• 제목/요약/키워드: C-ion irradiation

검색결과 123건 처리시간 0.028초

Development of a Wide Dose-Rate Range Electron Beam Irradiation System for Pre-Clinical Studies and Multi-Purpose Applications Using a Research Linear Accelerator

  • Jang, Kyoung Won;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Jung Kee;Moon, Young Min;Kim, Jin Young;Jeong, Dong Hyeok
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.9-19
    • /
    • 2020
  • Purpose: This study aims to develop a multi-purpose electron beam irradiation device for preclinical research and material testing using the research electron linear accelerator installed at the Dongnam Institute of Radiological and Medical Sciences. Methods: The fabricated irradiation device comprises a dual scattering foil and collimator. The correct scattering foil thickness, in terms of the energy loss and beam profile uniformity, was determined using Monte Carlo calculations. The ion-chamber and radiochromic films were used to determine the reference dose-rate (Gy/s) and beam profiles as functions of the source to surface distance (SSD) and pulse frequency. Results: The dose-rates for the electron beams were evaluated for the range from 59.16 Gy/s to 5.22 cGy/s at SSDs of 40-120 cm, by controlling the pulse frequency. Furthermore, uniform dose distributions in the electron fields were achieved up to approximately 10 cm in diameter. An empirical formula for the systematic dose-rate calculation for the irradiation system was established using the measured data. Conclusions: A wide dose-rate range electron beam irradiation device was successfully developed in this study. The pre-clinical studies relating to FLASH radiotherapy to the conventional level were made available. Additionally, material studies were made available using a quantified irradiation system. Future studies are required to improve the energy, dose-rate, and field uniformity of the irradiation system.

Effect of Hydrogen Radicals for Ion Implanted CVD Diamond Using Remote Hydrogen Plasma Treatment(RHPT)

  • Won, Jaihyung;Hatta, Akimitsu;Yagi, Hiromasa;Wang, Chunlei;Jiang, Nan;Jeon, Hyeongmin;Deguehi, Masahiro;Kitabatake, Makoto;Ito, Toshimichi;Sasaki, Takatomo;Hiraki, Akio
    • The Korean Journal of Ceramics
    • /
    • 제4권1호
    • /
    • pp.15-19
    • /
    • 1998
  • Defects formation of Chemical Vapor Deposition (CVD) diamond on $^4He^{2+}$ irradiation and after remote hydrogen plasma treatment(RHPT) were investigated by cathodoluminescence(CL). As calculated in the TRIM simulation, the light elements of $^4He^{2-}$ can be penetrated into the diamond bulk structure at 3~4 $\mu\textrm{m}$ depth. The effects of the implantation region were observed when 5 keV~20 keV electron energy (insight 0.3~4.0$\mu\textrm{m}$) of CL measurement was irradiated to diamond at temperature 80 K. After the RHPT, rehybridization of irradiation damaged diamond was studied. The intensity of 5RL center(intrinsic defect of C) was diminished. The 2.16 eV center (N-V center) occurring usually by annealing could not be seen after RHPT. The diamond was rehybridized by hydrogen radicals without etching and thermal degradation by the RHPT.

  • PDF

Functionalization of polyethylene by graft copolymerization for separation processes

  • Kaur, Inderjeet;Gupta, Nitika;Kumari, Vandna
    • Advances in materials Research
    • /
    • 제2권1호
    • /
    • pp.15-36
    • /
    • 2013
  • Incorporation of polar functional moieties into polyethylene (PE) film has been achieved by graft copolymerization of polar monomers such as methacrylic acid (MAAc) and acrylamide (AAm) on to PE film, preirradiated with ${\gamma}$-rays from $^{60}Co$ source, using benzoyl peroxide (BPO) as initiator in aqueous medium. Percentage of grafting of MAAc and AAm was determined as a function of irradiation dose, monomer and initiator concentration, temperature, reaction time and amount of water. Maximum percentage of grafting of MAAc (1453%) and AAm (21.28%) was obtained at [MAAc] = $235.3{\times}10^{-2}$ mol/L, [AAm] = $23.4{\times}10^{-2}$ mol/L, [BPO] = $5.5{\times}10^{-2}$ mol/L and $16.5{\times}10^{-2}$ mol/L at $80^{\circ}C$, $90^{\circ}C$ in 180 min and 90 min respectively. The grafted PE films were characterized by FTIR, Thermogravimetric analysis (TGA) Scanning Electron Micrography (SEM) and X-ray diffraction methods. Some selective properties of grafted films such as swelling behavior, ion and metal uptake have been carried out. The biodegradation studies of the grafted PE films have also been investigated. The grafted films developed superior swelling behavior with maximum swelling (480%) in water as compared to pristine PE (13.55%), better thermal stability and ion and metal uptake studies showed promising results that can be effectively used for desalination of brackish water and separation of metals from the industrial effluents.

IBS법에 의한 BSCCO 박막의 에피택셜 성장 (Epitaxial Growth of BSCCO Films by IBS Method)

  • 양승호;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2002년도 춘계종합학술대회
    • /
    • pp.627-630
    • /
    • 2002
  • Bi$_2$Sr$_2$CuOx(Bi-2201) thin films were fabricated by atomic layer-by-layer deposition using an ion bean sputtering method. 10 wt% and 90 wt% ozone mired with oxygen were used with ultraviolet light irradiation to assist oxidation. XRD and RHEED investigations revealed that a buffer layer is formed at the early stage of deposition (less than 10 unit cell), and then c-axis oriented Bi-2201 grows on top of it.

  • PDF

결명자 추출액에 의한 단백질계 섬유의 염색성 (Dyeing properties of Protein Fabrics by Cassia tara Extracts)

  • 문명희
    • 복식
    • /
    • 제49권
    • /
    • pp.73-84
    • /
    • 1999
  • The purpose of this study was to investigate dyeing properties of silk and wool fabric by Cassia tora extracts according to the conditions such as extraction(temperature time) dyeing(temperature time) condition kinds of mordants temperature of mordanting. The color fastness of laundering irradiation were examined. The results were as follows: The wavelength of maximum absorpthion by extracts appeared at 201, 277, 382nm in UV-Vis spectrum. Absorbance of extracts were increased with temperature and time. The extraction efficiency of Cassia tora was determined as $95^\circ{C}$ of extraction temperature 120 minutes of extraction time. Silk fabric had highest K/S value when dyeing for 90min at $40^\circ{C}$. Wool fabric had highest K/S value when dyeing for 60min at $80^\circ{C}$. Surface color of silk and wool fabric dyed with Cassia tora extracts was 3,9Y and 0.4Y but it was changed from 9.3YR to 7,4Y and from 9.4YR to 5Y by mordants. The fabrics of mordanted by metal ion dyed the depth of color. Laundering and irradiation fastness of mordanted fabrics were improved as compared with nonmordanted fabrics.

  • PDF

저온 공정의 Si을 이용한 PI 배향 막의 전기광학 특성 향상에 대한 연구 (Si Induced Polymer Based Alignment Layer for Liquid Crystal Orientations with High Electro-Optic Properties at Low Temperature)

  • 김대현
    • 한국전기전자재료학회논문지
    • /
    • 제26권9호
    • /
    • pp.677-681
    • /
    • 2013
  • Apart from the deposition of alignment layer, alignment process needs to be involved for alignment of liquid crystal (LC) molecules. To simplify manufacturing process, several method were used such as rubbing, ion-beam irradiation, UV irradiation, and lithography. But, eventually it needs another treatment for LC alignment. Here, we suggested Si induced polyimide (PI) alignment layer at low temperature. Using this method, we are able to eliminate the alignment process and found that the alignment and electro-optic performance are much better than that of the rubbed PI LC cells. Compared to the rubbed PI cells, the response time was decreased by 70% and C-V characteristics have hysteresis-free.

Surface Modification of Polypropylene Membrane by ${\gamma}$ Irradiation Methods and their Solutes Permeation Behaviors

  • Shim, J. K.;Lee, S. H.;Kwon, O. H.;Lee, Y. M.;Nho, Y. C.
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 춘계 총회 및 학술발표회
    • /
    • pp.99-101
    • /
    • 1998
  • 1. Introduction : The conventional grafting polymerization technique requires chemically reactive groups on the surface as well as on the polymer chains. For this reason, a series of prefunctionalization steps are necessary for covalent grafting. The surface prefunctionalizational technique for grafting can be used to ionization radiation, UV, plasma, ion beam or chemical initiators. Of these techniques, radiation method is one of the useful methods because of uniform and rapid creation of active radical sites without catalytic contamination in grafted samples. If the diffusion of monomer into polymer is large enough to come to the inside of polymer substrate, a homogeneous and uniform grafting reaction can be carried out throughout the whole polymer substrate. Radiation-induced grafting method may attach specific functional moieties to a polymeric substrate, such as preirradiation and simultaneous irradiation. The former is irradiated at backbone polymer in vacuum or nitrogen gas and air, and then subsequent monomer grafting by trapped or peroxy radicals, while the latter is irradiated at backbone polymer in the presence of the monomer. Therefore, radiation-induced polymerization can be used to modification of the chemical and physical properties of the polymeric materials and has attracted considerable interest because it imparts desirable properties such as blood compatibility. membrane quality, ion excahnge, dyeability, protein adsorption, and immobilization of bioactive materials. Synthesizing biocompatible materials by radiation method such as preirradiation or simultaneous irradiation has often used $\gamma$-rays to graft hydrophilic monomers onto hydrophobic polymer substrates. In this work, in attempt to produce surfaces that show low levels of anti-fouling of bovine serum albumin(BSA) solutions, hydroxyethyl methacrylate(HEMA) was grafted polypropylene membrane surfaces by preirradiation technique. The anti-fouling effect of the polypropylene membrane after grafting was examined by permeation BSA solution.

  • PDF

Enhancement of lower critical field of MgB2 thin films through disordered MgB2 overlayer

  • Soon-Gil, Jung;Duong, Pham;Won Nam, Kang;Byung-Hyuk, Jun;Chorong, Kim;Sunmog, Yeo;Tuson, Park
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권4호
    • /
    • pp.1-5
    • /
    • 2022
  • We investigate the effect of surface disorder on the lower critical field (Hc1) of MgB2 thin films with a thickness of 850 nm, where the disorder on the surface region is produced by the irradiation of 140 keV Co ions with the dose of 1 × 1014 ions/cm2. The thickness of the damaged region by the irradiation is around 143 nm, corresponding to ~17% of the whole thickness of the film, thereby forming the disordered MgB2 overlayer on the pure MgB2 layer. The magnetic field dependence of magnetization, M(H), for the pristine MgB2 thin film and the film with overlayer is measured at various temperatures, and Hc1 is determined from the difference (△M) between the Meissner line and magnetization signal with the criterion of △M = 10-3 emu. Intriguingly, the film with the disordered overlayer shows a remarkably large Hc1(0) = 108 Oe compared to the Hc1(0) = 84 Oe of pristine film, indicating that the disordered MgB2 overlayer on the pure MgB2 layer serves to prevent the penetration of vortices into the sample. These results provide new ideas for improving the superheating field to design high-performance superconducting radio-frequency cavities.

Micro-Spot Atmospheric Pressure Plasma Production for the Biomedical Applications

  • Hirata, T.;Tsutsui, C.;Yokoi, Y.;Sakatani, Y.;Mori, A.;Horii, A.;Yamamoto, T.;Taguchi, A.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.44-45
    • /
    • 2010
  • We are currently conducting studies on culturing and biocompatibility assessment of various cells such as neural stem cells and induced pluripotent stem cells(IPS cells) on carbon nanotube (CNT), on nerve regeneration electrodes, and on silicon wafers with a focus on developing nerve integrated CNT based bio devices for interfacing with living organisms, in order to develop brain-machine interfaces (BMI). In addition, we are carried out the chemical modification of carbon nanotube (mainly SWCNTs)-based bio-nanosensors by the plasma ion irradiation (plasma activation) method, and provide a characteristic evaluation of a bio-nanosensor using bovine serum albumin (BSA)/anti-BSA binding and oligonucleotide hybridization. On the other hand, the researches in the case of "novel plasma" have been widely conducted in the fields of chemistry, solid physics, and nanomaterial science. From the above-mentioned background, we are conducting basic experiments on direct irradiation of body tissues and cells using a micro-spot atmospheric pressure plasma source. The device is a coaxial structure having a tungsten wire installed inside a glass capillary, and a grounded ring electrode wrapped on the outside. The conditions of plasma generation are as follows: applied voltage: 5-9 kV, frequency: 1-3 kHz, helium (He) gas flow: 1-1.5 L/min, and plasma irradiation time: 1-300 sec. The experiment was conducted by preparing a culture medium containing mouse fibroblasts (NIH3T3) on a culture dish. A culture dish irradiated with plasma was introduced into a $CO_2$-incubator. The small animals used in the experiment involving plasma irradiation into living tissue were rat, rabbit, and pick and are deeply anesthetized with the gas anesthesia. According to the dependency of cell numbers against the plasma irradiation time, when only He gas was flowed, the growth of cells was inhibited as the floatation of cells caused by gas agitation inside the culture was promoted. On the other hand, there was no floatation of cells and healthy growth was observed when plasma was irradiated. Furthermore, in an experiment testing the effects of plasma irradiation on rats that were artificially given burn wounds, no evidence of electric shock injuries was found in the irradiated areas. In fact, the observed evidence of healing and improvements of the burn wounds suggested the presence of healing effects due to the growth factors in the tissues. Therefore, it appears that the interaction due to ion/radicalcollisions causes a substantial effect on the proliferation of growth factors such as epidermal growth factor (EGF), nerve growth factor (NGF), and transforming growth factor (TGF) that are present in the cells.

  • PDF