is infected with CNS and VRE, no. 2 with CNS, No. 3 with CNS and Pseudomonas aeruginosa, No. 4 with CNS, No. 5 with CNS and Bacillus sp., and No. 6 with enterococcus faecium. Enterococcus faecium and bacillus sp. were detected from the IP reader and Acinetobacter baumannii was detected on the mobile handle; Bacillus sp. on the control buttons, CNS and Bacillus sp. from the irradiation control handle, Acinetobacter baumannii on the x-ray generation switch, and CNS on the barcode scanner. In addition, Bacillus sp. Acinetobacter baumannii was found on the IP cassette mobile table and CNS and bacillus sp. were found on the lead apron. Acinetobacter baumannii and CNS were detected from the medical gloves worn by a radiological technologist during radiography. This suggests that IP cassette should be sterilized after use as it can hand over bacteria to IP reader and IP mobile table. Medical gloves that are in direct contact with patients should also be replaced after using them once and other supplies such as x-ray generation switch and lead apron should thoroughly be sterilized to prevent infection due to radiography as they are in a lot of contact with patients.

Epidemiology of Primary Brain and Central Nervous System Tumors in Korea

  • Lee, Chang-Hyun;Jung, Kyu-Won;Yoo, Heon;Park, So-Hee;Lee, Seung-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Objective : The aim of this report is to provide accurate nationwide epidemiologic data on primary central nervous system (CNS) tumors in Korea. Despite its importance, there are no accurate statistics on primary CNS tumors in Korea. We analyzed primary CNS tumors diagnosed in 2005 from the nationwide registry. Methods : Data on primary CNS tumors diagnosed in 2005 were collected from the Korean Central Cancer Registry and the Korean Brain Tumor Society. Crude and age-standardized rates were calculated in terms of gender, age, and histological type. Tumors of uncertain histology were investigated individually at the corresponding hospitals and had their diagnoses confirmed. Results : A total of 5,692 patients diagnosed with primary CNS tumors in 2005 were included in this study. CNS tumors occurred in females more often than in males (female to male, 1.43 : 1). The most common tumor was meningioma (31.2%). Glioblastoma accounted for 30.7% of all gliomas, and 19.3% of all malignant primary CNS tumors. In children under 19 years of age, both germ cell tumor and embryonal/primitive/medulloblastoma were the most common tumors. Conclusion : This article is the first nationwide primary CNS tumor epidemiology report in Korea. Data from this study should provide valuable information regarding the understanding of primary CNS tumors epidemiology in Korea.

FMEA for CNS Facility and Cause Analysis of Shutdown Events to Improve Reactor Availability (원자로 이용률 향상을 위한 냉중성자원 시설의 고장모드영향분석 및 정지이력의 원인분석)

  • Lee, Yoon-Hwan;Hwang, Jeong Sik
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.115-120
    • /
    • 2020
  • From 2009 when the CNS facility was installed, the number of reactor failures due to abnormal CNS facility system has increased significantly. Of the total of 19 nuclear reactor shutdowns over the six years from 2009 to 2019, there were 10 nuclear reactor shutdowns associated with the CNS facility, which are very numerous. Therefore, this report intends to analyze the history of nuclear reactor shutdowns due to CNS facility system failure in detail, and to present the root cause and solution to problems. As a result of FMEA implementation of CNS facility system, a total of 76 SPVs were selected. In addition, 10 cases of reactor shutdown history due to CNS facility system abnormalities were analyzed in detailed, and improvement plans for solving the root cause and problem were suggested for each trip history. The results of this study are expected to be able to operate the domestic research reactor and CNS facilities more stably by providing effective measures to prevent recurrence of CNS facilities and reactor trips.

Bacteriological Research for the Contamination of Digital Portable Radiography (디지털 이동방사선검사에서의 세균 오염도)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • The study was performed to investigate the bacteriological contamination of portable digital radiography system and their detectors in a university hospital. CNS and VRE were detected in the samples collected from vinyl cover on detectors used for the infection control patients. On the other hand, no bacteria was detected in the samples collected from detectors with vinyl cover removed. In the series of imaging of patients from general wards, no bacteria was detected from the patient 1. However, CNS was detected from the patients 2 and 3, CNS and Enterococcus faecalis detected from the patient 4, CNS and Enterococcus casseliflavus detected from the patient 5, and CNS, Enterococcus casseliflavus, and Klebsiella pneumoniae all detected from the patient 6. CNS and Enterococcus faecium were detected in the controller handle of collimator. Also, CNS was detected from the handle of detector and exposure switch. In the treatment gloves of the radiological technologist after the imaging, CNS, Enterococcus gallinarum, and Klebsiella pneumoniae were detected. Therefore, it is recommended for DR portable to take images after sterilizing the detector after taking each image and to use disposable vinyl covers on detectors to remove after imaging. And treatment gloves must be changed after each imaging. Also, hospital infection via portables must be prevented by complete sterilization of the controller handles of collimator which are in frequent contact during imaging and infection education of employees.