• Title/Summary/Keyword: CEA ratio

Search Result 58, Processing Time 0.024 seconds

Postoperative Serum CEA Level is a More Significant Prognostic Factor than Post/Preoperative Serum CEA Ratio in Non-small Cell Cancer Patients

  • Tomita, Masaki;Ayabe, Takanori;Chosa, Eiichi;Nakamura, Kunihide
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7809-7812
    • /
    • 2015
  • Background: In non-small cell lung cancer (NSCLC) patients with preoperative high serum carcinoembryonic antigen (CEA) level, patients with a persistently high serum CEA level after surgery have been reported to have a poor prognosis. In addition, in other cancers, the post/preoperative serum CEA ratio has been reported as a useful parameter. Materials and Methods: We enrolled 123 NSCLC patients with preoperative high CEA levels (${\geq}5ng/mL$) who underwent curative surgery between 2004 and 2011. Prognostic significance of postoperative serum CEA level and the CEA ratio was examined. Results: The 5-year survival of patients with persistently high serum CEA level after surgery was poor. On the other hand, patients with normal postoperative serum CEA levels had significant favorable prognosis. The patients with CEA ratio>1 had poor prognosis, however the number was only 7 (5.7%). The 5-year survival rates of patients with other subgroup based on the CEA ratio ($0.5{\geq}CEA$ ratio and $0.5{\leq}CEA$ $ratio{\leq}1$) was similar. Multivariate analysis revealed prognostic significance for the postoperative serum CEA level but not the CEA ratio. Conclusions: For NSCLC patients with preoperative high serum CEA level, their postoperative serum CEA levels is a more significant prognostic factor than the post/preoperative serum CEA ratio.

Enhanced CEA-specific Immune Responses by Tat-LLO Fusion Protein (Tat-LLO 융합 단백질에 의한 CEA 특이 항종양 면역 반응의 증가)

  • Yi, Soon-Aei;Sohn, Hyun-Jung;Kim, Chang-Hyun;Park, Mi-Young;Oh, Seong-Taek;Kim, Tai-Gyu
    • IMMUNE NETWORK
    • /
    • v.5 no.3
    • /
    • pp.172-178
    • /
    • 2005
  • Background: Carcinoembryonic antigen (CEA) is well-known soluble tumor marker frequently detectable in peripheral blood of carcinoma patients and considered as good target for antigen-specific immunotherapy. However, it is known that the induction of immune response to CEA is very difficult because CEA is a self-antigen expressed in fetal cells and weakly expressed in normal colorectal epithelial cells. To enhance anti-tumor immunity specific for CEA, recombinant CEA protein was modified using listeriolysin O (LLO) for endosomal lysis and trans activator of transcription (Tat) domain for transducing extracellular proteins into cytoplasm. Methods: After immunization using dendritic cells pulsed with Tat-CEA, both Tat-CEA and LLO, and both Tat-CEA and Tat-LLO, antibody titer to CEA and LLO, cytotoxic T lymphocyte activity and the frequency of IFN-${\gamma}$ producing T lymphocytes were measured. Results: Immunization using DC pulsed with both Tat-CEA and Tat-LLO protein showed the increasement of production of CEA-specific antibody in serum, cytotoxic T lymphocyte activity, the frequency of IFN-${\gamma}$ secreting T cells, compared with DC pulsed with both Tat-CEA and LLO. Furthermore the ratio of CD8+T cell to $CD4^+$ cell among CEA-specific T cells was increased in group pulsed with both Tat-CEA and Tat-LLO. Conclusion: These results suggested that DC vaccine using Tat-LLO could be used for the development of effective immunotherapy for the treatment of tumor.

Preparation and Characterization of Primer and Synthesized Chlorinated Polyolefine (CPO)-g-Carboxy Ethyl Acid (β-CEA) (Chlorinated Polyolefine (CPO)-g-β Carboxy Ethyl Acid (β-CEA) 수지의 합성 및 이를 Base Polymer로 하는 프라이머의 제조 및 물성)

  • Jeong, Booyoung;Cheon, Jungmi;Oh, Sangtaek;Kim, Taekyun;Chun, Jaehwan
    • Journal of Adhesion and Interface
    • /
    • v.12 no.2
    • /
    • pp.62-66
    • /
    • 2011
  • In this study, we synthesized a excellent adhesive chlorinated polyolefin (CPO)-g-$\beta$-carboxy ethyl acid ($\beta$-CEA) by radical polymerization. Also, we prepared low-level toxic primer for polypropylene (PP) using CPO-g-$\beta$-CEA and studied toxic and adhesion property. We identified the graft structure and properties of the prepared chlorinated polyolefin-g-$\beta$ CEA using FT-IR, DSC, UTM. Graft ratio were optimum value at 5 wt% $\beta$-CEA contents in CPO-g-$\beta$ CEA. And the primer for PP was prepared with CPO-g-$\beta$ CEA and adhesive builder PX-95 content. Finally, optimum peel strength obtained when PX-95 contents was 3 wt%.

Simulation of Pre-burner Performance in Liquid-fueled Rocket Engine for Satellite Launch Vehicle (위성 발사체 액체 로켓 엔진의 Pre-burner 성능 모사)

  • Shin, Ji-Chul;Jung, Tae-Kyu;Lee, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.12
    • /
    • pp.1180-1185
    • /
    • 2008
  • In-house code which simulates the performance of pre-burner in staged-combustion liquid-fueled rocket engine was developed and demonstrated. Chemical reaction of pre-burner was modeled based on analytic algorithm of CEA (Chemical Equilibrium with Applications) and gas dynamics model was incorporated with it. Comparison results between in-house code and CEA have shown small relative errors except at very high or very low O/F ratio. Also the performance curve obtained by in-house code revealed that the calculated values follow the overall trend of real engine (RD-8) performance quite well and at steady-state operation, the deviation became very small.

Usefulness estimating of Time of flight(TOF) during Carotid angio inspection including Aortic arch (Aortic arch를 포함한 Carotid angio 검사 시 Time of flight(TOF)의 유용성 평가)

  • Yoo, Yeong-Jun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The Carotid Angio inspection including Aortic arch applied to wide area is conducted as the Contrast Enhance MR Angiography(CEA) which is using a contrast medium. However it is a burden not only for someone such as infants, pregnant women and patients suffering from kidney failure but continuous use of contrast medium also can be a burden for patients who has been taken follow up inspection since diagnose lesion already. The purpose of this study is to estimate a usefulness of the Time of Flight (TOF) by comparing with CEA. Materials and methods : 10 patients with an average age of 58 (from 45 to 75) who had MRA inspection in our hospital were studied using 3.0 Tesla Aachieva (Philips, Netherland) MRI system and Sense Neuro-Vascular 16 Channels Coil. The same patient was inspected both TOF and CEA simultaneously. The TOF inspection included from Aortic arch to Willis Circle by connecting 3 TOF stacks and so did CEA inspection. The quantitative analysis was conducted through signal to noise ratio(SNR) and contrast to noise ratio(CNR) with soft tissue by setting up an area of interest on CCA bifurcatoin, ICA, ECA, MCA and VA concerning obtained image. In case of qualitative analysis, 3 radiological technologists and 1 radiologist evaluated 4 items (1: Visibility of the blood vessel, 2: Image distortion measure, 3: Overlapping measure with vein, 4: Peripheral blood vessel description measure) into five points scale (1: Very bad, 2: Bad, 3: Normal 4: Good, 5: Very good). Results : Results for the quantitative analysis was obtained by calculating the average of 5 ROIs in case of SNR and CNR separately. Results of SNR, TOF were generally measured higher than CEA (In case of TOF were 166.1, 205.2, 154.39, 172.23, 161.95, and CEA were 92.05, 95.43, 84.76, 73.69, 88.3). But according to the result of CNR, both TOF and CEA were measured similarly as 67.62, 106.71, 55.9, 73.74, 63.46 for TOF and 67.82, 71.19, 60.52, 49.45, 64.07 for CEA. Throughout every results of each ROI, SNR showed statistically meaningful consequence (0.050.05). In case of qualitative analysis the average of each evaluated item was 4.2points and 4.28points in the item1, 2.93points and 4.55points in the item2, 4.6points and 3.13points in the item3, 2.88points and 4.6points in the item4. According to the results TOF was measured higher in the item3 while in the item2 and item4 CEA was higher and in case of the item1, both CEA and TOF were similar. To sum up statistically meaningful results (p<0.05) were shown in the item2, item3 and item4 but not in the item1 (p>0.05). Conclusions : Both TOF and CEA are complementary because each inspection has pros and cons, but when inspect wide area including Aortic arch normally CEA is conducted. But TOF inspection also can be considered as alternative in terms of patients who has difficulty in the contrast medium such as infants, pregnant women and patients suffering from kidney failure and patients during follow up.

  • PDF

Damage detection of shear buildings using frequency-change-ratio and model updating algorithm

  • Liang, Yabin;Feng, Qian;Li, Heng;Jiang, Jian
    • Smart Structures and Systems
    • /
    • v.23 no.2
    • /
    • pp.107-122
    • /
    • 2019
  • As one of the most important parameters in structural health monitoring, structural frequency has many advantages, such as convenient to be measured, high precision, and insensitive to noise. In addition, frequency-change-ratio based method had been validated to have the ability to identify the damage occurrence and location. However, building a precise enough finite elemental model (FEM) for the test structure is still a huge challenge for this frequency-change-ratio based damage detection technique. In order to overcome this disadvantage and extend the application for frequencies in structural health monitoring area, a novel method was developed in this paper by combining the cross-model cross-mode (CMCM) model updating algorithm with the frequency-change-ratio based method. At first, assuming the physical parameters, including the element mass and stiffness, of the test structure had been known with a certain value, then an initial to-be-updated model with these assumed parameters was constructed according to the typical mass and stiffness distribution characteristic of shear buildings. After that, this to-be-updated model was updated using CMCM algorithm by combining with the measured frequencies of the actual structure when no damage was introduced. Thus, this updated model was regarded as a representation of the FEM model of actual structure, because their modal information were almost the same. Finally, based on this updated model, the frequency-change-ratio based method can be further proceed to realize the damage detection and localization. In order to verify the effectiveness of the developed method, a four-level shear building was numerically simulated and two actual shear structures, including a three-level shear model and an eight-story frame, were experimentally test in laboratory, and all the test results demonstrate that the developed method can identify the structural damage occurrence and location effectively, even only very limited modal frequencies of the test structure were provided.

Correlation between Serum Carcinoembryonic Antigen Level and Histologic Subtype in Resected Lung Adenocarcinoma

  • Tomita, Masaki;Ayabe, Takanori;Nakamura, Eiichi Chosa Kunihide
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3857-3860
    • /
    • 2015
  • Background: Recent studies revealed a relationship between ground-glass opacity (GGO) ratio on computed tomography (CT) and serum carcinoembryonic antigen (CEA) level in lung adenocarcinoma. Since an association between lepidic histologic pattern and GGO is well accepted, we investigated the link between histologic subtype and serum CEA level in resected lung adenocarcinoma. Materials and Methods: One hundred and eighty-one consecutive patients with resected lung adenocarcinoma were studied retrospectively. The histologic subtype was subdivided into 2 groups: lepidic dominant histologic subtype, including adenocarcinoma in situ, minimally invasive adenocarcinoma and lepidic predominant invasive adenocarcinoma versus other subtypes. Results: The 5-year survival of patients with s high serum CEA level was significantly more unfavorable than that with normal levels. Similarly, there was also a relationship between the patient survival and histologic subtype, with favorable survival found in patients with the lepidic dominant histologic subtype. There was a significant relationship between serum CEA level and lepidic dominant histologic subtype overall and in p-stage I patients. Conclusions: Lung adenocarcinomas with non-lepidic dominant histologic subtype are associated with high serum CEA levels.

$^{99m}Tc-Labeling$ of Monoclonal Antibody to Carcinoembryonic Antigen and Biodistribution (항 암태아성항원에 대한 단세포군항체의 $^{99m}Tc$ 표지법개발 및 생체분포)

  • Moon, Dae-Hyuk;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Chung, Hong-Keun;Park, Jae-Gahb
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.380-391
    • /
    • 1992
  • This study was designed to evaluate a direct method of $^{99m}Tc$ labeling using $\beta-mercaptoethanol$ as a reducing agent, and to investigate whether $^{99m}Tc$ labeled specific monoclonal antibody against carcinoembryonic antigen (CEA-92) can be used for the scintigraphic localization of human colon cancer xenograft. Purified CEA-92 IgG was fragmented into F $(ab')_2$ and then labeled with $^{99m}Tc$ by transchelation method using glucarate as a chelator. Labeling efficiency, immunological reactivity and in vitro stability of $^{99m}Tc$ CEA-92 F $(ab')_2$ were measured and then injected intravenously into nude mice bearing human colon cancer (SNU-C4). Scintigrams were obtained at 24 hour after injection. Then nude mice were sacrificed and the radioactivity was measured Labeling efficiency of injected $^{99m}Tc$ CEA-92 F $(ab')_2$, immunoreative fraction and in vitro stability at 24 hour of injected $^{99m}Tc$ CEA-92 F $(ab')_2$ was 45.2%, 32.8% and 57.4%, respectively. At 24 hour after injection, % ID/g in kidney (46.77) showed high uptake, but %ID/g in tumor (1.65) was significantly higher than spleen (0.69), muscle (0.16), intestine (0.45), stomach (0.75), heart (0.48) and blood (0.45). There was no significant difference between tumor and liver (1.81). Tumor contrast as quantitated by tumor to blood ratio of $^{99m}Tc$ CEA-92 F $(ab')_2$ was increased significantly (p<0.005) until 24 hours (3.70), and there was no statistical differece from tumor to blood ratio of I-131 CEA-92 F $(ab')_2$. The scintigram demonstrated localization of radioactivity over transplanted tumor, but significant background radioactivity was also noted over kidney and abdomen. It is concluded that CEA-92 F $(ab')_2$ can be labeled with $^{99m}Tc$ by a direct transchelation method using $\beta-mercaptoethanol$ as a reducing agent and $^{99m}Tc$ labeled CEA-92 F $(ab')_2$ can be used for the scintigraphic localization of human colon cancer xenograft in nude mice model.

  • PDF

An Assessment of the Usefulness of Time of Flight in Magnetic Resonance Angiography Covering the Aortic Arch

  • Yoo, Yeong-Jun;Choi, Sung-Hyun;Dong, Kyung-Rae;Ji, Yun-Sang;Choi, Ji-Won;Ryu, Jae-Kwang
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.325-332
    • /
    • 2018
  • Carotid angiography covering the aortic arch includes contrast-enhanced magnetic resonance angiography (CEA), which is applied to a large region and usually employs contrast media. However, the use of contrast media can be dangerous in infants, pregnant women, and patients with chronic renal failure (CRF). Follow-up patients informed of a lesion may also want to avoid constant exposure to contrast media. We aimed to apply time-of-flight (TOF) angiography to a large region and compare its usefulness with that of CEA. Ten patients (mean age, 58 years; range, 45~75 years) who visited our hospital for magnetic resonance angiography (MRA) participated in this study. A 3.0 Tesla Achieva magnetic resonance imaging (MRI) system (Philips, Netherland) and the SENSE NeuroVascular 16-channel coil were employed for both methods. Both methods were applied simultaneously to the same patient. Three TOF stacks were connected to cover the aortic arch through the circle of Willis, and CEA was applied in the same manner. For the quantitative assessment, the acquired images were used to set the regions of interest (ROIs) in the common carotid artery (CCA) bifurcation, internal carotid artery, external carotid artery, middle cerebral artery, and vertebral artery, and to obtain the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) for the soft tissues. Three radiologists and one radiological resident performed the qualitative assessment on a 5-point scale - 1 point, "very bad"; 2 points, "bad"; 3 points, "average"; 4 points, "good"; and 5 points, "very good" - with regard to 4 items: (1) sharpness, (2) distortion, (3) vein contamination, and (4) expression of peripheral vessels. For the quantitative assessment, we estimated the mean SNR and CNR in each of the 5 ROIs. In general, the mean SNR was higher in TOF angiography (166.1, 205.2, 154.39, 172.23, and 161.95) than in CEA(92.05, 95.43, 84.76, 73.69, and 88.3). Both methods had a similar mean CNR: 67.62, 106.71, 55.9, 73.74, and 63.46 for TOF angiography, and 67.82, 71.19, 60.52, 49.45, and 64.07 for CEA. In all ROIs, the mean SNR was statistically significant (p<0.05), whereas the mean CNR was insignificant (p>0.05). The mean values of TOF angiography and CEA for each item in the qualitative assessment were 4.2 and 4.28, respectively for item 1; 2.93 and 4.55, respectively, for item 2; 4.6 and 3.13, respectively, for item 3; and 2.88 and 4.65, respectively, for item 4. Therefore, TOF angiography had a higher mean for item 3, and CEA had a higher mean for items 2 and 4; there was no significant difference between the two methods for item 1. The results for item 1 were statistically insignificant (p>0.05), whereas the results for items 2~4 were statistically significant (p<0.05). Both methods have advantages and disadvantages and they complement each other. However, CEA is usually applied to a large region covering the aortic arch. Time-of-flight angiography may be useful for people such as infants, pregnant women, CRF patients, and followup patients for whom the use of contrast media can be dangerous or unnecessary, depending on the circumstance.

Applicative Value of Serum CA19-9, CEA, CA125 and CA242 in Diagnosis and Prognosis for Patients with Pancreatic Cancer Treated by Concurrent Chemoradiotherapy

  • Gu, Yu-Lei;Lan, Chao;Pei, Hui;Yang, Shuang-Ning;Liu, Yan-Fen;Xiao, Li-Li
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6569-6573
    • /
    • 2015
  • Objective: To evaluate the application value of serum CA19-9, CEA, CA125 and CA242 in diagnosis and prognosis of pancreatic cancer cases treated with concurrent chemotherapy. Materials and Methods: 52 patients with pancreatic cancer, 40 with benign pancreatic diseases and 40 healthy people were selected. The electrochemiluminescence immunoassay method was used for detecting levels of CA19-9, CEA and CA125, and a CanAg CA242 enzyme linked immunoassay kit for assessing the level of CA242. The Kaplan-Meier method was used for analyzing the prognostic factors of patients with pancreatic cancer. The Cox proportional hazard model was applied for analyzing the hazard ratio (HR) and 95% confidential interval (CI) for survival time of patients with pancreatic cancer. Results: The levels of serum CA19-9, CEA, CA125 and CA242 in patients with pancreatic cancer were significantly higher than those in patients with benign pancreatic diseases and healthy people (P<0.001). The sensitivity of CA19-9 was the highest among these, followed by CA242, CA125 and CEA. The specificity of CA242 is the highest, followed by CA125, CEA and CA19-9. The sensitivity and specificity of joint detection of serum CA19-9, CEA, CA125and CA242 were 90.4% and 93.8%, obviously higher than single detection of those markers in diagnosis of pancreatic cancer. The median survival time of 52 patients with pancreatic cancer was 10 months (95% CI7.389~12.611).. Patients with the increasing level of serum CA19-9, CEA, CA125, CA242 had shorter survival times (P=0.047. 0.043, 0.0041, 0.029). COX regression analysis showed that CA19-9 was an independent prognostic factor for patients with pancreatic cancer (P=0.001, 95%CI 2.591~38.243). Conclusions: The detection of serum tumor markers (CA19.9, CEA, CA125 and CA242) is conducive to the early diagnosis of pancreatic cancer and joint detection of tumor markers helps improve the diagnostic efficiency. Moreover, CA19-9 is an independent prognostic factor for patients with pancreatic cancer.