• Title/Summary/Keyword: CF4 가스

Search Result 91, Processing Time 0.029 seconds

Effect of Mixed Gases on Decomposition Characteristic of CF4 by Non-Thermal Plasma (비열플라즈마를 이용한 CF4 분해에 미치는 혼합가스의 영향)

  • 박재윤;정장근;김종석;임근희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.6
    • /
    • pp.543-550
    • /
    • 2002
  • In this paper, the $CF_4$ decomposition rate and by-product were investigated for two simulated plasma reactors which are metal particle reactor and spiral wire reactors as a function of mixed gases. The $CF_4$ decomposition rate by plasma reactor with metal particle electrode had a gain of 20~25% over that by plasma reactor with spiral wire electrode. The $CF_4$ decomposition efficiency increases with increasing applied voltage up to the critical voltage for spark formation. The $CF_4$ decomposition efficiency of metal particle reactor was about 80% at AC 24kV. The $CF_4$ decomposition rate used Ar-$N_2$ as base gas was the highest among three base gases of $N_2$, $Ar-N_2$, air. The by-products of the $N_2$, $N_2Ar$ base as were similar, but in case of air base they were different.

CF4/O2 혼합가스 플라즈마 환경에 대한 AAO (Anodic Aluminum oxide) 피막의 오염입자 특성 분석

  • Lee, Seung-Su;Choe, Sin-Ho;O, Eun-Sun;Sin, Jae-Su;Kim, Jin-Tae;Yun, Ju-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.102.1-102.1
    • /
    • 2015
  • 플라즈마를 이용한 건식식각공정은 식각하고자 하는 기판과 더불어 챔버 내부를 구성하고 있는 부품들이 플라즈마에 함께 노출되는 환경이다. 챔버 내부가 장시간 플라즈마에 노출되어 열화 되면 기판의 불량을 야기하는 오염입자의 발생이 증가하므로 양산 공정에서는 그 때마다 내부 부품을 교체하여 청정한 공정 환경을 유지시킨다. 공정 챔버의 내부 부품은 플라즈마로 인한 열화를 방지하기 위하여 내플라즈마성이 우수하다고 알려진 코팅처리를 하여 사용한다. 금까지 플라즈마 식각 공정에 관한 연구는 식각하고자 하는 기판관점에서 활발히 이루어져 왔으나 내플라즈마성 코팅소재 관점에서의 연구 보고는 미미한 실정이다. 본 연구에서는 장시간의 양산공정을 모사하는 가혹한 플라즈마 조건에서 $CF_4/O_2$ 혼합가스를 사용하여 AAO (Anodic Aluminum oxide)피막의 오염입자 특성을 실시간 모니터링 하는 동시에 OES 분석을 수행하여 내플라즈마성 코팅소재의 오염입자 발생 메커니즘에 대하여 분석하였다.

  • PDF

The study of electron transport coefficients in pure $CF_4$ by 2-term approximation of the Boltzmann equation (2항근사 볼츠만 방정식을 이용한 $CF_4$분자가스의 전자수송계수의 해석)

  • Jeon, Byung-Hoon;Ha, Sung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.29-32
    • /
    • 2001
  • We measured the electron transport coefficients(the electron drift velocity, W, and the longitudinal diffusion coefficient, $D_L$) in pure $CF_4$ over the E/N range from 0.04 Td to 250 Td by the double shutter drift tube. And these electron transport coefficients in pure $CF_4$ were calculated over the E/N range from 0.01 to 250 Td at 1 Torr by using the two-term approximation of the Boltzmann equation.

  • PDF

Breakdown Characteristics of $SF_6/CF_4$ Mixtures under AC Voltages in Uniform, Nonuniform Field (평등, 불평등 전계에서 AC전압의 $SF_6/CF_4$ 혼합가스 절연내력 특성)

  • Sung, Heo-Gyung;Hwang, Cheong-Ho;Kim, Nam-Ryul;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1334-1335
    • /
    • 2008
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in uniform and nonuniform field was performed. The experiments were carried out under AC voltages. The sphere-sphere electrode whose gap distance was 1 mm was used and the point-plane electrode whose gap distance was 3 mm was used in a test chamber. $SF_6/CF_4$ mixture contained 20% $SF_6$ and 80% $CF_4$ and the experimental gas pressure ranged from 0.1 to 0.5 MPa. The results show that addition of $SF_6/CF_4$ mixtures increase AC breakdown voltages. In uniform field the breakdown voltages of gas were linearly increased according to the pressure. However in nonuniform field the breakdown voltages of gas were increased nonlinearly.

  • PDF

The Study of Character of Electron Drift Velocity in CF4 Molecular Gas by the Boltzmann Equation (볼츠만 방정식에 의한 CF4 분자가스의 전자이동속도 특성에 관한 연구)

  • Song, Byoung-Doo;Ha, Sung-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1252-1257
    • /
    • 2004
  • This paper describes the information for quantitative simulation of weakly ionized plasma. In previous paper, we calculated the electron transport coefficients by using two-term approximation of Boltzmann equation. But there is difference between the result of the two-term approximation of the Boltzmann equation and experiments in pure CF$_4$ molecular gas and in CF$_4$+Ar gas mixture. Therefore, In this paper, we calculated the electron drift velocity (W) in pure CF$_4$ molecular gas and CF$_4$+Ar gas mixture (1 %, 5 %, 10 %) for range of E/N values from 0.17~300 Td at the temperature was 300 K and pressure was 1 Torr by multi-term approximation of the Boltzmann equation by Robson and Ness. The results of two-term and multi-term approximation of the Boltzmann equation have been compared with each other for a range of E/N.

SLI, AC Breakdown Voltage Characteristics of $SF_6/CF_4$ Mixtures Gas in Nonuniform Field (불평등전계에서 $SF_6/CF_4$ 혼합 가스의 SLI, AC 절연내력 특성)

  • Hwang, Cheong-Ho;Sung, Heo-Gyung;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.245-251
    • /
    • 2008
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field was performed. The experiments were carried out under AC voltage and standard lightning impulse(SLI) voltage. Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltages and standard lighting impulse voltage was applied in a needle-plane. The needle-plane electrode whose gap distance was 3 mm were used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.5 MPa. The breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field may be influenced by defects like needle-shaped protrusions. In case of slowly rising SLI voltage and AC voltage it is enhanced by corona-stabilization. This phenomena caused by the ion drift during streamer development and the resulting space-charge is investigated. In non-uniform field under negative SLI voltage the breakdown voltage was increase linearly but under positive SLI voltage the breakdown voltage increase non-linearly. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at AC voltage. $SF_6/CF_4$ mixture has good dielectric strength and arc-extinguishing properties than pure SF6. This paper presents experimental results on breakdown characteristics for various mixtures of $SF_6/CF_4$ at practical pressures. We could make an environment friendly gas insulation material with maintaining dielectric strength by combing $SF_6\;and\;CF_4$ which generates a lower lever of the global warming effect.

Etching Mechanism of $YMnO_3$ Thin Films in High Density $CF_4$/Ar Plasma ($CF_4$/Ar 가스 플라즈마를 이용한 $YMnO_3$ 박막의 식각 반응연구)

  • 김동표;김창일;이철인
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.12
    • /
    • pp.959-964
    • /
    • 2001
  • We investigated the etching characteristics of YMnO$_3$ thin films in high-density plasma etching system. In this study, YMnO$_3$ thin films were etched with CF$_4$/Ar gas chemistries in inductively coupled plasma(ICP). Etch rates of YMnO$_3$ increased up to 20% CF$_4$ in CF$_4$/(CF$_4$+Ar), but decreased with furthermore increasing CF$_4$ in CF$_4$/(CF$_4$+Ar). In optical emission spectroscopy (OES) analysis, F radical and Ar* ions in plasma at various gas chemistries decreased with increasing CF$_4$ content. Chemical states of YMnO$_3$ films exposed in plasma were investigated with x-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS). There is a chemical reaction between metal (Y, Mn) and F and metal-fluorides were removed effectively by Ar ion sputtering. YF$_{x}$, MnF$_{x}$ such as YF, YF$_2$, YF$_3$ and MnF$_3$ were detected using SIMS analysis. The etch slope is about 65$^{\circ}$ and cleasn surface. surface of the etched YMnO$_3$ thin films was investigated with X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS). The etch profile was also investigated by scanning electron microscopy (SEM).EM).

  • PDF

Breakdown Characteristics of $SF_6/CF_4$ Mixtures Under AC and Standard Lightning Impulse Voltages in Uniform Field (평등전계에서 AC 및 표준 뇌 임펄스 전압의 $SF_6/CF_4$ 혼합 가스 절연 파괴 특성)

  • Sung, Heo-Gyung;Park, Shin-Woo;Hwang, Chung-Ho;Kim, Nam-Ryul;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.227-228
    • /
    • 2007
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of SFJCF4 mixtures in uniform field was performed. The experiments were carried out under AC and standard lightning impulse (SLI) voltages. The sphere-sphere electrode whose gap distance was 1 mm was used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.4 MPa. The results show that addition of $SF_6$ to $CF_4$ increase AC and SLI breakdown voltages. Under AC voltages the breakdown voltages of each mixture were linearly increased according to the quantity of $SF_6$. However under SLI voltages the breakdown voltages of each mixture were similar.

  • PDF

Permeation and Permselectivity variation of $O_2$, $CF_4$ and $SF_6$ through Polymeric Hollow Fiber Membranes (고분자 분리막 재질 변화에 따른 $O_2$, $CF_4$, $SF_6$ 투과도 및 투과선택도 특성 변화에 대한 연구)

  • Lee, Hyun-Jung;Lee, Min-Woo;Lee, Hyun-Kyung;Lee, Sang-Hyup
    • Membrane Journal
    • /
    • v.20 no.3
    • /
    • pp.249-258
    • /
    • 2010
  • In this study, we tried to observe the permeation on the single $O_2$, $CF_4$ and $SF_6$ gas using a PSF (polysulfone), PC (tetra-bromo polycarbonate) and PI (polyimide) hollow fiber membranes. We also observed the permselectivity on the $O_2/SF_6$ and $CF_4/SF_6$. According to the results of single gases permeation for different pressures, PSF membrane has the highest $O_2$ permeation of 37.5 GPU and PC membrane has the highest $SF_6$ permeation of 2.7 GPU and the highest $CF_4$ permeation of 2.5 GPU at 1.1 MPa. According to the results of single gases permeation for different temperatures, PSF membrane has the highest permeation of $O_2$ at $45^{\circ}C$ and PC membrane has the highest permeation of $SF_6$ and $CF_4$ at $25^{\circ}C$. From the result of $O_2/SF_6$ and $CF_4/SF_6$ permselectivity for different pressures and temperature, the highest permeation and the lowest permselectivity were observed in the PSF and PC membrane. On the contrary, the lowest permeation and the highest permselectivity was observed in the PI membrane.