• 제목/요약/키워드: CAD/CAM materials

검색결과 295건 처리시간 0.025초

Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments

  • Safari, Sina;Ghavam, Fereshteh Hosseini;Amini, Parviz;Yaghmaei, Kaveh
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권1호
    • /
    • pp.1-7
    • /
    • 2018
  • PURPOSE. The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. MATERIALS AND METHODS. Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (${\alpha}=.05$). RESULTS. The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly (P=.006). The difference in retention between the cemented and recemented copings was not statistically significant (P=.40). CONCLUSION. Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement.

Implant에 사용되는 CAD/CAM 전용 zirconia abutment의 표면적과 디자인에 따른 유지력 차이 (Differences in retention of the reduction direction depending on dimensions and design CAD/CAM zirconia abutment for implant)

  • 남택모;김한곤;김병식;임시덕
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.317-325
    • /
    • 2010
  • Purpose: The aim of this study is to make some basic materials to find retention force difference based on the total height of CAD/CAM zirconia abutment used for implant, retention force difference based on how to regulate the height of the abutment, retention force difference based on the size and retention force difference based on the design group. Methods: The retention force was measured by being pulled at the speed of 1mm/min after being combined with zirconia block and abutment using Temp-BOND of Kerr. The experiment was done at the research lab of OSTEM in Busan by useing UNIVERSAL TESTING MACHINE on March 3rd, 2010. Results: After analysing the total height and the retention force, p-value had minor difference by 0.01 statistically. Namely, 3mm, 4mm, 5mm had the retention force difference and we could see retention force difference on 3mm and 5mm at the post test. After analyzing how to regulate the height and retention force, p-value had minor difference by 0.000 statistically. Namely, 1mm and 2mm had the retention difference and we could see that 1mm and 2mm with the total height had retention difference. After analyzing the retention force based on the size, p-value had minor retention force difference by 0.000 statistically. Namely, 7 different size had retention force difference and we could see the size 21.9mm, 32.9mm, 32.9mm, 38.4mm, 48.9mm and 54.9mm had retention force difference. Conclusion: Namely 9 different design group had retention difference and we could see that 9 design group with 5.6.7.8 design group and 9 design group with 1.2.3.4. design group had retention force.

Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards

  • Jeon, Jin-Hun;Hwang, Seong-Sig;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.335-339
    • /
    • 2018
  • PURPOSE. The purpose of the present study was to compare scanning trueness and precision between an abutment impression and a stone model according to dental computer-aided design/computer-aided manufacturing (CAD/CAM) evaluation standards. MATERIALS AND METHODS. To evaluate trueness, the abutment impression and stone model were scanned to obtain the first 3-dimensional (3-D) stereolithography (STL) file. Next, the abutment impression or stone model was removed from the scanner and re-fixed on the table; scanning was then repeated so that 11 files were obtained for each scan type. To evaluate precision, the abutment impression or stone model was scanned to obtain the first 3-D STL file. Without moving it, scanning was performed 10 more times, so that 11 files were obtained for each scan type. By superimposing the first scanned STL file onto the other STL files one by one, 10 color-difference maps and reports were obtained; i.e., 10 experimental scans per type. The independent t-test was used to compare root mean square (RMS) data between the groups (${\alpha}=.05$). RESULTS. The $RMS{\pm}SD$ values of scanning trueness of the abutment impression and stone model were $22.4{\pm}4.4$ and $17.4{\pm}3.5{\mu}m$, respectively (P<.012). The $RMS{\pm}SD$ values of scanning precision of the abutment impression and stone model were $16.4{\pm}2.9$ and $14.6{\pm}1.6{\mu}m$, respectively (P=.108). CONCLUSION. There was a significant difference in scanning trueness between the abutment impression and stone model, as evaluated according to dental CAD/CAM standards. However, all scans showed high trueness and precision.

A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments

  • Park, Ji-Man;Lee, Jai-Bong;Heo, Seong-Joo;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.46-52
    • /
    • 2014
  • PURPOSE. The aim of this study was to evaluate the interface accuracy of computer-assisted designed and manufactured (CAD/CAM) titanium abutments and implant fixture compared to gold-cast UCLA abutments. MATERIALS AND METHODS. An external connection implant system (Mark III, n=10) and an internal connection implant system (Replace Select, n=10) were used, 5 of each group were connected to milled titanium abutment and the rest were connected to the gold-cast UCLA abutments. The implant fixture and abutment were tightened to torque of 35 Ncm using a digital torque gauge, and initial detorque values were measured 10 minutes after tightening. To mimic the mastication, a cyclic loading was applied at 14 Hz for one million cycles, with the stress amplitude range being within 0 N to 100 N. After the cyclic loading, detorque values were measured again. The fixture-abutment gaps were measured under a microscope and recorded with an accuracy of ${\pm}0.1{\mu}m$ at 50 points. RESULTS. Initial detorque values of milled abutment were significantly higher than those of cast abutment (P<.05). Detorque values after one million dynamic cyclic loadings were not significantly different (P>.05). After cyclic loading, detorque values of cast abutment increased, but those of milled abutment decreased (P<.05). There was no significant difference of gap dimension between the milled abutment group and the cast abutment group after cyclic loading. CONCLUSION. In conclusion, CAD/CAM milled titanium abutment can be fabricated with sufficient accuracy to permit screw joint stability between abutment and fixture comparable to that of the traditional gold cast UCLA abutment.

Shear bond strength of a new self-adhering flowable composite resin for lithium disilicate-reinforced CAD/CAM ceramic material

  • Erdemir, Ugur;Sancakli, Hande Sar;Sancakli, Erkan;Eren, Meltem Mert;Ozel, Sevda;Yucel, Taner;Yildiz, Esra
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.434-443
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate and compare the effects of different surface pretreatment techniques on the surface roughness and shear bond strength of a new self-adhering flowable composite resin for use with lithium disilicate-reinforced CAD/CAM ceramic material. MATERIALS AND METHODS. A total of one hundred thirty lithium disilicate CAD/CAM ceramic plates with dimensions of $6mm{\times}4mm$ and 3 mm thick were prepared. Specimens were then assigned into five groups (n=26) as follows: untreated control, coating with $30{\mu}m$ silica oxide particles ($Cojet^{TM}$ Sand), 9.6% hydrofluoric acid etching, Er:YAG laser irradiation, and grinding with a high-speed fine diamond bur. A self-adhering flowable composite resin (Vertise Flow) was applied onto the pre-treated ceramic plates using the Ultradent shear bond Teflon mold system. Surface roughness was measured by atomic force microscopy. Shear bond strength test were performed using a universal testing machine at a crosshead speed of 1 mm/min. Surface roughness data were analyzed by one-way ANOVA and the Tukey HSD tests. Shear bond strength test values were analyzed by Kruskal-Wallis and Mann-Whitney U tests at ${\alpha}=.05$. RESULTS. Hydrofluoric acid etching and grinding with high-speed fine diamond bur produced significantly higher surface roughness than the other pretreatment groups (P<.05). Hydrofluoric acid etching and silica coating yielded the highest shear bond strength values (P<.001). CONCLUSION. Self-adhering flowable composite resin used as repair composite resin exhibited very low bond strength irrespective of the surface pretreatments used.

Pull-off resistance of a screwless implant-abutment connection and surface evaluation after cyclic loading

  • Alevizakos, Vasilios;Mosch, Richard;Mitov, Gergo;Othman, Ahmed;See, Constantin von
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.152-159
    • /
    • 2021
  • Purpose. The aim of this study was to investigate to what extent cyclic load affects the screwless implant-abutment connection for Morse taper dental implants. Materials and Methods. 16 implants (SICvantage max) and 16 abutments (Swiss Cross) were used. The screwless implant-abutment connection was subjected to 10,000 cycles of axial loading with a maximum force of 120 N. For the pull-off testing, before and after the same cyclic loading, the required force for disconnecting the remaining 6 implant-abutment connections was measured. The surface of 10 abutments was examined using a scanning electron microscope 120× before and after loading. Results. The pull-off test showed a significant decrease in the vertical force required to pull the abutment from the implant with mean 229.39 N ± 18.23 before loading, and 204.30 N ± 13.51 after loading (P<.01). Apart from the appearance of polished surface areas and slight signs of wear, no visible damages were found on the abutments. Conclusion. The deformation on the polished abutment surface might represent the result of micro movements within the implant-abutment connection during loading. Although there was a decrease of the pull-off force values after cyclic loading, this might not have a notable effect on the clinical performance.

무북직기용 Beating Cam 기구의 최적설계에 관한 연구 (A study on Optimum Design of Beating Cam Meachanism for Shuttleless Loom)

  • 김종수;신중호
    • 연구논문집
    • /
    • 통권22호
    • /
    • pp.75-83
    • /
    • 1992
  • The beating motion of a high speed shuttleless loom is driven by cams. Two cams become one system and their shaft laid across each other. Moreover, the shape of the cams is very complex and requires high precision for successful weft insertion and good interlacing with warp yarn. The iterative contact method is developed for use in design and analysis of the driving mechanism of a disk type cam with oscillating roller follower. The optimum design is performed by utilizing a CAD program, DISKCAM. The 8th order polynomial is selected to interpolate the desired shape trajectory of the cam, the optimal shape of the cams is defined based on the demension of the follower. The kinematic motion of the beating cam mechanism is investigated. The phase angle is determined to achive harmonious cam motions

  • PDF

CAD/CAM 3-unit bridges의 변연 적합도에 관한 연구 (A study on the marginal fit of CAD/CAM 3-unit bridges)

  • 이기홍;여인성;김성훈;한중석;이재봉;양재호
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.101-105
    • /
    • 2011
  • 연구 목적: 본 연구에서는CAD/CAM (computer-aided design / computer-aided manufacturing) 시스템으로 제작된LAVA (3M ESPE, Seefeld, Germany) 3-unit bridge와 통상적인 방법으로 제작된 PFG 3-unit bridge의 변연 적합도를 비교 분석해 보고자 한다. 연구 재료 및 방법: 레진치를 전부 도재관을 위한 삭제를 시행하고 인상 채득하여 레진 모형 (Exakto-form model resin, Bredent, Senden, Germany)을군당10개씩 제작하였다. 레진 모형의 인상을 채득하여 석고 모형을 제작하고 PFG, LAVA 3-unit bridge를 10개씩 제작하였다. 제작된 bridge를 레진 모형에 접착하고 실체 현미경(Stereoscopic microscope, Nikon DS-Fi 1, Nikon, Japan)을 사용하여 각 치아당 4점에서 변연 적합도를 측정하였다 (${\times}75$). 측정된 결과는 independent t-test로 통계 분석하였다 (${\alpha}$ = 0.05). 결과: 각 군에서 변연 적합도의 평균과 표준편차는 PFG bridge 중절치에서는 $97.1{\pm}18.7\;{\mu}m$, 견치에서는 $76.6{\pm}21.8\;{\mu}m$, LAVA bridge 중절치에서는 $90.4{\pm}26.7\;{\mu}m$, 견치에서는$110.2{\pm}30.2\;{\mu}m$ 이었다. PFG 3-unit bridge와LAVA 3-unit bridge에서 중절치에서는 통계적 유의성이 없었고, 견치에서는LAVA의 변연 간격이 큰 것으로 나타났다 (P<.05). 결론: PFG 3-unit bridge와 LAVA 3-unit bridge 두 군 모두 임상적으로 받아들여질 만한 변연 적합도를 보였다.

전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교 (Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns)

  • 고인석;김정미;조혜원
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.226-233
    • /
    • 2016
  • 목적: 본 연구는 수복물의 적합도를 계측하는 두 가지 측정방법을 평가하기 위해 CAD-CAM (computer aided design-computer aided manufacturing)과 열가압 소성법으로 전부 도재관을 제작하고 micro CT와 cross-section technique으로 전부 도재관의 적합도를 비교하고자 하였다. 재료 및 방법: 하악 제 1대구치 레진 치아를 전부 도재관을 위한 지대치를 형성하고 PMMA (polymethylmethacrylate) 레진 블록을 가공하여 10개의 시편을 복제하였다. 복제한 레진 다이의 인상을 채득하고 모형을 제작하여 5개는 열가압 소성법으로 IPS e.max Press (Ivoclar Vivadent, Schaan, Liechtenstein) 도재관을 제작하였다. 다른 5개의 시편은 CAD-CAM 가공법(Ceramil motion 2, Amann Girrbach, Koblach, Austria)을 이용하여 IPS e.max CAD 도재관을 제작하였다. 각 레진 다이에 전부 도재관을 인산아연 시멘트(Fleck's zinc cement, Keystone industries, Gibbstown, NJ, USA)로 손가락 압력에 의해 합착하였다. 변연 및 내면 적합도를 측정하기 위해서 합착된 시편 10개를 먼저 micro CT로 촬영하여 협-설 시상면의 영상정보를 획득하였다. 그 후 절단 시편을 만들어 주사전자현미경으로 micro CT와 동일한 지점의 간극을 측정하였다. SPSS 22.0 프로그램을 이용하여 각 측정 지점에서 제작 방식별, 측정 방식별로 Mann-Whitney 검정 방법을 통해 유의차 검증을 시행하였다. 결과: Micro CT와 주사전자현미경으로 측정한 변연 및 내면 적합도는 유사하였으며, 통계적으로 유의한 차이를 보이지 않았다. 두 가지 제작법의 도재관은 변연 및 내면 적합도에 유의한 차이가 없었다. 결론: CAD-CAM과 열가압소성으로 제작한 전부 도재관은 적합도에 차이를 보이고 있지 않으며, Micro CT와 주사전자현미경을 이용한 측정 방식 모두 임상적으로 이용 가능할 것으로 사료된다.

The effect of light sources and CAD/CAM monolithic blocks on degree of conversion of cement

  • Cetindemir, Aydan Boztuna;Sermet, Bulent;Ongul, Deger
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.291-299
    • /
    • 2018
  • PURPOSE. To assess the degree of conversion (DC) and light irradiance delivered to light-cured and dual-cured cements by application of different light sources through various types of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) materials. MATERIALS AND METHODS. RelyX Ultimate Clicker light-cured and dual-cured resin cement specimens with 1.5-mm thicknesses (n=300, 10/group), were placed under four types of crystalline core structure (Vita Enamic, Vita Suprinity, GC Ceresmart, Degudent Prettau Anterior). The specimens were irradiated for 40 seconds with an LED Soft-Start or pulse-delay unit or 20 seconds with a QTH unit. DC ratios were determined by using Fourier transform infrared spectroscopy (FTIR) after curing the specimen at 1 day and 1 month. The data were analyzed using the Mann-Whitney U test (for paired comparison) and the Kruskal-Wallis H test (for multiple comparison), with a significance level of P<.05. RESULTS. DC values were the highest for RelyX Ultimate Clicker light-cure specimens polymerized with the LED Soft-Start unit. The combination of the Vita Suprinity disc and RelyX Ultimate Clicker dual-cure resin cement yielded significantly higher values at both timepoints with all light units (all, P<.05). CONCLUSION. Within the limitations of this study, we conclude that the DC of RelyX Ultimate Clicker dual-cure resin cement was improved significantly by the use of Vita Suprinity and the LED Soft-Start light unit. We strongly recommend the combined use of an LED light unit and dual-cure luting cement for monolithic ceramic restorations.