• Title/Summary/Keyword: Bus Operation Management

Search Result 85, Processing Time 0.023 seconds

Fault Management Design Verification Test for Electrical Power Subsystem and Attitude and Orbit Control Subsystem of Low Earth Orbit Satellite (저궤도위성의 전력계 및 자세제어계 고장 관리 설계 검증시험)

  • Lee, Sang-Rok;Jeon, Hyeon-Jin;Jeon, Moon-Jin;Lim, Seong-Bin
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.14-23
    • /
    • 2013
  • Fault management design of the satellite describes preparations for failures which can occur during operational phase. Fault management design contains detection and isolation function of anomaly, and also it contains function to maintain the satellite in safe condition until the ground station finds out a cause of failure and takes a countermeasure. Unlike normal operation, safing operation is automatically performed by Power Control and Distribution Unit and Integrated Bus Management Unit which loads Flight Software without intervention of ground station. Since fault management operation is automatical, fault management logic and functionality of relevant hardware should be thoroughly checked during ground test phase, and error which is similar to actual should be carefully applied without damage. Verification test for fault management design is conducted for various subsystems of satellite. In this paper, we show the design process of fault management design verification test for Electrical Power Subsystem and Attitude and Orbit Control Subsystem of Low Earth Orbit satellite flight model and the test results.

Quality Control Scheme of GIS-based Bus Network for Stabilization of BIS - Focusing on Real-Time Public Transportation Information (BIS 안정화를 위한 버스기반정보 GIS DB 품질 관리 방안 - 실시간 환승교통 종합정보 시스템을 사례로)

  • Ju, Yong-Jin;Ham, Chang-Hak
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.1
    • /
    • pp.33-41
    • /
    • 2012
  • BIS is an arrival guidance system which is able to supply passengers with bus service condition via Kiosks at a bus stop, internet and mobile service through pinpointing bus location in real time. It is very significant to improve the quality of traffic information by quality control of GIS-based bus network so as to maintain navigational information and to implement reliable BIS. Therefore this study aims to build criteria to quantitatively evaluate data quality of the product in accordance with the process in bus network data and to suggest guideline of quality control. To achieve this, we have categorized geometric and logical errors occurring during constructing bus network database by giving a specific case study on TAGO and set up sectional guideline and procedures to examine database for systematic and coherent quality control management. Proceeding from what has been said above, the outcome of our research leads to quality guarantee for objective and reliable bus network database and is fully expected to bring benefit of providing a more accurate public transportation information and improving reliability of BIS through preventing a variety of errors in system operation in advance.

Optimum Allocation of Reactive Power in Real-Time Operation under Deregulated Electricity Market

  • Rajabzadeh, Mahdi;Golkar, Masoud A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.337-345
    • /
    • 2009
  • Deregulation in power industry has made the reactive power ancillary service management a critical task to power system operators from both technical and economic perspectives. Reactive power management in power systems is a complex combinatorial optimization problem involving nonlinear functions with multiple local minima and nonlinear constraints. This paper proposes a practical market-based reactive power ancillary service management scheme to tackle the challenge. In this paper a new model for voltage security and reactive power management is presented. The proposed model minimizes reactive support cost as an economic aspect and insures the voltage security as a technical constraint. For modeling validation study, two optimization algorithm, a genetic algorithm (GA) and particle swarm optimization (PSO) method are used to solve the problem of optimum allocation of reactive power in power systems under open market environment and the results are compared. As a case study, the IEEE-30 bus power system is used. Results show that the algorithm is well competent for optimal allocation of reactive power under practical constraints and price based conditions.

A Study on the Enhancement of Accuracy of Network Analysis Applications in Energy Management Systems (계통운영시스템 계통해석 프로그램 정확도 향상에 관한 연구)

  • Cho, Yoon-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.88-96
    • /
    • 2015
  • This paper describes a new method for enhancing the accuracy of network analysis applications in energy management systems. Topology processing, state estimation, power flow analysis, and contingency analysis play a key factor in the stable and reliable operation of power systems. In this respect, the aim of topology processing is to provide the electrical buses and the electrical islands with the actual state of the power system as input data. The results of topology processing is used to input of other applications. New method, which includes the topology error analysis based on inconsistency check, coherency check, bus mismatch check, and outaged device check is proposed to enhance the accuracy of network analysis. The proposed methodology is conducted by energy management systems and the Korean power systems have been utilized for the test systems.

Development and Evaluation of Real-time Travel Time Forecasting Model: Nonparametric Regression Analysis for the Seoul Transit System (비모수 회귀분석을 이용한 실시간 통행시간 예측 기법 개발 및 평가 (서울시 버스를 중심으로))

  • Park, Sin-Hyeong;Jeong, Yeon-Jeong;Kim, Chang-Ho
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.1 s.87
    • /
    • pp.109-120
    • /
    • 2006
  • Since the 1st of July, 2004, the public transport system of the Seoul metropolitan area has been rearranged. In the new system, bus lines are divided into 4 classes-wide area, arterial road, branch, and rotation lines with renewed fare system based on the total distance travelled. Since central control center known as the Bus Management System (BMS) integrates the entire system operation. it now becomes feasible to collect travel information and provide it to the users scientifically and systematically. The Purpose of this study is to forecast transit travel time using real-time traffic data coming from both buses and subway. This is significant contribution since provision of real-time transit information and easy access to it would most likely boost the use of mass transit system, alleviating roadway congestion in the metropolitan area.

Evaluation of Trail Facility and Operation-Management for Walking Tour Revitalization - focus on Ganghwa Nadeul-gil - (도보여행 활성화를 위한 탐방로 시설 및 운영 관리 실태 평가 - 강화 나들길을 중심으로 -)

  • Shin, Sunmi;Byun, Byungseol
    • Journal of Wetlands Research
    • /
    • v.17 no.2
    • /
    • pp.176-183
    • /
    • 2015
  • This study is aimed at deducting the evaluation standard of the walking tour trail and evaluating the real condition of trail facilities and operation & management. On the basis of the research on the walking tour, this study deducted the evaluation index of the trail facilities and administrative control, and divided it into visit resources, visit facilities and trail operation-management. This study selected the course of high use satisfaction among the Ganghwa Nadeul-gil section, and evaluated the real condition of Ganghwa Nadeul-gil trail by classifying the route as nature-oriented trail and culture-oriented trail. In case of nature-oriented trail, it's necessary to discover living culture resources of the village linked with the trail, and to develop amenities using bus stations and supermarket. In case of culture-oriented trail, it's required that economic regeneration plan should be arranged using the declining facilities.

Development of Hardware In-the-Loop Simulation System for Testing Power Management of DC Microgrids Based on Decentralized Control (분산제어 기반 직류 마이크로그리드 전력관리시스템의 HIL 시뮬레이션 적용 연구)

  • To, Dinh-Du;Le, Duc-Dung;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.191-200
    • /
    • 2019
  • This study proposes a hardware-in-the-loop simulation (HILS) system based on National Instruments' PXI platform to test power management and operation strategies for DC microgrids (MGs). The HILS system is developed based on the controller HIL prototype, which involves testing the controller board in hardware with a real-time simulation model of the plant in a real-time digital simulator. The system provides an economical and effective testing function for research on MG systems. The decentralized power management strategy based on the DC bus signaling method for DC MGs has been developed and implemented on the HILS platform. HILS results are determined to be similar to those of the off-line simulation in PSIM software.

A Study on the Operational Characteristics of a Squirrel-cage type Wind Turine Induction Generator (농형 풍력 유도발전기의 운전 특성에 관한 연구)

  • Jang, Sung-Il;Jeong, Jong-Chan;Choi, Jeong-Hwan;Park, Je-Young;Kim, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1309-1312
    • /
    • 2002
  • The electric power network paralleled with wind turbine generator may have the negative impacts on the protection, operation, and management caused by the operation of wind turbine generator. Therefore, it is necessary to investigate the operating characteristic of wind turbine generator. This paper describes model of a squirrel-cage type wind turbine induction generator and the soft cut-in connection method for reducing the transient state on power network, and simulates various cases of wind turbine operations. The radial distribution network of IEEE 13-bus are modeled and tested by PSCAD/EMTDC.

  • PDF

A Study on Probabilistic Reliability Evaluation Considering Transmission System :TRELSS and TranRel (송전계통을 고려한 확률론적 신뢰도 평가에 관한 연구 : TRELSS and TranRel)

  • 최재석;강성록;트란트롱틴;전동훈;문승필;추진부
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.43-55
    • /
    • 2004
  • This paper presents a study on evaluating the reliability indices considering a transmission system. Because successful operation of electric power under the deregulated electricity market depends on transmission system reliability management, quantity evaluation of transmission system reliability is very important. This paper introduces features and operation modes of the Transmission Reliability Evaluation for Large-Scale Systems(TRELSS) Version 6.0, a commercial program made in EPRI, and TranRel-I V3.2, a educational program made in GSNU(GyeongSang National University) for assessing reliability indices of composite power system. The packages access not only bulk but also bus indices for reliability evaluation of composite powers system. The practicality, effectiveness and future works of this methodology are illustrated by demonstrations of two case studies of modified IEEE 25 buses reliability test system using TRELSS and TranRel-I and a brief case study for the KEPCO size system using TranRel-II made in GSNU.

A Study on the Improving Effectiveness of Shipboard Electric Propulsion System with Ultra-capacitor Energy Storage Devices (울트라 캐패시터 에너지 저장장치를 적용한 함정 전기추진 시스템의 효용성 증대 연구)

  • Kim, So-Yeon;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.114-120
    • /
    • 2012
  • Recently, integrated electric propulsion system has been vigorously adopted into naval vessels. To enhance effectiveness and efficiency of power management in these propulsion systems, this paper investigates necessity of energy storage devices and their operation strategies. By introducing the energy storage devices, engine can operate at higher efficiency point and accordingly costs for fuel and maintenance are significantly reduced. In addition, transient performance can also be improved with support of the devices and it leads to stable operation of shipboard power bus. To validate the proposal of this paper, computer simulation has been conducted with real load data of existing electric propulsion system.