• Title/Summary/Keyword: Bur

Search Result 359, Processing Time 0.026 seconds

Sparganium glomeratum (Typhaceae): A new record from South Korea

  • GIL, Hee-Young;LEE, Kang-Hyup;HA, Young-Ho;JANG, Chang-Seok;KIM, Dong-Kap
    • Korean Journal of Plant Taxonomy
    • /
    • v.49 no.4
    • /
    • pp.374-379
    • /
    • 2019
  • In this study, we report a new record of the clustered bur-reed Sparganium glomeratum (Laest. ex Beurl.) Beurl., from Yongneup Moor of Daeamsan Mt. in Gangwon-do, Korea. This species is distributed in the cool temperate and circumboreal regions of the Northern Hemisphere. As we recorded this species in a high-altitude wetland, we named it "Du-me-heuk-sam-neung" after the Korean word that translates to "Sparganium found in deep mountains." We provide descriptions of the morphological characteristics, photographs, and detailed illustrations of S. glomeratum, as well as a key to allied taxa in Korea.

Comparison of microtensile bond strength on non-carious cervical lesions according to biofilm removal method (생체막 제거 방법에 따른 비우식성 치경부 병소의 미세인장강도 비교)

  • Sung, Kun-Hwa;Min, Jeong-Bum;Park, Tae-Young
    • The Journal of the Korean dental association
    • /
    • v.58 no.11
    • /
    • pp.683-689
    • /
    • 2020
  • Dentin surface of non-carious lesion is usually attached with oral biofilm. The biofilm should be removed before application of restorative material, because it may reduce the bond strength of adhesive system. The aim of this study was to evaluate the microtensile bond strength, when the biofilm was removed with brush or bur. Twenty extracted human third molars were sectioned horizontally to obtain dentin surface. Specimen were divided randomly into four group. Biofilm formation was performed in three group, except for Group 1 (negative control). Biofilm was removed as follows: Group 3, using ICB brush; Group 4, using lowspeed round bur #2. Group 2 (positive control) was not removed Biofilm. And in all four groups, the adhesive system (Optibond FL, Kerr) was applied to etched dentin surface, and resin composite was built up in three 1mm increments. After 24 hour storage in distilled water, the teeth were perpendicularly sectioned to obtain beams (1 × 1 mm2). Microtensile bond strength was measured and the data were statistically analyzed using one-way ANOVA and Tukey's post hoc test (p<0.05). Group 4 showed the highest microtensile bond strength (p<0.05), Group 3 showed no significant improvements when compared to Group 1. Group 2 showed lowest microtensile bond strength (p<0.05). When restoring a non-carious cervical lesion, it is essential to remove the biofilm present on the dentin surface. In addition, in the method of removing the biofilm, both the brush removal method and the bur removal method were effective.

  • PDF

Effects of metal surface grinding at the porcelain try-in stage of fixed dental prostheses

  • Kilinc, Halil Ibrahim;Kesim, Bulent;Gumus, Hasan Onder;Dincel, Mehmet;Erkaya, Selcuk
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.317-324
    • /
    • 2014
  • PURPOSE. This study was to evaluate the effect of grinding of the inner metal surface during the porcelain try-in stage on metal-porcelain bonding considering the maximum temperature and the vibration of samples. MATERIALS AND METHODS. Ninety-one square prism-shaped ($1{\times}1{\times}1.5mm$) nickel-chrome cast frameworks 0.3 mm thick were prepared. Porcelain was applied on two opposite outer axial surfaces of the frameworks. The grinding was performed from the opposite axial sides of the inner metal surfaces with a low-speed handpiece with two types of burs (diamond, tungsten-carbide) under three grinding forces (3.5 N, 7 N, 14 N) and at two durations (5 seconds, 10 seconds). The shear bond strength (SBS) test was performed with universal testing machine. Statistical analyzes were performed at 5% significance level. RESULTS. The samples subjected to grinding under 3.5 N showed higher SBS values than those exposed to grinding under 7 N and 14 N (P<.05). SBS values of none of the groups differed from those of the control group (P>.05). The types of bur (P=.965) and the duration (P=.679) did not affect the SBS values. On the other hand, type of bur, force applied, and duration of the grinding affected the maximum temperatures of the samples, whereas the maximum vibration was affected only by the type of bur (P<.05). CONCLUSION. Grinding the inner metal surface did not affect the metal-porcelain bond strength. Although the grinding affected the maximum temperature and the vibration values of the samples, these did not influence the bonding strength.

AN ELECTROCHEMICAL STUDY ON MICROLEAKAGE OF RETROGRADE FILLING USING DIFFERENT RETROGRANE FILLING MATERIALS, ROOT RESECTION ANGLE AND CAVITY PREPARATION INSTRUMENTS (역충전재 및 치근단 절제 각도와 와동 형성 기구에 따른 역충전물의 변연 누출에 관한 전기화학적 연구)

  • Kim, Jin-Woo;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.499-512
    • /
    • 1994
  • The purpose of this study was to evaluate the microleakage electrochemically using different retrograde filling materials, different root resection angle, and different cavity preparation instruments. 104 extracted single-rooted teeth were selected for this study. 100 teeth were used as experimental groups and four was used as controls. Anatomical crowns were resected, root canals were prepared, and the apical 2 mm of roots were removed. The experimental roots were randomly divided into five equal groups. Experimental groups : Group 1. no bevel, cavity preparation with ultrasonic instruments, amalgam filling Group 2. no bevel, cavity preparation with ultrasonic instruments, SuperEBA cement filling Group 3. no bevel, cavity preparation with ultrasonic instruments, desiccated ZOE filling Group 4. $45^{\circ}$ bevel, cavity preparation with ultrasonic instruments, amalgam filling Group 5. no bevel, cavity preparation with conventional bur, amalgam filling Microleakage was measured once a day for 30 days using electrochemical method and were analyzed statistically. The results were as follows : 1. The group with Super EBA cement filling showed the least marginal leakage from second to fourth day(p<0.05), there was no significant difference between the group with amalgam filling during eighth to eighteenth day(p>0.05), but after the nineteenth day here was a higher marginal leakage than the group with amalgam filling(p<0.05). 2. The group with desiccated ZOE filling demostrated that the highest marginal leakage, started on the eighth day(p<0.05). 3. The group using ultrasonic instrument showed lower marginal leakage than the group using bur until the nineteenth day(p<0.05), but there was no significant differnce with the group using bur after twentythird day(p>0.05). 4. The group without bevel showed lower marginal leakage than the group with bevel (p<0.05). 5. Whether bevel or nor had much more effect on marginal leakage than with cavity perparation instrument when the cavity was retrogrdefilled with amalgam(stepwise regression).

  • PDF

A STUDY ON THE REMOVAL OF DENTINAL SMEAR LAYER BY DENTIN CONDITIONER (상아질처리제(象牙質處理劑)에 의(依)한 상아질(象牙質) 표면(表面) 도말층(塗抹層)의 제거(除去)에 관(關)한 연구(硏究))

  • Ahn, Hyun-Mi;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.65-76
    • /
    • 1989
  • The purpose of this study was to observe the effect on the removal of dentinal smear layer and morphological changes of reduced dentin surfaces by various dentin surface conditioners. Thirty-two healthy human premolars extracted due to periodontal or orthodontic reasons were used. The teeth were cross-sectioned to expose dentin at the middle portion of the crown with diamond rotary saw. The specimens were then divided into 8 groups. The sectioned dentin surfaces in group 1 to 4 were grinded with No. 400 grit silicone abrasive paper and those in group 5 to 8 were cut with #700 carbide bur under air-water spray. The grinded or cut dentin surfaces were conditioned with 3% $H_2O$, Dentin Conditioner(GC Inter. Corp., Japan), and Scotchprep(3M Dent Prod., U.S.A) according to manufacturer's directions. All the specimens were dried in room temperature for 48 hours, and gold-coated with Eiko ion coater(Eik-engineering Co.), and observed in Hitachi S-450 Scanning electron microscope at 15-25 KV. The following results were obtained; 1. The dentin surfaces grinded with the silicon abrasive paper were rougher in texture and heavier in amount of smear layer than those cut with the carbide bur. 2. Scrubbing of 3% $H_2O_2$ was not effective in removing dentinal smear layer. 3. 20-second conditioning of Dentin Conditioner (GC Inter. Corp) resulted in the removal of a significant amount of the smear layer without removing the tubular plugs and dissolving the peritubular dentin. 4. Scotchprep removed the smear layer very effectively. But at the same time it dissolved the peritubular dentin. 5. Irrespective of the uses of the silicon carbide abrasive paper or the carbide bur the morphological changes of dentin surfaces treated with the same conditioning agents were similar.

  • PDF

Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics

  • Zortuk, Mustafa;Gumus, Hasan Onder;Kilinc, Halil Ibrahim;Tuncdemir, Ali Riza
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.192-196
    • /
    • 2012
  • PURPOSE. The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. MATERIALS AND METHODS. In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and randomly assigned to four groups of dentin cleaning protocols (n = 9). Group 1 (control): Provisional cements were mechanically removed with a dental explorer. Group 2: The dentin surfaces were treated with a cleaning brush with pumice Group 3: The dentin surfaces were treated with a cleaning bur. Group 4: The provisional cements were removed by an Er:YAG laser. Self-adhesive luting cement was used to bond ceramic discs to dentin surfaces. Shear bond strength (SBS) was measured using a universal testing machine at a 0.05 mm/min crosshead speed. The data were analyzed using a Kolmogorov Smirnov, One-way ANOVA and Tukey HSD tests to perform multiple comparisons (${\alpha}$=0.05). RESULTS. The dentin cleaning methods did not significantly affect the SBS of ceramic discs to dentin as follows: dental explorer, pumice, cleaning bur, and Er:YAG laser. CONCLUSION. The use of different cleaning protocols did not affect the SBS between dentin and ceramic surfaces.

Finishing and polishing effects of multiblade burs on the surface texture of 5 resin composites: microhardness and roughness testing

  • Ehrmann, Elodie;Medioni, Etienne;Brulat-Bouchard, Nathalie
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.1
    • /
    • pp.1.1-1.12
    • /
    • 2019
  • Objectives: The aim of this in vitro study was to test the effect of 2 finishing-polishing sequences (QB, combining a 12/15-fluted finishing bur and an EVO-Light polisher; QWB, adding a 30-fluted polishing bur after the 12/15-fluted finishing bur used in the QB sequence) on 5 nanotech-based resin composites (Filtek Z500, Ceram X Mono, Ceram X Duo, Tetric Evoceram, and Tetric Evoceram Bulk Fill) by comparing their final surface roughness and hardness values to those of a Mylar strip control group (MS). Materials and Methods: Twelve specimens of each nanocomposite were prepared in Teflon moulds. The surface of each resin composite was finished with QB (5 samples), QWB (5 samples), or MS (2 samples), and then evaluated (60 samples). Roughness was analysed with an optical profilometer, microhardness was tested with a Vickers indenter, and the surfaces were examined by optical and scanning electron microscopy. Data were analysed using the Kruskal-Wallis test (p < 0.05) followed by the Dunn test. Results: For the hardness and roughness of nanocomposite resin, the QWB sequence was significantly more effective than QB (p < 0.05). The Filtek Z500 showed significantly harder surfaces regardless of the finishing-polishing sequence (p < 0.05). Conclusions: QWB yielded the best values of surface roughness and hardness. The hardness and roughness of the 5 nanocomposites presented less significant differences when QWB was used.

EFFECT OF VARIOUS MECHANICAL TREATMENTS OF HYDROXYAPATITE-COATED IMPLANT SURFACES (Hydroxyapatite 피막 처리된 임프란트에 대한 여러가지 기계적 표면처리방법이 임프란트 표면조도 및 성상에 미치는 영향)

  • Yang, Kyung-Ran;Jung, Oh-Chul;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.131-143
    • /
    • 1994
  • For maintenance of exposed implant in healthy state, it is necessary to treat the surface of implant fixture and provide the surface adjustable to surrounding tissues. Variable techniques have been introduced such as citric acid and air-abrasive system to treat the failed implant. Although when the rough surface of HA coated implant was exposed to oral environment, the surface treatment method with citric acid or air-abrasive system is effective for removal of bacterial endotoxin, it is unsuccessful to prevent plaque deposition due to difficulty in removal of rough surface of HA coated implant. Thus, in this study the method that removes bacterial endotoxin and makes smooch surface without alteration of surface characteristics was studied. HA coated disc manufactured by IMZ Co. Was treated with high speed diamond bur, low speed diamond bur, stone bur, rubber point, jetpolisher. And then its surface state was examined with profilometer and SEM to evaluate the surface smoothness, and its surface component was analyzed with EDX to evaluate wheter the surface characteristics were altered or not. As a result, following results were obtained. When the surface roughness of each implant disc was measured by profilometer, the group I showed a $R_{max}\;2.11{\mu}m$ and the group II, III, IV, V showed a $R_{max2}\;4.17{\mu}m$, $7.28{\mu}m$, $8.61{\mu}m$ and $39.44{\mu}m$ respectively. That is, surface smoothness was highest in the group I and it has been gradually decreased in the group II, III, IV and V. Under the SEM examination, the group I showed relatively smooth surface and the group II showed slightly rougher surface than the group I due to partially remaining HA particles while most HA particle was removed. The group III and IV showed rough topography due to HA particles that was not grinded, and HA coated surface in group V showed very irregular surface with deep groove and prominence. In cross-sectional view, the group I showed uniform surface, and the group III, IV showed rough surface due to remaining HA particles but the thickness of HA coating was remarkably reduced. The group II has similar pattern in group I, and the group V showed about $40{\mu}m$ thickness although it was not constant. By analysis of surface component with EDX, the group II in which the grinding was effective showed a small quantity of calcium and phosphorous and the group III, IV, in which the grinding was incomplete showed calcium and phosphorus peak. In all experimental group, no other than titanium, aluminum, calcium, phosphorus was observed.

  • PDF

A comparison study of the effects of handpiece speed on teeth in debonding procedure (탈접착 후처치시 핸드피스(handpiece) 속도가 치아에 미치는 영향에 대한 비교 연구)

  • Park, Soo-Byung;Kim, Gu-Ho;Ha, Man-Hee
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.83-91
    • /
    • 2004
  • This study was performed to examine treatment efficiency and patient discomfort rate according to used handpiece speed in clean-up technique. Brackets were bonded to extracted human premolar(50 teeth). After debonding, 50 extracted human premolar were divided Into each two groups(low speed handpiece group with tungsten carbide bur and high speed handpiece group with ultra-fine diamond finishing bur) of 25 according to used handpiece speed in clean-up technique. In clean-up procedure, teeth vibration and pulp thermal changes were measured. After clean-up procedure, the enamel surfaces of randomly selected 10 teeth from each two groups were taken by SEM and evaluated. The findings of this study were as follows ; 1. During resin removal, tooth vibrations of various amplitude in low speed handpiece group were more than those of high speed handpiece. 2. The pulpal thermal changes of high speed handpiece group were significantly higher than those of low speed handpiece group, also the resin removal time in high speed handpiece group was almost as twice as in low speed handpiece group. 3. The figures of SEM to enamel surfaces after resin removal showed that notches and resin remnants in high speed handpiece group were more than those in low speed handpiece group.

A Study on the Enamel Surface Texture and Caries Susceptibility in Interdentally Stripped Teeth (치간삭제 후의 법랑질 표면조도와 치아우식 감수성에 관한 연구)

  • Kim, Kyong-Nim;Yoon, Young-Ju;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.6 s.89
    • /
    • pp.567-578
    • /
    • 2001
  • To investigate the difference of Texture exhibited on interproximal enamel surface with each different stripping method and the susceptibility of proximal enamel to demineralization after stripping and the application of a topical fluoride go] and sealant, one hundred human premolars, which were Previously extracted for orthodontic reasons were evaluated by means of Scanning electron microscopy and laser fluorescence. The results were as follows : 1. No matter what the initial stripping instrument was the furrows that resulted from all the stripping methods were not completely removed by careful polishing. 2. Among the enamel surfaces that were treated with three different initial abrasive instruments, followed by the same polishing method (Sof-$Lex^{(r)}$ disks), the enamel surfaces that were treated with 700 crosscut carbide bur showed the smoothest surfaces. 3. The stripped teeth, no matter what the initial stripping instrument was, were less resistant to initial demineralization than untreated teeth. But no difference in caries susceptibility according to differently stripped methods was found (p<(0.001). 4. Teeth treated with APF-gel or sealant were mote resistant to demineralization than those treated without other treatment after stripping (p<0.001). 5. Comparing groups treated with APF-gel to groups treated with sealant, the former was more resistant to demineralization than the tatter (p<0.05). In conclusion, enamel surfaces that were stripped jnterproximally were less resistant to demineralization even though various attempts were made to produce smooth, self-cleaning enamel surfaces. Therefore, additional treatment-sealant or calcifying/ fluoridating solution To the stripped enamel surfaces is recommended.

  • PDF