• 제목/요약/키워드: Building regulations

검색결과 523건 처리시간 0.022초

인체에 대한 진동의 허용 기준 및 피해 산정에 관한 연구 (Vibration Regulations and Damages Evaluation Method for Human)

  • 양형식;전양수;이경운
    • 터널과지하공간
    • /
    • 제7권4호
    • /
    • pp.310-322
    • /
    • 1997
  • New limits of comfort boundary, psychological damage boundary and exposure limit for building residents by continuous and vibration are suggested. These limits are derived from the ISO 2631 and DIN 4150 regulations. A reasonable method to evaluate damages by vibrations is also suggested using the "total over-exposure of vibration" concept.; concept.

  • PDF

신축 공동주택의 누기특성 및 기밀성능 분석에 관한 연구 (The Air Leakage Characteristics and Airtightness Performance of a Newly Built Apartment)

  • 이윤규;신철웅
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.606-611
    • /
    • 2013
  • In responding to the recent framework convention on climate change, and the rise of the need for energy efficient buildings, such as Zero Energy Buildings (ZEB), domestic insulation standards and energy conservation regulations are being reinforced, to prevent heat loss. Accordingly, the Ministry of Land, Infrastructure and Transport have made amendments in Chapter 21 "Enforcement regulations for building facilities standards etc.", and Chapter 22 "Energy conservation standard", to reflect these changes. To effectively implement these regulations, it is required to propose air-tightness test methods, and establish air-tightness standards, based on the air leakage characteristics of domestic apartment housings. This research has been done primarily to collect basic technical data, to provide guidance for the establishment of domestic air-tightness standards for new apartment housing, through studying air-tightness test methods, field measurement on air-tightness of new apartment housings, and air leakage characteristics of major developed countries.

Glazing 특성에 따른 고층 오피스 건물의 에너지성능 분석 (The Analysis on Energy Performance according to Characteristics of Glazing in High-rise Office Buildings)

  • 황우진;김교준;최원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.156-161
    • /
    • 2011
  • In case of newly constructed buildings, the construction type is almost Curtain-wall system or large window in building skin. However, these kind of buildings have problems with regulations on building energy efficiency. And national regulations on building energy efficiency limit only the V-factor of window(except infiltration), it is hard to predict energy consumption of Curtain-wall buildings which gain large solar energy in summer. In this study, the influence of LSG(Light to Solar Gain) on energy performance was theoretically analyzed with simulation. LSG is the value of VLT divide SHGC and represents the optical performance of the glass or glazing. The Window & Therm program developed in LBNL was used to analyze window systems and EnergyPlus was used to building energy. Cases of glazing are three types; single coated Low-e clear glazing, tripple coated Low-e clear glazing, tripple coated Low-e tinted glazing. The results of this study are follows; 1) The building energy consumption of Alt-l, 2, 3 were about 300, 253, $259kWh/m^2{\cdot}yr$ respectively. Therefore, improvement of LSG could save the energy up to 16%. 2) The saved energy could be converted 1 billion won as annual benefit of total energy costs 3) SHGC and LSG more influence on cooling energy than heating energy in office buildings.

  • PDF

기존 건축물의 운영단계 에너지효율 개선을 위한 관리 및 제도화 방안 연구 (A Study on the Institutionalization of Energy Efficient Operation and Maintenance Program for Existing Buildings)

  • 조진균;이영재
    • 한국태양에너지학회 논문집
    • /
    • 제40권3호
    • /
    • pp.33-42
    • /
    • 2020
  • Operational energy is the energy that is used during the occupancy stage of building life cycle. It is associated with relatively longer proportion of infrastructure's service life and can constitute 80-90% of the total energy. Assessing the energy use in buildings is essential since they are significant contributors to energy demand. In this regard, energy performance of buildings has become the focus of many regulations. This paper aimed to review the regulations about the energy performance of buildings during their operational stage in Korea. For energy efficient operation program for existing buildings, governments should implement policies and support voluntary programs that rely on collecting and managing building performance data and using this data to inform public and private-sector operation and maintenance strategies. Implementing these policies and programs requires tools and processes for collecting, curating, managing, analyzing, and publishing this data. Energy assessment tool, that is a data resource management tool that enables to assess energy use across the entire portfolio of buildings, is also required.

미국의 실내건축 피난 규정에 관한 연구 - 실내건축계획에 있어 피난 요소를 중심으로 - (A study on the Means of Egress Codes for Interior Architecture in the United States - Focused on Evacuation Elements in the Interior Architectural Design -)

  • 김용성;조성오
    • 한국실내디자인학회논문집
    • /
    • 제27권3호
    • /
    • pp.24-32
    • /
    • 2018
  • The law reflects the situation of the times, understands the society, and shows the will of the state and the community. The Means of Egress should be maintained from design to construction, supervision, as well as use, in order to protect the lives and property of the residents as well as the safe use of the facilities. However, Interior Architects are think that evacuation and safety regulations are complex elements that change frequently and may inhibit the idea of design. The purpose of this study is to propose a design method for the use of safe facilities in the interior architectural design on the evacuation regulations affecting the actual design by the IBC(the International Building Code) and NFPA(National Fire Protection Association) LSC (Life Safety Code). The research method is to investigate and analyze the provisions related to the evacuation of interior architecture in the US and to understand the current regulations and the evacuation regulations. We suggest to design method to the details of the hallway, corridors, aisle accessway, door way, exit path, In particular, the design of furniture, tables and chairs layout that could be obstacles to evacuation situations is presented.

야영장 화재 안전대책에 관한 연구 (A Study on the Safety Measures of Camping Ground Fire)

  • 최지훈;최돈묵
    • 대한안전경영과학회지
    • /
    • 제18권1호
    • /
    • pp.57-64
    • /
    • 2016
  • The leisure life pattern of people is changing to a familial and enthusiastic way that eventually develops the camping culture. Thus, the number of campers and the size of camping market have been dramatically increased due to significant expansion of camping people. However, many camp grounds and facilities are operating without a proper registration by government rules and regulations. In addition, many of electronic and gas equipment and tools are not used in a safe way and in a safety regulatory boundary. Therefore, campers at the camping ground is situated in a fire and safety hazard. In addition, there is limitation in rules and regulations associated with camping ground safety and fire. This study analyzed the fire and hazard guidelines and rules regulations of developed countries of campground and compared them to the current situation in South Korea. Therefore, this study is to develop a safety and fire hazard guidelines and rules and regulations related to camp ground operation, gas and electronic equipment operation and management. The study will eventually reduce the future fire and safety incidents in a campground in South Korea.

Regulating Natural Lighting and Ventilation of Residential Buildings in Hong Kong Policy Implications for High-rise, High-density Housing Environments in South Korea

  • Seo, Bokyong;Kim, Sung-Hwa;Lee, Jae-Hoon
    • Architectural research
    • /
    • 제16권3호
    • /
    • pp.81-92
    • /
    • 2014
  • This study discusses the features of the lighting and ventilation regulations for residential buildings in Hong Kong. Given the compact built environment and public concerns about the environmental quality of housing, various lighting and ventilation regulations have been enacted in Hong Kong. The application of building regulations on the micro scale and incentive systems on the macro scale are present, and the governments' calls for more active participation of the private sector and use of the building environmental assessment tools were also noted. Unlike South Korea, however, Hong Kong was found to adopt more performance-based standards, consider the external factors of the lighting and ventilation conditions together with the indoor elements, and provide specific design guidelines. Notwithstanding the different climatic conditions and socio-political contexts of Hong Kong and South Korea, these findings provide some policy implications for the South Korean government in its efforts to achieve a healthy environment for high-rise, high-density housing. It is suggested that the South Korean government adopt more on-site measurement methods to reflect the environmental conditions accurately and broaden the scope and scale of the implementation of the lighting and ventilation regulations with more specific, practical planning and design guidelines.

유니버설 디자인 관점에서의 오피스환경 평가 연구 (A Evaluation of Office Environment in Universal Design)

  • 구아현;하미경
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 1999년도 춘계학술발표대회 논문집
    • /
    • pp.49-52
    • /
    • 1999
  • The purpose of this research is providing the fundamental data for the effective workplace design, so that employees are not suffered from physical barrier. This research based on literature review. And then gain actual data by auditing buildings and data have been analyzed by percentage. The results and conclusions of research are the follow: In order to evaluate the law-abiding levels of office buildings, classifying the sources as the three levels. Just 44.2 percentage of building were marked on 'compliance' level. And also the 24% was 'not compliance' 31.8% was 'not accommodation'. The actual office building was out of the allowance of regulations so the regulations should be added both about new building and ready-built buildings.

  • PDF

유니버설 디자인 관점에서의 업무시설환경평가연구-관련법규를 중심으로- (A Evaluation of Office Environment in Universal Design-by related laws-)

  • 하미경;구아현
    • 한국실내디자인학회논문집
    • /
    • 제22호
    • /
    • pp.117-122
    • /
    • 2000
  • The purpose of this research is to provide the fundamental information for the effective workplace design, so that employees are not suffered from physical barriers. This research based on literature review; and then gain actual data by auditing buildings and data have been analyzed by percentage. The results and conclusions of research are the follow : In order to evaluate the law-abiding levels of office buildings, classifying the sources as the three levels. Just 44.2 percentage of building were marked on 'compliance' level. And also the 24% was 'not compliance' 31.8% was 'not accommodation'. The actual office building was out of the allowance of regulations, so the regulations should be added both about new building and ready built buildings.

  • PDF

1950-1970년대 도시미화를 위한 서울 간선도로변 고층화제도의 사적 고찰 (Historical Review on High-rise Buildings-promoting Policies on the Main Roads of Seoul for Urban Beautification from the 1950s to the 1970s)

  • 박일향;전봉희
    • 대한건축학회논문집:계획계
    • /
    • 제35권10호
    • /
    • pp.41-52
    • /
    • 2019
  • The purpose of this study was to analyze the historical development of high-rise buildings-promoting policies in Seoul in terms of modern urban redevelopment. The results of this study were as follows; The maximum height of the buildings has been limited by National codes since 1934. But at the same time, Seoul Metropolitan government had limited the minimum building floors of roadside buildings through local regulations after the Korean War. The high-rise city had been regarded as a means of beautifying Seoul for a long time. However since the 2000s, the minimum height limit for buildings was removed from local regulations and the concept of high-rise restrictions was no longer significant as before.