• Title/Summary/Keyword: Building-to-Land Ratio

Search Result 137, Processing Time 0.03 seconds

A Study on the Physical Environment Characteristics of the Detached Housing Area in the Housing Site Development District (택지개발지구내 단독주택지의 물리적 환경특성에 관한 연구)

  • 박몽섭;하재명
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.43-51
    • /
    • 2004
  • The purpose of this study is to examine the physical characteristics of the detached housing area in the housing site development district. The process of this study is to investigate the characteristics of the physical structure and the building use, then to analyze the relationship of physical structure and the building use in the aspect of the morphological characteristics. The case study focuses on the Chil-kok2, An-Siml in Taegu. The streets pattern is composited gird and loop type mixed. The block is composited by 2 lots in general. But the obscurity of organization and character of the streets, the size and shape of lots which is not fit to the building use. A whole residential characters appears high residential density ratio. so residential environment became worse. The improving level of residential environment and efficiency of land use in the detached housing area of the housing site development district, firstly the propriety of the physical structure must be considered about detached house characters, and the housing uses which fit to the physical structure are needed, and also for the concrete realization of this, the designation of district, the zoning of residential area, the guideline of the district design, and establishment of comprehensive master planning in detached housing area are needed in aspect of the housing policy. As the result of this study, it suggests several design guideline to improve housing site development.

Evaluation of the Optimal Grouser Shape Ratio of Dozer Considering the Ground Conditions (지반 특성을 고려한 도저의 최적 그라우저 형상비 평가)

  • Baek, Sung-Ha;Kwak, Tae-Young;Choi, Changho;Lee, Seong-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.3
    • /
    • pp.31-41
    • /
    • 2021
  • A dozer is a construction machinery used to move soil mass along large open tracts of land. Soil thrust generated on the soil-track interface determines the performance of the dozer; to improve the tractive performance of the dozer, the outer surface of the continuous-track is designed to protrude with grousers. In this study, we calculated soil thrust of the dozer equipped with grousers with various shape ratios, and evaluated the optimal grouser shape ratio considering ground conditions. Grouser generated additional soil thrust on the side of the continuous-track (e.g., side soil thrust) and converted the shearing surface (e.g., from soil-track interface to soil-soil interface), increasing the soil thrust of dozer by about 1.3 to 1.6 times. The effect of grouser's shape ratio on the soil thrust of dozer differed with the relative density of the ground. As the shape ratios of grouser increased, soil thrust of dozer decreased at the relative density of 40% and increased at the relative density of 80%. Based on these results, it can be concluded that the shape ratio of grouser severely affects the dozer's performance; thus, careful consideration of the optimal shape ratio of grouser is of great importance in the mechanical design, evaluation, and optimization of the undercarriage of dozers.

An Integrated Water Budget Analysis of Oedocheon Watershed in Jeju Island (제주 외도천 유역의 통합 물수지 분석)

  • Kim, Nam Won;Chung, Il-Moon;Na, Hanna
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.471-480
    • /
    • 2015
  • Hydrologic component analysis was conducted to investigate water budget characteristics the Oedocheon watershed, Jeju Island. For this purpose, integrated SWAT-MODFLOW model was applied to this watershed for continuous surface water-groundwater modeling. Pasture and forest-deciduous are the major land use types and these affect general hydrologic component ratio. The spatio-temporal groundwater recharge can be obtained from SWAT and then distributed groundwater recharge can be reproduced by MODFLOW. The groundwater level variation was simulated with distributed groundwater pumping data. The water budget in this watershed was compared with the previous estimated result by Jeju-Do(2013). As this result considered discharge to the coastal side, the discrepancy was found. However, it was found that the overall tendency of both analyses were similar.

Shear forces amplification due to torsion, explicit reliance on structural topology. Theoretical and numerical proofs using the Ratio of Torsion (ROT) concept

  • Bakas, Nikolaos
    • Structural Engineering and Mechanics
    • /
    • v.61 no.1
    • /
    • pp.15-29
    • /
    • 2017
  • The recently introduced index Ratio Of Torsion (ROT) quantifies the base shear amplification due to torsional effects on shear cantilever types of building structures. In this work, a theoretical proof based on the theory of elasticity is provided, depicting that the ratio of torsion (ROT) is independent of the forces acting on the structure, although its definition stems from the shear forces. This is a particular attribute of other design and evaluation criteria against torsion such as center of rigidity and center of strength. In the case of ROT, this evidence could be considered as inconsistent, as ROT is a function solely of the forces acting on structural members, nevertheless it is proven to be independent of them. As ROT is the amplification of the shear forces due to in-plan irregularities, this work depicts that this increase of internal shear forces rely only on the structural topology. Moreover, a numerical verification of this theoretical finding was accomplished, using linear statistics interpretation and nonlinear neural networks simulation for an adequate database of structures.

Numerical Simulation on the Effect of the Land Coverage Change on the Urban Heat Budget (토지피복 변화가 도시열수지에 미치는 영향에 관한 수치시뮬레이션)

  • Kim, Sang-Ok;Yeo, In-Ae;Ha, Kyung-Min;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.176-179
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed using 3-Dimensional Urban Canopy Model. The characteristics of urban thermal environment was analyzed by classifying land coverage and increasing natural land coverage ratio. The results are as follows. The characteristics of the land coverage on urban thermal environment formation can be summarized by the effects like higher temperature on the artificial coverage, and the contrary effects on the natural coverage. When the water coverage 100% was made up, maximum temperature was declined by $5.5^{\circ}C$, humidity by the 6.5g/kg, wind velocity by 0.6m/s, convective sensible heat by $400W/m^2$ and the evaporative latent heat was increased by $370W/m^2$ compared to when artificial coverage 100% was formed. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analysing urban climate phenomenon.

  • PDF

A Case Study on the Application of Digital-Twin to Small-size Building Remodeling Processes (디지털 트윈을 적용한 소규모 건축물 대수선 프로세스 적용 사례 연구)

  • Park, Sung-Man;Kim, Yang-Gil;Ham, Nam-Hyuk;Kim, Jae-Jun
    • Journal of KIBIM
    • /
    • v.13 no.1
    • /
    • pp.1-12
    • /
    • 2023
  • The number of old buildings in Korea is increasing. According to a report from the Ministry of Land, Infrastructure and Transport, the proportion of old buildings increased from 29.0% in 2005 to 37.8% in 2009. However, the ratio of repairs to improve usability and improve the environment through problem improvement The proportion of old buildings was 72% in 2010, but decreased to 38% in 2020 and does not exceed 40%. The reason is that the difficulty of remodeling old buildings is more difficult than repairing new ones, and business estimates are difficult to predict. Accurately reflecting the current condition of a building in a repair project has a huge impact on time and budget. Accurate and detailed measurements are essential. Current repair methodologies require a lot of manpower, time and money to remodel an old building. Therefore, it is necessary to improve the remodeling methodology applied in the field. In this study proposed a Digital-Twin-based remodeling process that introduced various digital technologies such as 3D Scanning, BIM, Reverse Engineering, and Digital Fabrictation in consideration of the latest technologies used in recent construction projects. In addition, the process proposed in this study was applied to an actual small-scale building remodeling project and the results were analyzed. In addition, useful basic data were provided for the establishment of plans related to the repair process of buildings in the future.

Analysis of Land Use Characteristics Using GIS DB - A Case Study of Busan Metropolitan City in Korea - (GIS DB를 이용한 토지이용 특성 분석 - 부산광역시 건물 높이 시뮬레이션을 중심으로 -)

  • Min-Kyoung CHUN;Tae-Kyung BAEK
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.3
    • /
    • pp.52-64
    • /
    • 2023
  • As cities continue to develop rapidly, overcrowding, pollution, and urban sanitation problems arise, and the need to separate conflicting uses is emerging. From this perspective, there is no disagreement that urban land use should be planned. Therefore, all activities in land space must be predicted in advance and planned so that land use can be rationally established. This study used the constructed data to compare and analyze the use distribution characteristics of residential, commercial, and industrial areas in Busan Metropolitan City to identify the building area status, total floor area, and floor area ratio by use zone in districts and counties in Busan Metropolitan City. As a result, it was found that the residential area accounted for the largest proportion of the area by use zone at 51%, and that the residential area accounted for the largest proportion at 63% of the total floor area by use zone. And the analysis was conducted using a specialization coefficient that can identify regional characteristics based on land use composition ratio. Because it is difficult to determine the trend of the entire region just by counting the absolute value of the area, the area composition ratio was calculated and compared. Looking at the residential facilities among the specialization coefficients by use area, it is above 1.0 except for Gijang-gun, Sasang-gu, Saha-gu, and Jung-gu. Commercial facilities are over 1.0 except for Gijang-gun, Gangseo-gu, Nam-gu, Sasang-gu, and Saha-gu. Looking at industrial facilities, you can see that the industrial complex distribution area is Gangseo-gu (2.5), Gijang-gun (1.22), Sasang-gu (2.06), and Saha-gu (1.64). In addition, it was found that business facilities and educational welfare facilities were evenly distributed. Land use analysis was conducted through simulation of the current status of building heights according to each elevation in each use area and the height of buildings in each use area. In general, areas over 80m account for more than 43% of Busan City, showing that the distribution of use areas is designated in areas with high altitude due to the influence of topographical conditions.

Strategies for Acceleration of Damaged Area Restoration Project in the Development Restriction Zone

  • Park, Seong Yong;Jung, Sung Ae;Lee, Sang Jo;Chung, Jae Woo
    • Journal of People, Plants, and Environment
    • /
    • v.22 no.6
    • /
    • pp.641-651
    • /
    • 2019
  • The purpose of this study is to derive institutional improvement methods for promoting the Damaged Area Restoration Project in greenbelts. The current status of greenbelts in Gyeonggi-do, where greenbelts are extensively distributed was analyzed, and the relevant laws and regulations were reviewed to suggest measures to promote the restoration project. The area of damaged areas within greenbelts in Gyeonggi-do was 6,121,024 m2, accounting for about 0.52% of the total area of greenbelts, and more than 80% was found to be located in Namyangju (55.49%), Hanam (16.48%), and Siheung (8.68%). Various measures to improve the policy were examined as follows: reducing the minimum size of the restoration project area; adjusting baseline of recognizing range of damaged areas; introducing the right of claim for land sale; allowing long-term unexecuted urban parks to be replaced as alternative sites for parks and green spaces; simplifying administrative procedures; and allowing public participation. All of them are expected to promote the restoration project within greenbelts. In results, when the minimum size of area for the restoration project was reduced from 10,000 m2 into 5,000 m2, 3,000 m2 and 2,000 m2, the ratio of the number of combinable lots to the total number of lots increased from 4.4% to 18.8%, 38.8%, and 55.9% respectively in Namyangju. Morever, when the recognizable ranges of the restoration project were extended to the structures obtaining building permit as of March 30, 2016 and obtaining use approvals before December, 2017, the number of applicable lots increased by 5.1% and 9.2% respectively.

Seismic Performance Evaluation of Reinforced Concrete Shear Wall Systems Designed with Special and Semi-Special Seismic Details (특수 및 준특수 상세에 따른 철근콘크리트 전단벽의 내진성능평가)

  • Oh, Hae Cheol;Lee, Kihak;Chun, Young Soo;Kim, Tae Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.181-191
    • /
    • 2014
  • This research presents the nonlinear analysis model for reinforced concrete shear wall systems with special boundary elements as proposed by the Korean Building Code (KBC, 2009). In order to verify the analysis model, analytical results were compared with the experimental results obtained from previous studies. Established analytical model was used to perform nonlinear static and dynamic analyses. Analytical results showed that the semi-special shear wall improved significantly the performance in terms of ductility and energy dissipation as expected based on previous test results. Furthermore, nonlinear incremental dynamic analysis was performed using 20 ground motions. Based on computer analytical results, the ordinary shear wall, special shear wall and newly proposed semi-special shear wall systems were evaluated based on the methods in FEMA P965. The results based on the probabilistic approaches accounting for inherent uncertainties showed that the semi-special shear wall systems provide a high capacity/demand (ACMR) ratio owing to their details, which provide enough capacity to sustain large inelastic deformations.

Comparison assessment of semi-transparent solar cell for BIPV windows (반투과형 태양전지를 이용한 창호형 BIPV 건물의 환경성능 분석)

  • Chung, Min Hee
    • Land and Housing Review
    • /
    • v.11 no.1
    • /
    • pp.87-94
    • /
    • 2020
  • To implement the planning of zero-energy buildings, their energy performance must be improved, and renewable energy applications must also be included. To accelerate the use of renewable energies in such buildings, BIPVs should be actively used in windows and on roofs. Window-type BIPVs are being developed in various forms depending on the size, composition, area ratio of the window, specification of glass, and so on. To analyze the applicability of various solar cells as window-type BIPVs, in this study, we evaluated their applicability, at the current development level, by analyzing the indoor illuminance, heat gain and heat loss; the cooling, heating, and lighting energy levels; and the generation performance of the various solar cells. To enhance the future applicability of window type BIPV, we analyze the overall energy performance of the building, according to changes in visible light transmittance and generation efficiency. The main research results are as follows. The area ratios above the standard illuminance, based on the window type and according to the VLT, were in order of low-e glazing, a-Si window, DSSC window, and c-Si window. The heat gain of the semi-transparent solar cell winodw was remarkably low. The energy consumption of buildings was highest in the order of c-Si window, DSSC window, a-Si window, and clear low-e window. However, in the case of including the power generation performance of the solar cell, the energy consumption was found to be high in order of DSSC window, c-Si window, a-Si window, and clear low-e window. In the future, if a window-type BIPV is developed, we believe that improvement in power generation performance and improvement in visible light transmittance will be needed.