• 제목/요약/키워드: CHANGE OF THE DENSITY

검색결과 2,991건 처리시간 0.038초

The piezoelectricity of trabecular bone in cancellous bone wave propagation

  • Yoon, Young June;Chung, Jae Pil
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.104-107
    • /
    • 2021
  • The orientation of trabeculae and porosity determine the wave propagation in cancellous bone. Wave propagation, as well as charge density and piezoelectricity, stimulate bone remodeling. Also, Charged ions in the fluid affect wave propagation in cancellous bone. But the trabecular struts' piezoelectricity does not change the waveform of cancellous bone. However, the underlying mechanism is unknown yet why trabecula struts' piezoelectricity does not change wave propagation through cancellous bone. Thus, we derived the governing equation indicating that trabecular struts' piezoelectric properties show that those do not affect wave propagation in cancellous bone.

허리뼈 회전과 기울기에 따른 골밀도 분석 (Analysis of Bone Mineral Density According to Lumbar Spine Rotation and Inclination)

  • 제재용
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.779-783
    • /
    • 2019
  • 골다공증은 골절의 위험도가 증가하는 질환으로, 본 연구에서는 이중에너지 엑스선 흡수계측법(DXA)을 이용하여 허리뼈의 회전과 기울기에 따른 골밀도를 비교 분석하였다. 실험 결과 허리뼈의 회전에 따른 골밀도는 감소하지만 허리뼈의 기울기 변화에서는 그 결과는 예측할 수 없었다. 이러한 이유는 허리뼈의 기울기 변화가 허리뼈 1번과 4번사이 일부분에서 겹침으로 인하여 뼈의 전체 면적과 골밀도가 변화한 결과로 판단되어진다. 즉, 방사선사는 정확한 골밀도 결과 값을 얻기 위하여 허리뼈의 회전방지와 기울기에 따른 겹침을 방지하기 위한 노력이 필요할 것으로 판단되어진다.

The analysis of neutral particle in Mercury discharge lamp

  • Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2421-2423
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm $(6^3S_1{\rightarrow }6^3P_2)$ were larger than 404.8nm $(6^3S_1{\rightarrow}6^3P_1)$. According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

LIF를 이용한 Hg-Ar(1Torr)의 플라즈마 밀도 측정 (Plasma Density Measurement of the Hg-Ar(1Torr) by LIF Method)

  • 이종찬;박대희;양종경
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.213-217
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely This highlights the importance of measuring density distribution in plasma electric discharge mechanism study The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1 {\to} 6^3P_2$ ) were larger than 404.8nm ($6^3S_1 {\to} 6^3P_1$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

LIF를 이용한 Hg-Ar의 플라즈마 밀도 측정 (Plasma Density Measurement of Hg-Ar by LIF Method)

  • 최용성;황종선;박계춘;송민종;김형곤;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.27-32
    • /
    • 2006
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely. This highlights the importance of measuring density distribution in plasma electric discharge mechanism study. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorcscent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1{\rightarrow}6^3P_2$) were larger than 404.8nm ($6^3S_1{\rightarrow}6^3P_2$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

영동지역 활엽수림에서의 강우 후 지표연료의 습도변화 분석 (Comparison of Surface Fuel and Soil Layer Moisture after Rainfall in Broad-Leaved Forest at Young Dong Region)

  • 권춘근;이시영;이해평
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.49-60
    • /
    • 2012
  • 강우 후 경과일수에 따른 연료습도 변화는 산불위험도 예측과 산불감시원 활용에 매우 중요하다. 따라서 이러한 산불발생위험 조건을 구명하기 위해 2008, 2009년 봄 가을철 영동지역 활엽수림에서 임분 밀도별로 5.0 mm 이상 강우 후 낙엽층, 부식층, 토양층, 직경별 지표연료 0.6 cm 이하, 0.6~3.0 cm, 3.0~6.0 cm, 6.0 cm 이상에 대한 산불위험도를 분석하였다. 연구결과 봄철 낙엽층의 소임분 지역은 강우 3일 후부터, 중 밀임분 지역은 5일 후부터 산불발생 위험수준인 17 % 정도의 연료 습도를 나타냈다. 반면, 부식층은 계절에 상관없이 6일이 경과 되어도 40 % 이상의 연료 습도를 나타냈으나, 토양 상 하층은 미비한 변화가 있었다. 봄철 직경별 지표연료 0.6 cm 이하의 소임분 지역은 강우 3일 후부터, 중 밀임분 지역은 4일후부터 산불발생 위험수준 연료습도를 나타냈고, 가을철 직경별 지표연료 0.6~3.0 cm의 소임분 지역은 강우 3일 후부터, 중 밀임분 지역은 5일 후부터 산불발생 위험수준의 연료습도를 나타냈다. 봄 가을철 직경별 지표연료 3.0~6.0 cm의 경우 6일차가 되어도 소, 중, 밀임분 공히 높은 연료습도를 유지하고 있어 산불위험성은 매우 적은 것으로 조사되었으며, 6.0 cm 이상의 경우 계절에 상관없이 6일이 경과되어도 25 % 이상의 연료 습도를 나타냈다.

Design and Analysis of the Eddy Current Brake with the Winding Change

  • Cho, Sooyoung;Liu, Huai-Cong;Lee, Ju;Lee, Chang-Moo;Go, Sung-Chul;Ham, Sang-Hwan;Woo, Jong-Hyuk;Lee, Hyung-Woo
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.23-28
    • /
    • 2017
  • This paper is a study of the eddy current brake designed to replace the air brake of railway application. The eddy current brake has the advantage of being able to take a high current density compared to the other application because this brake is used for applying brakes to the rolling stock for a shorter amount of time. Also, this braking system has the merit of being able to take a high current density at low speed rather than at high speed, because the heat generated by the low speed operation is less than that of the high speed operation. This paper also presents a method of improving the output torque of the eddy current brake at low speed operation through a change of the winding as well as the basic design.

Chlorella vulgaris의 당류 능동수송계에 미치는 칼슘 이온의 영향 (Calcium Ion Effect on the Sugar-H+ -Cotransport System in Chlorella vulgaris)

  • 조봉희
    • Journal of Plant Biology
    • /
    • 제36권4호
    • /
    • pp.321-326
    • /
    • 1993
  • Sugar uptake is accompanied with H+-substrate-symport generally. Both H+/sugar-and H+/K+ stoichiometries during the sugar-uptake have been reported to be exactly 1 : 1. This paper reports that the stoichiometries were enhanced dramatically by the addition of CaCl2 into the medium and by the high cell density of 200 $\mu$L pc/mL. The concentration of free Ca2+ ions in the cells increased significantly with cell density. It is suggested that the free Ca2+ ions are responsible for the change of stoichiometry of sugar transport system by regulation of H+ ion level of biomembrane.

  • PDF

피로인산염욕을 사용한 은-주석 합금도금층의 조성 및 현미경 조직 (Composition and microstructure of Silver-Tin alloy deposits from prophosphate bath)

  • 예길촌;김용웅;김진수
    • 한국표면공학회지
    • /
    • 제26권3호
    • /
    • pp.143-148
    • /
    • 1993
  • Composition and microstructures of Silver-Tin alloy deposits from a pyrophosphate bath were studied under the D.C. electrolysis conditions. Cathode current efficiency and throwing power of alloy deposits de-creased with increasing current density. Tin content of Ag-Sn alloy deposits decreased noticeably with the cur-rent density and with decreasing pH. The preferred orientation of the deposits tended to change in sequence of (110)longrightarrow(111)longrightarrow(100) texture with increasing the cathode overpotential. The surface structure of alloy deposits showed the smooth surface structure with fine crystallites.

  • PDF

전기응집을 이용한 소규모 수도시설의 질산성질소와 불소이온 제거 (Fluoride and nitrate removal in small water treatment plants using electro-coagulation)

  • 한송희;장인성
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.767-775
    • /
    • 2011
  • In this study we verified if the electro-coagulation process can treat properly the nitrate and fluoride that are not removed well in the conventional small water treatment plants which usually employ chlorination and filtration only. As we gave a change of electrode material and gap-distance between electrodes, removal efficiency of the nitrate and fluoride was determined by electro-coagulation process which were equipped with aluminum and stainless steel (SUS304) electrodes. In addition, electrode durability was investigated by determination of electrodes mass change during the repetitive experiments. Removal efficiency was great when aluminum was used as an anode material. Nitrate removals increased as electric density and number of electrodes increased, but fluoride removal was less sensitive to both parameters than nitrate. After 10 minutes of contact time with the current density from $1{\times}10^{-3}$ to $3{\times}10^{-3}A/cm^{2}$, nitrate and fluoride concentration ranged from 9.2 to 1.2mg/L and from 0.02 to 0.01mg/L, which satisfied the regulation limits. Regardless of the repeating number of experiments, removal efficiency of both ions were almost similar and the change of electrode mass ranged within ${\pm}$0.5%, indicating that the loss of the electrode mass is not so much great under the limited circumstances.