• Title/Summary/Keyword: CN Method

Search Result 347, Processing Time 0.025 seconds

A Study on the Simultaneous Determination of Residual Zeranol, Zearalenone and Their Metabolites in Beef by Gas Chromatography/Mass Spectrometry (Gas Chromatography/Mass Spectrometry에 의한 우육 중의 잔류 Zeranol, Zearalenone 및 그 대사산물들의 동시 분석법에 대한 연구)

  • 이은섭;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 1994
  • A Simultaneous determination method was improved for the determination and confirmation of zeranol, zearalenone, as well as their isomers and metabolites, in beef. The analytes were extracted from tissue by CH3CN, hydrolyzed enzymatically(for glucuronide conjugates), cleaned up by a strong basic anion exchange resin combined with a liquid/liquid partitioning, derivatized using MSTFA and confirmed, quantified by GC/MS/SIM with a internal standard, zearalane. The results were as follows : (1) all the estrogens were separated on the GC/MS chromatogram under the extraction method and the chromatographic conditions improved, the retention times of zearalane-TMS2, zearalanone-TMS2, zearalenone-TMS2, zeranol-TMS3, taleranol-TMS3, and $\alpha$-zearalenol-TMS3, $\beta$-zearalenol-TMS3, were 18.49, 19.44, 19.63, 19.71, 19.79 and 19.99, 20.08 minutes, respectively. (2) The calibration curves of residual zeranol, zearalenone and their metabolites showed constantly linear(r=0.99) in the range of 5~20 ng. The minimum detection concentration of residual zeranol, zearalenone and their metabolites was 1 ppb. (3) The total average recovery of residual zeranol, zearalenone and their metabolites from spiked beef was 60.2%(CV=29.7%) at the 1 ppb and 63.5%(CV=26.5) at the 2 ppb, 72.9%(CV=18.2%) at the 4 ppb. (4) The preservation method for 6 estrogens was improved for the fast running time(21 min) and MSTFA was utilized for derivatizing 6 estrogens for improvement of recovery, for good resolution, for characteristic mass spectra unlike Jose's method and Tina's method. The utilization of zearalane as internal standard showed good quantification result for zeranol, zearalenone, as well as their isomers and metabolites, in beef.

  • PDF

Estimation of Flood Discharge Based on Observation Data Considering the Hydrological Characteristics of the Han Stream Basin in Jeju Island (한천유역의 수문학적 특성을 고려한 관측자료 기반 홍수량 산정)

  • Yang, Sung-Kee;Kim, Min-Chul;Kang, Bo-Seong;Kim, Yong-Seok;Kang, Myung-Soo
    • Journal of Environmental Science International
    • /
    • v.26 no.12
    • /
    • pp.1321-1331
    • /
    • 2017
  • This study reviewed the applicability of the existing flood discharge calculation method on Jeju Island Han Stream and compared this method with observation results by improving the mediating variables for the Han Stream. The results were as follows. First, when the rain-discharge status of the Han Stream was analyzed using the flood discharge calculation method of the existing design (2012), the result was smaller than the observed flood discharge and the flood hydrograph differed. The result of the flood discharge calculation corrected for the curve number based on the terrain gradient showed an improvement of 1.47 - 6.47% from the existing flood discharge, and flood discharge was improved by 4.39 - 16.67% after applying the new reached time. In addition, the sub-basin was set separately to calculate the flood discharge, which yielded an improvement of 9.92 - 32.96% from the existing method. In particular, the steepness and rainfall-discharge characteristics of Han Stream were considered in the reaching time, and the sub-basin was separated to calculate the flood discharge, which resulted in an error rate of -8.77 to 8.71%, showing a large improvement of 7.31 - 28.79% from the existing method. The flood hydrograph also showed a similar tendency.

Rapid Determination of Electroplating Solutions (1) -Copper from Copper Plating Solutions (각종 도금액의 신속분석법 (제 1 보))

  • 염희택
    • Journal of the Korean institute of surface engineering
    • /
    • v.1 no.1
    • /
    • pp.5-13
    • /
    • 1967
  • Up to this date, numerous methods of analysis of electropling solutions are published. Some, however, need lots of works before reaching final results, or require high technique and special instruments, and also some are unaccurate due to unclearnes of end point. Like our undevelop countries, technicians of electroplating shops are most high school graduates or under, and have not much knowledge on chemistry. Furthermore, those technicians have to control their plating solutions by themselves without having enough analytical laboratory equipment . Therefore, in this paper the simplest, besides accurate method is investigated after comparing numerous methods published. Among the methods of copper determinations from acid and alkaline copper plating baths, EDTA titration method are chosen, due to these methods are the simpest and fastest for the evaluation of metal content, without requirng any special instrument. For acid copper solutions, chelate titrations were accurate enough. Since the end point of titration of chelate method is variable according to the kind of indicators and other metal's coexisitence as well as solution component, many difficulties were encountered from cyanide copper, on the contrary of acid copper bath. PAN , PV, and MX indicators were tried , but it is found that MX is the best. In chyanide solution ,due to cyanide is the masking reagent , elimination of this component is essential , and finally found that elimination CN-by precipitation with AgNO$_3$ solution was the simplest and the most accurate way among others. This method was very accurate for the new plating solutions even coexistence with organic brightners. However used solutions for long months running have to be predetermined the accurate copper value by thiosulfate method form time to time, before chelate titration by means of AgNO$_3$ precipitation. Always some constant deviations will be seen according to the solutions nature. Therefore those deviation values have to be compensated each time.

  • PDF

Pharmacokinetic Study of Promethazine in Korean Healthy Subjects Using a Validated HPLC Method

  • Jang, Jung-Ok;Go, Eun-Jung;Kim, Na-Hyung;Chung, Soo-Yeon;Park, Hyo-Min;Lee, Hwa-Jeong
    • Biomolecules & Therapeutics
    • /
    • v.13 no.2
    • /
    • pp.118-122
    • /
    • 2005
  • The objective of the present investigation was to study pharmacokinetics of promethazine in Korean healthy subjects using a validated HPLC method. The HPLC analysis was performed on a Capcell Pak CN column with a mixture of acetonitrile-0.02M potassium dihydrogen phosphate (42:58, v/v, pH 6.0) and the analyte was quantified with UV detection at 251 nm. The calibration curve of the drug was linear over the range of 1-40ng/mL in human serum and the limit of quantification (LOQ) was 1 ng/mL. This analytical method was validated and shown to be specific, accurate, precise and reproducible. This method was applied to pharmacokinetic study of promethazine in Korean healthy volunteers following an oral administration of two 25 mg Himazin tablets (50 mg promethazine ${\cdot}$HCI) after overnight fasting. Serum samples were collected at given intervals over a 36-hour period (12 points) and pharmacokinetic parameters were determined from serum concentration-time profile using WinNonlin program. The estimated $AUC_{0__\infty}$, $AUC_{0_\infty}$, $C_{max}$, $T_{max}$ and $t_{1/2}$ of promethazine obtained from Korean healthy subjects were 103.84 ${\pm}$84.30 ng${\cdot}$hr/mL, 87.94${\pm}$81.02 ng${\cdot}$hr/mL, 13.43${\pm}$10.92 ng/mL, 2.00${\pm}$1.16 hr and 5.88${\pm}$3.47 hr, respectively.

A Sensitivity Analysis of Model Parameters involved in Clark Method on the Magnitude of Design Flood for urban Watersheds (CLARK 유역추적법에 의한 계획홍수량 산정에 미치는 매개변수의 민감도 분석)

  • Yoon, Kwang-Wonn;Wone, Seog-Yeon;Yoon, Yong-Nam
    • Water for future
    • /
    • v.27 no.4
    • /
    • pp.85-94
    • /
    • 1994
  • A Sensitivity analysis on the model parameters involved in the Clark watershed routing method is made to demonstrate the effect of each parameter on the magnitude of 50-year design flood for small urban streams. As for the rainfall parameter the time distribution pattern of design storm was selected. For short duration storms Huff, Yen & Chow and Japanese Central type distributions were selected and the Mononobe distribution of 24-hour design storm was also selected and tested for Clark method application. The effect of SCS runoff curve number for effective rainfall and the methods of subbasin division for time-area curve were also tested. The routing parameter, i.e. the storage constant(K), was found to be the dominating parameter once design storm is selected. A multiple regression formula for K correlated with the drainage area and main channel slope of the basin is proposed for the use in urban stream practice for the determination of design flood by Clark method.

  • PDF

Determination of saikosaponin derivatives in Bupleuri Radix using HPLC-ELSD (HPLC-ELSD를 이용한 시호 중의 saikosaponin 유도체의 확인법 개발)

  • Kim, Bo-Mi;Yoon, Kee-Dong;Han, Kyung-Reem;Kim, Jin-Woong
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • A HPLC-ELSD method was developed to determine saikosaponin derivatives from Bupleuri Radix. Eight saikosaponins, saikosaponin c, i, h, a, $b_2$, g, $b_1$ and d, were analyzed under optimized HPLC conditions [column: Eclipse XDB $C_{18}$ ($150{\times}4.6mm$ i.d., $5{\mu}m$; mobile phase: $H_2O$ with 0.1% $CH_3$COOH (v/v) for solvent A and AcCN with 0.1% $CH_3$COOH (v/v) for solvent B, gradient elution; flow rate: 1mL/min; injection volume: $20{\mu}L$]. Good linearity was achieved in the range from 62.5 to $250{\mu}g/mL$ for each compound, and intra-day precision and accuracy at each concentration level varied between 0.05 and 5.45% and between 93.9 and 109.6%, respectively, whereas those for inter-day variations were between 0.91 to 2.73% and 94.3 to 106.1%. This HPLC-ELSD method was applied for the determination of sakosaponins from Bupleuri Radix samples, and saikosaponin a $(0.79{\pm}0.20mg/g)$, c $(0.33{\pm}0.06mg/g)$ and d $(0.48{\pm}0.15mg/g)$ were observed as major compounds. The other saikosaponins were shown under limit of quantification level thus couldn't be quantified. The present study suggested that the introduced HPLC-ELSD method is selective and reliable, and not only saikosaponin a, but also saikosaponin c and d should be employed as the standard markers for Bupleuri Radix.

Estimation of Design Flood Runoff in Ungaged Forest Watershed to Reduce Flood Damage within the National Park (국립공원내 홍수피해 저감을 위한 미계측 산림지역의 설계홍수량 추정)

  • Kim, Sang-Min;Im, Sang-Jun;Lee, Sang-Ho;Kim, Hyung-Ho;Ma, Ho-Seop;Jeong, Won-Ok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.107-113
    • /
    • 2009
  • The purpose of this study is to estimate the design flood runoff for ungaged forest watershed to reduce the flood damage in national park. Daewonsa watershed in Jirisan National Park was selected as study watershed, of which characteristic factors were obtained from GIS data. Flood runoff was simulated using SCS unit hydrograph module in HEC-HMS model. SCS Curve Number (CN) was calculated from forest type area weighted average method. Huff's time distribution of second-quartile storm of the Sancheong weather station, which is nearest from study watershed, was used for design flood runoff estimation. Critical storm duration for the study watershed was 3 hrs. Based on the critical duration, the peak runoff for each sub-watershed were simulated. It is recommended to monitor the long-term flow data for major stream stations in National Park for a better reliable peak runoff simulation results.

Analysis of Genetic Characteristics of Korean Native Chicken Using DNA Marker (DNA Marker를 이용한 한국 재래닭의 유전특성 분석)

  • 이학교;이성진;황규춘;정일정;박용호;손시환;신영수;오봉국;한재용
    • Korean Journal of Poultry Science
    • /
    • v.23 no.4
    • /
    • pp.177-183
    • /
    • 1996
  • This study was conducted to analyze genetic characteristics of Korean Native Chicken three lines classified on the basis of the feather color and appearance (Red, Yellow, and Black) using DNA fingerprinting method. To estimate the genetic relatedness among breeds and similarities within breeds, we collected blood samples from Korean Native Chicken (KNC), Rhode Island Red (RIR), White Leghorn (WL), and Cornish(CN) and obtained genomic DNA from the blood of 10 individuals randomly selected within the breeds and lines. The genomic DNA samples were digested with restriction enzymes (Hinf J, Hae Ill) and hybridized with various probes (Jeffreys' probes 33.15, 33.6 and M13) after Southern transfer. Genetic similarities within breeds were characterized by band sharing (BS) value, estimated by the DFP band pattern between the pair of lanes. BS values within WL, RIR, and KNC were 0.82, 0.70 and 0.56, respectively. Relative genetic diversity (BS value) of KNC was higher than those two breeds (WL, RIR). Estimation of genetic similarity between KNC lines and control breed (RIR) was 0.32, whereas similarity within KNC lines (6 groups) was 0.50. In this analysis, KNC was showed to have a highly genetic diver-sity at the DNA level, and to be closer in genetic distance to RIR (0.67) than any other breeds.

  • PDF

Postsolving in interior-point methods (내부점 선형계획법에서의 사후처리)

  • 이상욱;임성묵;성명기;박순달
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.11a
    • /
    • pp.89-92
    • /
    • 2003
  • It is often that a large-scale linear programming(LP) problem may contain many constraints which are redundant or cause infeasibility on account of inefficient formulation or some errors in data input. Presolving or preprocessing is a series of operations which removes the underlying redundancy or detects infeasibility in the given LP problem. It is essential for the speedup of an LP system solving large-scale problems to implement presolving techniques. For the recovery of an optimal solution for the original problem from an optimal solution for the presolved problem, a special procedure, so called postsolving, must be applied. In this paper, we present how a postsolving procedure is constructed and implemented in LPABO, a interior-point based LP system. Briefly, all presolving processes are logged in a data structure in LPABO, and after the end of the solution method an optimal solution for the original problem is obtained by tracing the logs. In each stage of the postsolving procedure, the optimality of intermediate solutions is maintained. We tested our postsolving procedure on Netlib, Gondzio and Kennington LP data sets, and concluded that the computational burden of the procedure is relatively negligible compared with the total solving time.

  • PDF

Superconducting property in the Zn substituted MgC$Ni_3$ (Zn로 치환된 MgCN $i_3$의 초전도 특성)

  • 이용우;김진수;박민석;이성익;심지훈;민병일;최은집
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.144-147
    • /
    • 2003
  • We investigated superconducting property of ($Mg_{1-x}$$Zn_{x}$)$CNi_3$ (x=0,0.03, 0.06, 0.09, 0.12, 0.15, and 0.18) sample where Mg is substituted with Zn. The samples were synthesized us ins the solid state reaction method under As atmosphere. X -ray diffraction spectra show that the $MgCNi_3$ structure is maintained up to x=18. With increasing x, the lattice constant (or the Ni-Ni distance) decreases. Magnetic susceptibility measurement shows that $T_{c}$ decreases systematically with x and becomes ~2K at x =0.18. Surprisingly, the transition width remains sharp (~0.3K). Under some assumptions, we estimate the coupling constant in the McMillan formula as a function of x which we interpret in terms of the BCS theory.y.y.y.

  • PDF