• 제목/요약/키워드: Building energy efficiency

검색결과 744건 처리시간 0.024초

건물 적용 유형별 BIPVT 집열기 열적 실험성능 비교 (The Thermal Performance Comparison of BIPVT Collector Applied on Roofs and Facades)

  • 강준구;김진희;김준태
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2009년도 추계학술대회
    • /
    • pp.269-272
    • /
    • 2009
  • The temperature of PV modules that integrated into building facades or roof increases that could reduce the electrical efficiency of the PV system. In order to incresae PV system's efficiency it is very important to remove the heat from the PV modules. For this purpose, hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The solar collector utilizing this thermal effect is called photovoltaic-thermal(PVT) solar collector. This paper compares the experimental performance of building-integrated PVT collectors that applied on building roof and facade. There are two different case: a roof-integrated PVT type and a facade-integrated PVT type. The experimental results show that the collected thermal energy of the roof-integrated type was 24% higher, compared to that of the facade-integrated.

  • PDF

Cost-Effective Model for Energy Saving in Super-Tall Building

  • Song, Kwonsik;Park, Moonseo;Lee, Hyun-Soo;Kim, Sooyoung;Shin, Jinho
    • Journal of Construction Engineering and Project Management
    • /
    • 제3권3호
    • /
    • pp.17-22
    • /
    • 2013
  • In many urban cities, super-tall buildings have been being constructed around New York and Chicago as the center since 1930 to improve the efficiency of land use and respond to new residential type. In terms of energy consumption, super-tall buildings are classified as a top energy consumption building. Also, as time passed, the degradation of energy performance occurs in super-tall buildings like general things so that these cannot show the initial performance planned in the design phase. Accordingly, building owners need to make a plan to apply energy saving measures to existing building during the operation phase. In order to select energy saving measures, calculus-based methods and enumerative schemes have been typically used. However, these methods are time-consuming and previous studies which used these methods have problems with not considering the initial construction cost. Consequently, this study proposes a model for selecting an optimal combination of energy saving measures which derives maximum energy saving within allowable cost using genetic algorithms. As a contribution of this research, it would be expected that a model is utilized as one of the decision-making tools during the planning stage for energy saving.

COST-EFFECTIVE MODEL FOR ENERGY SAVING IN SUPER-TALL BUILDING

  • Kwonsik Song;Moonseo Park;Hyun-Soo Lee;Sooyoung Kim;Jinho Shin
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.294-299
    • /
    • 2013
  • In many urban cities, super-tall buildings have been being constructed around New York and Chicago as the center since 1930 to improve the efficiency of land use and respond to new residential type. In terms of energy consumption, super-tall buildings are classified as a top energy consumption building. Also, as time passed, the degradation of energy performance occurs in super-tall buildings like general things so that these cannot show the initial performance planned in the design phase. Accordingly, building owners need to make a plan to apply energy saving measures to existing building during the operation phase. In order to select energy saving measures, calculus-based methods and enumerative schemes have been typically used. However, these methods are time-consuming and previous studies which used these methods have problems with not considering the initial construction cost. Consequently, this study proposes a model for selecting an optimal combination of energy saving measures which derives maximum energy saving within allowable cost using genetic algorithms. As a contribution of this research, it would be expected that a model is utilized as one of the decision-making tools during the planning stage for energy saving.

  • PDF

미국 공동주택의 건물 외피 에너지코드 검증을 위한 BIM 에너지 계획 방안 -뉴욕시 에너지 코드를 기준으로- (BIM Energy Efficiency Plan for Verification of Building Envelop Energy Code of Housing in USA - Based on the NYC Energy Conservation Code -)

  • 허진우
    • 문화기술의 융합
    • /
    • 제8권4호
    • /
    • pp.313-322
    • /
    • 2022
  • BIM의 생산성과 효율성 때문에 건축설계 방식으로 BIM을 선택하는 건축가들이 증가하고 있다. 또한 건물의 에너지 사용량에 대한 인식 제고와 환경에 대한 관심이 높아지면서 빌딩에너지 코드의 필요성에 대한 요구가 증가하고 있다. 현재 많이 사용하고 있는 2D CAD 설계방식으로는 건물 외피 에너지코드를 검정하는데 많은 시간과 노력이 소요되며 디자인 변경에 다른 즉각적인 대응이 어렵다. 이 연구의 목적은 BIM을 통한 건물 외피 에너지 모델링의 효율성을 보여주는 데 있다. 우리는 BIM을 통해 설계과정에서 디자인 변경에 따른 정보 값을 누락이나 재계산 과정 없이 동시에 산출할 수 있기 때문에 건물 외피 에너지코드 검증에서 생산성과 효율성을 높이는 데 기여할 수 있다. 연구의 절차는 다음과 같다. Revit 2011으로 만든 the Goldin at Essex Crossing 공동주택의 BIM을 사례 모델로 하여, 뉴욕시의 에너지 코드에 부합하기 위한 에너지 계획의 기준을 분석한다. Revit 모델의 설정을 통해 나온 결과 값과 뉴욕시의 에너지코드에서 요구하는 기준 값을 비교한다. 최종적으로 미국 에너지국 (U.S. Department of Energy)에서 제공하는 에너지 검증 프로그램인 COMcheck에 데이터값을 입력하여 건물 외피 에너지 성능이 뉴욕시 에너지 코드에 부합하는 지 여부를 체크한다.

수직 공간 내에서 고도변화에 따른 기압차로 인한 기류현상 예측에 관한 연구 (Effect of Atmospheric Pressure Difference with Altitude on the Induced Airflow Velocity in a Vertical Closed Conduit)

  • 정광섭;김철호
    • 설비공학논문집
    • /
    • 제21권7호
    • /
    • pp.409-416
    • /
    • 2009
  • On 21st century, global warming is the most serious environmental problem threatening the existence of lives on the earth. One of the serious reasons of this nature phenomena was due to the greenhouse effect by carbon dioxide mainly produced with the combustion process of hydro-carbon fuel. and it is mostly produced. In the high oil prices age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating large percentage whole building loads, and are regarding as the primary target of energy efficiency. The purpose of this research is on the obtaining of the renewable energy source in the skyscrape buildings in the metropolitan area. The air movement is happens due to the atmospheric pressure differences in the air. Due to this simple physical theory, it is easily expected to obtain the useful renewable nature energy through the high -raised vertical air stack installed in a tall building. However, there is one problem that should be resolved which is called air-hole effect in the sky -scrape buildings.

Monitoring of wind effects on an instrumented low-rise building during severe tropical storm

  • Li, Q.S.;Hu, S.Y.
    • Wind and Structures
    • /
    • 제20권3호
    • /
    • pp.469-488
    • /
    • 2015
  • A full-scale instrumented low-rise building with gable roof was built at a coastal site with a high incidence of tropical cyclones for monitoring of wind effects on the building during windstorms. This paper presents the field measurements of the wind velocity field around and the wind-induced pressures on the low-rise building during the passage of severe tropical storm Soudelor. Near-ground wind characteristics such as wind speed, wind direction, turbulence intensity, gust factor, turbulence integral length scale and wind velocity spectra were investigated. The wind-induced pressures on the roof of the building were analyzed and discussed. The results revealed that the eave and ridge edges on the roof were subjected to the most severe suction pressures under quartering winds. These suction pressures showed obvious non-Gaussian behavior. The measured results were compared with the provisions of ASCE 7-10 to assess the suitability of the code of practice for the wind-resistant design of low-rise buildings under tropical cyclones. The field study aims to provide useful information that can enhance our understanding of the extreme wind effects on low-rise buildings in an effort to reduce tropical cyclone wind damages to residential buildings.

최근 아파트의 에너지 사용량 특성과 요인 분석 (An Analysis on Characteritics and Causes of Energy Usage of Contemporary Apartment Houses)

  • 최석두;이영한
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.143-149
    • /
    • 2016
  • Purpose: This study is to analyze the characteristics of energy usage in apartment houses that had built for 20 years recently in capital area and the correlation between the characteristics of energy usage and the regulation of energy efficiency in building. Method: It is investigated 264 apartment sites having been built since 1991 where 312,071 houses live. The sites were listed on Naver map. Quantities of energy usages in the sites were searched in a portal, Green Together being operated by the Ministry of Land, Infrastructure and Transport. The appraisal report of building energy in the portal is recording usage quantity of gas energy, district cooling & heating energy, electric energy, total energy, 1st gas energy, 1st district cooling & heating energy, 1st electric energy, 1st total energy, etc. Result: Analyzing the average of total energy usage from 1991 to 2012, the average in 2001, 2008 each was reduced more than 10 percent compared to the previous year. It was analyzed that the reduction was relevant to building energy-saving design criterion which have been tightened more than before.

Energy Sustainability of an Integrative Kinetic Light Shelf Unit

  • Han, Seung-Hoon
    • KIEAE Journal
    • /
    • 제15권3호
    • /
    • pp.15-20
    • /
    • 2015
  • Purpose: Suggesting a working prototype of a kinetic light shelf unit and revealing its energy efficiency by a series of building performance simulations were presented. Recently, kinetic building envelope has been an emerging technology as an innovative way to control exterior building environment, but products from many researches about the facade could not been reached to the industrialization so far. That is because its initial installation, operation and maintenance costs are still too high to use for the practical field, although buildings using kinetic envelopes could decrease their energy consumption significantly. This narrow point of view needs to be reconsidered, since buildings require great amount of energies to run their functions through the whole life and using better building components can lead to achieve much more benefits in aspects of the lifecycle cost (LCC). Method: A series of certified simulation tools like Ecotect and Green Building Studio that are normally used for researches and developments in the field of architecture were utilized. Result: Based on simulation analyses, the result of the study has showed that the proposed system definitely has adaptability to the professions and positively shows practicability as advanced integrative building envelopes with renewable energy association.

창호 블라인드와 상변화물질 적용에 의한 냉방 에너지 사용량 절감효과에 대한 검토 연구 (Experimental Study of Cooling Energy Saving Verification Using Blinds and Phase Change Material(PCM))

  • 송영학;김기태;구보경;이건호
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.26-31
    • /
    • 2014
  • This study looks into changing building energy use by application of phase change material (PCM). PCM does not need extra energy for operation and is used for reducing building energy use and, CO2 output by displaying semi-permanent effects after installation. It also is able to avoid the maximum electric power time-zone by inducing a time lag phenomenon of cooling and heating loads with high thermal capacity using latent heat. To verify the efficiency of blinds and PCM, tests about the PCM operation mechanism using air conditioning machinery and nocturnal panel cooling were done. In the test results of the case using PCM installation, a $45^{\circ}$ blind angle with machinery air conditioning and nocturnal panel cooling at the same time shows a 22 percent energy saving effect against general space. The test results of each case were compared and analyzed based on the blind and window opening settings. Finally, the energy reduction of existing buildings using PCM application was reviewed based on the final measurement results.

친환경 병영시설 모델개발을 위한 설계요소 분석 (A Study on Design Technologies for Sustainable Army Barracks)

  • 박찬혁;조우석;강윤도;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.256-262
    • /
    • 2009
  • Purpose of this study is embody the environmental-friendly military facility model that applied renewable energy, passive design method and high efficiency equipment. In the introduction of this study, defined problem of existing military facility and classification of military facility are performed. Also, environmental friendly military facility is defined through classified by scale and building equipment method. In the renewable energy chapter, photovoltaic system and wind turbine system are considered And then, LED light, photovoltaic panel, motor, inverter are analyzed in the high efficiency equipment chapter.

  • PDF