• Title/Summary/Keyword: CNR1

Search Result 289, Processing Time 0.02 seconds

Dose Reduction According to the Exposure Condition in Intervention Procedure : Focus on the Change of Dose Area and Image Quality (인터벤션 시 방사선조사 조건에 따른 선량감소 : 면적선량과 영상화질 변화를 중심으로)

  • Hwang, Jun-Ho;Jung, Ku-Min;Kim, Hyun-Soo;Kang, Byung-Sam;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.393-400
    • /
    • 2017
  • The purpose of this study is to suggest a method to reduce the dose by Analyzing the dose area product (DAP) and image quality according to the change of tube current using NEMA Phantom. The spatial resolution and low contrast resolution were used as evaluation criteria in addition to signal to noise ratio (SNR) and contrast to noise ratio (CNR), which are important image quality parameters of intervention. Tube voltage was fixed at 80 kVp and the amount of tube current was changed to 20, 30, 40, and 50 mAs, and the dose area product and image quality were compared and analyzed. As a result, the dose area product increased from $1066mGycm^2$ to $6160mGycm^2$ to 6 times as the condition increased, while the spatial resolution and low contrast resolution were higher than 20 mAs and 30 mAs, Spatial resolution and low contrast resolution were observed below the evaluation criteria. In addition, the SNR and CNR increased up to 30 mAs, slightly increased at 40 mAs, but not significantly different from the previous one, and decreased at 50 mAs. As a result, the exposure dose significantly increased due to overexposure of the test conditions and the image quality deteriorated in all areas of spatial resolution, low contrast resolution, SNR and CNR.

Adaptation of Deep Learning Image Reconstruction for Pediatric Head CT: A Focus on the Image Quality (소아용 두부 컴퓨터단층촬영에서 딥러닝 영상 재구성 적용: 영상 품질에 대한 고찰)

  • Nim Lee;Hyun-Hae Cho;So Mi Lee;Sun Kyoung You
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.240-252
    • /
    • 2023
  • Purpose To assess the effect of deep learning image reconstruction (DLIR) for head CT in pediatric patients. Materials and Methods We collected 126 pediatric head CT images, which were reconstructed using filtered back projection, iterative reconstruction using adaptive statistical iterative reconstruction (ASiR)-V, and all three levels of DLIR (TrueFidelity; GE Healthcare). Each image set group was divided into four subgroups according to the patients' ages. Clinical and dose-related data were reviewed. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and qualitative parameters, including noise, gray matter-white matter (GM-WM) differentiation, sharpness, artifact, acceptability, and unfamiliar texture change were evaluated and compared. Results The SNR and CNR of each level in each age group increased among strength levels of DLIR. High-level DLIR showed a significantly improved SNR and CNR (p < 0.05). Sequential reduction of noise, improvement of GM-WM differentiation, and improvement of sharpness was noted among strength levels of DLIR. Those of high-level DLIR showed a similar value as that with ASiR-V. Artifact and acceptability did not show a significant difference among the adapted levels of DLIR. Conclusion Adaptation of high-level DLIR for the pediatric head CT can significantly reduce image noise. Modification is needed while processing artifacts.

Optimal Flip Angle for T2-Weighted Effect in Micro 4.7T MRI SE Sequence (마이크로 4.7T MRI SE Sequence에서 T2강조효과를 위한 최적의 Flip Angle)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.113-117
    • /
    • 2019
  • The purpose of this study was to investigate the FA value which can produce the best T2-weighted images by measuring the signal intensity and noise according to the FA value change in the brain image and the abdominal image of the mouse using micro-MRI. Brain imaging and abdominal imaging of BALB / C mice weighing 20g were performed using 4.7T (Bruker BioSpin MRI GmbH) micro-MRI equipment, Turbo RARE-T2 (spin echo-T2) images were scanned at TR 3500 msec and TE 36 msec. The changes of the FA values were $60^{\circ}$, $80^{\circ}$, $100^{\circ}$, $120^{\circ}$, $140^{\circ}$, $160^{\circ}$ and $180^{\circ}$. We measured signal intensity according to FA values of ventricle and thalamus in brain imaging, The signal intensity of kidney and muscle around the kidney was measured in abdominal images. To obtain SNR and CNR, we measured the background signals of two different parts, not the tissue. In the brain (thalamus) image, the signal intensity of FA $100^{\circ}$ was 7,433 and SNR (6.49) was the highest. In the abdominal (kidney) image, the signal intensity was highest at 16,523 when FA was $120^{\circ}$, and the highest SNR was 8.54 when FA was $140^{\circ}$. The CNR value of the brain image was 1.38 at FA $60^{\circ}$ and gradually increased to 8.29 at FA $180^{\circ}$. The CNR value of the muscle adjacent to the kidney gradually increased from 2.36 when the FA value was $60^{\circ}$ and the highest value was 4,57 at the FA value $180^{\circ}$.

Discrimination Energy Range Analysis of Contrast Agents and Calcification using by VNC Application of DECT (DECT의 VNC 적용으로 조영제와 석회화의 식별 에너지 영역 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.179-185
    • /
    • 2024
  • By applying the various energy spectrum imaging functions of DECT, To quantitatively distinguish between contrast agent and calcification, changes in image quality are analyzed by comparing CNR and SNR. We investigated the level of dose reduction during two scans and one VNC scan. As a result, contrast agent and calcification were best distinguished in the 70 keV area, CNR and SNR were excellent, and scan dose was reduced by about 26.5%. Therefore, by applying DECT, meaningful results were obtained that could visually and quantitatively distinguish between the intravascular contrast agent and the shade of calcification. If clinical research is conducted in the future considering the patient's age, gender, and body type, quantitative analysis of calcification will be possible even with intravascular contrast agent flowing in, which will have a significant effect in reducing the patient's scan dose and the burden of multiple scans.

Superconducting Strip Ion Detectors for Time-of-flight Mass Spectrometer

  • Zen, N.;Suzuki, K.;Shiki, S.;Ukibe, M.;Koike, M.;Casaburi, A.;Ejrnaes, M.;Cristiano, R.;Ohkubo, M.
    • Progress in Superconductivity
    • /
    • v.14 no.2
    • /
    • pp.92-95
    • /
    • 2012
  • Superconducting detectors are promising as ion detectors for time-of-flight mass spectrometers (TOF MS). They can achieve mass-independent detection efficiency even for macromolecular bombardments, because output signals are produced through the deposited kinetic energy at ion impact instead of secondary electron emission that is the ion detection mechanism of conventional microchannel plate (MCP) detectors or secondary electron multipliers (SEM). Among the superconducting detectors, the superconducting strip ion detectors (SSIDs), which consist of several hundreds of superconducting lines with a width of a few hundreds nm and a thickness of a few tens of nm, have a fast response time of less than 1 ns. Inherently, the response time of SSIDs is determined by kinetic inductance, so that it was difficult to realize a fast SSID with a large detection area. However, we succeeded in realizing the detector size up to $5{\times}5mm^2$ without response time degradation by using a parallel configuration.

OCCURENCE AND LUMINOSITY FUNCTIONS OF GIANT RADIO HALOS FROM MAGNETO-TURBULENT MODEL

  • CASSANO R.;BRUNETTI G.;SETTI G.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.589-592
    • /
    • 2004
  • We calculate the probability to form giant radio halos (${\~}$ 1 Mpc size) as a function of the mass of the host clusters by using a Statistical Magneto-Turbulent Model (Cassano & Brunetti, these proceedings). We show that the expectations of this model are in good agreement with the observations for viable values of the parameters. In particular, the abrupt increase of the probability to find radio halos in the more massive galaxy clusters ($M {\ge} 2{\times}10^{15} M_{\bigodot}$) can be well reproduced. We calculate the evolution with redshift of such a probability and find that giant radio halos can be powered by particle acceleration due to MHD turbulence up to z${\~}$0.5 in a ACDM cosmology. Finally, we calculate the expected Luminosity Functions of radio halos (RHLFs). At variance with previous studies, the shape of our RHLFs is characterized by the presence of a cut-off at low synchrotron powers which reflects the inefficiency of particle acceleration in the case of less massive galaxy clusters.

Hydrogen Production Using Membrane Reactors

  • Giuseppe Barbieri;Paola Bernardo;Enrico Drioli;Lee, Dong-Wook;Sea, Bong-Kuk;Lee, Kew-Ho
    • Korean Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.68-74
    • /
    • 2003
  • Methane steam reforming (MSR) reaction for hydrogen production was studied in a membrane reactor (MR) using two tubular membranes, one Pd-based and one of porous alumina. A higher methane conversion than the thermodynamic equilibrium for a traditional reactor (TR) was achieved using MRs. The experimental temperature range was 350-500$^{\circ}C$; no sweep-gas was employed during reaction tests to avoid its back-permeation through the membrane and the steam/methane molar feed ratio (m) varied in the range 3.5-5.9. The best results (the difference between the MR conversion and the thermodynamic equilibrium was of about 7%) were achieved with the alumina membrane, working with the highest steam/methane ratio and at 450$^{\circ}C$. Silica membranes prepared at KRICT laboratories were characterized with permeation tests on single gases (N$_2$, H$_2$ and CH$_4$). These membranes are suited for H$_2$ separation at high temperature.

MEMBRANES FOR GAS AND LIQUID SEPARATIONS

  • Golemme, Giovanni;Bove, Lucia;Clarizia, Gabriele;Muzzalupo, Rita;Ranieri, Giuseppe;Nam, Sang-Yong;Drioli, Enrico
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.27-30
    • /
    • 1999
  • Poly(phenylene oxide)s were used to prepare flat, integrally skinned self-supporthed asymmetric membranes by dry-wet phase separption. The intrinsic ideal gas selectivity of poly- (2,6-dimethy-1,4-phenylene oxide) (PMPO) was retained in the membranes, and improved by a coating with silicone rubber. Polymers of the same class were coated of UF supports with a silicon rubber gutter layer, yielding composite membranes with high flux but lower selectivity. The effect of th glutaraldehyde cross-linking of sodium alginate (SA) membranes on the mobility of water and ethanol has been studied with pfg nmr. Crosslinking reduces water self-diffusion, and does not seem to be stable on the timescale of weeks.

  • PDF

Random Signal Characteristics of Super-RENS Disc (Super-RENS Disc의 Random 신호 특성)

  • Bae, Jae-Cheol;Kim, Joo-Ho;Kim, Hyun-Ki;Hwang, In-Oh;Park, Chang-Min;Park, Hyun-Soo;Jung, Moon-Il;Ro, Myong-Do
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.38-42
    • /
    • 2006
  • We report the random pattern characteristics of the super resolution near field structure(Super-RENS) write once read-many(WORM) disc at a blue laser optical system(laser wavelength 405nm, numerical aperture 0.85) and the Super-RENS read only memory(ROM) disc at a blue laser optical system(laser wavelength 659nm, numerical aperture 0.65). We used the WORM disc of which carrier-to-noise ratio(CNR) of 75nm is 47dB and ROM disc of which carrier-to-noise ratio(CNR) of 173nm is 45dB. We controlled the equalization(EQ) characteristics and used advanced partial-response maximum likelihood(PRML) technique. We obtained bit error rate(bER) of 10-3 level at 50GB WORM disc and bite error rate of 10-4 level at 50GB level ROM disc. This result shows high feasibility of Super-RENS technology for practical use.

  • PDF

Evaluation of Noise Level and Blind Quality in CT Images using Advanced Modeled Iterative Reconstruction (ADMIRE) (고급 모델 반복 재구성법 (ADMIRE)을 사용한 CT 영상에서의 노이즈 레벨 및 블라인드 화질 평가)

  • Shim, Jina;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.203-209
    • /
    • 2022
  • One of the typical methods for lowering radiation dose while maintaining image quality of computed tomography (CT) is the use of model-based iterative reconstruction (MBIR). This study is to evaluate the image quality by adjusting the strength of the advanced modeled iterative reconstruction (ADMIRE), which is well known as a representative model of MBIR. The study was conducted using phantom, and CT images were obtained while adjusting the strength of ADMIRE in units of 1 to 5. Quantitative evaluation includes noise levels using coefficient of variation (COV) and contrast to noise ratio (CNR), as well as natural image quality evaluation (NIQE) and blind/referenceless image spatial quality evaluator (BRISQUE). As a result, in both noise level and blind quality evaluation results, the higher the strength of ADMIRE, the better the results were derived. In particular, it was confirmed that COV and CNR were improved 1.89 and 1.75 times at ADMIRE 5 compared to ADMIRE 1, respectively, and NIQE and BRISQUE were proved to be improved 1.35 and 1.22 times at ADMIRE 5 compared to ADMIRE 1, respectively. In conclusion, this study was proved that the reconstruction strength of ADMIRE had a great influence on the noise level and overall image quality evaluation of CT images.