• Title/Summary/Keyword: CIM(Current Injection Method)

Search Result 8, Processing Time 0.019 seconds

Charge-Pump High Voltage Inverter for Plasma Backlight using Current Injection Method (CIM(Current Injection Method)을 이용한 Charge-Pump 방식의 Plasma Backlight용 고압Inverter)

  • Jang, Jun-Ho;Kang, Shin-Ho;Lee, Kyung-In;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.386-393
    • /
    • 2007
  • Charge-pump high voltage inverter for Plasma backlight using CIM(Current Injection Method) is proposed in this paper. Adoption of ERC(Energy Recovery Circuit) is a new attempt in high voltage inverter so that it is not only energy recovery but also improvement of discharge stability and system unstability which is interrupted by noise. Using a charge-pump technique enables low voltage switches to be usable, the cost can be reduced. CIM is adopted to achieve high speed energy recovery in proposed circuit. Operations of the proposed circuit are analyzed for each mode. The proposed circuit is verified to be applicable on a 32 inch plasma backlight panel by experimental results.

CIM Based Zero Voltage Switching of Energy Recovery Sustain Driver for AC PDPs with Reduced Sustain Voltage (CIM을 이용한 유지구동전압 반감형 AC PDP용 에너지 회수 구동회로의 영전압 스위칭)

  • Lim, Seung-Bum;Jung, Dae-Tack;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.378-385
    • /
    • 2007
  • AC PDP has disadvantages that power consumption and sustain voltage are high. An energy recovery circuit for AC PDPs with reduced sustain voltage was proposed to solve these disadvantages. However, the circuit has disadvantage that the switching elements are performed hard switching at the start point of discharge and sustaining region. The reason is that the panel voltage is lower than sustain voltage at that point. In this paper, we propose the improved driving method that switching devices are operated with ZVS by using CIM(Current Infection Method) also at that point. CIM region is designed by theoretical circuit analysis. Finally, the validity of the proposed driving method is verified by the simulations and experimentation.

Charge-Pump High Voltage Inverter for Plasma Backlight with Current Injection Method (CIM(Current Injection Method)을 이용한 Charge-Pump 방식의 Plasma Backlight용 고압 Inverter)

  • Jang, Jun-Ho;Kang, Shin-Ho;Lee, Jun-Young
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.381-383
    • /
    • 2007
  • Charge-pump high voltage inverter for Plasma backlight with CIM(Current Injection Method) is proposed in this paper. Adoption of ERC is a new attempt in high voltage inverter so that it is not only energy recovery but also improvement of discharge stability and system unstability which is interrupted by noise. Using a charge-pump technique enables low voltage switches to be usable, the cost can be reduce. CIM is adopted to achieve high speed energy recovery in proposed circuit. Operations of the proposed circuit are analyzed for each mode. The proposed circuit is verified to be applicable on a 32 inch plasma backlight panel by experimental results.

  • PDF

A Novel Multi-Level Type Energy Recovery Sustaining Driver for AC Plasma Display Panel (새로운 AC PDP용 멀티레벨 에너지 회수회로)

  • Hong, Soon-Chang;Jung, Woo-Chong;Kang, Kyoung-Woo;Yoo, Jong-Gul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.71-78
    • /
    • 2005
  • This paper proposes a novel multi-level energy recovery sustaining driver for AC PDP(Plasma Display Panel), which solves the problems of the conventional multi-level sustaining driver. While the conventional circuit improves the voltage md current stress of the switching elements in Weber circuit not only there are parasitic resonant currents between resonant inductors and parasitic capacitance and hard switching, but also the changing period between 0 and sustain voltage is too long. Comparing the proposed circuit with the conventional circuit, the number of components are reduced and the parasitic resonant currents in resonant inductors are eliminated Moreover the hard switching problem is solved by using CIM(Current Injection Method) and the operating frequency will be high as much as possible by removing Vs/2 sustain period. And the circuit operations of the proposed circuit are analyzed for each mode and the validity is verified by the simulations using PSpice program.

New Energy Recovery Concept for AC PDP Sustaining Driver Using Current Injection Method (CIM)

  • Lee, Jun-Young;Kim, Jin-Sung;So, Myeong-Seop;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.189-198
    • /
    • 2002
  • New concept of energy recovery for plasma display panel (PDP) Is proposed. Different from conventional LC resonant sustaining drivers, the current built up before inverting the polarity of the panel electrodes is utilized to change the panel Polarity together with energy Previously charged in Panel capacitance. This operation Provides zero -voltage-switching of switches and reduction of EMI by rejecting the surge current when the sustain switches are turned on. The build-up current helps to reduce transition time of panel polarity and may produce more stable light waveforms. This method shows a desirable characteristic that the circuit loss is similar to that of series resonant type energy recovery circuit which is very effective method.

A Study on the NPC Type Multi-Level Energy Recovery Sustaining Driver for AC Plasma Display Panel (AC PDP용 NPC 타입 멀티레벨 에너지 회수회로에 관한 연구)

  • Yoo Jong-Gul;Hong Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.194-202
    • /
    • 2005
  • This paper proposes a new multi-level energy recovery sustaining driver for AC PDP(Plasma Display Panel), which solves the problems and maintains the merits of the conventional multi-level sustaining driver. While the conventional circuit improves the hard switching in the Weber circuit, there exist parasitic resonant currents in resonant inductors and Vs/2 sustaining period. Comparing the proposed circuit with the conventional circuit, the number of inductors are reduced by half, the parasitic resonant currents in resonant inductors are eliminated, and the hard switching problem is solved by CIM(Current Injection Method). Moreover the voltages across series-connected switching elements in the full bridge circuit are distributed equally by adopting NPC(Neutral Point Clamping) techniques. And circuit operations of the proposed circuit are analyzed for each mode and the validity is verified by the simulations using PSpice program and experimentation with a prototype drive circuit.

A Study on the Enhancement of Available Transfer Capability Using the Flexible AC Transmission System (FACTS)

  • Gim, Jae-Hyeon;Kim, Yang-Il;Jeung, Sung-Won
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.192-200
    • /
    • 2004
  • This paper evaluates FACTS control on the available transfer capability (ATC) enhancement. Technical merits of FACTS technology on boosting ATC are analyzed. More effective control means for line flow and bus voltage require the application of FACTS. In this paper, the power flow calculation method for the power systems with FACTS is based on the current injection model (CIM) and the Newton-Raphson method. An integrated scheme for ATC calculation, which considers the dynamic characteristic of the power system, is suggested. The study is applied to the IEEE 57-bus power system to demonstrate the effectiveness of FACTS control on ATC enhancement.

A Study on Enhancement Available Transfer Capability Using Flexible AC Transmission System (FACTS) (FACTS를 이용한 지역간 융통전력 증대방안에 관한 연구)

  • 김양일;정성원;기경현;김재현
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.8
    • /
    • pp.446-453
    • /
    • 2004
  • This paper focuses on the evaluation of FACTS control on available transfer capability(ATC) enhancement. Technical merit of FACTS technology on ATC boosting are analyzed. More effective control means for line flow and bus voltage are required for appling FACTS. In this paper, the power flow calculation method for deriving FACTS control parameters based on current injection model(CIM) and newton method. Integrated scheme for ATC calculation considering dynamic characteristic of power system is suggested. Study is based on the IEEE 57-bus system demonstrate the effectiveness of FACTS control on ATC enhancement.