• 제목/요약/키워드: Building thermal performance

검색결과 634건 처리시간 0.03초

VAV 시스템의 현장 운전방식에 따른 에너지 성능평가 (Energy Performance Evaluation of VAV System through Various Operating Strategies in Office Buildings)

  • 서종욱;허정호
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.184-193
    • /
    • 2004
  • The purpose of this study is to evaluate the performance of various control strategies in commercial buildings which have been operated by the variable air volume (VAV) system. Two buildings in Seoul were chosen for the field study. The one (D building) combined by LonWorks has the constant airflow of supply fan and the proportional control of VAV units (damper type). The other (S building) combined by DDC has the PI control mode of the supply fan and the floating control of VAV units (venturi type). In estimating thermal comfort and energy performance through control modes of PI, PID, and CAV in the supply fan, we could identify several energy efficient operating control strategies for the VAV system.

고효율에너지기자재 고기밀성 단열창호의 단열성능 평가 연구 (A Evaluation Analysis on Thermal Performance of High Airtight and Insulated Window of High Efficiency Energy Equipment)

  • 장철용;방주영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.227-230
    • /
    • 2009
  • Currently the country's foreign energy dependence reaches approximately 97% and the total energy consumption percentage of buildings(commercial and domestic parts) reaches approximately 24%. Building energy saving by enhanced insulation will be very important issue. Therefore, the solution is required to reduce energy loss and increasing displeasure caused by excessive influx of solar energy through windows, to solve the problems like decoloration on indoor furniture an clothes by harmful ultraviolet rays, air conditioning and increased cost. This research used for commercialization and ills semination by basic information through a evaluation on insulation performance of the window of high efficiency energy equipment which can improve the insulation performance.

  • PDF

TMY2 방식에 의한 국내 기상자료 작성 연구 (TMY2 Weather data for Korea)

  • 신기식;윤창렬;박상동
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.243-246
    • /
    • 2009
  • To evaluate the building energy performance, many building simulation programs are used and its capabilities are developed. Despite of its increased capabilities the weather data used In the Building Energy performance evaluation, are still using the same limited set of data. This often forces users to find or calculate weather data such as illuminance, solar radiation, and ground temperature from other sources to calculate it. Also, proper selection of a right weather data set has been considered as one of important factors for a successful building energy simulation. In this paper, we describe TMY2 data, a generalized weather data format developed for use, and applied to Seoul region and examine the differences comparing to existing weather data. A set of 23 years raw weather data base has been developed to provide the weather data file for building energy analysis in Seoul.

  • PDF

자연 대류식 태양열 집열기 (TAP)의 설계와 평가 (A Design of Thermosiphoning Air Panel and its Performance Analyzing)

  • 신희영;이경희
    • 태양에너지
    • /
    • 제4권2호
    • /
    • pp.51-57
    • /
    • 1984
  • The aim of the study is to the thermal performance of TAP (Thermosiphoning Air Panel) which is easily applicable to existing building as well as new building. TAP is one of the advantageous means of passive solar system, with a view to reducing the energy consumption of existing and new building. The instantaneous thermal efficency of a thermo siphoning collector depends primarily on the heat loss coefficient of the collector, the effectiveness of heattransfer between the absorber and the air, the average air temperature in the collector, the ambient air temperature, and the transmitted solar radiation. Because the important design variables are interrelated, it is, difficult to determine the effect of design decisions based on intuition. Therefore economical and effective TAP can be used easily, TAP had been designed and analyzed.

  • PDF

단열창호 슈퍼윈도우의 열성능 평가 (The Evaluation of Thermal Performance in Insulated Super Window system)

  • 장철용;조수;박상우
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.286-290
    • /
    • 2009
  • Generally the window of the building is an objective of mining and having a distant view and also for a circulation it will can open and shut because becomes the structure insulation, the meat detailed drawing it does a very difficult portion, it is. To reduce the loss of the energy which leads, to an air conditioning energy and an expense increase problem the color which the interior furniture and the clothing due to the augmentation and the corpse ultraviolet rays of the unpleasant feeling which is caused by with the transient one solar energy influx which leads the window will burn, it joins in the window and it confronts and the novel solution is demanded.

  • PDF

단열성능향상 재료를 사용한 콘크리트의 열전도 특성에 관한 연구 (Study on the Thermal Conduction of Concrete using Insulation Performance Improvement Materials)

  • 김정호;박영신;김상헌;전현규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.280-281
    • /
    • 2014
  • Recently, it is certain that the increase of heating and cooling energy consumption by radical change in climate condition has caused serious problems related to environmental and energy concerns associated with increase of fossil fuel usage and carbon dioxide production as well as global warming. Therefore, various actions to reduce greenhouse gas and energy consumption have been prepared by world developed countries. The energy consumption by buildings approximately reaches 25% of total korea energy consumption. The greatest part in the buildings of the energy consumption is building facade. But a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research is structural insulation concrete what improved insulation performance using micro form admixture and calcined diatomite powder and lightweight aggregate.

  • PDF

단열성능향상 재료를 혼합 사용한 콘크리트의 열전도 특성에 관한 연구 (Study on the Thermal Characteristics of Concrete Using Insulation Performance Improve Material Complex)

  • 박영신;김정호;강성혁;김세환;류동우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.40-41
    • /
    • 2013
  • The energy consumption by buildings approximately reaches 25% of total korea energy consumption. The greatest part in the buildings of the energy consumption is building facade. but a few research projects on concrete compising more than 70% of outsider of buildings has been tried. This research is structural insulation concrete what improved insulation performance using micro form admixture and calcined diatomite powedr and lightweight aggregate.

  • PDF

An Analytical Study on Indoor Thermal Comfort Performance According to the Automatic Control of Internal-External Blind

  • Lee, Do-Hyung;Kim, Tae-Woo;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • 제14권3호
    • /
    • pp.31-38
    • /
    • 2014
  • The purpose of this study is to analyse PMV (Predicted Mean Vote) and PPD (Predicted Percentage of dissatisfied) by automatic control of slat-type vertical blind. EnergyPlus, a building energy analysis software has been used for this study. The energy model is calibrated in Energy Plus using measured zone temperature and glass surface temperature data for one day and thermal comfort performance inside the building analysis was carried out. The calibrated data has the MBE of 4% and Cv(RMSE) of 10%. The result was that, for better zone thermal comfort, installation of blind on the outside is more appropriate than inside or no blind case. Additionally, different glazing types were compared and it was found that Triple Low-e glass is the most favorable.

An Experimental Study on the Thermal Performance of Cement Mortar with Granulated PCM

  • Jeong, You-Gun;Park, Ki-Bong;Lee, Han-Seung
    • 한국건축시공학회지
    • /
    • 제12권5호
    • /
    • pp.548-557
    • /
    • 2012
  • In this study the thermal performance of G-PCM replaced for find aggregate in mortar specimens was evaluated using TG-DTA. As a result, it was found that when solid changed into liquid, it absorbed heat, and when liquid changed into solid, it radiated heat. In addition, the fluidity and the compressive strength of mortar with G-PCM can be applied to the floor mortar and a wall finish material. Also the higher the replacement ratio, the larger the latent heat capacity. It was found that the mortar with G-PCM slowed the increase and decrease of temperature. Thus, the duration of pleasant indoor temperature is extended by the floor and wall mortar with G-PCM. In conclusion, G-PCM is expected to reduce the heating energy consumption.

에너지 절감형 전기히터를 활용한 동절기 양생품질 관리방안 (A Study on Cold-Weather Curing Quality Management Based on Using Energy Saving Electronic Heater)

  • 조만기;홍성민;박종훈;김진식;이동현;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2020
  • In This study, we tried to review an efficient curing method in consideration of safety and constructability among the problems of winter construction. In other words, as a result of the mock-up test, the measured value of carbon monoxide was 0 ppm in the case of an electric hot air fan. Since there is no carbon monoxide, problems such as suffocation are expected to be solved. In terms of temperature characteristics, electric hot air fans exhibited high thermal efficiency performance with a slight difference in upper/lower temperatures compared to the existing ones. In the future, we plan to conduct thermal efficiency evaluation through actual site performance verification. We will propose an efficient curing method through applicability evaluation.

  • PDF